Installation Instructions for Slide Mount Magnetic Locks

Similar documents
Installation Instructions for ROFU Key Hole Mount Magnetic Locks

STANDARD / DOUBLE STANDARD MAGNETIC LOCK

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

MODEL 1200S MAGNETIC LOCK

MODEL 1200S MAGNETIC LOCK

MODEL 600S 600 POUND SINGLE MAGNETIC LOCK SPECIFICATIONS

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

With LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA lb.

Pre-Installation Instructions

Installation Instructions

V2M1200/1290 Series Maglock Installation Instructions

1-3/4" MOUNTING INSTRUCTIONS: 1150 SERIES SURFACE MOUNTED 1500 LB. ELECTROMAGNETIC LOCK

MAGNETIC LOCKS SERIES OPTIONS (ADD TO LOCK): xl. ADD 1 LED (BICOLOR RED / GREEN) xd. ADD SPDT DOOR POSITION SWITCH (SINGLE) x2d

INSTALLATION 8310/8320

Instructions For PG-1200RC Magnetic Locking Devices

Excel Series Value Engineered Access Hardware

M670/M680BD MAGNALOCK SERIES Installation Instructions

MODEL 3002xTJ32 ELECTROMAGNETIC LOCK INSTALLATION INSTRUCTIONS

MODEL 1200LB 1200 POUND MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR

Electromagnetic Locking Solutions

cel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches

Package Contents. Mounting Hardware

LOCKNETICS MagForce+ Series. Locknetics MagForce Traffic Control Magnet MEA

280+ SHEARLOCK INSTALLATION AND WIRING MODELS: 280+ and 280+TRD TRD

E-941SA-300RQ. Manual. 300-lb Single-Door Electromagnetic Lock with Reversible Magnet

INSTALLATION EML375. Pre-Installation Instructions. Electromagnetic Locks

MagForce+ The Positive Force in Electromagnetic Locks

INSTALLATION DESCRIPTION

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty.

R F O U PRICE LIST 2016

Electromagnetic locks - Single Doors

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

5600 Series Power Operator Installation and Instruction Manual

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

Accessories 286 SDC SECURITY DOOR CONTROLS

EMLock 1500 Series. MEA Listed

Standard Auxiliary L-Brackets & LZ-Brackets

ARCHITECTURAL DOOR HARDWARE DOOR STOPS & HOLDERS THRESHOLDS & GASKETING CATALOG

ELECTRONIC ACCESS CONTROL PRODUCT CATALOG

!!!! ! Lock housing dimensions: 230mm L x 44mm W x 44mm D! Receptacle housing dimensions: 120m L x 44mm W x 44mm D. ! Surface mount housing for LK120

ROFU International Corporation

Trine-Electric Strikes & Accessories

Electromagnetic Locks Indoor GEM Series

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

Installation and Service Manual

Security Door Controls

Fitting Instructions. Armlock 1354 Mini Electro-Shearmagnet (Surface) Contents

4000 Series mounted closers

Electromagnetic Locks Weatherproof Series

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

lkm7001 key override module Installation Instructions Converting The LKM7000 to The LKM7003

HANDLING MECHANICAL INSTALLATION

12V / 24V Magnetic Gate Lock 1200lbs with Brackets

INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S

Electromagnetic Lock Reference Chart

99-03 V6 "Shaker" System Instructions. *03 Model requires new hood Contents w/ Kit. Tool List For Appliqué:

WORX RACING YAMAHA STEERING STEM PART # - WR06030

SEM SERIES FEATURES SEM 7820 MAGNET SEM FEATURES

JACKSON CORPORATION Series

Pre-Installation Instructions

CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

2965 Magnetic Shear Lock Installation Instructions

IK - Installation Kit. The complete IK and IK2 kits offer substantial savings over purchasing the same items separately

S (8.0) (5.15).551 (14.0) .275 (7.0) S100

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Replacement Door Bottom for Pease style doors MD /16 Beige 6 $13.20

LCN 9740 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Legacy Installation Manual

Electric Strikes for Adams Rite Deadlatches and Cylindrical Locks

Electric Dropbolts. Secure and Intelligent Bolts. Fail-Safe Series Functions. DPS & BSS Outputs. Fail-Secure Series Functions

ELECTROMAGNETIC LOCKS

ROTON CONTINUOUS GEARED HINGES TABLE OF CONTENTS. L Length Specifications B Bearing at Top...4 Bearing on Top...4 Bearing Replacement Kit...

