Model P772 Conductivity Meter. User Manual

Similar documents
Model 1672, 1673 Triple Output Power Supply

Model 1693, 1694 Switching DC Power Supply

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Model 1900, 1901, 1902 Switching DC Power Supply

Triple Output High Resolution Power Supply. User Manual

DC REGULATED POWER SUPPLY

Model 1900, 1901, 1902 Switching DC Power Supply

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

SLA Battery Capacity Analyzer

Switching DC Power Supply

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

Triple Output Power Supply

EC20 Pocket Conductivity Tester Instruction Manual

Instruction Manual. Model 310 Digital Milli-Ohm Meter

EC1 Pocket Conductivity Tester Instruction Manual

TDSscan10M Pocket TDS Tester Instruction Manual

PH60 Series Premium ph Testers

Salt 1 Pocket Salinity Tester Instruction Manual

Megohmmeter Test Probe

ECscan10H Pocket Conductivity Tester. Instruction Manual BANTE INSTRUMENTS LIMITED

ECscan20 Pocket Conductivity Tester Instruction Manual

COM-100 EC / TDS / TEMPERATURE METER

TIME-10 Process Control Stopwatch

Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

WalkLAB Digital Dissolved Oxygen meter HD9030

Delmhorst Instrument Co. Model HT-3000 Thermo-Hygrometer. Owners Manual

TACH-10 Contact / Non-Contact Tachometer

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

362 Clamp Meter. Users Manual

Large Display ph Pens , , Instruction Manual

TESTER SET SOCKET & VOLTAGE

G-34 HOPS MOISTURE METER OPERATION MANUAL. DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s-hertogenbosch THE NETHERLANDS

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

This manual covers the following model:

PSX-240 Enclosed Autotransformer Installation Manual

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Spotlight 1,000,000 Power Series Cordless Rechargeable

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

ORPscan20 Pocket ORP Tester Instruction Manual

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

HT owners manual WHEN ACCURACY IS THE POINT.

ECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual

OWNER S MANUAL & WARRANTY INFORMATION IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS

PHscan10S Pocket ph Tester Instruction Manual

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Operation & Installation Guide 2087DF / 2092DF. Manual # M DIGITAL WATERPROOF. Manual # M

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

PVI 60KW, PVI 82KW, PVI 95KW

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

DC REGULATED POWER SUPPLY

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

PY-11 Voltage & Continuity Tester

Tracer ORP PockeTester TM Code 1742

PHscan30S Pocket ph Meter Instruction Manual

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

Digital Body Weight Scale Model No.: EB4074C. Questions or Concerns? (855)

HanTron Model HT-3P. Manual. Installation Maintenance Repair Manual

Thermaltake Warranty / Support Information

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

Go to to register your product and find more information.

Power. On Your Terms.

AXD 530 MicroManometer

QSI (Q-Star) Electronics Owner s Manual

Crestron MMK-G1-CBF-T Mud Ring Mount Kit for Cameo Installation Guide

CORDED CORDLESS RECHARGEABLE

Model 2053 Conductivity Meter Instruction Manual

TRACER. POCKETESTER ä ORP CODE 1742

Digital Body Weight Scale

Digital Body Weight Scale Model No. EB4074C. Questions or Concerns? (855)

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY

PIN-TYPE LCD MOISTURE METER

2087F-BD / 2092F-BD. COMBINATION WATERPROOF FIRE SAFE with Ready-Seal. Operation & Installation Guide. Manual # M

10 Year Limited Warranty

ROTARY HEAD DIGITAL STEM THERMOMETER

Operation & Installation Guide 2087F / 2092F. Manual # M Manual # M

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

RECHARGEABLE 24 LED WORK LIGHT

Calibration Manual. Detachable Jaw True-rms Clamp Meter

flexible infrared thermometer

THWD-3 and TH-3 Relative Humidity and Temperature Meters

OWNER S MANUAL & WARRANTY INFORMATION

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Model FM2642 Wall Mount. Full Motion Television Wall Mount

MANLEY LABORATORIES, INC. MANLEY REFERENCE JUNIOR DAC OWNER'S MANUAL 20 BIT DIGITAL TO ANALOG CONVERTER

Q Flood 7500 Rugged Battery powered LED User s Manual

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

Thermo-Anenometer Model Owner s Manual

HI Portable Waterproof Skin ph Meter INSTRUCTION MANUAL

Visit us at

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

PH20 Value ph Tester Instruction Manual

Transcription:

