Planning Low Voltage Layouts

Similar documents
SPECIFICATION SHEET. Transformers. Cable cord: Core: Timers & Photocell: Wire Rating: Certification: Warranty: OFF. Bottom mounting slot Front View

Low Voltage Lighting Power Supplies

General Purpose Buck - Boost Wiring Diagrams... 86

Fuse Blocks and Holders Fuse Block Technical Data Fuse Blocks 250 Volt E4 600 Volt E5 Cartridge Fuse Pullers Fuse Holders. ATC / Mini Fuse Tabs

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

LOW-VOLTAGE TRANSFORMER INSTALLATION GUIDE. Models: VTR-100SL-SS, VTR-150SL-SS, & VTR-300SL-SS

SECTION H WIRING DUCT WIRING DUCT Wilson Avenue, Toronto, Ontario, Canada, M9M 1A1 Ph: Fax:

OUTPUT CONNECTIONS Bring the wires of the light fixture through the other open knockout and connect them to the power supply output wires.

DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features

HPS Fusion General Purpose Enclosed Transformer

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

Wired Maestro Local Controls

Hi-lume Overview. EcoSystem Hi-lume 1% Architectural Dimming

Care & Usage Manual For Your Outdoor Lighting System

MLT T-RPC. Supplied with mounting plate & hardware for easy installation (key slotted back)

Installation Manual CS9100-LED. Professional Series Landscape Lighting System

Tu-Wire Overview. Fluorescent Dimming Ballasts Tu-Wire 5% High-Performance Dimming

JUNCTION / DECK BOX. - Made of white ABS and push in cover with O-ring seal IP 55 weather protection.

IMPROVED LIGHTING CONTROLS

DUALBRITE Motion Sensing Coach Light

USER MANUAL 12 OUTLET 120/240V X-PLUG LIGHT CONTROLLER (FUEL SX12) APTX0120

- Wiring Brochure tekmarnet 4 Thermostat 545

- Application A Mixing Setpoint Control 153. Mechanical. Electrical 12/08

VERTIV XTE 401 SERIES. Ordering Guide

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

systems Systems Emergency Lighting Inverter 120 or 277V 60 Hz Power

HIGH INTENSITY DISCHARGE BALLASTS

- Wiring Brochure Universal Reset Module 422

Installation Manual. CS9300 Professional Series Landscape Lighting System

OUTDOOR TRACK. LABELS Assembled in America

STL. Series. Emergency Lighting Inverter 3kW to 160kW Central System

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

HEAVY DUTY POWER RELAYS FEATURES

6.1. Lighting Contactors. Contents. Application Description. Product Overview. Open Control

INSTALLATION GUIDES OUTDOOR LIVING

- Wiring Brochure Universal Reset Module 422e

Phoenix Inverter

SAVE THESE INSTRUCTIONS

Transformers for Low-voltage Halogen Incandescent Lamps

An energy saver combines energy saving & a compact design

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS

Electro Controls. Fan Speed Controls WattsIndustries.co.uk

Product Manual Manuel du Produit Manual del Producto

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

AFL FLOODLIGHT SERIES

INSTALLATION. **Microprocessor Status LED:

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

MODEL 422 Submersible Pump Controller

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

Wiring Diagrams (Including Accessories) (50/60 Hz)

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

Compact designs, unlimited possibilities

LED Auxiliary Devices

Compact designs, unlimited possibilities

INSTALLATION INSTRUCTION Magnetic Transformer

1000W and 2000W versions

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

ELECTRICAL SYSTEM RP-7

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

diode led 24VDC MAGNETIC DIMMABLE DRIVER SPECIFICATION SHEET 24VDC OVERVIEW FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

QuickSpecs. HP 480/277 Volt Solutions. Overview

FL Halogen light generator for use with fibre optic lighting. Mounting and installation instruction. Item no.: FL 20-2 Ø9 230V

DekPro EFFEX. Post Cap and Lighting Guide.

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate

GLX. Series. 1kW to 16kW Central System

Machine Tool Industrial Control Transformers

Skylark C L Dimmer. Skylark. Wallbox Controls. Dimmer for CFL and LED dimmable bulbs.

