K26M POWER 240 MONO 230 MONO 220 MONO

Similar documents
K17M POWER 240 MONO 230 MONO 220 MONO

J66K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J165K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KK44 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K20UM POWER 240 MONO-BI

J60U GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J220K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

T16K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K12. Optional Control Panel POWER K12

Optional Control Panel POWER

V275C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KH275. Frequency (Hz) Optional control panel POWER. Voltage

KV500C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION. Soundproof version with CE directive (CN09 option) Type soundproofing

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Optional control panel POWER. Voltage

KV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KM44. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel POWER

J80UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J200UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K28H GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KM33. Frequency (Hz) Voltage (V) Standard control Panel Optional control panel Optional control Panel POWER

D330 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V700C2. Optional Control Panel POWER. Voltage. DIMENSIONS COMPACT VERSION 24 V charge alternator and starter

ENGINE CHARACTERISTICS

KV550C2. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

KD165. Engine type Alternator type Performance class. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel

X800 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KV550C2. Optional control panel POWER

KV500UC2. Frequency (Hz) Voltage (V) Standard Control Panel Optional control panel Optional control panel Optional control panel POWER

T1400. Standard Control Panel POWER. Voltage. kw e 415/24 400/23 380/22

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

GZ50 POWER. Fuel System 50 Hz:

KM2500. Engine type Alternator type Performance class

X1100C GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE

GZ25 POWER. Fuel System 50 Hz:

KX1100. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

V550C2 GENERAL CHARACTERISTICS POWERS DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

GZ40 POWER. Fuel System 50 Hz:

Engine type Alternator type Canopy Type GENERAL CHARACTERISTICS

Engine type Alternator type Canopy Type GENERAL CHARACTERISTICS

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Type Dimensions Weight Tank Length: 6400mm 8709kg [19200lbs] [252in] Net 930 L 10000kg [22046lbs] Heigth: 2721mm Gross [107in]

Type Dimensions Weight Tank Length: 6400mm 7836kg [17275lbs] [252in] Net 930 L 9020kg [19886lbs] Heigth: 2721mm Gross [107in]

TERM OF USE Standard reference conditions ESP/PRP 27 C /40 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

TERM OF USE Standard reference conditions ESP/PRP 25 C /25 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

Engine JOHN DEERE, 4045HFS83, U.S. EPA Tier 3 Alternator LEROY SOMER, LSA442VS45 <Debut> 100KW GENERATOR

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

ENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

USP&E Cummins Series Diesel Generator Set

WPS20/S EP Series. Features:

USP&E Cummins Series Diesel Generator Set

WPS60/S EP Series. Features:

USP&ECummins Series Diesel Generator Set

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

WPS150/S EP Series. Features:

WPS100/S EP Series. Features:

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

WPS350/S EP Series. Features:

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GMS200C/S EC Series. Features:

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

GMS100C/S EC Series. Features:

USP&E Cummins Series Diesel Generator Set

WPS250/S EP Series. Features:

USP&E Cummins Series Diesel Generator Set

Transcription:

Engine ref. Alternator ref. Performance class GENERAL CHARACTERISTICS Frequency (Hz) Voltage (V) Standard Control Panel Optional control panel KDI2504TM-30 KH00500T G3 50 Hz 230 single phase APM303 APM403 POWER Voltage ESP PRP kwe kva kwe kva Standby Amps 240 MONO 230 MONO 220 MONO 26 26 23,6 23,6 108 26 26 23,6 23,6 113 26 26 23,6 23,6 118 DESCRIPTIVE Mechanic governor Mechanically welded chassis with antivibration suspension Main line circuit breaker Radiator for core temperature of 48/50 C max with mechanical fan Protective grille for fan and rotating parts (CE option) 9 db(a) silencer supplied separately Charger DC starting battery with electrolyte 12 V charge alternator and starter Delivered with oil and coolant -30 C Manual for use and installation POWER DEFINITION PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed. TERMS OF USE According to the standard, the nominal power assigned by the genset is given for 25 C Air Intlet Temperature, of a barometric pressure of 100 kpa (100 m A.S.L), and 30 % relative humidity. For particular conditions in your installation, refer to the derating table. ASSOCIATED UNCERTAINTY For the generating sets used indoor, where the acoustic pressure levels depends on the installation conditions, it is not possible to specify the ambient noise level in the exploitation and maintenance instructions. You will also find in our exploitation and maintenance instructions a warning concerning the air noise dangers and the need to implement appropriated preventive measures. DIMENSIONS COMPACT VERSION Length (mm) 1700 Width (mm) 896 Height (mm) 1200 Dry weight (kg) 621 Tank capacity (L) 100 DIMENSIONS SOUNDPROOFED VERSION M137 Width (mm) 938 Height (mm) 1285 Dry weight (kg) 809 Tank capacity (L) 100 Acoustic pressure level @1m in db(a) 76 Sound power level guaranteed (Lwa) 90

ENGINE CHARACTERISTICS GENERAL ENGINE DATA Engine brand Engine ref. Air inlet system Cylinders configuration LOMBARDINI KDI2504TM-30 Turbo L EXHAUST Exhaust gas temperature @ ESP 50Hz ( C) 455 Exhaust gas flow @ ESP 50Hz (L/s) 103 Max. exhaust back pressure (mm H2O) 800 Number of cylinders 4 Displacement (L) 2,48 Charge Air coolant Bore (mm) x Stroke (mm) 88 x 102 Compression ratio 18.5 : 1 Speed (RPM) 1500 Pistons speed (m/s) 5,10 Maximum stand-by power at rated RPM (kw) 32 Frequency regulation, steady state (%) BMEP @ PRP 50 Hz (bar) 9,40 Governor type COOLING SYSTEM Mechanical FUEL Consumption @ 100% load ESP (L/h) 8,30 Consumption @ 100% PRP load (L/h) 7,50 Consumption @ 75% PRP load (L/h) 5,70 Consumption @ 50% PRP load (L/h) 4 Maximum fuel pump flow (L/h) 55 OIL Oil system capacity including filters (L) 11,50 Min. oil pressure (bar) 0,70 Max. oil pressure (bar) Oil consumption 100% ESP (L/h) 0,16 Oil sump capacity (L) Radiator & Engine capacity (L) 9,10 HEAT BALANCE Fan power (kw) 0,90 Fan air flow w/o restriction (m3/s) 1,18 Available restriction on air flow (mm H2O) Type of coolant Glycol-Ethylene Heat rejection to exhaust (kw) Radiated heat to ambiant (kw) 5 Heat rejection to coolant HT (kw) 24 AIR INTAKE Max. intake restriction (mm H2O) Intake air flow (L/s) EMISSIONS Emission PM (g/kw.h) 0,60 Emission CO (g/kw.h) 5,50 Emission HC+NOx (g/kwh) 0 Emission HC (g/kw.h)

