AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve

Similar documents
AKM 105, 115: Rotary actuator for ball valve

AVM 215S-R: Valve actuator with SAUTER Universal Technology (SUT)

AVM 105, 115: Valve actuator

Pushing 1) force. Motor Spring [N] [kg]

ADM 322: Rotary actuator

A44 W0...W2: Motorised actuator

AVP : Pneumatic valve actuators

AVM321, 322: Actuator SAUTER vialoq AVM 1000

AXS 215S: Continuous actuator for unit valves, with stroke indicator

AVP : Pneumatic valve actuators

BQE: 3-way flanged valve, PN 16

BUE: 3-way flanged valve, PN 16/10 (el.)

BUN: 3-way valve with male thread, PN 16

BUN: 3-way valve with male thread, PN 16

FlowControl BUE/BQE 2 & 3 - way control valves

EGQ 212: Duct transducer, CO 2 and temperature

AXT201, 211: Thermal actuator for unit valves, with stroke indicator

Valves and actuators. SAUTER control units for all of your requirements.

VUD: 2-way flanged valve, PN 6 (pn.)

BUD: 3-way flanged valve, PN 6 (pn.)

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

FlowControl VUN/BUN 2 & 3 - way control valves

VDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

AEL5 Series Electric Linear Actuators for DN15 to DN100 Control Valves

Connection. k VS -Value m 3 /h

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

SAX Electronic Valve Actuator

Control solutions Biofloor

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

EL5600 Series Electric Actuators for DN15 to DN100 Valves

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Type 231 ACTUATOR FOR DAMPERS. G R U N E R t h e. f r i e n d l y a l t e r n a t i v e. Actuator with rotation drive. 20 Nm 30 Nm

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Ball valve and actuator. Maximum control precision for a wide variety of applications.

SAV Electronic Valve Actuator

Rotary actuators for ball valves

VCL : 2-way regulating valve for dynamic hydronic balancing, PN 16, Valveco

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption In operation At rest For wire sizing

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

Connection. k VS -Value m 3 /h

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

HERZ Motorised Actuator

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

Product features & Overview. KA Linear actuators

Power consumption In operation At rest For wire sizing

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

VA-7150 Electric Valve Actuator. Features and Benefits. G 500N force output in a compact unit G Magnetic clutch. G Unique Yoke Design

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

See «Overview of types»

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

Overview of types. Technical data

NV Direct Coupled Globe Valve Actuator

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

USER S MANUAL. Installation, Operation, & Maintenance

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

Electromotoric Actuators

ML7420A/ML7425A,B. Honeywell. Electric Linear Valve Actuator FEATURES SPECIFICATIONS GENERAL SPECIFICATION DATA

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

GDB..3..1A GLB..3..1A

Electromotoric actuators

Power consumption In operation At rest For wire sizing

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

Electromotoric Actuators

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Attachments. Open/Close actuators. For the opening and closing of dampers in air conditioning. 06/2017 DE/en PD OC 1

Electro-hydraulic actuators for valves

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Electronic pressure switch with integrated analogue output

Power consumption In operation At rest For wire sizing

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Linear actuator. Product features. Overview. Wide range of force outputs. Wide selection of column adapters. Wide selection of flanges

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Electromotoric Actuators

Actuators for modulating control AME 110 NL, AME 120 NL

Actuators for small valves

Transcription:

Product data sheet 5.1 51.364 AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve How energy efficiency is improved Automatic adaptation to ball valve, precise activation and high energy efficiency with minimal operating noise. Features For operating 2- and 3-way ball valves VKR, VKRA, BKR, BKRA, VKAI, VKAA, BKLI, BKTI, BKTA, (AKM115S) and 6-way ball valve B2KL For controllers with constant output (0...10 V) or switching output (2-/3-point control) Assembly with ball valve without the use of tools Stepping motor with SAUTER Universal Technology (SUT) electronic control unit Electronic force-dependent motor cut-off Automatic recognition of applied control signal (continuous or switched) Coding switch for selection of characteristic and running time (35 s, 60 s, 120 s) Type of characteristic (linear/quadratic/equal-percentage) can be set on the actuator Direction of operation can be selected directly on the cable Maintenance-free gear unit Gear unit can be disengaged in order to position the ball valve manually (using the lever) Bracket and bayonet ring made of glass-fibre-reinforced plastic for fitting onto ball valve AKM115SF132 Technical data Power supply Power supply 24 V~ ±20%, 50...60 Hz Power supply 24 V= -10%...20% Power consumption 4.9 W/8.7 VA Running time1) 35/60/120 s Angle of rotation 90 Response time 200 ms Parameters Positioner Power cable 1.2 m, 5 0.5 mm2 Positioning signal y 0...10 V, Ri > 100 kω Positional feedback signal 0...10 V; load > 10 kω Starting point U0 0 V or 10 V Control span ΔU 10 V Switching range Xsh 200 mv Temperature of medium2) Max. 100 C Admissible ambient temperature 10...55 C Admissible ambient humidity 5...95% rh, no condensation Fitting Vertically upright to horizontal, not upside down Ambient conditions Construction Weight 0.7 kg Housing Lower section black, upper section yellow Housing material Fire-retardant plastic Type of protection IP54 as per EN 60529 Standards and directives CE conformity according to 1) 2) Protection class III as per IEC 60730 EMC Directive 2014/30/EU EN 61000-6-1, EN 61000-6-3 EN 61000-6-4 Directive 2006/95/EC Machine directive (EN 1050) For a running time of 35 s, the torque is halved At media temperatures < 5 C or > 100 C, appropriate accessory must be used Right of amendment reserved 2017 Fr. Sauter AG 1/7

