StormPro BCV400 Sewage Ejector Pump

Similar documents
StormPro BA Series Sump Pump

Matala. VersiFlow Series. Instruction and Maintenance Manual

GeyserMax-Flow Series

ESE Series Cast Iron Sewage Pumps

Ion Technologies WC33 Submersible Sump Pump

Owner s Manual Drill and Light Weight Portable Utility Pumps

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

MetroPrime 22MPC Self-Priming Centrifugal Pump

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

StormPro 2100DC Heavy Duty 12V DC Pump

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS

Stormpro 2100-DC. OPERATION MANUAL Heavy Duty 12V DC Pump Dated: 04/24/08 Supersedes: 02/04/08 Document No.: Spro2011-DC-OM Page 1 of 7

Ion Technologies SEF100-SEF200 Heavy Duty Sewage Pumps

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Ion Technologies ES45 Effluent Pump

SUMPRO Battery Back-Up

SH30 High Head Effluent Pump

Ion StormPro 55ACi+ & 55ACi Deluxe Battery Backup System

30ACi+, 30ACi Deluxe, 35ACi+ and 35ACi Deluxe Battery Backup System

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

SUMPRO Battery Back-Up

Pump Installation and Service Manual HRS Hydromatic Retractable System

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

SPC-PANEL Simplex, Single Phase Pump Control Panel

PRE-PLUMBED SEWAGE SYSTEM

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

OWNER S MANUAL. INSTALLATION AND OPERATION INSTRUCTIONS FOR 12 VOLT BATTERY BACK-UP SYSTEM Models: 92900, 92910

EBARA Fluid Handling

INSTALLATION & SERVICE MANUAL

SUNC3000 / Item #40885

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

AUTOMATIC SUBMERSIBLE UTILITY PUMP

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Air Curtain. Installation, Operating and Maintenance Instructions

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

SUPER PUMP OUT SYSTEM

Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

HALLMARK INDUSTRIES INC

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

Pump Installation and Service Manual SK60 Submersible Sewage Ejector Pump

Users Guide for Ac-sync

READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP

SUBMERSIBLE PUMP HSE RANGE

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Instruction Manual For Baldor Buffers

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Power. On Your Terms.

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

SUBMERSIBLE PUMP HSE RANGE

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

10 Year Limited Warranty

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

GARDEN HOSE UTILITY PUMP

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

OWNER S MANUAL Spa & Jetted Bathtub Pump

Operating and Installation Instructions

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Kitchen Tech Series Air Curtain

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

INSTALLATION & OPERATION MANUAL

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

Read and follow all instructions. Safety can only be ensured if the walker is assembled and operated according to these instructions.

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

List Price Sheet. Wholesale Products. 3 Year Warranty

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Please contact your supplier (supplying dealer or contractor) if service is necessary or if you have any questions or need further assistance.

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Installation & Operators Manual

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Pump Installation and Service Manual SK75/100 Submersible Sewage Ejector Pumps

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

Transcription:

Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING: This sign warns the operator that the failure to follow an instruction may damage the pump and/or the system. Limitations This pump series is suitable to pump water and also can be used both for permanent and temporary installation. The pump can be placed in a sump or sewage pit and is capable of passing 2 inch solids. WARNING: The pump can be used for sea water but not inflammable, corrosive, explosive or dangerous liquids. Make sure that the pump never runs without liquids. Specifications Thank you for purchasing a StormPro sewage ejector pump. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction manual in a safe place for future reference. Check the nameplate for your pump s specification, refer to the table list. Be careful not to exceed the given specifications in the use of your pump. Head - feet 30 25 20 15 10 5 0 0 10 20 30 40 50 60 70 80 90 Capacity - US GPM Model HP Output Amp Discharge (inch) Head (feet) Rated Flow (GPM) Head Maximum Flow Dimensions L x W x H Weight (lbs) BCV400 1/2 8.5 2 10 70 0 GPM @ 25' 90 GPM @ 0' 9⅛ x 5½ x 16 31 Available in Ion switch, Model BCV400A, or manual, Model BCV400M, configurations.

