RVP-R VAV REGULATORS. Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems.

Similar documents
RVP-R- VAV controller. In explosion-proof version

Variable Flow Rate Control Unit

VAV Terminal Units SDS

VAV controller. TROX Auranor Norge AS. Telephone Fax

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

4/S6 VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T. v 2.5 (en)

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

SYSTEM VAV-Controller. for Variable Volume Systems Type VBS

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Mixing Box MBE / MBP

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

VAV TERMINAL BOXES TYPE: BA BT

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Ceiling swirl diffusers

BOX - Airflow management unit BOX. Airflow management unit. Solution. Options & Accessories

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Variable Air Volume Dampers

7/S5 FIRE DAMPER FD40. v 2.9 (en)

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

7 Services Control and monitoring

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

See «Overview of types»

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

volumetric flow controller Model VRA-Q Smart

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

VARYCONTROL VAV Dual Duct Terminal Boxes

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

AIR VOLUME TRANSMITTER / CONTROLLER IML

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Technical Brochure. LTG Air Distribution. Variable flow rate controllers VRFactive. Rectangular, with LTG map control.

Pressure control damper ERPA

3. Dimensions and weights Placement and installation Pressure lost Material... 14

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

Minimum 27 in-lb torque

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Long Throw Nozzle WDA

Laboratory Room Controller

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes

STRA-24 for chilled beams

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Mechanical mixing box MBM

Superstatic 440. Static Heat- and Cooling Meter. Application

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

For installation into ductwork

Silver Series Thermal Dispersion Airflow Measurement Technology

Laboratory Exhaust Air Terminal

CCS Zone/Bypass Damper Assembly

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

SECTION AIR TERMINAL UNITS

Power consumption In operation At rest For wire sizing. Non-operating temperature

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

RETROFIT TERMINAL UNITS

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Acid Resistant AVC6000

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

Versatile and Powerful

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Technical information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

SINGLE DUCT TERMINAL UNITS

Variable Air Volume (VAV) Pressure Independent Control

RECTANGULAR VAV DAMPER TECHNICAL CATALOGUE

Power consumption In operation At rest For wire sizing

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Minimum 27 in-lb Torque

Healthcare Solutions Room Pressure Monitors and Controls

Round Duct System Model RR-Complete

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Transcription:

RVP-R VAV REGUATORS Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems. Intended use VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems. They adjust the amount of supply/exhaust air to control the climate individually for every room/zone served. By using the control elements they can adjust accordingly to different heat gain/loses in the zones served with respect to amount of people gathered in the zone and also other factors such as heat gains and loses through the windows. RVP-R regulators may be produced in two types with respect to the acting time. In the standard version time necessary for the full cycle (open to close) is 150 seconds, while the fast acting drive can do that in 3 seconds. In the special type RVP-R regulators may also be applicable to work with contaminated air with light corrosive gases (according to Classification of Corrosive Environments ISO 12944 max. class C3) Pressure differential value is sent to the controller, where it is transduced to the air volume value and compared with the set point value. If the measured value is different that the set point, the actuator adjusts the air damper to the required position to eliminate the differences between measured and set point values. measuring probes damper blade In the special version, RVP-R regulators are also intended for transporting polluted or slightly aggressive air (according to the Classification of Corrosive Environment in accordance with ISO 12944, maximum class C3). The regulator in accordance with EN1751 has C2 tightness class (tightness of the casing C, tightness of the blade 2) pressure transducer set point value controller damper actuator measured value Material The casing and air damper blade are made of galvanized steel sheet or on special orders it they can be made of stainless steel 1.4306. The damper blade has a rubber gasket, which assures air tightness at the fully closed position. The damper blade shaft is working on plastic or brass bearings. The measuring probe is an orifice or a linear. The orifice is made of galvanized steel sheet. On both sides tube nozzles are installed to measure differential pressure. The linear is made of aluminum profile with proper impulse holes distributed on it. Figure 1. VAV regulator operation. The device is programmed y the manufacturer and the parameters can not be changed by unauthorized people. As an option RVP-R is made with thermal-acoustic insulation RVP-Rt. The control driving mechanism of the air flow regulator is a compact unit consisting of static pressure differential sensor, digital controller PID and the actuator. The working principle depends on measuring air volume flowing through the regulator. In the regulators with orifices reading is made by measuring probes located on both sides of the orifice. In the regulators with linears, reading is made on impulse holes located on both sides of the linear. When the air is flowing through the measuring probe on both sides is created pressure difference which corresponds to the actual air volume. Then the pneumatic signal is transmitted by plastic tubes to the pressure sensor. 329 RVP-R VAV regulators 6.0.0

