functions: --Staircase timer --Staircase timer + maintenance function --Staircase timer with early warning

Similar documents
Multi-function. Mono-function 1 NO (SPST-NO)

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

MasterINTERFACE 39 Series - Relay interface modules

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

55 Series - Miniature General Purpose Relays 5-10 A

2 pole 10 A PCB mount A1 A

40 Series - Miniature PCB relays A. Features

5 mm contact pin pitch PCB or 95 series sockets

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

General purpose relays 6-10 A

Slim P.C.B. Relays (EMR or SSR) A

Installation Contactors RIC, RAC

60 Series - General purpose relays 6-10 A. Features SERIES

General purpose relays 7-10 A

Miniature Industrial relay 8-16 A

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

Command and signalling E 250, E 259 selection table

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current

Defining a timer in simple terms. Which actions are executed? Which market are they used frequently? Benefits and Advantages

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

RUC industrial relays of small dimensions

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Installation Relays. Power Relays Step-on Step-off Relays Staircase Lighting Timers Power Step-on Step-off Relays Installation Contactors 103 KAT

44 SERIES. PCB/Plug-in relays from 6 to 10 A

Emergency lighting units EM powerled

CI-TI Contactors and Motor Starters Type CI 6-50

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Emergency lighting units EM powerled

Modular contactor for installation into distribution boards

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

CI-TI Contactors and motor starters Types CI 61 - CI 98

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Ordering Information. Text PCB Power Relay G5LE

Scheda prodotto Relè Series E

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

Compact Sheet-Steel Light Fittings Series 6114/1

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Electronic Ballast EVG 2000-T

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Definite Purpose Contactors

Emergency lighting units EM Inverter

SERIES SINGLE AND DOUBLE-POLE PUSHBUTTON SWITCHES

Data sheet TERMSERIES TRZ 120VUC 1CO

IMPROVED LIGHTING CONTROLS

Emergency lighting units EM powerled

BF Series Flasher Thermal flasher circuitry

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

Modular Contactors and Switches D681E121

EM BASIC V 50/60 Hz

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Emergency lighting units EM powerled

Micro Contactor MA Series

Electropneumatic Timing Relays Series 7000 Industrial

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Cat N 3. OVERALL DIMENSIONS

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

Pack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Industrial Contactors CTX 3 3P 185A - 800A

Emergency lighting units EM powerled

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

Emergency lighting units EM powerled

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

Scheda prodotto Relè Series B

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

R600 & R500. Interface relays R600, R500. Phone: Fax: Web: -

BETA Switching Switching Devices

Description. Positive safety relays

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Emergency lighting units EM INVERTER

Emergency lighting units EM INVERTER

Modular contactors and relays

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Timer Relays - Fixed & Adjustable

Industrial contactors CTX-1

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

DEEP SEA ELECTRONICS PLC

Transcription:

14 SERES 14 SERES Multi-function electronic staircase timers 1 O 16 A 17.5 mm wide Type 14.01 --8 functions --Switch-off early warning options Type 14.71 --3 functions Time setting from 30 seconds to 20 minutes Zero crossing load switching Switch-off early warning - model 14.01 Suitable for 3 or 4 wire systems, with automatic recognition Compatible with movement detectors (18 series) ED status indicators Cadmium free contact material Can be used with illuminated push - buttons Blade + cross - both flat blade and cross head screw drivers can be used to adjust the function selector, the timing trimmer, and to disengage the 35 mm rail mounting clip 35 mm rail (E 60715) mount European Patent 14.01/71 14.01 14.71 8 functions: --Staircase timer --Staircase timer + maintenance function --Staircase timer with early warning --Staircase timer with early warning + maintenance function --Timing step relay --Timing step relay with early warning --Step relay --ight O 3 functions: --Staircase timer --Staircase timer + maintenance function --ight O For outline drawing see page 8 Contact specification Contact configuration 1 O (SPST-O) 1 O (SPST-O) Rated current/maximum peak current A 16/30 (120 A - 5 ms) 16/30 (120 A - 5 ms) Rated voltage/ Maximum switching voltage V AC 230/ 230/ Rated load AC1 VA 3700 3700 Rated load AC15 (230 V AC) VA 750 750 ominal lamp rating: 230 V incandescent/halogen W 3000 3000 fluorescent tubes with electronic ballast W 1500 1500 fluorescent tubes with electromagnetic ballast W 1000 1000 CF W 600 600 230 V ED W 600 600 V halogen or ED with electronic ballast W 600 600 V halogen or ED with electromagnetic ballast W 1500 1500 Minimum switching load mw (V/mA) 1000 (10/10) 1000 (10/10) Standard contact material AgSnO 2 AgSnO 2 Supply specification ominal voltage (U ) V AC (50/60 Hz) 230 230 V DC Rated power VA (50 Hz)/W 3/1.2 3/1.2 Operating range AC (50 Hz) (0.8 1.1)U (0.8 1.1)U DC Technical data Electrical life at rated load in AC1 cycles 100 10 3 100 10 3 Delay setting min 0.5 20 0.5 20 Max no. of illuminated push-button ( 1 ma) 30 30 Maximum impulse duration continuous continuous Ambient temperature range C 10 +60 10 +60 Protection category P 20 P 20 Approvals (according to type) 1

