... TROX UK LABCONTROL Facility

Similar documents
Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

VARYCONTROL VAV Dual Duct Terminal Boxes

Fan - Powered Terminal Unit Series Flow

7 Services Control and monitoring

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

Parts and characteristics

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Laboratory Solutions. pricecriticalcontrols.com

VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications

3.5 Exposure Control Measures

RVP-R- VAV controller. In explosion-proof version

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Laboratory Exhaust Systems

Type Pneumatic actuators

Variable Air Volume (VAV) Pressure Independent Control

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Laboratory Room Controller

VAV controller. TROX Auranor Norge AS. Telephone Fax

CMR CONTROLS AIR MANAGEMENT SYSTEMS PRESSURE VELOCITY SENSORS AND CONTROLS PRECISION COMPONENTS FOR VENTILATION AND PROCESS AIR CONTROL

Sensor systems. Type Differential pressure transducer. For the differential pressure recording and control in combination with EASYLAB.

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

HML - Airflow Unit for Large Volumes. HML Airflow Unit for Large Volumes. with Centralized Airflow Heating

HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

Medium Pressure Centrifugal Fans

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Grilles Linear Grilles

ceiling swirl diffuser DQJ

Bench Top Extraction Arms

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

STR Circular VAV Terminal Units

Incorporating V2.0. Product spec >>> > Series NV - Non vision grilles

Ceiling Swirl Diffuser DQJ

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

Catalog Swirl diffuser DAL 358

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

Air Flow Measurement Technologies

PROHOOD AIR CAPTURE HOOD MODEL PH731

Design Standard - Fume Hoods & Fume Hood Exhausts

Fume cupboards and extraction devices

Homepage > Products > Airflow Control - VAV and CAV > Variable air volume flow control - VARYCONTROL > Control components > Type Easy.

Precision-I Laboratory System Universal Digital Monitor

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Laboratory Exhaust Systems

CIRCULAIRE FILTRATION FUME CUPBOARDS

Series. Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry

CONSTANTFLOW Volume Flow Controllers

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

---:...-- Environmental Health & Safety RADIATION PROCEDURES MANUAL. Procedure Cover Sheet. Procedure Number: EHS REV 2

DPC300 FUME CUPBOARD CONTROLLER

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

VAV Terminal Units SDS

Technical Documentation. LTG Fine Filters. Type CDF / UDF

Swegon PACIFIC. Integrated climate beam

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK

Swegon PACIFIC. Integrated climate beam QUICK FACTS KEY FIGURES

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Technical information

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC

McKenzie Martin Louvres & Ventilation Systems Louvres Maximair Louvre Systems Turret Louvres

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

C O L M A N. Air Distribution CIRCULAR DIFFUSERS LRS SERIES LRS SERIES

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

SDV Vane Swirl Diffusers

COMPLETE and FULLY INTEGRATED AIR PRESSURE CONTROL & MONITORING SYSTEMS

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

Variable Flow Rate Control Unit

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators. Type Explosion-proof actuators

Corrosion Resistant Polypropylene Fan Catalogue

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

Standard: for ceiling grid dimensions 1200 x 1200 mm, 1200 x 900 mm, 1200 x 600 mm. Other dimensions are available on demand.

Transcription:

.. 111 TROX UK LABCONTROL Facility

.. TROX Test Laboratory LABCONTROL Length = 9.0m Width = 4.0m Height = 4.0m Laboratory Facilities: The Lab is equipped with two Köttermann 1200mm wide general-purpose fume cupboards manufactured and tested in accordance with BS 7258, and DIN 12924. Each fume cupboard is fitted with a telescopic two piece sash with horizontally sliding windows In addition there are supplementary extract points which include an alsident arm and snorkel fitted above Köttermann furniture. The additional extract ports have been included to demonstrate TROX constant volume dampers 1

.. Laboratory Equipment: Supply System: The Lab supply system is designed to provide Variable Air Volume (VAV) and incorporates a TROX TVR volume flow damper complete with LON controller and fast modulating actuator. The system uses a centrifugal fan with a flexible control system, operating at an airflow range of 600 to 2900 m3/h. Room temperature, is conditioned by a thyristor controlled 6 kw electric heater and 5kW chilled water cooling coil. Supply air is diffused into the laboratory through three TROX SDW 600mm square swirl diffusers to provide between 216 m3/h and 684 m3/h. Exhaust System: The exhaust system also uses a centrifugal fan as detailed above, operating at an airflow range of between 700 to 3800 m3/h. The system has been designed to allow compensation air, through a TROX TVR damper, before being extracted from the Lab via a high level room egg crate grille. This arrangement allows for constant pressure control when the fume cupboards are extracting air at varying volume rates. Extract air from the fume cupboards, are controlled by TROX TVLK and Rlab dampers fitted with LON and analogue controllers respectively. In principle the exhaust system is subdivided into three different areas. 1) Extract grill operating on variable airflow, by using a TVR VAV Controller. 2) Alsident arm operating on fixed volume by using a RN CAV Controller. 3) Fume Cupboards operating on variable airflow by using the TVLK and RLab VAV Systems. TVLK - System (LON Digital): Rlab - System (Analogue): 1. TVLK, VAV Controller in Polypropylene RN Volume Controller in painted steel 2. Fume Cupboard Control System: Fume Cupboard Control System: TCU LON, Room Control Unit Fume Cupboard Controller FCCU FCCU-T Operator Terminal FCCU-T Operator Terminal FCC-E Velocity Transducer FCC-E Velocity Transducer 3. LON Router, Cable Networkand Software 2

.. Features Integrated control system Short length (400 mm) Connection diameter 250 mm Volume control via velocity sensor and VAV flow grid Externally removable sensors allow easy cleaning of flow grid All internal components in contact with contaminated air are manufactured using corrosive resistant plastic materials High accuracy in varying ambient temperatures Rapid actuation Features Integrated control system Length to suit diameter Length to suit diameter Modulates flow via fume cupboard mounted FCC-E velocity sensor Manufactured in steel with corrosive resistant painted metal components High accuracy in varying ambient temperatures Rapid actuation 3

.. Functional Characteristics As a basic principle the Laboratory area will be kept under a constant negative pressure at all times. The need for airflow modulation requires control of the supply system in relation to the extraction systems. BS 7258 stipulates that fume cupboards have to maintain an average face velocity of 0.5 m/s. By opening and closing the fume cupboard sash the volume flow will vary depending on its position. In order to ensure the correct face velocity of 0.5 m/s is kept, the extract air via the VAV system has to be adjusted, to keep a constant face velocity at all sash positions. Simultaneously the supplementary exhaust air is controlled, to allow the correct room air change rate and in conjunction with the supply system keep the room under the correct pressure. In today s changing environment, various controlling strategies are needed, and these have now been applied in many Research and Development facilities throughout the world. Our laboratories at TROX UK have been designed so that we can demonstrate many varying scenarios under different specified conditions. 4

.. 444 Design changes reserved. All rights reserved TROX UK Ltd (102/2015) TROX UK Ltd Caxton Way, Thetford Norfolk, IP24 3SQ Phone +44 (0)1842 754545 Fax +44 (0)1842 763051 E-Mail trox@troxuk.co.uk Internet www.troxuk.co.uk