IDH MAX & IDH MAX 1300 COMPARISON CHART IDH MAX COMPARISON CHART

Similar documents
W & M SERIES: IDH MAX & ELECTROMECHANICAL LOCKS. W & M Series. IDH MAX & Electromechanical Locks. BEST: Setting the Standard for Security

W & M SERIES IDH MAX & Electromechanical Locks

ELECTROMECHANICAL LOCKS ELECTROMECHANICAL LOCKS

CONTENTS GETTING STARTED 1 1 FUNCTIONS AND PARTS LISTS K Series Service Manual

CONTENTS FIGURES GETTING STARTED 1 1 FUNCTIONS AND PARTS 2 1. IDH Max Service Manual

Operation. Smooth. ML2000 Series Mortise Lock

Standard Lever Designs

Product Catalog Series High Security Mortise Lock and M-9200 Series MOGUL Institutional Mortise Lock

8K SERIES: HEAVY DUTY CYLINDRICAL LOCKS KNOBS. 8K Series. Heavy Duty Cylindrical Locks Knobs. BEST: Setting the Standard for Security

Small Format Interchangeable Core (SFIC) Cylinders

KEYPAD EZ LOCKS KEYPAD EZ LOCKS

High Security Mortise Lock and M-9200 MOGUL Institutional Mortise Lock

Lock Functions Single Cylinder Deadbolt Functions

MODELS TRUE WOOD DOOR OPERATIONAL HARDWARE EXIT DEVICE MODELS LEVER X LEVER MODELS DOORS WITH FLUSHBOLTS:

MA Series Grade 1 mortise lever and knob locks

ADDITIONAL INFORMATION

D9300 ELECTRIC MAXI-MORTISE

The Standard Collection Built on our tradition of raising industry standards.

- Available in 7 BHMA finishes - 605, 606, 613, 625, 626, 629, 630

MLR Series Institutional Life Safety Mortise Locksets Levers

MB1 Series ANSI Grade 1 Extra Heavy Duty Lever Locks

Specifications & Certifications

Yale Nomenclature midwestwholesale.com. Yale FL

Yale Nomenclature midwestwholesale.com. Yale FL

7KC SERIES: MEDIUM DUTY CYLINDRICAL LOCKS LEVERS. 7KC Series. Medium Duty Cylindrical Locks Levers. BEST: Setting the Standard for Security

CL3200 Series. Security Bolt Lever Lockset

Olympian 100, 200, 300 Series

OLYMPIAN 100, 200, 300 SERIES PRECISION HARDWARE

3400 Series

9K SERIES: HEAVY DUTY CYLINDRICAL LOCKS LEVERS. 9K Series. Heavy Duty Cylindrical Locks Levers. BEST: Setting the Standard for Security

H E A V Y D U T Y L. Page Features...2 Specifications...3 How to Order...3 Trim Variations...4 Options/Features...5 Service Equipment...

ED5470 Panic-Listed Surface Vertical Rod Exit Device ED5470B 1-1/2 Hour Fire-Listed Surface Vertical Rod Exit Device

M-Series Service Manual

Overview ML2000. Table of Contents

ADDITIONAL INFORMATION

MODELS METAL DOOR OPERATIONAL HARDWARE EXIT DEVICE MODELS LEVER X LEVER MODELS DOORS WITH PUSH OR PULL OPERATION: DOORS WITHOUT TRIM:

Concealed Vertical Rod Features

RU Series MA161 F 31 Connecting room/exit lock Latch bolt operated by knob/lever from inside. No trim outside. Auxiliary dead latch.

RETRO SOLUTIONS PRODUCT CATALOG

Locks TABLE OF CONTENTS. A Armor Fronts (Mortise)

CK4400 Series. Standard Duty Cylindrical Knob Locksets

CYLINDRICAL ADAPTATION LOCKS. Cylindrical Adaptations. Cylindrical Adaptation Locks. BEST: Setting the Standard for Security

Specifications & Certifications

Overview ML2000. Table of Contents

Grade 1 Heavy-Duty Cylindrical Locksets DORMA CL800 CK800

3800 Series

1010A DEADLOCK DOOR MOUNTED FOR SMALL SWINGING DOORS APPLICATION: FUNCTION: CRAFTMASTER HARDWARE CO., INC

Specifications & Certifications

Wadsworth Security Products

Security-Mate Cylinders. Maxwell Lever #77 RQ Small Rose With Ring Design

Overview ML2000. Table of Contents

6200 Series. Strikes for mortise or cylindrical devices. Features and benefits. Overview

Entry. Entry. Entry. Entry

Application. Security Knob trim available. Safety Knob (optional)

S200-SERIES. Interconnected Entrance Locks

Series SS19 Institutional Life Safety Mortise Locksets - Levers

L-Series Commercial Locks

Standard-Duty Key-In-Lever Locksets. CL3900 Series

W Series Cylindrical Lever. W Series cylindrical lever lock

8800 series grade 1 mortise locks

Deadbolt by key outside. Thumbturn lever inside retracts deadbolt only; will not project deadbolt.

