Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Similar documents
Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Thermowell For sanitary applications Model TW61, for orbital welding

Thermowell For sanitary applications Model TW61, for orbital welding

Thermowell For sanitary applications Model TW61, for orbital welding

Thermowell For sanitary applications Model TW61, for orbital welding

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

NEUMO BioControl Model

Resistance thermometer with digital display Model TR75, battery operation

High-quality pressure sensor with mounted diaphragm seal With clamp connection Model DSS22T

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

Resistance thermometer with digital indicator Model TR75, battery operation

Measuring insert for process resistance thermometer

Pressure Transmitters for Sanitary Applications Model SA-11

High-quality pressure sensor with mounted diaphragm seal With flange connection, flush diaphragm Model DSS27T

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Pressure gauge per EN with mounted diaphragm seal With clamp connection Model DSS22F

Thermowell For sanitary applications Model TW22

Pressure gauge per EN with mounted diaphragm seal With SMS threaded connection Model DSS19F

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications

Resistance thermometer Model TR10-E, for additional thermowell

High-quality pressure sensor with mounted diaphragm seal With threaded connection, welded design Model DSS34T

High-quality pressure sensor with mounted diaphragm seal With threaded connection, threaded design Model DSS10T

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

Insertion thermometer With connection lead Model TF45

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Accessories for diaphragm seals Block flange and saddle flange Models , ,

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Thermocouple with spring-loaded tip Model TC55

Pressure gauge in hygienic design with mounted diaphragm seal With clamp connection Model DSS22P

Duct thermometer Model TF40

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Resistance thermometer Model TR10-B, for additional thermowell

Electronic flow switch With display, for liquid media Model FSD-3

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

Diaphragm seal with sterile connection For homogeniser machines Model

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Measuring insert for resistance thermometer Model TR10-A

Pressure gauge per EN with mounted diaphragm seal With threaded connection, threaded design Model DSS10M

Float switch For horizontal installation, miniature design Model HLS-M

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Diaphragm monitoring system with clamp connection For sanitary applications Model DMS-FP

Thermocouple Model TC10-H without thermowell

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Pressure switch, high adjustability of switch differential

Float switch For industrial applications, with temperature output Model RLS-3000

Thermocouple For additional thermowell Model TC10-B

Portable pressure calibrator, Wally Box III Model CPH7600

Surface thermocouple Model TC50

Bimetal thermometer Model 52, industrial series

Resistance thermometer Without thermowell Model TR10-H

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40

Diaphragm pressure gauge, flush For sanitary applications, NS 100 Model PG43SA-D, with integrated diaphragm element monitoring

Tubeskin thermocouple assembly Model TC59-W

Cable resistance thermometer Model TR40

Differential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar

Mechatronic pressure measurement. Applications. Special features. Description

Reed sensor For bypass level indicators Model BLR

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Thermocouple Without thermowell Model TC10-H

Temperature multi-function calibrator Model CTM

Tubeskin thermocouple assembly Model TC59-V

Screw-in thermometer with connection lead Model TF37

Miniature multipoint thermocouple Model TC96-M

Type A-10 General Purpose Pressure Transmitter

Bimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version

Thermocouples Model TC10-B, for Additional Thermowell

Differential pressure gauge with electrical output signal Model A2G-15

Bimetal thermometer Model 52, industrial series

Bourdon tube pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21PB, NS 60, 80 and 100

Type A-10 General Purpose Pressure Transmitters

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Duplex pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21DPB, NS 60, 80, 100 and 130

Tubeskin thermocouple assembly Model TC59-V

Connecting parts with nominal width DN 20 Valves, coupling valves, protection caps, fittings, adapters and connections for analytic instruments

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Thermocouple Model TC10-E, for additional thermowell

Mini temperature switch Stainless steel switch enclosure Model TXS

Diaphragm seal with flange connection For the pulp and paper industry Model

Cable thermocouple Model TC40

Compact temperature switch Model TCS

Differential pressure gauge Model , copper alloy Model , stainless steel version

Differential pressure gauge with switch contacts For the process industry, all-metal media chamber Models DPGS43.100, DPGS43.160

Transcription:

Electrical temperature measurement Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design WIKA data sheet TE 60.57 Applications Sanitary applications Food and beverage industry Bio and pharmaceutical industry, production of active ingredients Special features No intrusion into the pipeline Compact design for space-saving mounting Simple and fast electrical connection using an M12 x 1 plug connection Measuring insert removable and calibratable Pipe surface resistance thermometer, model TR57-M Description Pipe surface resistance thermometers of the TR57-M series are used for non-invasive temperature measurement on pipelines. These resistance thermometers can be retrofitted at any time to an existing pipe, without opening or interrupting the process. The resistance thermometers can be used in a temperature range from -20... +150 C. The fixing of the measuring insert onto the pipeline is achieved using a pipe adapter. The measuring insert is spring-loaded and the sensor tip is isolated against the ambient temperature through the silicon lining of the pipe adapter. All electrical components are protected against moisture (IP67). The resistance thermometer is available with direct sensor output or integrated transmitter. Through the compact design, this resistance thermometer is designed specifically for operation in applications with limited mounting space. Process connection, sensor and connection method can each be selected for the respective application from the ordering information. The electrical connection is made via an M12 x 1 circular connector. The measuring insert can be removed for calibration. WIKA data sheet TE 60.57 08/2017 Page 1 of 6 Data sheets showing similar products: Miniature resistance thermometer, with flange connection; model TR21-A; see data sheet TE 60.26 Miniature resistance thermometer, for orbital welding; model TR21-B; see data sheet TE 60.27 Miniature resistance thermometer, with integrated sterile connection; model TR21-C; see data sheet TE 60.28

Specifications Thermometer with transmitter and 4... 20 ma output signal Process temperature range Standard: -20... +100 C (-4... +212 F), max. 150 C (302 F) for 30 min 1) Extended: -20... +150 C (-4... +302 F) 1), only with transmitter measuring range 0... 150 C Connection method 3-wire Measurement accuracy of the overall 2.5 % of full scale value 2) instrument Measurement accuracy of the overall 1.0 % of full scale value 2) instrument with thermal compound Measuring range of the transmitter -10... +50 C 0... 100 C 0... 150 C The measuring range is fixed. Analogue output 4... 20 ma, 2-wire Power supply U B DC 10... 30 V Response time approx. t 90 = 10 s 2) Switch-on delay, electrical Max. 1 s (time before the first measured value) Current value for error signalling Upscale approx. 22 ma Load R A R A (U B - 10 V) / 23 ma with R A in Ω and U B in V Electrical connection Power supply input Protected against reverse polarity Electromagnetic compatibility (EMC) EN 61326 emission (group 1, class B) and interference immunity (industrial application) 3) Thermometer with direct sensor output with Pt100 Process temperature range Measuring element Temperature at the connector Connection method 3-wire 3) -20... +150 C (-4... +302 F) Pt100 (measuring current max. 10 ma, 0.3... 1 ma recommended) Max. 85 C (185 F) Tolerance value of the measuring element Class A 2) in accordance with IEC 60751 Measurement accuracy of the overall 2.5 % of full scale value 2) instrument Measurement accuracy of the overall 1.0 % of full scale value 2) instrument with thermal compound Response time approx. t 90 = 10 s 2) Electrical connection Ambient conditions Ambient/storage temperature range Maximum permissible humidity per IEC 60068-2-30 var. 2 Ingress protection IP67 per IEC/EN 60529 Without transmitter: -20... +85 C (-4... +185 F) With transmitter: -20... +60 C (-4... +140 F) 70 % r. h. 4) For detailed specifications for Pt sensors, see Technical information IN 00.17 at www.wika.com. Readings in % refer to the measuring span 1) The temperature transmitter should therefore be protected from temperatures over 60 C (140 F). 2) Measuring results are dependent upon the individual mounting situation Recommendation for achieving a high measurement accuracy: The bigger the pipe cross-section, the bigger the contact surface is between sensor and pipe surface. The thinner the pipe wall, the better the thermal connection is between sensor and process medium. The higher the flow rate, the better the heat transfer is between the process medium and the environment at the pipe surface. 3) Use resistance thermometers with shielded cable, and, if the lines are longer than 30 m or leave the building, ground the shield on at least one end of the lead. The instrument must be operated grounded. 4) Only with M12 circular connector fitted or during storage with M12 protection cap fitted Page 2 of 6 WIKA data sheet TE 60.57 08/2017

Measuring insert Spring Stainless steel 1.4310 Probe insert PEEK Sensor tip 935 silver M12 circular connector PA / gold-plated contacts Weight 20 g Process connection Pipe adapter Stainless steel 1.4405 Weight Size 1 Size 2 Size 3 Size 4a, 4b 120 g 170 g 395 g 955 g Case Stainless steel 1.4305 Adapter insert Silicone HTV/PTFE Dimensions in mm With transmitter Process temperature range -20... +150 C (-4... +302 F) M12x1 14212064.01 102.5 20 DN B 18 WIKA data sheet TE 60.57 08/2017 Page 3 of 6