AIR DISTRIBUTION SYSTEMS SO SN Instalation guidelines c Dn casing blade For the proper performance of the device the following rules should be maintained: keep the straight piece of ductwork on the regulator intake 2D, keep the straight piece of ductwork on the regulator discharge 1D. Electrical wiring of the measuring-control-driving units should be done according to the supplied schematic with the device and it should be done by a professional. measuring flange Figure 2. VAV regulator type: RVP-R. Di Air pressure drop on the RVP-R regulator (air damper blade fully open) The RVP-R regulators underwent analytical tests of the distribution of the measurement elements, aimed at reducing the error threshold of calibration of the regulated air stream, which was reflected in the MA thesis, which was defended in 2005 at the AGH in Krakow. insulation controller 1000 500 Figure 3. VAV regulator type: RVP-Rt (with insulation). Typical dimensions and working range Tabela 1. Typical dimensions and working range of the particular regulator sizes. 100 50 Dn100 Dn125 Dn160 Dn200 Dn250 Dn315 Dn400 Dn500 10 Dn Di c First air stream [m³/h] [only strip] Second air stream [m³/h] [strip or orifice] 100 200 265 365 28-226 55-339 125 225 265 365 44-353 90-530 160 260 280 380 72-579 145-869 Pressure drop [Pa] 1 50 100 Air stream [m 3 /h] 500 1000 5000 10000 200 300 300 400 113-905 225-1357 250 350 350 450 177-1414 350-2121 315 415 415 515 281-2244 560-3367 Chart 1. Air pressure drop on the RVP-R regulator. 400 500 500 600 452-3619 900-5420 500 600 600 700 707-5655 1400-8482 RVP-R VAV regulators 330

Technical data Table 2. Sound power level on the discharge of RVP-R regulator. Sound power level on the discharge of RVP-R regulator WA [db [A] ] 100 [Pa] 250 [Pa] 500 [Pa] 3 6 9 12 3 6 9 12 3 6 9 12 m/s m/s m/s m/s m/s m/s m/s m/s m/s m/s m/s m/s Dn 100 42 50 59 63 55 63 65 70 61 66 70 71 Dn 125 42 49 58 63 55 63 65 69 60 66 70 71 Dn 160 43 53 60 65 54 64 67 72 62 66 71 72 Dn 200 42 52 59 63 55 60 65 71 62 65 70 73 Dn 250 44 55 61 66 55 62 66 72 62 62 70 74 Dn 315 41 56 62 71 57 62 67 75 61 61 73 78 Dn 400 45 54 60 70 58 64 69 75 64 64 75 79 Dn 500 44 56 61 72 58 63 68 73 63 63 74 78 Table 3. Sound power level emitted by RVP-R. Sound power level emitted by RVP-R Regulator without acoustic insulation WA [db [A] ] 100 [Pa] 250 [Pa] 500 [Pa] 3 6 9 12 3 6 9 12 3 6 9 12 m/s m/s m/s m/s m/s m/s m/s m/s m/s m/s m/s m/s Dn 100 24 29 36 43 31 38 43 51 32 39 47 53 Dn 125 24 29 36 43 32 38 43 51 33 39 47 53 Dn 160 24 32 38 45 33 40 44 53 41 44 48 55 Dn 200 25 31 42 48 36 44 47 52 42 46 52 54 Dn 250 30 41 44 49 39 46 47 55 48 51 54 59 Dn 315 33 46 47 53 45 51 53 55 49 56 57 59 Dn 400 36 49 50 53 48 55 56 58 54 56 61 64 Dn 500 35 50 51 53 47 55 57 59 53 55 61 63 Table 4. Sound power level emitted by RVP-R. Sound power level emitted by RVP-R Regulator with acoustic insulation WA [db [A] ] 100 [Pa] 250 [Pa] 500 [Pa] 3 6 9 12 3 6 9 12 3 6 9 12 Control and driving compartment Regulators are produced in two variants: A) Standard performance standard version of RVP-R (for regulation of clean air with full control timing cycle open/close of 150 seconds): VAV Compact In this variant control and driving compartment consists of dynamic differential pressure sensor, controller and damper actuator integrated as one compact unit with: NMV-D3-MP, MV-D3-MP Belimo, GDB 181.1, GB181.1 Siemens, symbols and they are attached to the RVP regulator respectively to its nominal diameters Dn. This unit has the following control sequences possible: control - signal in the range between 2... 10V, 0... 10V - regulator controls the flow of air in the duct between the desired or capacities, Vmin, Vmax, as the continuous signal from the lead in terms of programmed control voltage (0... 10V, 2... 10V), control - fixed signal: Close the air damper fully closed closing the air damper on air supply or air exhaust ducts to unoccupied rooms let to conserve energy. Open - the air damper fully open it is used to help in smoke evacuation from the rooms (heavy ventilating) or quite often as a safe position. V min min. air volume regarding the actual needs or during the unoccupied time particular building zones may be switched to stand by mode and system is providing only minimum required air for ventilation purposes and in such layout it gives additional energy savings. V mid indirect air damper position possible position of the air damper based on mathematical load calculations for the room/zone served. V max max. air volume single room or a group of rooms must temporarily receive maximum air volume this sequence lets to ventilate, evening cooling or morning warm up of the rooms. V nom reference flow for the voltage value returned by the controller (for Vnom, the reverse voltage, on terminals 1-5 is 10V). control through the digital communication protocol: MOD-BUS, EIB Konnex (KNX), BACnet*, MP-BUS**, onworks **, m/s m/s m/s m/s m/s m/s m/s m/s m/s m/s m/s m/s Dn 100 20 23 31 38 29 31 36 41 28 30 36 46 Dn 125 20 23 31 38 30 31 36 41 29 30 36 46 Dn 160 20 25 32 40 30 32 37 44 35 38 39 44 Dn 200 22 25 34 42 29 34 39 42 33 38 40 45 Dn 250 23 30 36 44 37 39 42 47 38 42 44 48 Dn 315 23 35 39 46 40 44 46 49 44 46 47 51 Dn 400 25 39 44 50 43 48 49 50 44 51 53 54 Dn 500 25 40 44 51 44 49 50 52 44 51 54 55 * only Siemens ** only Belimo 331 RVP-R VAV regulators