Series 5SS19 Institutional Life Safety Mortise Locksets - Levers

MA Series. Mortise Lockset Functions. MA101 FO1 Passage Latchset Latchbolt by knobs/levers at all times.

CL33900 Electrified Lockset

8800 series grade 1 mortise locks

CYLINDRICAL ADAPTATION LOCKS CYLINDRICAL ADAPTATION LOCKS

Behavioral Healthcare Solutions

20 Series. Exit Device

Specifications & Certifications

Overview ML2000. Table of Contents

MA Series. Mortise Lockset Functions. MA101 FO1 Passage Latchset Latchbolt by knobs/levers at all times.

7KC Once installed, no complex disassembly is required to remove the lever. Lever cannot be removed without a key.

5/8" Radius Corner Hinges

Table Of Contents. 30 Series Exit Device. On The Cover

Locksets. Requirements. Approved Manufacturers. Schlage D Series Rho Trim No Substitution Cylinders Medeco No Substitution

STANLEY COMMERCIAL HARDWARE. Full Line Catalog. STANLEY Commercial Hardware. Trusted experts. Proven reliability. Simply STANLEY.

Simplex. Cylindrical Knob Series. Grade 1 Extra Heavy Duty Cylindrical Knob

Rim Trims and Functions

Optional Latchbolts /8" (60 mm) Square or Round Corner, Dead Latch /4" (70 mm) Square or Round Corner, Dead Latch - Standard

GRADE 1 ELECTRIFIED CYLINDRICAL & UNIT LOCKS

2904 Power Supply Installation Instructions I-EA00041

L-Series Commercial Locks

FEATURES & SPECIFICATIONS. 100% internal parts quality inspection provides security, reliability and durability

CL3800 Series. Standard-Duty Key-in-Lever Locksets

Table of Contents 20 Series Exit Device

E SERIES Mortise and Rim Cylinders

SARGENT 8200 Nomenclature

M9000. Grade 1 Heavy-Duty Mortise Locksets

RETRO SOLUTIONS PRODUCT CATALOG

Auxiliary Locks. Deadlocks and Deadbolts. Falcon Monarch Dor-O-Matic

Spectra Class. N6000 Series Exit Devices SECURITY DOOR CONTROLS. N6100 Rim Mount Exit Device. N6200 Surface Vertical Rod Exit Device.

FOLGER ADAM PRICE LIST

ED8000 Series. Pushpad Exit Devices

CL3500 Series. Heavy-Duty Cylindrical Lever Lockset

3200 Series Cylindrical Lock

2010 Product Line Catalog

L Series. Commercial mortise locks

7800 / Series Mortise Lock

ML2000 Series. Mortise Locksets

APEX 2000 SERIES: TOUCHBAR EXIT DEVICES. Apex 2000 Series. Touchbar Exit Devices. Strength by design. Simply PRECISION

Transcription:

IDH MAX & IDH MAX 1300 COMPARISON CHART IDH MAX COMPARISON CHART IDH MAX IDH MAX 1300 1. Prep door for IDH MAX 2. Run single 4 conductor wire for IDH MAX 3. Install IDH MAX 4. Install electrified hinge 5. Mount PIM * Operates with most control panel hardware, including B.A.S.I.S. control panels. 1. Prep door for IDH MAX 2. Run single 4 conductor wire for IDH MAX 1300 3. Install IDH MAX 1300 which includes Intelligent System 4. Install electrified hinge ** Operates with B.A.S.I.S. control panels only. HM, KM, HW & KW OPTIONS AL Besides complying with a wide variety of accessibility codes and ordinances, lever handles are available with a special abrasive feature. Abrasive strip on the lever im me di ate ly identifies warnings on doors to hazardous areas for the blind. BRK When excessive force (approx. 300 inch lbs.) is applied to #4, #6 keyed knobs, they breakaway and spin freely, thus allowing entrance only by key. Simple part replacement s lock to func tion al usage. C The easy to use quick connect system enables efficient installation to the respective BEST Lock electrical options ordered. IDH The Integrated Door Hardware groups three components into one hardware package. 1. Door status switch (normally closed) 2. Request-to-Exit switch (normally open) 3. Electrically controlled locking mechanism. KNL Knurl feature is available only on #6 knobs. The knurling is machined into the outer edge of the knob. The knurled feature can be used for blind, safety, or accessibility applications. LL Lead lined feature can be used to protect against X-rays. Since the majority of lead lined doors contain the lead in the surface of the door, the knob lockset provide lead lining for the holes cut in the door when preparing the door for the trim. LM The Lost Motion feature allows the lever handle to turn freely when it is locked without retracting the latchbolt assembly. This feature makes over-torque abuse more difficult to achieve. SH Security head provided for all exposed screws. RQE Cylindrical or Mortise locksets can be supplied with a request-to-exit switch. A normally open switch provides momentary switch closure when the inside lever/knob is rotated. TAC Grooves are machined into knobs to improve grip or to be used as a warning in hazardous areas. This option can be used for blind, safety or accessibility applications. Thick door Specify thickness if other than 1 3 4. TL Tactile levers may be used in areas where improved grip is required or as a warning in hazardous or Safety First areas. Grooves are machined into the back of the hand grasp portion of the lever to improve grip and/or provide a sensory warning. This option can be used for blind, safety, or accessibility applications. 1300 Integrated BAS1300/LNL1300 reader electronics board or (ISC) Intelligent System Controller is embedded behind the escutcheon d and out of site. Functions with B.A.S.I.S./Mercury on-line equipment only. NOTE: 1300 option not available on any EL electrically locked functions. HM, KM, HW KW OPTIONS 3

9KM IDH MAX FUNCTIONS DDEL Locked Rotating the inside knob/ the Removing power from the Cannot be locked lever, ; remains locked Rotating the outside knob/ while power. lever only when power is off, Turning the key in the outside knob/lever. deadlocked Powered by 12V DC. Temperature control module (TCM) is not needed. DDEU Unlocked Rotating the inside knob/ lever, Rotating the outside knob/ lever only when power is on, Turning the key in the outside knob/lever. deadlocked Removing power from the Powered by 12V DC. Temperature control module (TCM) is not needed. Shading indicates a ridged lever/knob in a non-energized state. the ; remains unlocked while power. Cannot be locked 9KM IDH MAX -FUNCTIONS 40HW/8KW/9KW ELECTRIFIED LOCK INTRODUCTION The 40HW, 8KW, and 9KW electromechanical locks provide fail-safe (electrically locked) and fail- (electrically unlocked) operation. They also provide a way to lock and unlock the door from a remote location for safety, security, or convenience through an individual switch, switch lock, relay, access control system, or other automatic control system. More importantly, these locks exhibit the same features and meet the same standards and specifications as our mechanical 40H mortise and 8K/9K heavy duty cylindrical locksets. HOW TO ORDER STANLEY QUICK CONNECT PRE-WIRED PLUG-IN CONNECTORS To order the Stanley Quick Connect pre-wired plug-in connectors, include the C suffix for the BEST Locks. See page 20 for more details on how the Stanley Quick Connect systems works. Example: BEST Locks 45HW 7 DEL 14H 626 RH DS C BEST Locks 9KW 37 DEU 15CS TK 626 24 V C 40HW ELECTRIFIED SPECIFICATIONS Types: 12 volts AC or DC 0.60 amps 24 volts AC or DC 0.45 amps All EU functions: Electrically Unlocked () All EL functions: Electrically Locked () Approval Listings: UL listed for GYQS Electrically-controlled singlepoint locks or latches. This product has been approved by the California State Fire Marshal (CSFM) pursuant to section 13144.1 of the California Health and Safety Code. Approved by the city of New York Board of Stan dards and Appeals under calendar number 49-88-SA. See CSFM listing No. 4136-1175:101 for al low able values and/or conditions fo use concerning material pre sent ed in this doc u ment. It is subject to re-examination,revisions and possible cancellation. NOTE: All w-series locks require the use of a (TCM) Temperature Control Module. TCM and TCM connector are supplied standard with every order. 40HW Mortise Electrically-Operated Lockset 40HW ELECTRIFIED- ISPECIFICATIONS ELECTRIFIED INTRO & QUICK CONNECT 7