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h

Motion Sensing Coach Light

Practical and completely safe

HomeWorks QS Designer RF Maestro Local Controls

FL B. Halogen light generator for Fibre optic lighting systems

CI-TI Contactors and motor starters Types CI 61 - CI 98

Wired Vareo Local Lighting Controls

1 Phase electronic contactor (SC 1)

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Connect30 ipad, Chromebook, and Notebook Cart

Compact designs, unlimited possibilities

HPS Imperator Series Control Transformers meet or exceed the standards established

HPS Fusion General Purpose Enclosed Transformer

PH250MQMJ CNTL 250VA 240X X240

Horizontal Circuit Switchers

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Horizontal Circuit Switchers

Explosion Proof Drop Light - 12 Volt AC/DC Watt Incandescent - 25' Cord - Twist Lock Plug

Standard Grade 14 Inch Reflector. Ordering Information

Commercial Garage Door & Gate Operators

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Wanco Light Towers. The industry leader

Q-VAULT Installation Instructions. Q-Tran, Inc. Milford, CT

Product Manual Manuel du Produit Manual del Producto

TRAILER AUXILIARY POWER SYSTEM (TAPS) INSTALLATION GUIDE V1.10

Engineered solutions for power and the environment

Cloud32 Chromebook Cart

eshine Flood Lamps Technical Data

Transcription:

Outdoor_ransformers_Outdoor_ransformers.qxd 11-11-10 3:40 PM Page 1 1850 Wilson Avenue, oronto, Ontario, anada, M9M 1A1 Ph: 416-741-7336 Fax: 416-741-9104 SEION H OUDOOR H1 OUDOOR Low Voltage ransformers - Overview 12VA to 36VA Small ase ransformers 60VA to 150VA Replaceable Fuse ransformers 45VA to 60VA Small ase ransformers 60VA to 100VA Small ase ransformers 200VA to 900VA Metal ase ransformers 300VA to 900VA Metal ase ransformers Planning Low Voltage Layouts H2 H3 H3 H4 H5 H6 H7 H8 Etlin-Daniels reserves the right to discontinue, modify designs and change specifications without incurring obligation. While every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error herein. opyright 2011 Etlin-Daniels

Outdoor_ransformers_Outdoor_ransformers.qxd 11-11-10 3:40 PM Page 2 Outdoor ransformers H2 Outdoor Low Voltage ransformers for Landscape Lighting Systems We offer a complete line of outdoor low voltage transformers for use with incandescent and halogen landscape lighting fixtures. hese lass 2 isolation transformers offer safety and energy efficiency over line voltage products. Models are available with timer and photocell for added convenience and versatility. Most feature thermal and resetable circuit breakers should the units overheat or overload. ommon features for the whole series: Reliable quality transformer guaranteed for five years Rugged core and coil design for years of trouble free operation that you can count on Whisper quiet operation even when dimmed an be fully loaded and dimmed using a low cost incandescent dimmer Easy to wire terminal blocks or male tabs ompact case sizes to allow more flexibility when installing the transformers an be used indoor or outdoor Easy mounting using key hole slots c UL us listed he lower wattage models up to 100VA feature the following: 120V to 12V for low voltage garden lighting High quality electrical steel laminations for increased efficiency and lower operating costs he 200 to 900VA models feature the following: 120V to 12V for low voltage garden lighting erminal block for easy wiring High quality electrical steel laminations for increased efficiency and lower operating costs Photocell operation - on at dusk, off at dawn High impact plastic cases 6 6 SJW power cord Male tabs for easy wiring using crimp terminals High quality powder coated steel enclosure for superior corrosion resistance ompact design for increased mounting flexibility Easy wall mounting using key hole slots Features short circuit and thermal overload protection for fail safe operation ompact size which mounts easily Some models feature photocell, timer, or manual switch combinations to be as full featured as the system requires Dead front output cover with easy access wiring compartment on the base Front cover window allows viewing of timer and protection of the photocell Electronic timer can be set to remain on for up to 8 hours after coming on at dusk Small Units 88/100 VA Units 200/300 VA Units