With relay contacts Connecting via safety isolating transformer working range / function MP/ measuring signal/pp Diagram 1. Diagram of connecting the regulator with a compact actuator NMV-D3- MP or MV-D3-MP. Control function Close Vmin Smooth Vmin..Vmax Vmax Open Diagram 2. Diagram of connection between the regulator and the compact cylinder GDB 181.1 or GB181.1. Table 5. Control and driving compartment. Technical data: MV-D3-MP (NMV-D3-MP) GDB 181.1 (GB181.1.) Nominal voltage 24 V AC/DC, 50/60 Hz 24 V AC/DC, 50/60 Hz suply range 19,2 28,8 V AC 21,6 26,4 V DC Rated power 5 Vamax. 5A@ 5ms [5,5 VA max. 5A@5ms] 3 VA 3 W [3,5 W] 1,25[W] 5,5[VA] 19,2 28,8 V AC 2,5 W 0,5 W 3 VA Torque (nominal torque) 5 Nm [10 Nm] 5 Nm (100m) Direction of rotation Can be selected with 0/1 switch set to ACS Max.95, can be limited at both ends with adjustable mechanical end stops II I [ safety extra - low voltage] Sound power level Maks. 35dB - Casing protection 0 +50[ C] Non-operating temperature range -20 +80[ C] -20 +70[ C] Ambient humidity range 5 95 rh. non-condensating -free 500 g [700 g] 600 g Classic control Tryb z sygnałem wiodącym Mode for actual value signal U5 Operating modes for constant air volume terminal 3-2 10VDC - 0 10VDC terminal 5-2 10VDC - max.05ma - 0 10VDC - max.05ma - Adjustable: volumetric flow YC 2-10VDC 0-10VDC U 2-10VDC COSE / Vmin / Vmid / Vmax / OPEN (only with AC 24V supply) MP-BUS function Address in bus operation MP 1 8 / classic control: PP - onworks /EIB Konnex With BEIMO UK24ON / UK24EIB interface, 1 8 BEIMP MP devices DDC controller DDC Controller / PC, with integrated MP interface - Fan optimiser Optimiser Belimo COU24-A-MP - - By pressing a button on the actuator casing, it is possible to disengage the transmission. As long as the button is pressed, it is possible to manually change the throttle. RVP-R VAV regulators 332

