COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

Similar documents
COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

Effective November 2016 Supersedes September 1998 (S )

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

Effective June 2016 New Issue

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

Effective March 2015 Supersedes S August 2012

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

Effective November 2016 Supersedes February 2012 (S )

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

High-voltage primary bushings installation instructions

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

Type NR oil switch installation and operation instructions

COOPER POWER SERIES. KA146W5 single pole-mounting hanger; KA146W2 tank lifting windlass assembly and installation instructions. Reclosers MN280039EN

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

COOPER POWER SERIES. KA716L7001 adjustable control valve kit for Types L, E, 4E, V4E, and V4L reclosers installation and adjustment instructions

Effective May 2017 Supersedes December 2004 (S )

Effective May 2017 Supersedes January 2003 (S )

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

Figure 1. Kearney Type HX cutout.

COOPER POWER SERIES. Instructions for oil-filled, single-phase overhead distribution transformers. Distribution Transformers MN201003EN

COOPER POWER SERIES. Manually-Operated M-Force Switch Installation and Operation Instructions. Switches and Disconnects MN008003EN

COOPER POWER SERIES. Metal-enclosed capacitor banks installation instructions. Power Capacitors MN230010EN

COOPER POWER SERIES. Metal-enclosed, pad-mounted capacitor banks installation instructions. Power Capacitors MN230009EN

Factory Authorized Mechanism Enhancement (FAME)

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage

S Voltage Regulators GENERAL. PRODUCT INFORMATION Introduction. Contents. Acceptance and Initial Inspection. Handling and Storage.

COOPER POWER SERIES. RVAC Fluid-insulated Vacuum Switchgear; Installation, Operation, and Maintenance Instructions. Switchgear MN285005EN

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage.

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

This Kit Is for Use with Types RE, RVE, WE, WVE, VWE, VWVE27, and VWVE38 Reclosers.

CCP2-FLR1-21_ flange-rod operating mechanism

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

COOPER POWER SERIES. Externally fused block banks installation instructions. Capacitors MN230004EN

COOPER POWER SERIES. Type MOST Fluid-Insulated Switchgear; Installation, Operation, and Maintenance Instructions

Instruction Booklet IB E. Contents

COOPER POWER SERIES. Types VWE, VWVE27, VWVE38X, WE, WVE27, and WVE38X; threephase electronically controlled; installation and operation instructions

Two-way cable interlock kit for Magnum fixed circuit breakers

COOPER POWER SERIES. VFI tester operating instructions. Underground Distribution Switchgear MN285001EN

Two-way cable interlock kit for Magnum drawout circuit breakers

Edison modular fuse, vault application products

3-way multi-family drawout cable interlock kit - type 32 - RF

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

Figure 1. ELSG Current-Limiting fuses. TABLE 1 Maximum Interrupting Current (rms symmetrical) INSTALLATION

Effective October 2016 Supersedes January 2014 (S )

COOPER POWER SERIES. Three-phase pad-mounted compartmental type transformer installation and maintenance instructions

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

K-Limiter high ampere Companion II fuse

KFE10010-E. Reclosers. Contents. Type KFVE and KFVME (27kV) Bus Bar Kit KRK710-1 Installation Instructions. Cooper Power Systems

25 kv class fused loadbreak elbow connector

Three-phase pad-mounted compartmental type installation and maintenance instructions

O & M Manual for the EATON Generator Ready Loadcenter

ELF -LR current-limiting fuse

Two-position sidewall (horizontal) and cover (vertical) mounted loadbreak switches

100 A externally operated one-, twoand three-phase tap-changer switch

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

CM52 Network Protector with Arc Flash Reduction Module

Design Tests for the 38.0 kv ELSP Current-limiting Fuse per ANSI/IEEE C

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

dfdf 34.5 kv and 69 kv, Type O Plus C II Condenser Bushings Technical Guide

600 A 15 and 25 kv class Cleer grounding elbow

ELB ELB

X-Limiter full-range current-limiting fuse

Installation Instructions For Motor Control Center (MCC) Units

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

Flush Mount AIN ALPHA Meters. General. Hardware Kit

600 A 28 kv class Cleer loadbreak connector system

Type DTU De-energized Tap Changer Application, Installation & Selection Guide. IL A Instruction Leaflet Page 1 September, 2003