Outdoor_ransformers_Outdoor_ransformers.qxd 11-11-10 3:40 PM Page 3 12VA to 150VA Models DA-XX-12W Series - 12 to 36VA Small ase Low Voltage H3 Model Number Input Voltage Output Output Output ase Size Weight in Output erminals and Hertz Voltage urrent Watts L W H Pounds DA-12-12W 120V @ 60Hz 12VA 1.00A 12VA 4.05 2.50 1.90 1.18 2-.250 X.032 male tabs DA-22-12W 120V @ 60Hz 12VA 1.83A 22VA 4.05 2.50 1.90 1.44 2-.250 X.032 male tabs DA-30-12W 120V @ 60Hz 12VA 2.50A 30VA 4.45 2.87 2.20 1.59 2-.250 X.032 male tabs DA-36-12W 120V @ 60Hz 12VA 3.00A 36VA 4.45 2.87 2.20 1.87 2-.250 X.032 male tabs High impact plastic cases ompact size which mounts easily 6 6 SJW 18/2 power cord DA-XX-12W Series - 60 to 150VA Small ase Low Voltage with replaceable fuse Model Number Input Voltage Output Output Output ase Size Weight in Output Leads and Hertz Voltage urrent Watts L W H Pounds DA-60-12W 120V @ 60Hz 12VA 5.00A 60VA 5.03 2.70 2.99 2.51 6 6 of SP 18/2 wire DA-60-24W 120V @ 60Hz 24VA 2.50A 60VA 5.03 2.70 2.99 2.51 6 6 of SP 18/2 wire DA-100-12W 120V @ 60Hz 12VA 8.33A 100VA 5.43 3.62 2.68 4.01 6 6 of SP 18/2 wire DA-100-24W 120V @ 60Hz 24VA 4.17A 100VA 5.43 3.62 2.68 4.01 6 6 of SP 18/2 wire DA-150-12W 120V @ 60Hz 12VA 12.5A 150VA 5.79 3.43 3.39 5.13 6 6 of SP 18/2 wire DA-150-24W 120V @ 60Hz 24VA 6.25A 150VA 5.79 3.43 3.39 5.13 6 6 of SP 18/2 wire High impact plastic cases ompact size which mounts easily 6 6 SJW 18/2 power cord Replaceable fuse

Outdoor_ransformers_Outdoor_ransformers.qxd 11-11-10 3:40 PM Page 4 45 to 60VA Models H4 45 to 60VA Small ase Low Voltage Length Photo Sensor Width Height imer Switch AUO 8H 4H 6H Model Input Voltage Output Output Output ase Size Weight in Output erminals ontrol Number and Hertz Voltage urrent Watts L W H Pounds Devices DA-45-12W-1 120V @ 60Hz 12VA 3.75A 45VA 6.22 3.66 2.87 2.33 2-.250 X.032 male tabs Photo / imer DA-45-12W-2 120V @ 60Hz 12VA 3.75A 45VA 6.22 3.66 2.87 2.33 2-.250 X.032 male tabs imer only DA-45-12W-3 120V @ 60Hz 12VA 3.75A 45VA 6.22 3.66 2.87 2.33 2-.250 X.032 male tabs Photo Switch DA-52-12W-1 120V @ 60Hz 12VA 4.33A 52VA 6.22 3.66 2.87 3.10 2-.250 X.032 male tabs Photo / imer DA-52-12W-2 120V @ 60Hz 12VA 4.33A 52VA 6.22 3.66 2.87 3.10 2-.250 X.032 male tabs imer only DA-52-12W-3 120V @ 60Hz 12VA 4.33A 52VA 6.22 3.66 2.87 3.10 2-.250 X.032 male tabs Photo Switch DA-60-12W-1 120V @ 60Hz 12VA 5.00A 60VA 6.22 3.66 2.87 3.85 2-.250 X.032 male tabs Photo / imer DA-60-12W-2 120V @ 60Hz 12VA 5.00A 60VA 6.22 3.66 2.87 3.85 2-.250 X.032 male tabs imer only DA-60-12W-3 120V @ 60Hz 12VA 5.00A 60VA 6.22 3.66 2.87 3.85 2-.250 X.032 male tabs Photo Switch High impact plastic ases ompact size which mounts easily 6 6 SJW 18/2 power cord Photocell switch and timer models - come on at dusk and can be set to stay on for 4/6/8 hours or auto shut off at dawn imer only models - are manually turned on and can be set to stay on 4/6/8 hours and then automatically shut off Photocell only models - automatically come on at dusk and turn off at dawn