Overview of types Type AKM105SF132 AKM115SF132 Accessories Type Torque 4 Nm 8 Nm Description 0313529001 Split-range unit for adjusting sequences, fitted in separate junction box 0372462001 CASE Drives PC tool for configuring the drives by computer 0510420001 Adaptor required when temperature of the medium > 100 C 0510240011 Adaptor required when temperature of the medium < 5 C 0510480001 Auxiliary change-over contacts, single 0510480002 Auxiliary change-over contacts, double A Auxiliary change-over contacts: Infinitely variable 0...100%, admissible load 5(2) A, 24...230 V Description of operation Depending on the type of connection (see connection diagram), the actuator can be used as a continuous 0...10 V, 2-point (OPEN/CLOSE) or 3-point actuator with an intermediate position (OPEN/STOP/CLOSE). The running time of the actuator can be set with the coding switch according to requirements. The coding switch can be used to select the equal-percentage, linear or quadratic characteristic. The AKM 115 is combined with ball valves that have an equal-percentage basic characteristic like the VKR or BKR. The manual adjustment is performed by releasing the gear unit (slide switch beside the connection cable) and simultaneously turning it with the lever. The actuator position can be determined by looking at the lever or the indicator knob on the top part of the actuator. ) Note After manually adjusting the slide switch, put it back into its original position (engage gear unit). Intended use This product is only suitable for the purpose intended by the manufacturer, as described in the Description of operation section. All related product regulations must also be adhered to. Changing or converting the product is not admissible. Additional technical data The upper section of the housing with the cover, indicator knob and cover knob contains the stepping motor and the SUT electronics. The lower section of the housing contains the maintenance-free gear unit. Auxiliary change-over contacts: Switch rating max. 230 V VAC, current min. 20 ma at 20 V Switch rating max. 4...30 V VDC, current 1...100 ma Power consumption Type Running time [s] Status Active power P [W] Apparent power S [VA] AKM105SF132 35 Operation 2.45 4.75 AKM115SF132 Standstill 0.35 0.8 60 Operation 4.9 8.7 Standstill 0.35 0.75 120 Operation 2.25 4.3 Connection as 2-point actuator Standstill 0.35 0.75 This OPEN/CLOSE activation can be performed via 2 cables. The actuator is connected to the voltage via the blue and brown cables. The control passage of the ball valve is opened by connecting the voltage to the black cable. After this voltage is switched off, the actuator moves to the opposite end position and closes the ball valve. 2/7 Right of amendment reserved 2017 Fr. Sauter AG

The unused red and grey wires must not be connected or come into contact with other cables. We recommend that you insulate these. Connection as 3-point control unit When voltage is applied to the cable (brown or black), the ball valve is moved to any desired position. Direction of rotation (viewing the spindle of the ball valve from the actuator): The stem turns in the clockwise direction, with voltage on the brown cable, and closes the ball valve. The stem turns in the anti-clockwise direction, with the voltage on the black cable. In the end positions (limit stop in actuator, max. angle of rotation of 95 reached) or in the case of an overload, the electronic motor cut-off is activated (no limit switches). Direction of rotation changed by transposing the connections. The unused red and grey wires must not be connected or come into contact with other cables. We recommend that you insulate these. Connection for control voltage 0...10 V The built-in positioner controls the actuator depending on controller s output signal y. Direction of rotation (viewing the spindle of the ball valve from the actuator): Direction of operation 1 (mains power supply on brown cable): When the positioning signal is increasing, the carrier stem turns in the anti-clockwise direction and opens the control passage of the ball valve. Direction of operation 2 (mains power supply on black cable): When the positioning signal is increasing, the carrier stem turns in the clockwise direction and closes the control passage of the ball valve. The starting point and control span are fixed. ly the brown cable or the black cable may be connected to the voltage. The cable not used must be insulated (if not connected via switch). As the starting point and the control span are defined as fixed values, a split-range unit is available (accessory) for setting partial ranges. After a manual adjustment or a power failure of more than at least 5 min, the actuator automatically readjusts itself, always with a running time of 60 s. After the power supply is connected, the stepping motor moves to the 100% position, makes the connection with the carrier stem, and then moves to the 0% position and thus defines the working range. After this, every position between a 0 and 90 angle of rotation can be achieved, depending on the control voltage. Thanks to the electronics, no steps can be lost, and the actuator does not require periodic re-adjustment. It is possible to operate multiple actuators of the same type in parallel. The feedback signal y0 = 0...10 V corresponds to the effective angle of rotation of 0 90. When control signal 0 10 V is interrupted and direction of operation 1 is connected, the ball valve is closed completely (0% position). The coding switch can be used to select the characteristic of the ball valve. Characteristics can only be generated when the actuator is used as a continuous actuator. The running times can be selected with additional switch settings. These can be used regardless of whether the 2-point, 3-point or continuous function is selected. Right of amendment reserved 2017 Fr. Sauter AG 3/7