Model P772 Conductivity Meter User Manual

1 Table of Contents 1 INTRODUCTION... 1 2 SAFETY SUMMARY... 2 3 COMPLIANCE STATEMENTS... 2 4 PRODUCT CONTENTS AND INSPECTION... 3 5 DEVICE DESCRIPTION... 4 6 OPERATING INSTRUCTIONS... 4 6.1 PREPARATION... 4 6.2 CALIBRATION... 4 6.3 MEASURING WITH THE CONDUCTIVITY METER... 4 6.4 CHANGING THE BATTERY... 5 6.5 ELECTRODE REPLACEMENT... 5 7 TECHNICAL SPECIFICATIONS... 5 8 MAINTENANCE... 6 9 SERVICE INFORMATION... 6 9.1 SERVICE, REPAIR, OR CALIBRATIONS... 6 9.2 WARRANTY... 7 1 Introduction The P772 is a wide-range, pocket-sized conductivity meter perfect for use in field environments such as: Hydroponics Fish farming Agriculture Swimming pools and spas Waste water systems Plating industry Food industry Pharmaceutical and Medical Cooling towers Chemical industry Having a rugged, waterproof housing, and replaceable electrodes, this meter will give long durable service. With 10 µs/cm resolution and ±2% FS accuracy, you will have high quality results at your fingertips. Automatic temperature compensation (ATC) adjusts for changes in conductivity due to temperature.

2 Features Resolution: 10 µs/cm High accuracy: ±2% Full Scale Measures 0~19990 µs/cm Rugged waterproof housing (meets IP57 standards) Compact size fits easily into your pocket Automatic temperature compensation Replaceable electrodes (not covered under warranty) Large 21 x 18 mm LCD display Easy 1-point calibration with included calibration solution Comes ready-to-go with two long-life 3-V Lithium batteries 2 Safety Summary Be sure the temperature and humidity are within the limits indicated in the Technical Specifications section of this manual. Avoid making measurements in the presence of explosive gas, combustible gas, steam or excessive dust. Do not install substitute parts or perform any unauthorized modifications to this instrument. Return the instrument to Anaheim Scientific for service and repair to ensure that safety features are maintained. The following symbols are used in this manual: This symbol on an instrument indicates that the user should refer to the operating instructions located in the manual. The meter is in compliance to the CE mark standards 3 Compliance Statements Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with separate collection systems)

3 This product is subject to Directive 2002/96/EC of the European Parliament and the Council of the European Union on waste electrical and electronic equipment (WEEE), and in jurisdictions adopting that Directive, is marked as being put on the market after August 13, 2005, and should not be disposed of as unsorted municipal waste. Please utilize your local WEEE collection facilities in the disposition of this product and otherwise observe all applicable requirements. 4 Product Contents and Inspection This unit is tested prior to shipment. It is therefore ready for immediate use upon receipt. An initial physical inspection should be made to ensure that no damage has been sustained during shipment. Inspect the packing box on receipt for any external damage. If any external damage is evident, remove the instrument and visually inspect its case and parts for any damage. If damage to the instrument is evident, a description of the damage should be noted on the carrier s receipt and signed by the driver or carrier agent. Save all shipping packaging for inspection. Forward a report of any damage to the agent through which the unit is procured. Retain the original packing in case subsequent repackaging for return is required. Use of the original packing is essential. After the mechanical inspection, verify the contents of the shipment. The items included in this package are: P772 Conductivity meter Two 3V Batteries (already installed) Instruction manual Calibration solution Calibration screwdriver Gift box

1 4 5 Device Description 2 1) Battery compartment cap 2) Main display 3) Power button 4) Electrode collar 5) Electrode module 6) Electrode 7) Protective cap 7 3 4 6 Operating Instructions 6 5 6.1 Preparation 1. Remove the protective cap from the meter to rinse the electrode with clean water and then wipe it dry. Do not touch or wipe the surface of the inner black sensor of the electrode. 2. Open the battery compartment to take out the screwdriver. 3. Press the button to turn the meter power on. 6.2 Calibration 1. Dip the electrode into the calibration solution. Stir gently and wait until the display is stabilized. Adjust the reading to 141 (1413 µs/cm) at 25 by turning the trimmer (Span) located at left side of battery compartment with the calibration screwdriver. 2. Calibration is complete. 3. There is no need to calibrate before each usage. Calibration should be performed every two weeks or after 10 times of usage. 6.3 Measuring with the Conductivity Meter 1. After calibration, rinse the electrode with clean water and wipe it dry. Do not touch or wipe the surface of the inner black sensor of the electrode. Dip the electrode into the sample solution to be measured. Stir gently and wait until a stable reading can be obtained.

