PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Similar documents
PCB Relay. Contact form Terminal Single-side stable Single-winding latching

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Model Number Structure

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Ordering Information. Text PCB Power Relay G5LE

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

Model Number Structure

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Subminiature Basic Switch

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Model Number Structure

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

Switching Power Supply

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

Ordering Information. Text Surface-Mounting Signal Relay G6K

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

Model Number Structure

General Purpose Relay

Mechanical Key Switch

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

General Purpose Relay

The full feature relay includes the combination for rotary button or plain button or light or indicator flag.

Type Terminal Coil Contact form Model

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

General Purpose Relay

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Safety-door Switch. Ordering Information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Inductive Proximity Sensor

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

A22NK. Key-type Selector Switches

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

Model Number Structure

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Tactile Switch (Hinged Type)

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

General Purpose Relay

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Manual Reset Limit Switch

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

Model Number Structure

Model Number Structure

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Switching Power Supply

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

Power Controller. (see note 1) 10 sec

Industrial Relay KML(1C, 2C)

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Analog Input Terminal

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

Small Limit Switch D4V

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Lighted PushButton Switch

D2D. Door Interlock Power Switch with Minimum Contact gap of 3 mm. Model Number Legend. Contact Form. List of Models. Contact Specifications.

Lighted Pushbutton Switch

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

B3F. Miniature, Space-saving Switch

H3DS-X - Solid State Two-Wire Timer

Model Number Structure

Analog Output Terminal

24-hour/Weekly Time Switch H2F

Features. Type List. Ordering Information S - 1A - - C - Contact Rating

A L - J R M - 24D - 2

Inductive Proximity Sensor

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Transcription:

PCB Relay Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current Ideal for motor switching. Miniature, relay with high switching capacity built-in applications. Creepage distance conforms to UL and CSA standards. Highly noise-resistive insulation materials employed. Standard model available with flux protection construction. RCE Ordering Information Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC -1A PCB terminals -1A-P When ordering, add the rated coil voltage to the model number. Example: -1A 12 VDC Rated coil voltage Model Number Legend: - - VDC 1 2 3 4 1. Number of Poles 1: 1 pole 2. Contact Form A: SPST-NO 3. Terminals None:Relays with #250 tab/pcb P: Straight PCB 4. Rated Coil Voltage 5, 12, 24 VDC 1

Specifications Coil Ratings Rated voltage 5 VDC 12 VDC 24 VDC Rated current 180 ma 75 ma 37.5 ma Coil resistance 27.8 Ω 160 Ω 640 Ω Coil inductance Armature OFF --- 0.8 H 3.5 H (ref. value) Armature ON --- 1.1 H 4.8 H Must operate voltage Must release voltage Max. voltage Power consumption 70% of rated voltage max. 10% of rated voltage min. 110% of rated voltage Approx. 0.9 W 1. The rated current and coil resistance are measured at a coil temperature of 23 C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23 C. Contact Ratings Rated load Rated carry current Max. switching voltage Max. switching current Max. switching capacity Min. permissible load 20 A at 250 VAC 20 A 250 VAC 20 A 5,000 VA 100 ma at 5 VDC P level: λ 60 = 0.1 x 10 6 /operation (with an operating frequency of 120 operations/min) Life Expectancies With Motor Load 250 VAC: Inruch current: 80 A, 0.3 s (cosφ= 0.7) Break current: 20 A (cosφ = 0.9) With Overload ON: 1.5 s OFF: 1.5 s 100,000 operations 250 VAC: Inruch current: 80 A (cosφ= 0.7) Break current: 80 A (cosφ = 0.7) With Inverter Load ON: 1.5 s OFF: 1.5 s 1,500 operations 100 VAC; ON: 3 s 30,000 operations Inrush current: 200 A (0 P) OFF: 5 s Break current: 20 A 2

Characteristics Contact resistance Operate time Release time 30 mω max. 20 ms max. 10 ms max. Max. operating frequency Mechanical: 18,000 operations/hr Insulation resistance Dielectric strength Vibration resistance 1,000 MΩ min. (at 500 VDC) 4,500 VAC 50/60 Hz for 1 min between coil and contact 1,000 VAC 50/60 Hz for 1 min between contacts of same polarity Destruction: 10 to 55 Hz, 1.5-mm double amplitude Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Destruction: 1,000 m/s 2 (approx. 100G) Malfunction: 200 m/s 2 (approx. 20G) Life expectancy Mechanical: 2,000,000 operations min. (at 18,000 operations/hr) Motor load: 100,000 operations min. (ON/OFF: 1.5 s) Inverter load: 30,000 operations min. (ON: 3 s, OFF: 5 s) Ambient temperature Operating: 20 C to 55 C (with no icing) Ambient humidity Operating: 35% to 85% Weight Approx. 23 g The data shown above are initial values. Engineering Data Max. Switching Capacity Switching current (A) AC inductive load cosφ = 0.4 AC resistive load Life Expectancy Life expectancy (x10 operations) 3 5,000 3,000 1,000 700 500 300 100 70 50 250-VAC inductive load cosφ = 0.4 250-VAC resistive load Switching voltage (V) Switching current (A) Dimensions All units are in millimeters unless otherwise indicated; dimensions shown in parentheses are in inches. 3

-1A 30.5 max. (30.1)* 16 max. (15.7)* Mounting Holes Four, 1.8 +0.1 0 dia. 23.5 max. (23.3)* Terminal Arrangement /Internal Connections (Top View) *Average value Tab Terminal PCB Terminal -1A-P 30.5 max. (30.1)* 16 max. (15.7)* Mounting Holes Four, 1.8 +0.1 0 dia. 26.8 max. (26.5)* Terminal Arrangement /Internal Connections *Average value 4

Precautions Mounting When mounting two or more relays side by side, provide a minimum space of 3 mm between relays. Terminal Connection The terminals fit FASTON receptacle 250 and are suitable for positive-lock mounting. Do not apply excessive force on the terminals when mounting or dismounting the relay. The following positive-lock connectors made by AMP are recommended. Type Receptacle terminals Positive housing #250 terminals (width: 6.35 mm) AMP 170333-1 (170327-1) AMP 170334-1 (170328-1) AMP 170335-1 (170329-1) The numbers shown in parentheses are for air-feeding. AMP 172076-1 natural color AMP 172076-4 yellow AMP 172076-5 green AMP 172076-6 blue ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J56-E1-2 5