Ohne Transmitter With transmitter Process temperature range -20... +100 C (-4... +212 F), max. 150 C (302 F) for 30 min Without transmitter Process temperature range -20... +150 C (-4... +302 F) M12x1 M12x1 14212064.01 Mit Transmitter 20 66.5 DN 18 B Overview of pipe adapters with pipe diameter Adapter Outer diameter of Nominal width of Standard Dimensions in mm designation pipe in mm pipe in mm/inch B 120 12.0 DN 10 EN 10357 series B 51 11 130 13.0 DN 10 EN 10357 series A 51 11 130 12.7 ½" DIN 11866 row C / ASME BPE 51 11 135 13.5 DN 8 DIN 11866 row B (ISO 1127) 51 11 172 17.2 DN 10 DIN 11866 row B (ISO 1127) 51 11 180 18.0 DN 15 EN 10357 series B 51 11 190 19.0 DN 15 EN 10357 series A 51 11 190 19.0 ¾" DIN 11866 row C / ASME BPE 51 11 213 21.3 DN 15 DIN 11866 row B 64 11 230 23.0 DN 20 EN 10357 series A 64 11 254 25.4 1" DIN 11866 row C / ASME BPE 64 11 269 26.9 DN 20 DIN 11866 row B 64 11 280 28.0 DN 25 EN 10357 series B 64 11 290 29.0 DN 25 EN 10357 series A 64 11 337 33.7 DN 25 DIN 11866 row B 64 11 337 34.0 DN 32 EN 10357 series B 64 11 350 35.0 DN 32 EN 10357 series A 64 11 381 38.1 1 ½" DIN 11866 row C / ASME BPE 92 14 400 40.0 DN 40 EN 10357 series B 92 14 410 41.0 DN 40 EN 10357 series A 92 14 424 42.4 DN 32 DIN 11866 row B 92 14 483 48.3 DN 40 DIN 11866 row B 92 14 508 50.8 2" DIN 11866 row C / ASME BPE 92 14 520 52.0 DN 50 EN 10357 series B 92 14 530 53.0 DN 50 EN 10357 series A 92 14 603 60.3 DN 50 DIN 11866 row B 133 14 635 63.5 2 ½" DIN 11866 row C / ASME BPE 133 14 700 70.0 DN 65 EN 10357 series A 133 14 761 76.1 DN 65 DIN 11866 row B 133 14 761 76.2 3" DIN 11866 row C / ASME BPE 133 14 850 85.0 DN 80 EN 10357 series A 133 14 889 88.9 DN 80 DIN 11866 row B 133 14 Page 4 of 6 WIKA data sheet TE 60.57 08/2017

Accessories Model Special features Order number M12 connection cable Cable socket straight, 4-pin, ingress protection IP67 Temperature range -20... +80 C Cable socket straight, 4-pin, ingress protection IP69K, Hygienic Design Temperature range -40... +80 C Angled socket, 4-pin, ingress protection IP67 Temperature range -20... +80 C Angled socket, 4-pin, ingress protection IP69K, Hygienic Design Temperature range -40... +80 C Cable length 2 m 14086880 Cable length 5 m 14086883 Cable length 3 m 14137167 Cable length 5 m 14137168 Cable length 2 m 14086889 Cable length 5 m 14086891 Cable length 3 m 14137169 Cable length 5 m 14137170 Electrical connection Output signal 4... 20 ma Output signal Pt100 sensor Pin Signal Description 1 L+ 10... 30 V 2 L- 0 V 3 L- 0 V 4 C do not use Load diagram The permissible load depends on the loop supply voltage. 870 609 Load RA in Ω 0 10 24 30 Voltage U B in V WIKA data sheet TE 60.57 08/2017 Page 5 of 6

Approvals Logo Description Country EU declaration of conformity EMC directive 1) EN 61326 emission (group 1, class B) and interference immunity (industrial application) RoHS directive European Union 1) Only for built-in transmitter Approvals and certificates, see website Ordering information Model / Output signal (Pt100 or 4... 20 ma) / Measuring range / Outer diameter of pipe / Certificates / Options 08/2017 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 6 of 6 WIKA data sheet TE 60.57 08/2017 08/2017 EN WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de