14 SERES 14 SERES Mono-function electronic staircase timers 1 O 16 A 17.5 mm wide Type 14.81 --Staircase timer + maintenance function Type 14.91 --Signal O pulse timer Time setting from 30 seconds to 20 minutes Zero crossing load switching Wiring compatible with mechanical versions and with old type (low emission) illuminated pushbuttons Suitable for 3 or 4 wire systems, via pushbutton configuration 110 125 V AC supply version available (14.81) Cadmium free contact material Can be used with illuminated push - buttons Blade + cross - both flat blade and cross head screw drivers can be used to adjust the function selector, the timing trimmer, and to disengage the 35 mm rail mounting clip 35 mm rail (E 60715) mount 14.81 14.91 Mono-function: --Staircase timer + maintenance function All 4 terminal on same side Mono-function: --Signal O pulse timer All 3 terminal on same side 14.81/91 For outline drawing see page 8 Contact specification Contact configuration 1 O (SPST-O) 1 O (SPST-O) Rated current/maximum peak current A 16/30 (120 A - 5 ms) 16/30 (120 A - 5 ms) Rated voltage/ Maximum switching voltage V AC 230/ 230/ Rated load AC1 VA 3700 3700 Rated load AC15 (230 V AC) VA 750 750 ominal lamp rating: 230 V incandescent/halogen W 3000 3000 fluorescent tubes with electronic ballast W 1500 1500 fluorescent tubes with electromagnetic ballast W 1000 1000 CF W 600 600 230 V ED W 600 600 V halogen or ED with electronic ballast W 600 600 V halogen or ED with electromagnetic ballast W 1500 1500 Minimum switching load mw (V/mA) 1000 (10/10) 1000 (10/10) Standard contact material AgSnO 2 AgSnO 2 Supply specification ominal voltage (U ) V AC (50/60 Hz) 110 125/230 230 V DC Rated power VA (50 Hz)/W 3/1.2 3/1.2 Operating range AC (50 Hz) (0.8 1.1)U (0.8 1.1)U DC Technical data Electrical life at rated load in AC1 cycles 100 10 3 100 10 3 Delay setting min 0.5 20 0.5 20 Max no. of illuminated push-button ( 1 ma) 25 25 Maximum impulse duration continuous continuous Ambient temperature range C 10 +60 10 +60 Protection category P 20 P 20 Approvals (according to type) 2

14 SERES 14 SERES Ordering information Example: 14 series multi-function timer, 1 O (SPDT-O) 16 A contact, supply rated at 230 V AC. 1 4. 0 1. 8. 2 3 0. 0 0 0 0 Series Type 0 = 35 mm rail (E 60715) mount, 8 functions 7 = 35 mm rail (E 60715) mount, 3 functions 8 = 35 mm rail (E 60715) mount mono-function, all terminals on same side 9 = 35 mm rail (E 60715) mount, mono-function, 3 terminals Supply voltage 120 = 110 125 V AC (14.81 only) 230 = 230 V Supply version 8 = AC (50/60 Hz) o. of poles 1 = 1 O 16 A contact Technical data nsulation Dielectric strength between open contacts V AC 1000 Other data Power lost to the environment without contact current W 1.2 with rated current W 2 Maximum cable length for push-button connection m 200 Screw torque m 0.8 Max. wire size solid cable stranded cable mm 2 1 x 6 / 2 x 4 1 x 4 / 2 x 2.5 AWG 1 x 10 / 2 x 12 1 x 12 / 2 x 14 Zero crossing switching 1 - ower inrush current protects and increases lamp life 2 - ower inrush current reduces the possibility of contact welding 3 - The current at switch-off is also lower, reducing stress and wear on the contacts ote Using the type 14.91, the lamps are switched on directly by the push-button Accessories Adaptor for panel mounting, 17.5 mm wide 020.01 020.01 060.72 Sheet of marker tags, plastic, 72 tags, 6 x 12 mm 060.72 3

