IFPAC 2003 Dr. Berthold Andres

Similar documents
Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Setting up SilFlow for BackFlush in your GC

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

GC Method Compliance and Large Valve Oven Application

Ultra-Small Absolute Pressure Sensor Using WLP

New Small Spectrometer Concepts Covering the Ultraviolet to the Mid-Infrared

2F MEMS Proportional Pneumatic Valve

Application. Gas Chromatography June 1995

DANI Transformer Oil Gas Analyzer

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

GC-101. Testing of Biodiesel Using Gas Chromatography. by Bob Armantrout. Presented at: Local Biodiesel: A Biodiesel Coop Conference

THC Heated FID 3-300A

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

NEW TECHNOLOGIES IN COLD CHAMBER DIE CASTING PROCESS ACCORDING TO INDUSTRY 4.0

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Agilent G5632 Valve Kit Instructions

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Technical Procedure for Gas Chromatography (GC-FID)

AZ Chrom s.r.o.

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

2-D GC/MS and the Deans Switch: Theory and Applications. Fred Feyerherm, Agilent Technologies Inc. Houston, Tx

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

Choose for Your Instrument. GC Supplies - Agilent Instrument Quick Pick Guide

MEMS Vibrational Energy Harvester for Wireless Sensor Power

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

ASTM D 6730 Detailed Hydrocarbon Analysis

Ultrafast GC Performance in the Real World: Multi Lab Studies for Repeatability & Reproducibility

PVC1000 Series. Microsystems, Inc. Pirani Vacuum Sensors. PVC1000 Series. Description. Features. Applications. Absolute Maximum Ratings

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

GC Supplies - Varian/Bruker Instrument Quick Pick Guide

Portable TOC Analyser for Stack Emissions

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

Gas chromatography technology advancement: the new ABB PGC 5000 Marco Quiles

Agilent 7693A Automated Liquid Sampler

Using the PSD for Backflushing on the Agilent 8890 GC System

FEATURE ARTICLE. Advanced Function Analyzers: Real-time Measurement of Particulate Matter Using Flame Ionization Detectors. Hirokazu Fukushima

Agilent Valve Kit G4231A/B and G4232A/B/C

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

Method Detection Limits for EPA Method 8015 Diesel Range Organics using Fully Automated Extraction and Concentration

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Hybrid MEMS Pneumatic Proportional Control Valve

Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Application Note. Abstract. Authors. Environmental Analysis

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

TURBOVAC i Multi Inlet Line Turbomolecular pumps

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Latest technology standard for high-speed cell & wafer handling

Agilent 7693A Automated Liquid Sampler

Choose for Your Instrument. GC Supplies - Bruker (Varian) Instrument Quick Pick Guide

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Agilent Multimode Inlet for Gas Chromatography

Instruments and sensors for Periodic Technical Inspection (PTI) with DPF-equipped vehicles and Kerbside Control

GLOW PLUG INTEGRATED CYLINDER PRESSURE SENSOR FOR CLOSED LOOP ENGINE CONTROL

Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)

Online sample cleanup on the Agilent 1290 Infinity LC using a built in 2-position/6-port valve

Agilent Valve Kit G4231A/B/C and G4232B/C/D

Present Status and Prospects for Fuji Electric s IC Products and Technologies Yoshio Tsuruta Eiji Kuroda

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard

Extra-High-Voltage SF 6 Gas-Insulated Switchgear

For more information about Agilent Technologies services please visit our web site using the following URL

C2, C3, C4 Monomer Analysis

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

MagneMotion Maglev Demonstration on ODU Guideway

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Trends in Automotive MEMS. Dr. Jan Peter Stadler Senior Vice President Engineering, Robert Bosch GmbH

Load Cell for Manually Operated Presses Model 8451

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

Piston spool valves and poppet valves - A technical comparison of available solenoid valves

ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT. PGC1000 Meeting the needs of NGL plants

Performing ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

FEATURES AND BENEFITS

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Installing the 6850 Direct Valve Column Connector Kit

Ultra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS

Nickel Catalyst Tube on a 6820 GC, Accessory G4318A

Development of Low-thrust Thruster with World's Highest Performance Contributing to Life Extension of Artificial Satellites

Monitor Chlorine in Crude at Sub-ppm Levels

Rosemount 570 Natural Gas Chromatograph

Surface MEMS Design Examples Dr. Lynn Fuller Webpage:

Reducing Train Weight and Simplifying Train Design by Using Active Redundancy of Static Inverters for the Onboard Supply of Rolling Stock

Optical Techniques in Gasoline Engine Performance and Emissions Development Injector Spray Visualisation

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

LEVER OPTIMIZATION FOR TORQUE STANDARD MACHINES

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

Application Note. Authors. Abstract. Energy & Chemicals

Proposal to establish a laboratory for combustion studies

AZ Chrom s.r.o.