5 2. Read the measurement on the display. The reading should be multiplied by a factor of 10 to obtain the true conductivity value. 3. After measurement, rinse the electrode with clean water and replace the protective cap. Do not touch or wipe the surface of the inner black sensor of the electrode. 6.4 Changing the battery 1. The installed Lithium CR2032 batteries have a typical life span of 100 hours. Replace the battery when the display begins to fade or flash. 2. Loosen the battery compartment cap. 3. Replace the old batteries with fresh Lithium CR2032 batteries, noting the polarity. 4. Replace the battery compartment cap tightly. 5. Recalibrate the meter after changing the batteries. 6.5 Electrode Replacement 1. As long as the electrode can be calibrated and remains responsive it is still useful. When either of these begin to fail, you will need to replace the electrode. (This is not covered under the warranty). 2. Unscrew the electrode collar and remove it completely. 3. Pull the electrode module out from the tester. 4. Plug in a new electrode module into the tester socket carefully. 5. Replace and tighten the electrode collar to make a good seal. 6. Make sure to calibrate the new electrode before usage. 7 Technical Specifications Model Range Resolution Accuracy P772 Conductivity Meter 0 ~ 19990 µs/cm 10 µs/cm ± 2% F.S. ATC Range 5 C to 50 C Operating 5 C to 50 C

6 Environment Storage Environment Power Expected Battery Life Display 0 to 90% R.H. 0 C to 50 C 0 to 90% R.H. Two 3-V Lithium (CR2032) Batteries 100 hours continuous 3 Digit 21 x 18 mm LCD (.8 x.7 ) Dimensions 33.5 mm x 170 mm (1.3 x 6.7 ) Calibration Weight Housing 1 point manual, via trimmer (span) 85 g (3 oz) ABS IP57 To ensure the most current version of this manual, please download the current version here: http:///images/manuals/p772_manual.pdf For current up-to-date product information, please visit 8 Maintenance This is a precision instrument. To guarantee its performances be sure to use it or keep it stored within the suitable environmental conditions given in the Technical Specifications. Be sure to turn it off after use. To store the instrument for an extended period of time, remove the batteries to avoid any damage to its inner components. 9 Service Information 9.1 Service, Repair, or Calibrations The following are instructions regarding policies for servicing, repairing or calibrating Anaheim Scientific products. Turnaround time is usually less than ten (10) working days unless expedite service is requested and pre-arranged.

7 Send an email to service@ requesting an RMA number specifying your request for either service/repair and/or calibration with your product's model number. Once you receive a reply from service@, you will be asked to ship prepaid to the address below. Package the unit carefully using filler or bubble wrap, and if possible, ship in original box. Ship each unit separately. (Anaheim Scientific is not responsible for any shipping damage that may occur.) Include a packing list with each unit shipped stating what type of service is required and include the return shipping information: name, address and telephone number. If the unit is in warranty, please provide the following: proof of purchase or copy of the original invoice. If the unit is out of warranty, prepayment is required by Check, Money Order or Credit Card. Return all merchandise to Anaheim Scientific with pre-paid shipping. The flat-rate repair charge for Non-Warranty Service does not include return shipping. Return shipping to locations in North American is included for Warranty Service. For overnight shipments and non-north American shipping fees please contact Anaheim Scientific Anaheim Scientific ATTN: Service/Repair 22820 Savi Ranch Parkway Yorba Linda, CA 92887 714-921-9095 9.2 Warranty Limited Two-Year Warranty. Anaheim Scientific warrants to the original purchaser that its products and the component parts thereof, will be free from defects in workmanship and materials for a period of two years from date of purchase. Anaheim Scientific will, without charge, repair or replace, at its option, defective product or component parts. Returned product must be accompanied by proof of the purchase date in the form of a sales receipt. To obtain warranty coverage in the U.S.A., this product must be registered by completing a warranty registration form on within fifteen (15) days of purchase.

8 Exclusions: This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs. The warranty is void if the serial number is altered, defaced or removed. Anaheim Scientific shall not be liable for any consequential damages, including without limitation damages resulting from loss of use. Some states do not allow limitations of incidental or consequential damages. So the above limitation or exclusion may not apply to you. This warranty gives you specific rights and you may have other rights, which vary from state-to-state. Anaheim Scientific 22820 Savi Ranch Parkway Yorba Linda, CA 92887 714-921-9095

(Page intentionally left blank)

(Page intentionally left blank)

22820 Savi Ranch Parkway Yorba Linda, CA 92887 www. 2012 Anaheim Scientific