B) Special enforcement quick version of RVP-R (with full control timing cycle open/close of 3 seconds) applicable for use in environments with light chemical contaminations Control driving compartment of the vav regulator is the Belimo device which consists of static pressure differential sensor, digital controller PID VAV and actuator. In the control and driving compartment there are the following items: 1.Controller PID VAV with the following options control: control - signal in the range between 2 10V, 0 10V, control - fixed signal : Close, Open, Vmin, Vmid, Vmax, control through the digital communication protocol possibility to integrate with: systemami EIB Konnex KNX (UK-24EIB), systemami onworks (UK-24ON), systemami BACnet (UK-24BAC), systemami MOD-BUS (UK-24MOD), Fan optimiser systems. 2. Static pressure differentia sensor is applicable for pressure differential readings in air ducts or in rooms. They are adapted to work with contaminated air with light chemical aggressive gases. Solid design makes them available for use in laboratories, GMP rooms and in the industry. Table 6. Type Reading ranges Protection against high presures Temperature dependance VFP-300 0 300[Pa] Maks. 5000[Pa] ±0,05%/K Approx. 280g Table 8. Actuator MQ24A-SRV-ST 4[Nm] - application for fast acting devices. Technical data: Nominal voltage Torque (nominal torque) Direction of rotation Running time Degree of protection Sound power level Non-operating temperature range 24[V] AC/DC [from VRP- controller] 12[W] 1,5[W] 18[Va] Min. 4[Nm] at nominal voltage Can be selected with 0/1 switch Max.95, can be limited at both ends with adjustable mechanical end stops III [safety extra - low voltage] 2,5[s]/90 52[dB] [A] -30 +50[ C] -40 +80[ C] -free 146/80/75 810[g] Table 9. Actuator NMQ24A-SRV-ST 8[Nm] - application for fast acting devices. Technical data: Nominal voltage 24[V] AC/DC (from VRP- controller) 12[W] 1,5[W] 18[Va] 3.Actuator NM24A-V-ST 10[Nm] - standard application Table 7. Technical data: Torque (nominal torque) Direction of rotation Min. 8[Nm] at nominal voltage Can be selected with 0/1 switch Max.95, can be limited at both ends with adjustable mechanical end stops III (safety extra - low voltage) Nominal voltage 24[V] AC/DC (from VRP- controller] Running time 4[s]/90 Torque (nominal torque) Direction of rotation 3,5[W] 1,25[W] 5,5[Va] Min. 10[Nm] at nominal voltage Can be selected with 0/1 switch Degree of protection Sound power level Non-operating temperature range 52[dB] [A] -30 +50[ C] -40 +80[ C] Running time Max.95, can be limited at both ends with Adjustable mechanical end stops 150[s] III [safety extra - low voltage] -free 156/88/77 930[g] Sound power level Max. 35 [db] Degree of protection Non-operating temperature range -30 +50[ C] -40 +80[ C] -free 146/80/75 710[g] Any orders regarding regulators with fast acting drives must be discussed with and accepted by Smay technical department. The control and driving compartment is all connected by the manufacturer, but the customer must bring the power supply and do the control wiring himself. Electrical wiring of the VRP-M unit should be done according to the supplied schematic and it should be done by a professional. 333 RVP-R VAV regulators

Supply via safety isolation tranfsormer! Connection 1, 2 (AC/DC 24V) and 5 (MP signal) must be routed to accessible terminals (room temperature controller, floor distribution, control cabinet, etc.) in order to simplify access with the PC-Tool for diagnostic and service work. VAV with analogue reference signal reference value input w 0... 10 / 2... 10 / adjustable PP/MP communication volume flow actual value U5 0... 10 / 2... 10 / adjustable control input z Override control Function Close Open V min V max V mid Connection 1 7 2 6 2 7 2 7 2 7 Diagram 3. Connection diagram of the regulator with fast automatic control (VRP-M). RVP-R - Regulator przepływu VAV While ordering please provide information according to the following method: <RVP-P> <X> - <I> - <A> x <B> - <V MAX > / <Za> <V MIN > <Ta> - <Ts> - <Tp> - <K> - <N> - <S> - <P> Where: X measuring element* Tp connection type* - flange - clasic - measuring strip MST - Master/Slave communication with function Master I insulation* SV - Master/Slave funkcja Slave - not insulated K communication* t - insulated - 2...10V (with the option to force the COSE position) A inner width of the regulator 1-0...10V B Inner height of theregulator MP - general value MP BUS (only Belimo) V MAX max. air volume [m³/h] MOD - Modbus Za Does the controller (regulator) have the full closure feature?* ON - onworks (only Belimo) - no KNX - KNX (0) - Yes (closing option available) BAC - BACnet (only Siemens) V MIN Ta Ts min. air volume [m³/h] the type of automation* - Standard (Belimo) Sim - Siemens the type of drive* - standard Q - quick (only Belimo) N S P number of the regulator in the system - applies only for MP-BUS communication environment* C3 material* SO SN - clean air - environment with class C3 - galvanised steel - stainless steel *optional values - default values will be used if optional values are not specified Order example: RVP-Rt-315-1100/700-Q-MP BUS-7 RVP-R VAV regulators 334