Transcription:

IFPAC 2003 Dr. Berthold Andres ABB Automation Products Germany Microelectromechanical Systems for Process Analytics Copyright 2002 ABB. All rights reserved. -

Process Analyzer and Instrumentation Water analysis Gas analysis Pressure transmitter Flow transmitter Copyright 2002 ABB Automation - 2 -

Agenda Copyright 2002 ABB Automation - 3 - What are Microelectromechanical Systems (MEMS) Why use MEMS technology for process analytical ABB MEMS Projects Summary

What are Microelectromechanical System? Microelectromechanical System (MEMS) is a miniaturization technique based upon silicon wafer technology. This technology is a departure from the historical emphasis on the miniaturization of existing electrical, optical and mechanical assemblies Examples Copyright 2002 ABB Automation - 4 -

Why use MEMS in Process Analytical? Small is beautiful!! Copyright 2002 ABB Automation - 5-5 mm Size effects: Cost of manufacturing Cost of Installation Analyzer Location Sampling systems Shelters

Why use MEMS in Process Analytical? Copyright 2002 ABB Automation - 6 - Manufactured in silicon wafer processes Highly reproducible Lower manufacturing cost for larger quantities Significantly smaller sizes Less consumables longer time of operation Lower power demand Portability Installation at the source Faster response time possible Smaller dead volume Lower mass Shorter diffusion length Designed as integrated assemblies Further reduced size Reduced number of components Reduced integration time Faster cycle time Exchangeability of complete subassemblies Maintenance is simplified

Where to use MEMS in Process Analytical? Two Types of MEMS Projects Analyzer Components Moderate Risk, High Reward Detectors, Valves, columns, ionization chambers,. Complete MEMS Analyzers High Risk, High Reward GC, MS, Titration,. Copyright 2002 ABB Automation - 7 -

1994: Our first introduction of a MEMS sensor Development of a Thermal Conductivity Detector (TCD) for gas analysis (e.g. Hydrogen in air, CO2 in air) Conventional design MEMS design 100 mm 10 mm Copyright 2002 ABB Automation - 8 - Designed as an integrated detector with Thin-film measuring resistor Thin-film reference resistor Membrane to control gas flow through detector Size ~ 2 sq mm Housing and electronics are added in the next step

Thermal Conductivity Analyzer, Summary Copyright 2002 ABB Automation - 9 - Development was a big success Several thousands sold since introduction Drivers for success Size of TCD detector can be minimized without loosing sensitivity Better technical data because of smaller size Smaller thermal capacity of detector Faster response time We already knew the application from our standard detectors Simple design of the detector. Housing and pneumatical connections are added in another production process Market size is just large enough for the MEMS production Current drawback It is difficult to control the production process for small quantities over a longer period of time (thousand is still a small number for a MEMS process)

Realization of Micro GC with MEMS Components Copyright 2002 ABB Automation - 10 -

Micro-Valve Technical Specifications Micro ball valve Electromechanically activated Ball size ~ 500 µm Plasma etching to get high precision valve seat Pressure range < 2 bar Power consumption < 300 mw Copyright 2002 ABB Automation - 11 -

Micro Valve Array is required for Micro-GC Integration of multiple micro ball valves => Realization of dedicated flow schemes Copyright 2002 ABB Automation - 12 - Summary Micro ball valves can be produced But: Production of micro ball valve arrays is very complex, overall yield is too low

Micro Flame Ionization Detector for Micro-GC Designed as an integrated detector silicon-glass technology integrated sample injection system integrated gold electrodes quartz capillary connectors Copyright 2002 ABB Automation - 13 - Conventional design MEMS design 5 mm

Flame Ionization Detector, Summary Micro-FID has been built and is running Micro-FID shows typical problem of MEMS technology that not everything can be simply scaled down Quenching distance between flame and electrodes does not allow to reduce size of flame substantially Copyright 2002 ABB Automation - 14 - Current Micro FID has no substantial benefits compared to conventionally manufactured system

MEMS Thermal Conductivity Detector for Micro-GC Advantages: Small Thermal Capacity Small Dead Volume 1 mm Copyright 2002 ABB Automation - 15 - Fast Response Time < 10 ms Low Detection Limit < 10 ppm

MEMS GC, Summary Copyright 2002 ABB Automation - 16 - Single components can be successfully designed Complete GC Very complicate to go from prototypes to production Each component must be developed and trouble shot as an individual The integration of individual components is a second project and very complicated GC Market Volumes are not compatible with MEMS

Next step: Concept for Micro-Mass-Spectrometer Target: MMS with the size of a cellular phone to driving electronics measurant acceleration electrode ionization chamber ions ion optics mass separator Copyright 2002 ABB Automation - 17 - Plasma Ion source acceleration grid noble gas e plasma to pump deflection electrodes to pump detector to detection electronics No UHV required! Separator with 1mm length

MEMS Mass-Spectrometer, Objectives Copyright 2002 ABB Automation - 18 - Measuring principle or component must be scalable ok for MS Concentrate on crucial parts of the system design where the MEMS technology can show all its advantages e.g. mass separator Yield for MEMS processes, especially for difficult structures, is not always 100 % MEMS should be split to several components which can be tested individually

MEMS Conclusions Copyright 2002 ABB Automation - 19 - ABB has been successful at targeting analyzer components for the conversion to MEMS technology Success comes from the use of MEMS components in conventional or miniature systems Total integrated MEMS systems may require too much time to get out of the lab and become a real product