Outdoor_ransformers_Outdoor_ransformers.qxd 11-11-10 3:40 PM Page 5 60 to 100VA Models 60 to 100VA Small ase Low Voltage H5 Model Number Input Voltage Output Output Output ase Size Weight in Output erminals ontrol and Hertz Voltage urrent Watts L W H Pounds Devices DA-60-12WH-1 120V @ 60Hz 12VA 5.00A 60VA 5.90 3.58 3.46 3.14 2 Pole 18-12awg erminal Block Photo / imer DA-60-12WH-2 120V @ 60Hz 12VA 5.00A 60VA 5.90 3.58 3.46 3.14 2 Pole 18-12awg erminal Block imer only DA-60-12WH-3 120V @ 60Hz 12VA 5.00A 60VA 5.90 3.58 3.46 3.14 2 Pole 18-12awg erminal Block Photo Switch DA-88-12WH-1 120V @ 60Hz 12VA 7.33A 88VA 5.90 3.58 3.46 3.90 2 Pole 18-12awg erminal Block Photo / imer DA-88-12WH-2 120V @ 60Hz 12VA 7.33A 88VA 5.90 3.58 3.46 3.90 2 Pole 18-12awg erminal Block imer only DA-88-12WH-3 120V @ 60Hz 12VA 7.33A 88VA 5.90 3.58 3.46 3.90 2 Pole 18-12awg erminal Block Photo Switch DA-100-12WH-1 120V @ 60Hz 12VA 8.33A 100VA 5.90 3.58 3.46 4.66 2 Pole 18-12awg erminal Block Photo / imer DA-100-12WH-2 120V @ 60Hz 12VA 8.33A 100VA 5.90 3.58 3.46 4.66 2 Pole 18-12awg erminal Block imer only DA-100-12WH-3 120V @ 60Hz 12VA 8.33A 100VA 5.90 3.58 3.46 4.66 2 Pole 18-12awg erminal Block Photo Switch High impact plastic ases ompact size which mounts easily 6 6 SJW 18/2 power cord Resetable circuit breaker on the output side to protect against overload Hinged cover to protect controls and give easy access Photocell switch and timer models - come on at dusk and can be set to stay on for 4/6/8 hours or auto shut off at dawn imer only models - are manually turned on and can be set to stay on 4/6/8 hours and then automatically shut off Photocell only models - automatically come on at dusk and turn off at dawn

Outdoor_ransformers_Outdoor_ransformers.qxd 11-11-10 3:40 PM Page 6 200 to 900VA Models H6 200 to 900VA Metal ase Low Voltage Model Number Input Voltage Output Output Output ase Size Weight in Output erminals and Hertz Voltage urrent Watts L W H Pounds PS-20012 120V @ 60Hz 12VA 16.7A 200VA 8.85 5.00 5.00 11.8 Split load screw terminal block PS-30012 120V @ 60Hz 12VA 25.0A 300VA 8.85 5.00 5.00 14.1 Split load screw terminal block PS-60012 120V @ 60Hz 12VA 50.0A 600VA 14.45 5.00 5.00 23.1 Split load screw terminal block PS-90012 120V @ 60Hz 12VA 75.0A 900VA 12.10 9.88 5.43 36.4 Split load screw terminal block he 200, 300, 600, and 900 VA models feature the following: High quality power coated steel enclosure for superior corrosion resistance 120V to 12V for low voltage garden lighting erminal block for easy wiring High quality electrical steel laminations for increased efficiency and lower operating costs Features short circuit and termal overload protection for fail safe ompact design for increased mounting flexibility Easy wall mounting using key hole slot Dead front cover with easy access wiring compartment on the base Front cover window allows viewing of timer and protection of the photocell operation Photocell switch and timer models - come on at dusk and can be set to stay on 4/6/8 hours or auto shut off at dawn