Transcription:

Fusing Equipment MN132017EN Effective November 2016 Supersedes October 1998 (S240-82-1) ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions COOPER POWER SERIES

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. ii

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY... ii SAFETY FOR LIFE... iv SAFETY INFORMATION... iv Safety instructions...iv PRODUCT INFORMATION.... 1 Introduction...1 Re-fusing instructions...2 Replace ELSG fuse on handle assembly...3 Replace fuse assembly into wetwell.................................................................4 iii

ELSG Full-Range Current-Limiting Fuse! SAFETY FOR LIFE Safety for life! SAFETY FOR LIFE Eaton meets or exceeds all applicable industry standards relating to product safety in its Cooper Power series products. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high voltage lines and equipment, and support our Safety For Life mission. Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians who are familiar with this equipment should install, operate, and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as arc flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around highand low-voltage lines and equipment. G103.3 WARNING Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. G101.0 WARNING This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury and equipment damage. G102.1 WARNING Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. G122.2 iv

ELSG Full-Range Current-Limiting Fuse Eaton s Cooper Power series ELSG Full-Range Current- Limiting Fuse is designed to be operated in accordance with normal safe operating procedures. These instructions are not intended to supersede or replace existing safety and operating procedures. READ ALL INSTRUCTIONS BEFORE RE-FUSING AN ELSG FUSE..625" (15.9 mm) 3/8"-16 THD x.5 FULL THD. DEPTH 3/8"-16 THREAD B A a) Two-inch diameter single barrel fuse* 2.33" (59.2 mm) 1.00" (25.4 mm) 2.155" (54.74 mm) 3.00" (76.2 mm) 1.00" (25.4 mm) The fuse should be installed and serviced only by personnel familiar with good safety practice and the handling of high-voltage electrical equipment. 1.85" (46.99 mm) B A 3.25" (82.6 mm) b) Three-inch diameter single barrel fuse Product Information 1.53" (38.9 mm) A 2.33" (59.2 mm) 4.30" (109.2 mm) 4.37" (111 mm) 1.0" (25.4 mm) Remove and park all load side separable connectors and install insulated protective caps on tap bushing before installing or removing fuse. Fuse IS NOT a loadbreak device..722" (18.3 mm) 1.20" (30.48 mm) 3/8"-16 THD THRU B c) Two-inch diameter double barrel fuse* 2.155" (54.74 mm) TRIPLE FUSE ASSEMBLY Introduction The ELSG fuse is designed for use in padmount switchgear filled with mineral oil or approved equivalent. (Refer to Figure 2.) It may also be used to protect power transformers, feeders and other equipment that can benefit from its energy-limiting properties. The fuse provides consistent clearing of low currents as well as reliable high speed interruption of high magnitude short circuit currents. Its current-limiting capability limits both peak current magnitude and fault duration, thus limiting the let-through energy. The ELSG fuse is installed into the wetwell holder assembly of de-energized apparatus using a shotgun stick. 1.23" (31.24 mm).30" (7.62 mm) 3.30" (83.82 mm) B A 2.17" (55.12 mm) 2.17" (55.12 mm) 3.38" (85.85 mm) d) Two-inch diameter triple barrel fuse 4.68" (118.9 mm) 4.00" (101.6 mm) 1.00" (25.40 mm) DELRIN GUIDE ROD USED AS A MECHANICAL GUIDE FOR EASIER INSTALLATION Figure 1. Line illustration of ELSG Full Range Current- Limiting Fuses. Used as a mechanical guide for easier installation on fuse installed in the 25 and 35 kv wetwell holder. With ELSG Fuse Oil-Filled Padmount Switchgear Figure 2. Oil-filled switchgear with ELSG fuse installed in wetwell holder. 1