14 SERES 14 SERES Wiring diagrams Type 14.01 14.71 Red ED indication: Continuous = relay O Blinking = relay OFF 3 wire connection 4 wire connection Type 14.81 (push-button configuration procedure, as per the nstallation manual) 3 wire connection 4 wire connection Type 14.91 (the push-buttons must be rated for the load current) 4

14 SERES 14 SERES Wiring diagrams - 14.01 or 14.71 without Staircase maintenance function, triggered by PR movement detector (18 series). 3 wire connection (with 18.21.8.230.0300 or 18.31.8.230.0300 only) 4 wire connection (with 18.21.8.230.0300 or 18.31.8.230.0300 only) 4 wire connection (with 18.01.8.230.0000 or 18.11.8.230.0000 only) 5

14 SERES 14 SERES Functions Type 14.01 Functions selectable with front rotary selector (BE) Staircase timer On initial impulse the output contact closes and timing starts for the pre-set duration; subsequent impulses during the timing period will extend the timing period by the full pre-set value. On expiry of the time delay, the output contact opens. BE + (ME) Staircase timer + Staircase maintenance n addition to the Staircase timer function (BE), an impulse of 5 seconds will close the output contact for 60 minutes, after which time the contact will open. deal for maintenance or cleaning activities. The 60 minute timing can be interrupted by a further impulse of 5 seconds, and the output contact then opens (BP) Staircase timer with early warning On initial impulse the output contact closes and the timing starts for the pre-set duration. After the timing period, the output contact blinks off once; 10secs later the contact blinks off twice, and after a further 10secs the contact opens. During the pre-set and 20 second warning time, it is possible, by a further impulse, to extend the time by the full pre-set value. BP + (MP) Staircase timer with early warning + Staircase maintenance n addition to the Staircase timer function (BP), an impulse of 5 seconds will close the output contact for 60 minutes, after which time the contact will open. deal for maintenance or cleaning activities. The 60 minute timing can be interrupted by a further impulse of 5 seconds, and the output contact then opens (T) Timing step relay On initial impulse the output contact closes and timing starts for the pre-set duration; On expiry of the time delay, the output contact opens. During the timing period it is possible to immediately open the contact with a further impulse. (P) Timing step relay with early warning On initial impulse the output contact closes and timing starts for the pre-set duration; After the timing period, the output contact blinks off once; 10 secs later the contact blinks off twice, and after a further 10 secs the contact opens. During the pre-set and 20 second warning time, it is possible to immediately open the output contact by a further impulse. (R) Step relay After every impulse, the output contact changes state - alternately switching from open to closed and vice versa. ight O With this function set - the output contact stays permanently closed. OTE: The blinking within the Early Warning functions (BP and P) could cause re-start problems for fluorescent lamps with electromagnetic chokes (both conventional and compact types); We consequently suggest not to use such lamps with these functions. 6

14 SERES 14 SERES Functions Type 14.71 Functions selectable with front selector 3-function front selector Staircase timer + Staircase maintenance ight O Staircase timer (compatible with 18 series movement detectors) Staircase timer On initial impulse the output contact closes and timing starts for the pre-set duration; subsequent impulses during the timing period will extend the timing period by the full pre-set value. On expiry of the time delay, the output contact opens. Staircase maintenance An impulse of 5 seconds will close the output contact for 60 minutes, after which time the contact will open. deal for maintenance or cleaning activities. The 60 timing can be interrupted by a further impulse of 5 seconds, the output contact opens. ight O With this function set - the output contact stays permanently closed. Type 14.81 Staircase timer On initial impulse the output contact closes and timing starts for the pre-set duration; subsequent impulses during the timing period will extend the timing period by the full pre-set value. On expiry of the time delay, the output contact opens. Staircase maintenance function An impulse of 5 seconds will close the output contact for 60 minutes, after which time the contact will open. deal for maintenance or cleaning activities. The 60 timing can be interrupted by a further impulse of 5 seconds, which will re-establish the staircase timer function; so on expiry of the staircase time delay, the output contact opens. Type 14.91 Signal O pulse On initial impulse the output contact closes, and remain so for the duration of the preset delay. On expiry of the time delay, the output contact opens. 7

14 SERES 14 SERES Outline drawings 14.01 14.71 14.81 14.91 8