PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

Similar documents
PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

Ordering Information. Text Surface-Mounting Signal Relay G6K

Ordering Information. Text PCB Power Relay G5LE

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Model Number Structure

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Model Number Structure

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

General Purpose Relay

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Type Terminal Coil Contact form Model

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

General Purpose Relay

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

The full feature relay includes the combination for rotary button or plain button or light or indicator flag.

Subminiature Basic Switch

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

General Purpose Relay

Mechanical Key Switch

Model Number Structure

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

Surface mounting, flush mounting, and DIN track mounting

1 Form A 5A small size power relay for interface

Model Number Structure

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Safety-door Switch. Ordering Information

Inductive Proximity Sensor

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

Power Contactor with Mirror Contacts

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Switching Power Supply

Industrial Relay KML(1C, 2C)

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

Features. * 2 Form C contact. * High switching capacity 60W, 125VA. * Fit standard 16 pin IC socket. * Epoxy sealed for automaitc-wave COIL

15A (2 Form C), 10A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY

Switching Power Supply

H3DS-X - Solid State Two-Wire Timer

2c 15A, 4c 10A polarized power relays

Tactile Switch (Hinged Type)

A22NK. Key-type Selector Switches

Analog Output Terminal

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Transistor Remote Modules

Hinged Safety Door Switch

Manual Reset Limit Switch

Safety Interlock Switches

General Purpose Relay

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

Scheda prodotto Relè Series E

5 mm contact pin pitch PCB or 95 series sockets

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Model Number Structure

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Safety Limit Switch

Lighted PushButton Switch

Small Limit Switch D4V

Type List. Standard Type. High Power Type

Analog Input Terminal

Lighted Pushbutton Switch

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Selection Guide Automotive Relays

DATA SHEET. Compact and lightweight, High breakdown voltage, Surface mounting type

Power Controller. (see note 1) 10 sec

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

55 Series - Miniature General Purpose Relays 5-10 A

Type List. Standard Type. High Power Type. Designation (provided with) Terminal style Contact form Contact gap

Transcription:

PCB Relay Ultracompact, Ultrasensitive DPDT Relay Compact size and low 5-mm profile. Low power consumption (140 mw for single-side stable, 100 to 300 mw for latching type) and high sensitivity. Low thermoelectromotive force. Low magnetic interference enables high-density mounting. Single- and double-winding latching types also available. RC Ordering Information DPDT Classification Single-side stable Single-winding latching Double-winding latching Fully PCB terminal -2 U-2 K-2 sealed Surface mount terminal -2F --- --- Note: When ordering, add the rated coil voltage to the model number. Example: K-2 12 VDC Rated coil voltage Model Number Legend - - VDC 1 2 3 4 5 1. Relay Function None: Single-side stable U: Single-winding latching K: Double-winding latching 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal 4. Classification U: Ultrasonically cleanable 5. Rated Coil Voltage 3, 5, 6, 9, 12, 24 VDC Specifications Coil Ratings Single-side Stable Type (-2, -2F) Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC Rated current 46.7 ma 28.1 ma 23.3 ma 15.5 ma 11.7 ma 8.3 ma Coil resistance 64.3 W 178 W 257 W 579 W 1,028 W 2,880 W Coil inductance Armature OFF 0.025 0.065 0.11 0.24 0.43 1.2 (H) (ref. value) Armature ON 0.022 0.058 0.09 0.20 0.37 1.0 Must operate voltage 75% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 200% of rated voltage at 23 C 170% of rated voltage at 23 C Power consumption Approx. 140 mw Approx. 200 mw Note 48 VDC (single-side stable) model is also available. Consult OMRON for details.

Single-winding Latching Type (U-2) Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC Rated current 33.3 ma 20 ma 16.7 ma 11.1 ma 8.3 ma 6.25 ma Coil resistance 90 W 250 W 360 W 810 W 1,440 W 3,840 W Coil inductance Armature OFF 0.034 0.11 0.14 0.33 0.60 1.6 (H) (ref. value) Armature ON 0.029 0.09 0.12 0.28 0.50 1.3 Must operate voltage 75% max. of rated voltage Must release voltage 75% min. of rated voltage Max. voltage 180% of rated voltage at 23 C Power consumption Approx. 100 mw Approx. 150 mw Double-winding Latching Type (K-2) Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC Rated current 66.7 ma 40 ma 33.3 ma 22.2 ma 16.7 ma 12.5 ma Coil resistance 45 W 125 W 180 W 405 W 720 W 1,920 W Coil inductance Armature OFF 0.014 0.042 0.065 0.16 0.3 0.63 (H) (ref. value) Armature ON 0.0075 0.023 0.035 0.086 0.16 0.33 Must operate voltage 75% max. of rated voltage Must release voltage 75% min. of rated voltage Max. voltage 160% of rated voltage at 23 C 130% of rated voltage at 23 C Power consumption Approx. 200 mw Approx. 300 mw Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23 C. Contact Ratings Load Resistive load (cosf = 1) Rated load 0.5 A at 125 VAC; 1 A at 30 VDC Contact material Ag (Au-clad) Rated carry current 1 A Max. switching voltage 125 VAC, 110 VDC Max. switching current 1 A Max. switching power 62.5 VA, 33 W Failure rate (reference value) 10 µa at 10 mvdc Note P level: l 60 = 0.1 x 10 6 /operation