Coding switch for running time and characteristic selection switch position Y01955 M Y07552 M Y01852 running time/angle of rotation s/90 120 s ± 4 120 s ± 4 stroke 120 s ± 4 Signal 60 s ± 2 60 s ± 2 stroke 60 s ± 2 Signal 35 s ± 1 stroke 35 s ± 1 Signal Split-range unit, accessory 0361529 001 Starting point U 0 and control span U can be set with the potentiometer. In this way, several control units can be operated by the control signal in sequence or in cascade. The input signal (partial range) 4/7 Right of amendment reserved 2017 Fr. Sauter AG

is amplified into an output signal of 0...10V. This accessory cannot be built into the actuator but must be externally housed in an electrical junction box. CASE Drives PC Tool, accessory 0372462 001 CASE Drives allows you to set and read the actuator parameters on site. The connection is via a serial port on the PC (laptop) and a socket contact on the actuator. The set consists of: The software including installation and operating manual, fitting instructions, connection plug, cable (1.2 m long) and interface converter for the PC. The application is designed for commissioning and service engineers as well as experienced operators. The last setting has priority, whether made with the coding switch or CASE Drives. When a changeover is made with the coding switch, this setting is active. In order that the settings made with CASE Drives cannot be overwritten, the coding switch can be removed before the setting (delivery includes special tool). Notes on engineering and installation Condensate, dripping water, etc. must be prevented from entering the actuator along the carrier stem. When connecting the electricity supply, ensure that the cross-section of the power cable is adapted to the power output and the length. However, we recommend a minimum cross-section of 0.75 mm². The actuator/ball valve is mounted by inserting and turning the bayonet ring until the limit stop without any additional adjustment. No tools are required. The coupling of the spindle of the ball valve with the carrier stem is performed automatically, either by moving the manual adjuster to an angle of rotation of 100% or connecting the voltage. For dismantling, the bayonet ring is simply opened and the actuator removed. The device is delivered ex works in the middle position. The concept of stepping motor and electronics enables parallel operation of multiple actuators of the same SUT type. If a potentiometer is required, the accessory of the AVM 105, 115 can be used - the display (% angle of rotation) on the type plate is inverted. The maximum accessory equipment for an actuator is 1 auxiliary change-over contact or 1 potentiometer. The auxiliary change-over contact accessory is screwed onto the top cover of the actuator. To be able to make the mechanical connection, you first have to remove the indicator knob. A new indicator can be seen on the cover of the accessory. The coding switches are accessible via an opening with a black cover in the housing lid. Note The housing must not be opened. Outdoor installation We recommend protecting the devices from the weather if they are installed outside buildings. Disposal When disposing of the product, observe the currently applicable local laws. More information on materials can be found in the Declaration on materials and the environment for this product. Connection diagram y=0...10 V 24 V~/= y0=0...10 V Variante 1 (3pt) 24 V~/= open/stop/close BU BN BK RD GY RD = red BN = brown BK = black BU = blue GY = grey BU BN BK RD GY MM 01 02 03 05 MM 01 02 03 05 A/D P Variante 2 (2pt) open / close 24 V~/= M BU BN BK RD GY MM 01 02 03 05 Right of amendment reserved 2017 Fr. Sauter AG 5/7

Accessories 0510480 001 RD BN BK 0510480 002 RD BN BK GN GY VT RD = red BN = brown BK = black GN = green GY = grey VT = violet 0313529 24V~ y 0...10 V 1 2 3 33 A/B Uo U 1 2a 3u MM 01/02/LS 03 AVM...S AVF... S ASF... S AXM...S ASM...S AKM...S Dimension drawing 6/7 Right of amendment reserved 2017 Fr. Sauter AG

Accessories 0510420001 Z10222 60 Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61-695 55 55 www.sauter-controls.com Right of amendment reserved 2017 Fr. Sauter AG 7/7