Page 2 of 8 Page 3 of 8 Installation Drill a 1/8" inch hole into PVC Pipe 4" inches above the pumps discharge. Do not work on pump until power is unplugged. Do not cut off ground pin or use an adapter fitting. WARNING: Sump basin must be vented in accordance with local plumbing codes. StormPro sewage ejector pumps are not designed for and can not be installed in locations classified as hazardous. 7. The following may cause severe damage to pump and will void the warranty: feet for outdoors. The plug and connections should be protected from water splashes. Before using the pump, always inspect it visually (especially power cable and plug). Do not use the pump if it is damaged. If the pump is damaged, have it inspected by an authorized service center only. Construction & Parts List Do not use an extension cord. The pump power cord should be connected to a separately fused, grounded line with a minimum capacity of 15 amps. It can be connected to non-fuse breaker as the recommended amperes. Never touch the pump when it is connected to electrical power. 1. Before installing or servicing this pump, be certain pump power source is disconnected. 2. Installation and electrical wiring must adhere to state and local codes and must be completed before priming pump. Check appropriate community agencies, or contact local electrical and pump professionals. 3. Call an electrician when in doubt. Pump should be connected to a separate 15 amp circuit breaker or 15 amp fuse block. Note that, plugging into existing outlets may cause low voltage at motor, causing blown fuses, tripping of motor overload, or burned out motor. 4. A permanent ground connection from pump to the grounding bar at the service panel is mandatory, StormPro sewage ejector pumps come with a grounding conductor and a grounding-type attachment plug. Do not connect pump to a power supply until permanently grounded. For maximum safety, connect pump to a circuit equipped with a fault interrupter device when you position the pump s grounding wire. 5. Voltage of power supply must match the voltage of the pump. 6. Before installing pump, clear sump basin of any water, debris or sediment. a. Using an extension cord. b. Cutting off the ground pin or using an adapter fitting. c. Working on pump or switch while plugged in. d. Removing motor housing, unscrewing impeller, or otherwise removing impeller seal. e. Running the pump continuously. f. Pumping chemicals or corrosive liquids. g. Pumping gasoline or other flammable liquids. h. Piping, plastic PVC pipe could be installed in the outlet piping, but drain hose, galvanized steel or copper pipe may be used if desired. All piping must be clean and free of all foreign matter to prevent clogging. Use thread compound on all threaded joints unless specified otherwise. Be sure to seal the thread connection with tape when your using the pipe fitting to connect the flange. i. Pump will be inadequate if suspension liquids contain solid particles larger than 2". Electrical Wire Connection WARNING: Verify that the voltage and frequency of the pump shown on the nameplate correspond to those available on the mains. The installer must make sure that the electric system is grounded in accordance with the law in force. It is necessary to use cable with a length of 10 or 20 Make sure that electric connections are protected from inundation. Protect the plug and the power cable from heat, oil or sharp edges. WARNING: The power cable must be replaced by qualified personnel only. Grounding The plug of the power cable has a double grounding contact, so that grounding can be performed by simply inserting the plug. Recommended Battery Back-Up SUMPRO is the ultimate, fully-automatic auxiliary power source that Metropolitan Industries recommends using as a battery back-up for your BCV400 sewage ejector pump. SUMPRO features the following: 1. Easy installation, no modifications or piping changes 2. Operates your pump during a power outage keeping your basement dry 3. Provides ultimate protection against blackouts and/or brownouts. For more information please visit www.sumpro.com. # Name Description 1 Power Cord Set 16AWG 2 Top Cover NL66+30%GF 3 Capacitor 4 Upper Bearing 5 Motor Housing SUS304 6 Shaft SUS410 7 Motor Winding C60 8 Lower Bearing 9 Mechanical Seal CA/CE 10 Seal Plate FC200 11 Oil Seal Cover FC200 12 Oil Seal NBR 13 Impeller FC200 14 Spring Washer SUS304 15 Screw Nut SUS304 16 Pump Casing FC200 17 Bearing Sleeve SUS304 18 Nut SUS304

Page 4 of 8 Page 5 of 8 Troubleshooting Checklist Warranty Registration Card DANGER: Shut off power to pump. Problems Pump does not run and hums. Pump runs but does not deliver water. Pump runs and pumps out sump, but does not stop. Possible Causes 1. Line circuit breaker is off, or fuse is burned or loose. 2. Water level in sump has not reached turn-on level. 3. Pump cord is not making contact in receptacle. 4. Float is stuck. It should operate freely in basin. 5. If all of the above are OK, then the motor could be malfunctioning. 1. Check valve is installed backwards. Arrow on valve should point in direction of flow. 2. Discharge shut-off valve (if used) may be closed. 3. Impeller or volute openings are fully or partially clogged. Remove pump 4. Pump is air-locked. Start and stop several times by plugging and unplugging cord. Check for clogged vent hole in pump case. Drill a 1/8 inch hole into PVC Pipe. 5. Inlet hole in pump base is clogged. Remove pump and clean the opening. 6. Vertical pumping distance is too high. Reduce distance or change the discharge fittings of the pump. 1. Float is stuck in up position. Be sure float operates freely in basin. 2. Defective float switch, replace. 3. Defective vertical switch, replace. Please fill out and send back to: Metropolitan Ind. Warranty Department P.O. Box 7266 Romeoville, IL 60446. Or to register online, go to www.sumpro.com Name: Address: City Warranty Registration Card To register your purchase, please fill in the following information: State: Date: Zip: Pump runs but delivers only a small amount of water. 1. Pump is air-locked. Start and stop several times by plugging and unplugging cord. Check for clogged vent hole in pump case. Drill a 1/8 inch hole into PVC Pipe. 2. Vertical pumping distance is too high. Reduce distance or change the discharge fitting of the pump. 3. Inlet hole in pump base is clogged. Remove pump and clean the opening. 4. Impeller or volute openings are fully or partially clogged. Remove pump 5. Pump impeller is partially clogged with tar or paint, causing motor to run slow and overload. Remove pump Purchased From: Installed By: Phone: Fuse blows or circuit breaker trips when pump starts. 1. Pump impeller is partially clogged with tar or paint, causing motor to run slow and overload. Remove pump 2. Motor stator may be defective. 3. Fuse size or circuit breaker may be too small. (Must be 15 amps). 4. Impeller or volute opening are fully or partially clogged. Remove pump and clean Motor runs for a short time, then stops. 1. Inlet hole in pump base is clogged. Remove pump and clean the opening. 2. Pump impeller is partially clogged with tar or paint, causing motor to run slow and overload. Remove pump 3. Motor stator may be defective. 4. Impeller or volute openings are fully or partially clogged. Remove pump WARNING: Before servicing a pump, always shut off the main power breaker and then unplug the pump. Make sure you are not standing in water and are wearing insulated protective sole shoes, under flooded conditions, Contact your local electric company or a qualified licensed electrician for disconnecting electrical service prior to pump removal.

