Z-Ion Installation and Retrofit Instructions

Similar documents
VENTURA 150 DELUXE INSTALLATION MANUAL

ISLAND EXPLORER SERIES REVERSE OSMOSIS DESALINATOR INSTALLATION & OPERATION MANUAL

LB Operating Instructions

NEWPORT SERIES INSTALLATION MANUAL

Making Your Own Watermaker

Fully Automatic Bilge Pump INSTRUCTION MANUAL

GT-R Alpha 10/12 Turbo Kit

Maxum II Modular Oven Automatic Purge Control Unit Product Update PU-002

Reverse Osmosis System

Lease Automatic Custody Transfer

Pre-plumbed Blowdown Assembly ½ Model

Pure Water. Anytime, Anywhere. Marine Desalination Systems

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d

Village Marine-PW Part Number: Pure Water Series PW 8,000-20,000 GPD. Installation, Operation & Maintenance

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Nautilus Gallon Per Day Modular Watermakers.

IMPORTANT SAFEGUARDS

Rev: Flow Max 115V AC Fluid Pump

Atomizer 36-DC User Guide

Cascade Comfort Bathing Systems with Aqua-Aire Parts Breakdown & Assemblies

PH1 AIR INTAKE EMERGENCY SHUT-OFF VALVE PULL CABLE ACTUATION.

SNIPER NITROUS SYSTEMS

DESCRIPTION AND OPERATION ICE DETECTION SYSTEM

POOL PILOT SOFT TOUCH OPERATING, TROUBLESHOOTING AND TECHNICAL CHEAT SHEET

FPS- 80. Manual. Reverso Pumps, Inc. Ph: (954)

OD10 10A Outdoor Solar Charge Controller

Automotive Application ET01 Software Revision A 12/06

Installation Kitchen Faucet Filtration System Instructions GXK285JBL

Dynamis LIX Batteries

Offshore Marine Labs Sea Quencher. The Sea Quencher Installation, Operation & Maintenance

Village Marine LWM The Little Wonder Modular Installation, Operation & Maintenance

The Traveler Series: Wanderer

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

Maxum II Modular Oven Automatic Purge Control Unit Product Update PU-002

DFS Dynamic Fuel Systems Inc.

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

DETAILED EQUIPMENT SPECIFICATION HIGH PURITY LABORATORY WATER SYSTEM

OnCommand Troubleshooting Guide Hayward Industries

Model &

CONCRETE CONTROLS CORPORATION 1311 N. CONGRESS DRIVE CHANDLER AZ FAX

Lifeline Medical Systems

Installation and Operation Instruction Manual INSMAN-201. Industrial Multi Media Single Tank

ETF-600 Sensor Operated Lavatory Faucet

R & D SPECIALTIES ROTROL I USER'S MANUAL

CHEMICAL MIXING SYSTEM OPERATING AND INSTALLATION INSTRUCTIONS

Illustrated Parts Guide DSD EDGE 120VAC. Page 1 of 32

ANZI Transfer Switch and Generator Wiring Installation Addendum

ULTRAVIOLET WATER DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL

ALLSTAR DILUTION CONTROL SYSTEM MODEL 639AG-4-1ABC

To ensure proper installation, digital pictures with contact information to before startup.

DETAILED EQUIPMENT SPECIFICATION MRO-4 SERIES REVERSE OSMOSIS SYSTEMS

POWER PINNER RAPID FIRE 7005 RF OPERATOR S MANUAL

STYLE 3491 Severe Duty Electric Mining Water Cannon INSTALLATION, AND OPERATING INSTRUCTIONS

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D

IRC Urinal Flush Control Valve

Application Engineering

O P E R A T I N G I N S T R U C T I O N S

P239-1 Supply Pumper Instructions

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

PACIFIC Recumbent Height-Adjustable Bath System Parts Breakdown and Assembly Manual

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

GENERAL INFORMATION 1 B MAINTENANCE

Battery Backup Sump Pump System Instruction Manual

PH3 AIR INTAKE EMERGENCY SHUT-OFF VALVE WITH POWERGUARD SMART OVERSPEED LIMITER. Generic PH3 Truck Shut-Off Valve Kit.

Cascade. Aqua-Aire. Standard & Swivel Lift Spas, Optional Reservoir. Parts Breakdown & Assemblies Right, Left, and End Tub Access Door Systems

Application Engineering

MODEL 901 OPERATING INSTRUCTIONS

Chemical Injection Pump. Quick Start Guide. Pump Models P-075-M1/ ALU P-075-M1/ SS CLASS 1 DIV 1

INSTALLATION INSTRUCTIONS

Click Here for Printable PDF File

Installation and Service Manual

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

2010+ Camaro Triple-Threat Wet Nitrous System

BASIC FOAM FIREFIGHTING OPERATIONS Red and Green Systems

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

THE NEW GENERATION WATERMAKERS

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

Proper Propane Pump Installation

Katadyn Desalination, LLC Spectra Watermakers PH FX Revised

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

AEROMOTIVE Part # HP Hot Rod EFI Kit INSTALLATION INSTRUCTIONS

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

The Traveler Series: Wanderer

The Sea Quencher Installation, Operation & Maintenance. Racor Offshore Marine Sea Quencher

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Infrared Control Valve Installation Guide

PURASAN. OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS (Models PST*02 and PST*03 [*specify 12,24,32] Manufactured after September, 2004)

LTM Series Modular Watermakers 500-1,800 GPD Installation, Operation & Maintenance. Contact: Green Marine & Industrial Equipment Co., Inc.