Characteristics Contact resistance Approved Standards 50 mw max. (-2-U: 100 mw max.; -2F: 60 mw max.) Operate (set) time Single-side stable types: 3 ms max. (mean value: approx. 2 ms) Latching types: 3 ms max. (mean value: approx. 1.5 ms) Release (reset) time Single-side stable types: 2 ms max. (mean value: approx. 1 ms) Latching types: 3 ms max. (mean value: approx. 1.5 ms) Bounce time Operate: Approx. 0.5 ms Release: Approx. 0.5 ms Set/reset: Approx. 0.5 ms Min. set/reset signal width Latching type: 5 ms min. (at 23 C) Max. operating frequency Mechanical: 36,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance 1,000 MW min. (at 500 VDC) Dielectric withstand voltage 1,000 VAC, 50/60 Hz for 1 min between coil and contacts 1,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 750 VAC, 50/60 Hz for 1 min between contacts of same polarity Impulse withstand voltage 1,500 V (10 x 160 µs) between contacts of same polarity (conforms to FCC Part 68) Vibration resistance Destruction: 10 to 55 to 10 Hz, 2.5-mm single amplitude (5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3-mm double amplitude) Shock resistance Destruction: 1,000 m/s 2 Malfunction: 500 m/s 2 Endurance Mechanical: 100,000,000 operations min. (at 36,000 operations/hr) Electrical: 200,000 operations min. (at 1,800 operations/hr) Ambient temperature Operating: -40 C to 70 C (with no icing) Ambient humidity Operating: 5% to 85% Weight Approx. 1.5 g UL114, UL478 (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR31928) -2 U-2 K-2 (U/K)-2-U (U/K)-2-100 Model Contact form Coil ratings Contact ratings DPDT 1.5 to 48 VDC 2 A, 30 VDC 0.3 A, 110 VDC 0.5 A, 125 VAC

Engineering Data Maximum Switching Power Endurance Switching current (A) DC resistive load AC resistive load Endurance (x10 operations) 3 10,000 7,000 5,000 3,000 1,000 700 500 300 30-VDC resistive load 100 125-VAC resistive load Switching voltage (V) Ambient Temperature vs. Maximum Coil Voltage Single-side Stable (-2) Switching current (A) Single-winding Latching (U-2) Double-winding Latching (K-2) Maximum coil voltage (%) 24 VDC 3 to 24 VDC 48 VDC Maximum coil voltage (%) 3 to 24 VDC Maximum coil voltage (%) 3 to 12 VDC 24 VDC Ambient temperature ( C) Ambient temperature ( C) Ambient temperature ( C) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Malfunctioning Shock Resistance (-2) 5 VDC Number of Units: 10 Shock direction NC contact NO contact 2 Condition: The Units were shocked at the rate of 500 m/s three times each in the ±X, ±Y, and ±Z directions with and without voltage imposed on the Units until the Units malfunctioned.

High-frequency Characteristics Frequency vs. Isolation Frequency vs. Insertion Loss Frequency vs. Return Loss, V.SWR Isolation (db) Unit: -2 Number of Units: 5 Insertion loss (db) Unit: -2 Number of Units: 5 Return loss (db) Unit: -2 Number of Units: 5 Return loss Frequency (MHz) Frequency (MHz) Frequency (MHz) Note: The above characteristics were obtained from the Units inserted into test sockets. The characteristics of -2 Units in actual operation may be different from the above characteristics. Check the characteristics of -2 Units under the actual conditions before use. Distribution of Operate and Release Time Distribution of Bounce Time Number of contact Unit: -2 at 5 VDC Number of Units: 50 Operate time Release time Number of contact Unit: -2 at 5 VDC Number of Units: 50 Operate bounce time Release bounce time Time (ms) Time (ms)

Dimensions Note: 1. All units are in millimeters unless otherwise indicated. 2. Orientation marks are indicated as follows: Single-side Stable Type -2(-U) 5.4 max. (5.0)* 3.50.3 2.54 0.5 (9.0)* Terminal Arrangement/ Internal Connections (Bottom View) 1 2 3 4 5-10 9 8 7 6 (1.92) Mounting Holes (Bottom View) Tolerance: ±0.1 2.54 2.54 (1.92) Ten, 1-dia. holes 2.54 2.54 Single-winding Latching Type U-2(-U) 5.4 max. (5.0)* 3.5 2.54 0.5 (9.0)* 1 2 3 4 5 S R - - 10 9 8 7 6 2.54 2.54 (1.92) (1.92) Ten, 1-dia. holes 2.54 2.54 Double-winding Latching Type K-2(-U) 5.4 max. (5.0)* 3.5 2.54 0.5 (9.0)* 1 2 S 3 4 5 10 9 8 R 7 - - 6 2.54 2.54 (1.92) (1.92) Ten, 1-dia. holes 2.54 2.54 Single-side Stable Type -2F 6.6 max. (6.3)* 5.5 max. (5.2) (9.0)* Glue pad ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K042-E1-5A RFD electronic gmbh * An der Kanzel 2 * 97253 Gaukönigshofen * Telefon 09337/971230 * Telefax 09337/9712450