Outdoor_ransformers_Outdoor_ransformers.qxd 11-11-10 3:40 PM Page 7 300 to 900VA Models 300 to 900VA Metal ase Low Voltage H7 he 300, 600 and 900 VA models feature the following: 120V for low voltage garden lighting ontrol can be programmed to stay on 4/6/8 hours and off at dawn. High quality electrical steel laminations for increased efficiency and lower operating costs Features short circuit and termal overload protection for fail safe operation Relocatable photocell that can be mounted in direct ambient light for reliable operation. High quality power coated steel enclosure for superior corrosion resistance ompact design for increased mounting flexibility Easy wall mounting using key hole slots on enclosure. Dead front cover with easy access wiring compartment on the base Large heavy duty terminal blocks for easy wiring. Product Number PS-300-12W4-1S PS-600-12W4-1S PS-900-12W4-1S Power Rating (W) 335 670 1005 Input Voltage (v) 120 120 120 Frequency (Hz) 60 60 60 Output Voltage (v) 12.0/12.0/13.0/14.0 11.5/12.0/13.0/13.0 11.5/12.0/13.0/13.0 Output urrent (A) 26/25.3/24.4/23.5 25.6/25.6/25/24 26/25/25/24 Output Voltage 12/13/14/15 12/13/14/15 12/13/14/15 Without Load (v) Operating emp. () 100to 40 /14 to 104 F 100to 40 /14 to 104 F 100to 40 /14 to 104 F Dimensions: Length 10.5 / 266.2cm 10.5 / 266.2cm 10.5 / 266.2cm Width 5.0 / 127cm 8.6 / 220cm 14.5 / 367.5cm Height 4.9 / 125.0cm 4.9 / 125.0cm 5.3 / 135.0cm Weight in Pounds 15.3lbs / 6.97 kg 26.8lbs / 12.7 kg 44.2lbs / 20.1 kg Output erminals om/12/12/14/15 om/12/12/14/15 300Va om/12/12/14/15 300Va Photocell Relocatable with SP-1 18/2 8 long 2 hole srew mount Also available in Stainless Steel Enclosure for added corrosion protection - add suffix -SS. Relocatable with SP-1 18/2 8 long 2 hole srew mount om/12/12/14/15 300Va om/12/12/14/15 300Va om/12/12/14/15 300Va Relocatable with SP-1 18/2 8 long 2 hole srew mount

Outdoor_ransformers_Outdoor_ransformers.qxd 11-11-10 3:40 PM Page 8 Planning Outdoor Low Voltage ransformers Layouts 300 to 900VA Models H8 Planning Low Voltage Layouts Low Voltage Systems Sytems require the use of a transformer to reduce standard volt power from your home to 12 volts. Select a transformer that matches as closely as possible the total lamp wattage by adding the wattages of all lamps that are going to be a part of the system. otal lamp load should not be less than 1/3 of the transformer s wattage rating, nor exceed the maximum wattage capacity. If the total wattage is too high, either divide the load between two transformers or use a more powerful transformer. he closer the lamps are placed to the transformer, the higher their voltage and wattage. When a cable run is too long or there are too many lights being powered by a single transformer, noticable voltage drop may occur resulting in dim lights. Planning Low Voltage Layouts hese diagrams show some of the most common low voltage cable layouts. hoice of layout can help minimize voltage drop. Straight Run Installation Loop Installation Split Load Installation I Installation Fixtures run in sequence directly from the transformer in series. Helps reduce voltage drop and produces a more uniform light output. It is important that you connect the same wire leads to the proper transformer terminals by noting the ridge or marking on one side of the cable. Run up to the recommended maximum cable length in two or more direct lines from the transformer. Allows more equal distribution of power to the center of a run, or to run the distance away. able running from transformer must be of a heavier gauge such as 10 gauge.