ALTERNATOR CHARACTERISTICS GENERAL DATA Alternator ref. KH00500T Number of Phase Single phase Power factor (Cos Phi) 1 Altitude (m) 0 à 1000 Overspeed (rpm) 2250 Number of pole 4 Capacity for maintaining short circuit at 3 ln for 10 s Yes Insulation class H T class (H/125 ), continuous 40 C H / 125 K T class (H/163 C), standby 27 C H / 163 K Total Harmonic Distortion in no-load DHT (%) 3,0 AVR Regulation Yes Total Harmonic Distortion, on linear load DHT (%) 1,6 Wave form : NEMA=TIF <45 Wave form : CEI=FHT <2 Number of bearing Single Bearing Coupling Direct Voltage regulation at established rating (+/- %) 1 Recovery time (Delta U = 20% 200 transcient) (ms) Indication of protection IP 23 Technology Brushless OTHER DATA Continuous Nominal Rating 40 C (kva) 27 Standby Rating 27 C (kva) 30 Efficiencies 100% of load (%) 83,30 Air flow (m3/s) 0,20 Short circuit ratio (Kcc) 0,55 Direct axis synchro reactance unsaturated (Xd) (%) 211,70 Quadra axis synchro reactance unsaturated (Xq) (%) 68,90 Open circuit time constant (T'do) (ms) 1280 Direct axis transcient reactance saturated (X'd) (%) 16,80 Short circuit transcient time constant (T'd) (ms) 58 Direct axis subtranscient reactance saturated (X''d) (%) 12,60 Subtranscient time constant (T"d) (ms) 14 Quadra axis subtranscient reactance saturated (X"q) (%) 36,10 Subtranscient time constant (T"q) (ms) 13 Zero sequence reactance unsaturated (Xo) (%) 1,90 Negative sequence reactance saturated (X2) (%) 27 Armature time constant (Ta) (ms) 30 No load excitation current (io) (A) 0,83 Full load excitation current (ic) (A) 3,30 Full load excitation voltage (uc) (V) 35,20 Engine start (Delta U = 20% perm. or 30% trans.) (kva) 87,70 Transcient dip (4/4 load) - PF : 0,8 AR (%) 12,60 No load losses (W) 935 Heat rejection (W) 5413 Unbalanced load acceptance ratio (%) 100 DIMENSIONS Dimensions soundproofed version M137 Width (mm) 938 Height (mm) 1285 Dry weight (kg) 809 Tank capacity (L) 100 Acoustic pressure level @1m in db(a) 76 Sound power level guaranteed (Lwa) 90 Dimensions DW soundproofed version M137-DW Width (mm) 932 Height (mm) 1486 Dry weight (kg) 1018 Tank capacity (L) 240 Acoustic pressure level @1m in db(a) 75 Dimensions DW compact version Length (mm) 2074 Width (mm) 932 Height (mm) 1401 Dry weight (kg) 830 Tank capacity (L) 240 Acoustic pressure level @1m in db(a) Sound power level guaranteed (Lwa) Acoustic pressure level @7m in db(a) Dimensions DW 48h soundproofed version M137-DW48 Width (mm) 932 Height (mm) 1539 %PdnetE_5% 1025 Tank capacity (L) 470 Acoustic pressure level @1m in db(a) 75

Sound power level guaranteed (Lwa) 90 Sound power level guaranteed (Lwa) 90

CONTROL PANEL APM303, comprehensive and simple APM403, basic generating set and power plant control The APM303 is a versatile unit which can be operated in manual or automatic mode. It offers the following features: Measurements: phase-to-neutral and phase-to-phase voltages, fuel level (In option : active power currents, effective power, power factors, Kw/h energy meter, oil pressure and coolant temperature levels) Supervision: Modbus RTU communication on RS485 Reports: (In option : 2 configurable reports) Safety features: Overspeed, oil pressure,coolant temperatures, minimum and maximum voltage, minimum and maximum frequency (Maximum active power P<66kVA) Traceability: Stack of 12 stored events For further information, please refer to the data sheet for the APM303. The APM403 is a versatile control unit which allows operation in manual or automatic mode Measurements : voltage and current kw/kwh/kva power meters Standard specifications: Voltmeter, Frequency meter. Optional : Battery ammeter. J1939 CAN ECU engine control Alarms and faults: Oil pressure, Coolant temperature, Overspeed, Start-up failure, alternator min/max, Emergency stop button. Engine parameters: Fuel level, hour counter, battery voltage. Optional (standard at 24V): Oil pressure, water temperature. Event log/ Management of the last 300 genset events. Mains and genset protection Clock management USB connections, USB Host and PC, Communications : RS485 INTERFACE ModBUS protocol /SNMP Optional : Ethernet, GPRS, remote control, 3G, 4G, Websupervisor, SMS, E-mails