Page 6 of 8 Page 7 of 8 Notes Notes

Page 8 of 8 3 Year Residential Warranty 1. Coverage and Term. Metropolitan Industries, Inc. ( Metropolitan ) warrants to the original purchaser (the Buyer ) of each StormPro/Sumpro product (the product ), that any part thereof which proves to be defective in material or workmanship within three (3) years from date of manufacture, will be replaced at no charge with a new or remanufactured part, F.O.B. factory. Buyer shall be responsible for all freight charges and all costs of field labor or other charges incurred in the removal and/or reinstallation of any product, part or component thereof. 2. Exclusions. THE WARRANTY IS SUBJECT TO THE FOLLOWING CONDITIONS AND EXCLUSIONS: (a) The Warranty excludes products or workmanship which becomes defective as a result of: (i) earthquake, fire, storms, the elements or any other acts of God; (ii) normal wear and tear from use; (iii) accident, misuse, abuse or neglect; (iv) modifications made by Buyer or any third party, other than Metropolitan; and (v) Buyer s failure to properly install, maintain, service and/or operate the product under normal conditions and according to manufacturer s instructions. (b) Metropolitan shall not be responsible for, and the Warranty shall not cover, extended damage which occurs because of Buyer s failure to notify Metropolitan promptly in writing of apparent defects. (c) Any part or component designated as manufactured by anyone other than Metropolitan shall be covered only by the express warranty of the manufacturer thereof. (d) The Warranty shall lapse upon Buyer s failure to fully comply with the terms and conditions of its contract with Metropolitan, including Buyer s failure to pay the purchase price for the product or any portion thereof. Buyer s subsequent compliance with the terms and conditions of any such contract, will not cause the term of the Warranty to extend beyond the time period set forth above. (e) No actions taken by Metropolitan to correct a defect in a product shall extend the Warranty beyond the period set forth above. Metropolitan shall not be obligated to remedy any defect, where otherwise required pursuant to the Warranty unless and until Buyer notifies Metropolitan in writing of the defect and then only if such notification is made prior to the expiration of the period set forth above. 3. Process of Claims and Repairs. Metropolitan agrees that if the product or any part or component thereof shall fail to conform to the terms of this Warranty, Metropolitan shall replace such nonconforming product, part or component at the original point of delivery and furnish instruction for its disposition. Any transportation charges involved in such disposition and all costs of field labor or other charges incurred in the removal and/or reinstallation of any product, part or component thereof shall be the responsibility of Buyer. 4. Limitation on Liability. Notwithstanding any provision to the contrary, Metropolitan s entire liability under this Warranty shall not in the aggregate exceed, and Buyer s exclusive and sole remedies are, to the extent permitted by law, shall be to secure replacement of the defective product. UNDER NO CIRCUMSTANCES SHALL METROPOLITAN BE LIABLE UNDER THE WARRANTY FOR ANY INDIRECT, PUNITIVE, SPECIAL, EXEMPLARY, CONSEQUENTIAL OR INCIDENTAL DAMAGES (INCLUDING LOST PROFITS, REVENUE, USE OR ECONOMIC ADVANTAGE). 5. Express Waiver of Any Other Warranties. THE EXPRESS WARRANTY SET FORTH IN THIS WRITTEN WARRANTY IS THE ONLY WARRANTY MADE BY METROPOLITAN, OR ANY OTHER PARTY, IN CONNECTION WITH ANY PRODUCT PURCHASED FROM METROPOLITAN. NEITHER METROPOLITAN, NOR ANY OTHER PARTY, MAKES ANY OTHER EXPRESS OR IMPLIED WARRANTY WHICH IS NOT SET FORTH HEREIN, AND METROPOLITAN HEREBY DISCLAIMS AND BUYER HEREBY WAIVES ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. 6. Not Transferable. The Warranty may not be transferred and shall be void on the sale or other transfer of the product. 7. Products and Warranty Subject to Change. Metropolitan reserves the right to make revisions to its products and their specifications, and to revise this Warranty and related information without notice.