9540 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

Electromechanical Door Solutions

Product Drive Cameron Park, CA PH: PRO LAUNCH INSTALLATION INSTRUCTIONS

Electromagnetic Locks DORMA EML

1. Gently pry off the interior door trim. Clean out and remove any insulation from the original prehung system.

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

Locking Devices. Electromagnetic Locks. Security Door Controls 8 SECURITY DOOR CONTROLS

LCN SEM SERIES FEATURES. SEM 7820 MAGNET Die Cast, Floor mounted. SEM 7870 MAGNET Die Cast, Dual Sided Floor mounted. SEM FEATURES

VM300 Series. Electromagnetic Lock BRACKETS SPECS VM300

2300 OPERATING/APPLICATION/INSTALLATION INSTRUCTIONS

LCN 9540 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

ELECTROMAGNETIC LOCKS

Legacy Installation Manual

DynaLock 705 Emmett Street Bristol, CT Phone:(860) Fax:(860)

HMD v Power Feed with Coolant HMD v Type I plug, Power Feed with Coolant

RECESSED MAGNALOCK MODEL M34R SERIES INSTALLATION AND OPERATING INSTRUCTIONS

LIST PRICING Component & Part Options

9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

SIGNETMARINE. Livewell Bait Pump Alarm. No Dead Bait.

EURO VISTA FOLD. Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL FOLDING SLIDING STACKING PIVOT

ArchiTech by Networx

User Guide. Asset Guard PW INSTALLATION GUIDE. Table of Contents GETTING STARTED... 2 HARDWARE MOUNTING... 3 DEVICE CONNECTIONS...

Transcription:

ROFU For Outswing Doors Installation Instructions for Slide Mount Magnetic Locks 8606, 8608 and 8612 Series *See page 2 for model specifications R Find the paper installation template included with the magnet (you will need this). Fold it on the dotted line. The rubber washer helps the armature plate to pivot s it should NOT be tightened all the way to door. Place the folded template in the proper position on the door/jamb and mark the holes you will cut for your magnet and armature plate. (Using tape will help) Adjustable Attach the mounting plate with the provided Phillips screws. Then the position of the mounting plate should still be adjustable. (Sample drawing as 8612 series mounting plate) Drill the holes according to the marks you made. Wiring 4 (Check Twice! Drill Once!).. Install the armature plate as shown in the drawing to the left. Attach the mounting plate to the jamb with included mounting Phillips screws as shown. (Sample drawing as 8612 series magnet & mounting plate) The actual dimensions of the holes are illustrated below. Hollow Metal Door Solid Door Use the Allen wrench and thru-bolts to tighten the magnet to the mounting plate. 1 7/16 Allen Wrench 1/2 5/16 1/2 5/16 Drill a 5/16 (8mm) hole through the door for the armature side. For the sexnut side (secure side), enlarge the hole to 1/2 (12.7mm) for the width of the sexnut. On wood doors the depth of the sexnut is 1 7/16 (36mm). Outswing Door Connect the power and test the holding force. Add washers if there is still a gap between the magnet and armature plate. Wires (Sample drawings above as 8612 series magnet & mounting plate) (1) Pass the wiring through the mounting plate and into the wiring hole at the top of the magnet and into the PCB area. (2) Slide the magnet onto the mounting plate. (3) Once into proper position, tighten the thru-bolts from the bottom of the magnet into the mounting plate using the included Allen wrench. Allen Wrench 1

ROFU Z-bracket for Inswing Doors 1 2 3 4 Find the correct mounting position on the door jamb for the L-bracket. Ensure that the door still closes with it in position. Use the thru-bolt to install the magnet onto the L-bracket. Assemble the Z-bracket, but not too tight as it needs to remain adjustable for now. Insert the roll pins into the armature plate. 5 6 7 Finish Outdoor Outdoor Attach the armature plate and washers to the Z-bracket assembly. Specifications Close the door and connect the power. Voltage: 12/24 VDC Selectable Current Draw: 500 ma /12VDC, 250 ma / 24VDC Holding Force: 600 lbs, 600lbs, 800lbs, 800lbs, 1200 lbs, 1200 lbs Dimensions: 8606-B/BD: (600 lbs) Magnet: 9 13/16" 13/16" " (250 5.5 5mm) : 7 1/4" 1/2" /2" (185 x 38 2mm) 8606-2-BD: (600 lbs ) Magnet: 19 11/16" 13/16" " (500 5.5 5mm) s (each side): 7 1/4" 1/2" /2" (185 x 38 2mm) 8608-LC/B/BD: (800 lbs) Magnet: 10 7/16" 1/16" 1/8" (265 2 9mm) : 7 1/4" 3/4" x 9/16" (185 5 4mm) 8608-2-B/BD: (800 lbs ) Magnet: 20 7/8" 1/16" 1/8" (530 2 9mm) s (each side): 7 1/4" 3/4" x 9/16" (185 5 4mm) 8612-LC/B/BD (1200 lbs) Magnet: 10 1/2" 13/16 " 9/16" (267 x 71 0mm) : 7 1/4" 3/8" /8" (185 x 616mm) 8612-2-B/BD: (1200 lbs ) Magnet: 21" 13/16" 9/16" (533 x 71 0mm) s (each side): 7 1/4" 3/8" /8" (185 x 616mm) After the magnet engages the armature plate, you can now adjust the Z-bracket, and attach to the door. Ensure all screws of Z-bracket are tighten to door. We encourage the use of thread locker (LocTite). Model Changes to ROFU ic Locking Devices 86 XX - 2 - (LC/BD/B) - (US28/40)(12/24) Holding Force: 06 = 600 lbs (Mini) 08 = 800 lbs (Midi) 12 = 1200 lbs (Standard) Functions: LC = Low cost (NO MONITORING) BD = Bond sensor, LED & Door status B = Bond sensor & LED only 2 = Double Magnet OR NOTHING THERE 6 = Slide mounting plate magnetic lock series MAGLOCK SERIES 12/24: 12/24 VDC Selectable Finish: US28 Satin Aluminum or US40 Duronatic / Dark Anodized Bronze (Limited Availability for US40) 8600 Series Diagrams of Magnets & Mounting s 8606-B, 8606-BD 8608-LC, 8608-B, 8608-BD 8612-LC, 8612-B, 8612-BD (600 lbs.) (800 lbs.) (1200 lbs.) 8606-2-BD 8608-2-B, 8608-2-BD 8612-2-B, 8612-2-BD (600 lbs. ) (800 lbs. ) (1200 lbs. ) 2

