INSTALLATION INSTRUCTION

Similar documents
INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

INSTALLATION INSTRUCTION Bollard Light 12V

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

MOONRING 1.5 MOONRING 3

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

MAXLITE RKT LED Retrofit Kit

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

Captivate Illuminated Mirror Light

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

INSTALLATION INSTRUCTION Accent - Color Changing

Spun Bay Installation Standard Version (non dimmable), Hook Mount

I. Pendant Mount Installation

INSTALLATION INSTRUCTIONS

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

NIOB-2 2" BWF IOLITE TRIMS

Specification Grade Contemporary Wall Mount/Technical Installation Data

Installation Instructions MX LED Downlight Remodel

LAL SERIES LED LUMINAIRE

D3 INSTALLATION GUIDE

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

Record Plus. Molded Case Circuit Breaker Accessories. Plug In Base. DEH40915 Installation Instructions

Installation Instructions CRAFT M/L

Power Break II Circuit Breaker Accessories Motor Operator Mechanism

Round or Square Type Non-IC Adjustable Housing with Toroidal Transformer for Flangeless Trims E3_L_-HANM_ 1.7

RSA-MRZ Installation Instructions

RSA-MRZ Installation Instructions

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

Installation Instructions

GETTING STARTED WITH IN-WALL DIMMER SWITCH

Installation Instructions MX LED Enhanced Color Adjustable

Wet Rated Batten LED Luminaire

INSTALLATION INSTRUCTIONS

SPECFIT 8" Retrofit Downlight AD8 DIM010 UNV ADR8. Project: Part#: Type: Ex: AD8-LES-9040-DIM010-UNV-MD-ADR8-CC

SPECFIT 6" Retrofit Downlight AD6 DIM010 UNV ADR6. Project: Part#: Type: Ex: AD6-LES-9040-DIM010-UNV-MD-ADR6-CC

MODELS. 2 & 4 Low Profile Linears

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Round or Square Chicago Plenum Hi-lume Wall Wash Housing with LED Lamp for Flanged Trims E3_F_-L_WC-HL 1.0

Output (nominal lumens) 700 lm, 1000 lm, 1300 lm, 2000 lm, 3000 lm, 4000 lm, 5000 lm. Color and color temperature

LAMPS 8L - 1 LAMPS CONTENTS

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

Ardito LED - A2RSF SPECIFICATION SHEET. 2-1/2" Series. Ultra-Thin Profile Round Regressed Shower Trim SPECIFICATIONS

ASSEMBLY AND INSTALLATION INSTRUCTIONS

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

2-524-TLW Wood Trimless Fixed Camber BRO

LumeLEX 2084 SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Installation Instructions BLTR and 2BLTR Relight Assembly

Standards: UL & CUL Listed.

PROJECT INFORMATION PROJECT

Installation Guide DO NOT CUT WIRES

6" (1526"mm) High quality injection molded aluminum heat sink ensuring maximum heat dissipation for optimal performance. 1/16" (1 mm) 4-1/8" (105 mm)

Lights TURN SIGNAL/SIDE MARKER LIGHT/ PARKING LIGHT HIGH BEAM HEADLIGHT LOW BEAM HEADLIGHT CONTINUED FOG LIGHT. Maintenance 257

Project name. Qty. Output (nominal lumens) Colour and colour temperature. Optics (nominal distribution) Narrow spot 10, Narrow 20, Medium 40

Ardito LED - A4SAR SPECIFICATION SHEET. 4" Series. Ultra-Thin Profile Square Adjustable Regressed Trim SPECIFICATIONS

How to Replace a Switch

RECHARGEABLE SPOTLIGHT

6" (152 mm) ø 3-1/2" (89 mm)

Installation Instructions

PRIME PRIME 4 LED ARCHITECTURAL ROUND FLANGED DOWNLIGHT

BLACK BODY DIMMING 800/1300/1500 LUMEN 6 LED NEW CONSTRUCTION/REMODEL

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

WARNING / AVERTISSEMENT

performance & comfort

Dual Roller Fascia Coupled FlexShades Assembly and Installation Instructions

INSTALLATION INSTRUCTIONS

6-1/4. Adjusts from 1/2 min. to 5/8 max. Pan size: 8 1/2 x 12 9/16 SERIES TRIM TYPE ADJUSTMENT LUMENS [1] CRI CCT DISTRIBUTION.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Installation Instructions Shaper 1800 aircraft cable installation