ELSG Full-Range Current-Limiting Fuse Re-fusing instructions 45 Remove handle assembly with fuse from wetwell holder Provide protection for rubber terminations from dripping oil. Install drip pan or cover rubber terminations. Operate pressure relief valve with shotgun stick (if applicable). To remove the bail assembly as shown in Figure 3, attach shotgun stick to eyebolt, loosen eyebolt and lower bail. (Refer to Figure 4.) Fuse Eye Top Cover of Handle Assembly Eyebolt 45 Bail Assembly (Loosened and Lowered) Bail Assembly Top Cover of Handle Assembly (Inside Tank) Figure 4. Lowered bail assembly. Tank Wall Shotgun Stick Figure 3. Side view of wetwell holder with bail assemblly installed. Place shotgun stick loosely on fuse holder eye. Figure 5. Rotate cap of wetwell holder to break the seal. Rotate cap clockwise 1/4 turn with shotgun stick to break seal. (Refer to Figure 5.) With shotgun stick still loosely attached, slowly lift fuse assembly from wetwell. (Refer to Figure 6.) Remove fuse slowly enough to allow excess oil to drain back into the well. Fuse should slide smoothly out of holder. If resistance is felt, turn fuse slightly and continue removing. Place fuse assembly in clean drip pan or drip cloth. Wipe off excess oil. (Refer to Figure 7.) 2

ELSG Full-Range Current-Limiting Fuse Fuseholder Eye Top Cover of Handle Assembly Guide Bracket Fiberglass Rod Guide Bracket Cap Guide Fingers Fiberglass Rod Upper Contact Handle Assembly Bail Assembly (Loosened and Lowered) ESLG Fuse Figure 6. Removal of handle assembly with fuse from wetwell. Replace ELSG fuse on handle assembly Shotgun Stick 45 ELSG Fuse Cap Guide Fingers 3.5 in. (89mm) 7.5 in. (191mm) 3.5 in. (89mm) Guide Bracket Upper Contact Single Barrel Use Double Barrel Use Figure 8. Fuse assembly consists of handle assembly plus ELSG fuse. (Plus guides, where applicable.) * 15.5 kv and 23 kv rated fuses use guide bracket (catalog no. 3439216B02). NNote: holder of fuse being replaced is deenergized. Other holders and, thus leads within the switchgear, may be energized. The guide(s) is to be installed on the fiberglass rod of the handle assembly as shown in Figure 8 to guide the fuse straight into the wetwell holder. One guide is included for the 15.5 kv and 23 kv 2-inch diameter double barrel fuse. Two guides are included for the 15.5 kv and 23 kv 2-inch diameter single barrel fuse. Figure 7. Place fuse assembly in clean drip pan. The spacing of the guides as shown in Figure 8 are critical to within ± 1/2 inch. Failure to use the guide(s) on the handle assembly as shown may allow the fuse to contact an energized lead and operate during installation or removal. The ELSG fuse is mounted to the handle assembly as shown in Figure 6. Remove the ELSG fuse from the operating handle assembly. Attach a new ELSG fuse to the operating handle. Tighten to 15 foot-pounds torque using 5/8 wrench flats on the side of holder eye on handle assembly. Position and securely tighten the guide(s) to the fiberglass rod of the handle assembly, as illustrated for the appropriately rated fuse. When two guides are used for the single barrel fuse, rotate the upper guide 60 out from the position of the lower guide as shown in Figure 9. NNote: For 2-inch diameter triple barrel ELSG fuse as shown in Figure 1, observe top adapter plate decal with insertion instructions. In addition, 15.5 kv and 23 kv rated fuses with 2-inch diameter single-barrel or double barrel use guide brackets (supplied with fuse) on the handle assembly. (See following steps for proper installation of handle assembly guide brackets.) 3

Upper Guide Lower Guide Replace fuse assembly into wetwell Attach shotgun stick loosely to fuse holder eye. Lift fuse assembly with shotgun stick and slowly insert assembly into wetwell holder. 60 Figure 9. Orientation of two guides on handle assembly. NNote: For 2-inch diameter triple barrel fuse as shown in Figure 1, insert assembly with arrow on top adapter plate facing up (12 o clock position). Center guide fingers of cap into wetwell until contact resistance is felt (Refer to Figure 10). Push fuse assembly into wetwell until cap seats. Replace bail assembly. Tighten eyebolt to seat cap gasket. Do not ram or force fuse closed. A firm push with a slight twist is all that is required. Shotgun Stick Figure 10. Guide fuse assembly into wetwell holder.! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2016 Eaton All Rights Reserved Printed in USA Publication No. MN132017EN Rev. 0 November 2016 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton s Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.