Wiring Diagram for 8606 and 8608 Series Single Magnet Models Supply PB contact output: Open / Not bonding status. contact output: Locked / Bonded status. Keypad/Reader Orange: White: Brown: Indicates the door is in and open or closed status. Reed switch rated 0.2A/12VDC supply Input For 8608-LC Wiring Wiring Diagram for 8612 Series Single Magnet Models supply PB Keypad/Reader contact output: Open / Not bonding status. contact output: Locked / Bonded status. Indicates the door is in and open or closed status. Reed switch rated 0.2A/12VDC Orange: White: Brown: supply For 8612-LC Wiring Input Voltage Selection Jumpers - ROFU recommends a good maintenance schedule! - Please ensure all armature bolts and mounting bolts are checked quarterly. - ROFU recommends using Loctite (Thread locker) on ALL bolts during installation. - Current Draw: 500 ma /12VDC, 250 ma / 24VDC per block 3

Wiring Diagram for 8606-2-BD and 8608-2-BD Double Magnet Models Supply PB contact output: Open / Not bonding status. contact output: Locked / Bonded status. Keypad/Reader Orange: White: Brown: Indicates the door is in and open or closed status. Reed switch rated 0.2A/12VDC Orange: White: Brown: Wiring Diagram for 8612-2-B/BD Double Magnet Models Supply PB Keypad/Reader contact output: Open / Not bonding status. contact output: Locked / Bonded status. Orange: White: Brown: Indicates the door is in and open or closed status. Reed switch rated 0.2A/12VDC Orange: White: Brown: 4

Installation Diagram & Screw Pack Components (Sample drawings of 8606-B & 8612-2-B magnet & assemblies) Mounting Mounting Cover Screw Screw Mounting Screw Mounting Screw Cover Components 8606-B 8608-B 8612-B 8608-LC 8612-LC 8608-2-B 8612-2-B Thru-s (5/32"5/32") (1/4" 21/32") (1/4" 21/32") Phillips Flat Head Screws (5/32" ") (11/32" 9/32"/32") (11/32" 9/32"/32") 0 0 Allen Flat Head Screw (5/16" 3/8") (5/16" ") (5/16" 3/8") (5/16" ") (5/16" 3/8") Hexagon Key (Allen Wrench) (1/8") (1/2" 9/16") (1/2" 9/16") 5

Installation Diagram & Screw Pack Components (Sample drawings of 8606-BD & 8606-2-BD magnet & assemblies) Mounting Mounting Cover Screw Screw Screw Mounting Screw Cover Mounting Holder Holder Holder Components 8606-BD 8608-BD 8612-BD 8606-2-BD 8608-2-BD 8612-2-BD Thru-s Phillips Flat Head Screws (5/32"5/32") (1/4" 21/32") (5/32" 5/32") (1/4" 21/32") (5/32" ") x 6 (11/32" 9/32"/32") (9/16" 3/16" /32") 1 1 0 2 2 (5/32" ") 2 (11/32" 9/32" /32") (9/16" 3/16" /32") Allen Flat Head Screw (5/16" 3/8") (5/16" ") (5/16" 3/8") (5/16" 3/8") (5/16" ") (5/16" 3/8") Hexagon Key (Allen Wrench) (1/8") (1/8") (1/2 9/16 ) (1/2 9/16 ) 6