Lights TURN SIGNAL/PARKING LIGHT HIGH BEAM HEADLIGHT LOW BEAM HEADLIGHT. Maintenance

UR4B 4" Series Square Adjustable Trim

5-1/4" (134 mm) ø 4" (102 mm)

Lumination TM LED Luminaires LAL Series - Continuous Run Option

UR4L 4" Series Square Adjustable Regressed Trim with Square Opening

UR4J 4" Series Square Downlight Regressed Trim with Square Opening

INSTRUCTION BOOK FOR. Dual Masking Electrol

Installation Instructions

RECHARGEABLE SPOTLIGHT

Section 7 - Troubleshooting Guide

LED Recessed Troffer Retrofit Kit

Installation Instructions

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions 4 Gravity Enhanced Color Adjustable

2005 and 09 Mustang install instructions Sequential / Chase Unit Partial Plug-N-Play Kit Meter4it Eng. Updated: 3/28/09

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Specification Sheet Soft Nano Tilt

Roof Top Unit. Description Model Use With Return Air Grill XXX OR XXX

UR4E 4" Series Round Downlight Regressed Trim

LED VaporProof Fixture

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Transcription:

Volta 4.5 - Downlight Round SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations. Go to the main fuse box, or circuit breaker. Place the main power switch in the OFF position and unscrew the fuse(s) or switch OFF the circuit breaker switch(es) that control the power to the fixture or room that you are working on. Place the wall switch in the OFF position. AVERTISSEMENT IMPORTANT : Coupez l électricité avant TOUTE manipulation. Lisez toutes les instructions avant d installer. Système est destiné à être installé par un électricien qualifié en conformité avec le code national de l électricité et les règlements locaux. Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l interrupteur principal en position d arrêt («OFF»). Placez l interrupteur mural en position d arrêt («OFF»). CAUTION All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts, or use any parts that are worn out or broken. Failure to follow could invalidate the ETL/cETL listing of this fixture. TRIM MODEL The trim R4RD1T and R4RD2T can be used with remodel and new construction round housings. The less R4RD1L and R4RD2L to be used with new construction round housing. Refer to specification sheets for compatible housing and trim details. Follow appropriate housing instructions to begin installation. TRIM INSTALLATION (R4RD1T, R4RD2T) 1. Remove trim from trim assembly (See FIG.1) 2. Raise trim assembly to ceiling cutout and connect power connector and safety cable (See FIG.2) 3. Install connector cap onto top of trim assembly, careful not to pinch power wiring. Make sure the cap wire cable aligns with the notch on the top of heat-sink. (See FIG.3). FIG. 1 FIG. 2 FIG. 3 assembly Power Connector Safety Wire Notch Cap 1

Volta 4.5 - Downlight Round 4. Fold trim assembly mounting springs inward and insert trim assembly into ceiling cutout. Be sure once installed, trim assembly is flush and secure (See FIG.4). 5. Raise trim into trim assembly. Be sure trim springs go into slots in assembly. Raise trim flush with ceiling surface (See FIG.5 &6). FIG. 4 FIG. 5 FIG. 6 Tab less INSTALLATION (R4RD1L, R4RD2L) 1. Remove trim from trim assembly (See FIG.7). FIG. 7 2. Raise trim assembly to ceiling cutout and connect power connector and safety cable (See FIG.8). 3. Install connector cap onto top of trim assembly, careful not to pinch power wiring. Also make sure the cap wire cable align with the notch on the top of heat-sink. (See FIG.9). 4. After power and safety chain connections, insert trim assembly into spackle frame (See FIG.10). assembly FIG. 8 FIG. 9 FIG. 10 Wire Power Connector Safety Notch 2