40HW ELECTRIFIED HOW TO ORDER 40HW ELECTRIFIED HOW TO ORDER 45HW 7 NXEU 12 J 612 LH RQE Series 45HW lever 47HW lever high security Core Housing 0 keyless or less cylinder, 7 7 pin IC housing accepts all BEST cores 7 7 pin (accepts 5C cores only) Function 45HW/ DEL single key latch, fail safe DEU single key latch, fail WEL double key latch, fail safe WEU double key latch, fail TDEL single key deadbolt, fail safe TDEU single key deadbolt, fail TWEL double key deadbolt, fail safe TWEU double key deadbolt, fail 45HW only: NXEL keyless, latch, fail safe NXEU keyless, latch, fail LEL keyless, deadbolt, fail safe LEU keyless, deadbolt, fail * N trim not available on double keyed functions. See H Series catalog for details. Lever Style Levers 3 solid tube/ 12 solid tube/ no 14 curved 15 contour/ angle 16 curved/no 17 gullwing no Knobs: 4 round Trim Style H 2 3 /4 flat J wrought M forged N forged concealed cylinder* S 3 1 /2 flat R 2 3 /4 concave M forged Finishes Handing Options 605 606 611 612 613 618 619 625 626 690 626 630 RH RHRB LH LHRB AL abrasive lever C quick connect LL lead lined LS latch status DS door status RQE request to exit SH security head screws TL tactile lever Thick Door specify thickness if other than 1 3 /4 (1 3 /4 min x 4 max) 12V Specify 12 Volt System (standard lock voltage is 24V) (pages 8 9) (page 11) (page 11) (page 3) DEL Locked Removing power from Cannot be locked DEU Unlocked WEL Locked Outside knob/lever when power is removed from the ; remains locked while power Outside knob/lever when Removing power from ; remains Cannot be locked power is applied to the unlocked while power Inside and Outside knob/lever when power is removed from the Inside/Outside key ; Removing power from the ; remains locked while power Removing power from the WEU Unlocked Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Applying voltage locks inside & outside knobs/levers simultaneously. Inside and Outside Removing power from ; remains Removing power from knob/lever when power is unlocked while power ; remains applied to the unlocked while Inside/Outside key power Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Removing voltage locks inside & outside knobs/levers simultaneously. 8 IDH MAX & ELECTROM

(CONTINUED) TDEL Locked Removing power from Cannot be locked TDEU Unlocked TWEL Locked TWEU Unlocked NXEL Locked NXEU Unlocked LEL Locked LEU Unlocked Outside knob/lever when power is removed from the ; Deadbolt operated by: Deadbolt and latchbolt retracted simultaneously by: removed. Removing power from ; remains Cannot be locked Outside knob/lever when unlocked while power power is applied to the Deadbolt and latchbolt Deadbolt operated by: retracted simultaneously by: applied. Outside & inside key Outside & Inside knob/ lever when power is removed from the ; Removing power from Deadbolt operated by: Outside or inside key Outside & Inside knob/lever when power is removed from the ATTENTION: Locksets that both sides of the door are controlled by building codes and the Life Safety Code. In an emergency exit situation, failure to quickly unlock the inside lever could be hazardous or even fatal. ; remains locked while power is on Removing power from Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Applying voltage locks inside & outside knobs/levers simultaneously. Outside & inside key Removing power from ; remains Removing power from Outside & Inside knob/ unlocked while power ; remains lever when power is unlocked while applied to the Deadbolt operated by: power Outside or inside key Outside & Inside knob/lever when power is applied to the Powered by 12 or 24 volts AC/DC & 0.60 or 0.45 amps, continuous duty. Removing voltage locks inside & outside knobs/levers simultaneously. Outside knob/lever when Removing power from Cannot be locked power is applied to the ; remains locked while power Outside knob/lever when Removing power from ; remains Cannot be locked power is applied to the unlocked while power Outside knob/lever when the Removing power from the Cannot be locked power is removed from ; remains locked Deadbolt retracted by: the while power retracts Deadbolt extended by: the deadbolt and latchbolt Inside thumb turn simultaneously removed Outside knob/lever when power is applied to the Removing power from the Deadbolt extended by: Inside thumb turn the ; remains unlocked while power Deadbolt retracted by: retracts the deadbolt and latchbolt simultaneously Outside knob/lever when power is applied Cannot be locked 9

KNOB STYLES #4 knob #6 knob LEVER STYLES #3 lever #12 lever #14 lever LEVER STYLES KNOBS #15 lever #16 lever #17 lever MORTISE ROSE TRIMS CYLINDRICAL ROSE TRIMS H rose R rose S rose C rose D rose K rose L rose ESCUTCHEON TRIM VARIATIONS ROSES TRIMS ESCUTCHEON TRIM J escutcheon M escutcheon N escutcheon MS escutcheon Prox escutcheon 11