PowerFLO 5800/5900 Series

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS

Infrared Control Valve Installation Guide

Optima ETF-600/ETF-610

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

IOTA ONE OPERATING MANUAL AND SETUP INSTRUCTIONS IOTA ONE. Please Read this Instruction Manual COMPLETELY Before Operating the System IOTA ONE

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

MFM300 Plastic-Bodied Magmeter

INSTALLATION AND OPERATION MANUAL ARM-4073 AUTOMATIC REPRESSURE MODULES

N-084M and N-069M-DV Series Heat Exchanger Replacement

Model LA 4400 Time Delay OFF Controller

Transcription:

Z-Ion Installation and Retrofit Instructions Catalina 300 Mk II Katadyn Desalination, LLC Spectra Watermakers PH 415.526.2780 FX 415.526.2787 www.spectrawatermakers.com Revised 06.01.13

Thank you for choosing Spectra s Z-Ion system! This revolutionary adaptation of an ancient technology effectively and safely protects the membrane and filters on your Spectra watermaker. The Z-Ion system introduces a stream of metallic ions that kill the organisms in your watermaker and create an environment that prohibits them from growing and going anaerobic. The result is that your system will be kept ready to operate without any additional flushing, external power sources, pickling chemicals, or complex procedures. The whole operation is completely automatic, controlled by your MPC control and the Z-iON circuit! When properly installed and maintained it will protect your watermaker for up to 3 months*, without requiring additional flushes or external power being present. Please check the contents of this kit to ensure it is complete. Report any missing items to Customer Service immediately. Any shortages must be reported within 30 days of receiving the equipment. Included in this kit: Z-Ion Generator and Control Module Accumulator Tank Check Valve Carbon Block Filter Installation Kit * Storage times may vary depending on conditions.

Plumbing Installation Installation should always be carried out by a qualified technician to avoid problems and ensure warranty coverage. Turn off the domestic fresh water pump and bleed any remaining pressure in the pipes. Fresh Water Flush Module Remove the existing Fresh Water Flush Module from the system. Disconnect the inlet and discharge hoses, and label them as Inlet and Discharge accordingly. Inlet Z-Ion Flush Module Discharge Install the Z-Ion Flush Module in the same location as the Fresh Water Flush Module and reconnect the hoses in the corresponding location. Discharge To tee assembly

Plumbing Installation Accumulator Check Valve Assembly Close watermaker seacock. Cut inlet hose between the intake seacock and the strainer and install the accumulator- check valve assembly. Make sure that the check valve is oriented properly. Securely tighten the hose clamps as this is below the water line!

Plumbing Installation (Continued) Feed Pump Module Remove the Feed Pump Module cover, exposing the feed pump, and accumulator tank. Remove the black 3/8 fresh water flush tube from the back of the tee fitting at the inlet to the feed pump. Note: the fitting is located behind the pressure sensor with the yellow band.

Plumbing Installation (Continued) Install the blanking plug supplied in the install kit into the now open port on the gauge tee. Using the tubing supplied in the install kit, connect the 3/8 tube on the discharge of the fresh water flush solenoid and route it to the tee on the accumulator check valve assembly. Cut tubing and install end fitting. See Parker assembly instructions next page. Make sure that the tubing on the accumulator is secure as this will be below the waterline.

Parker tube assembly instructions

Wiring Installation Turn the main DC breaker off or remove the main power fuse to the watermaker. Locate the DC Bus Bar, as shown below, which is the main power feed for the watermaker. Incoming DC Bus Bar Connect the DC power leads from the Z-Ion Control Box to the Incoming DC Bus Bar. Z-Ion Fuse block Pay attention to polarity! Connect Red (fuse) to DC + Yellow (or black) to DC - Replace protective cover!

Testing the system Normally no adjustment is necessary as the unit has been set up at the factory for your watermaker, however it is advisable to make sure it is working properly. You will need Spectra test kit #EL-ZION-TESTKIT. Once the installation is complete and the unit is powered up, activate the FW flush by pushing the auto store button on the MPC controller once. The LED on the Z- ION controller should start flashing as the unit cycles. Close to the end of the flush cycle, take a sample of the brine discharge. If the discharge thru hull isn't accessible you will need to use the brine discharge service hose to gain access to the system. Once you have obtained a sample first check it with a salinity monitor to make sure the salinity is below 1000 PPM. Next, use the copper test kit to make sure that there is at least 1 PPM of copper in the flush water. This will also insure that there is adequate silver in the mix to kill the bacteria. If the flush water is above 1000 PPM or does not have adequate copper content then contact our technical support for instructions on how to adjust the system.

Z-ion Specifications The Z-ION controller has been specifically designed to batch process (produce) metallic ions for system disinfection. This process has been around for many years, however most systems produce ions on a continuous slow basis rather than a short intermittent process. It was found that the most stable way to produce ions in a batch process is to maintain a constant current to the electrodes and vary the voltage. By being able to boost the voltage the amount of electrode surface area can be smaller to produce the needed ions in a brief period of time. Features 10-48 VDC inlet voltage 10-38V output @1.5A Current controlled Polarity reverses every 10-15 seconds (adjustable) Timed auto shutoff (adjustable) Current output is field adjustable. Operation The unit can have power on at all times. Upon power up the LED will flash red/green and then goes green. Upon the trigger being actuated by going high the operation cycle begins. The unit will produce the set point current by adjusting the voltage applied on the electrodes. The LED will flash green/ amber as the polarity cycles. The cycle will continue until either the trigger voltage is removed or the adjustable timer, times out. If the voltage is out of range, below 10V or above 56V, the LED will flash red every two seconds and the unit will shut down.