Volta 4.5 - Downlight Round 5. Adjust trim assembly to the desired location and lock by using screw driver to secure horizontal adjustable lock (See FIG.11). 6. Raise the less up to trim assembly until the trim ring is flush to the ceiling cutout. Be sure trim springs mount into slots in trim assembly (See FIG. 12, 13). FIG. 11 FIG. 12 FIG. 13 Horizontal Adjustable Lock ACCESSORY INSTALLATION s feature a high and low position. Accessory and accessory holder can be used with trim in high position. FIG. 14 1. Power off fixture and let fixture cool down. 2. Remove trim from trim assembly (See FIG.14). 3. Raise the heat sink to high position (See FIG.15) 4. Prepare accessory holder with appropriate accessory (See FIG.16). 5. Raise the accessory assembly up into the trim opening, engage the accessory holder at white tabs of optical cartridge and turn clockwise to lock (See FIG.17). 6. Raise trim up to trim assembly until trim is flash with ceiling surface. Be sure trim springs mount in appropriate slots in assembly (See FIG.5 & 6). FIG. 15 FIG. 16 Make sure the spring bulge FIG. 17 Bulge installation into the slot High Position Push the heatsink location to high position Accessories Accessory Holder Accessory assembly hold up to (2) accessories Module Honeycomb Louver Accessory Holder Low Position Cross Louver Accessory 3

Volta 4.5 - Downlight Round REFLECTOR AND REPLACEMENT 1. Power off fixture and let fixture cool down. FIG. 18 2. Exchange reflector Note: Not for spot distribution which features dedicated module a. Remove the trim from the trim assembly (See FIG.14). b. Inset hand into fixture opening to grip optical cartridge, rotate to unlock and take out (See FIG.18). c. Insert replacement reflector into optical cartridge, put the whole assembly back inside fixture and lock it to the heat sink. d. Reinstall the trim assembly and trim inside fixture to complete. 3. Replace the module (For Narrow, Flood & Wide Beams) a. Remove trim from the trim assembly first, then the trim assembly from the ceiling or fixture aperture (See FIG.19). b. To remove the less assembly, use the Philips head screw driver to unlock horizontal lock, then use the flat head screw driver to release the spring tab on aperture ring (See FIG.20). c. Remove cap and disconnect power connector and safety cable (See FIG.21). d. Unlock and remove the optical cartridge and reflector (See FIG.18). e. Unscrew the holder and remove the connector from the module (See FIG.22, 23). f. Remove and discard the module from the heat sink. g. Coat the heat paste (by others or call the factory) on the back of the new module and place it on the heat sink by aligning two holes on with two screw holes on the heat sink. h. Connect the module with connector and fasten the holder on top of the model by tightening two screws. i. Reinstall the reflector and optical cartridge (See FIG.18). j. Connect power connector and safety cable, then reinstall the trim assembly and trim inside fixture to complete. Rotate counterclockwise to unlock FIG. 19 FIG. 20 Rotate clockwise to lock Horizontal Lock Tab FIG. 21 FIG. 22 FIG. 23 Connector cap Safety Power Connector Holder Reflector Connector 4

Volta 4.5 - Downlight Round 4. Replace the module (For Spot Beam) a. Remove trim from the trim assembly first, then the trim assembly from the ceiling or fixture aperture (See FIG.19). b. To remove the less assembly, use the Philips head screw driver to unlock horizontal lock, then use the flat head screw driver to release the spring tab on aperture ring (See FIG.20). c. Remove cap and disconnect wire connector and safety cable (See FIG.21). d. Unlock and remove the optical cartridge and lens (See FIG.18). e. Unscrew and remove the holder (See FIG.24). f. Remove and discard the module from the heat sink. g. Coat the heat paste (by others or call the factory) on the back of the new module, then mount the onto the holder. Make sure positive matching the holder positive. (See FIG.25) h. Place back the holder on the heat sink by tightening two screws. i. Lock the optical cartridge with lens on the heat sink. (See FIG.18) j. Connect power connector and safety cable, then reinstall the trim assembly and trim inside fixture to complete. FIG. 24 Holder FIG. 25 Holder 5