INSTALLATION and OPERATING INSTRUCTIONS

Similar documents
AGILENT VACUUM VALVEs

Mini UHV gate valve with manual actuator with pneumatic actuator

All-metal angle valve Series 57

AGILENT VACUUM VALVES

ANGLE/INLINE VALVE WITH SOFT-PUMP FUNCTION, SERIES 29.0/29.2

Differentially Pumped Rotary Platform (DPRP) Instructions

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

HV Gate Valve with pneumatic actuator

Serie 2003/2013. Three-way Control Valve, mixing/diverting. Wörth am Main. Service. Control Valve Division

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

UHV Angle valve (Series 284) with pneumatic actuator, single acting with closing spring (NC)

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½" - 4") Hot surfaces; do not touch!

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 )

Operating Instructions. Angle Seat Control Valve. Type 7020

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

Series Single seated top guided control valve. Preventive maintenance. Overhauling procedure. Wörth am Main SERVICE NOTE. Control Valve Division

Installation, Operation, and Maintenance Manual

DA Series Diaphragm Valve

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES

Agilent Aluminum Block Valves - Series 26 NW 16 - NW 40 ISO-KF Flange

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator

Pressure chlorine changeover unit C 7520

Rectangular Door L-VAT with pneumatic actuator double acting

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM

Operating & Maintenance Manual For Steam Conditioning Valve

EC4 SERIES CRYOGENIC VALVES 1/4 2 Sizes

IOM Manual. IOM Manual. Series 20/21.

ACTO 400 to MAINTENANCE

Fig.01 Fig.02 Fig.03. Disassembly & Reassembly Instructions SBV-HP - Page 3

aero 2 -IOM aero 2 ACTUATOR - INSTALLATION, OPERATION & MAINTENANCE MANUAL

Installation, Operation, and Maintenance Manual

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Pressure Reducing Valve V782

HV Angle valve (Series 264) HV Inline valve (Series 265) with pneumatic actuator, single acting with closing spring (NC)

Typical Feed Water Heater Isolation System.

Industrial flue gas probes. Instruction manual

Pendulum valve Series 16

Danfoss Butterfly Valve

All-metal gate valve Series 48

Micro Diaphragm Gas Sampling Pumps

ARKAL SCREEN LINE H - SERIES Hydraulically Operated Self-Cleaning Screen Filter SERVICE & MAINTENANCE MANUAL

Operating Instructions

for ½" thru 2" 800 lb. Piston Lift Check Valves with Resilient Seat Option

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

DL/DS Series Diaphragm Valve

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

Flow Line Controls. Installation & Operations Manual SERIES 20/21 Pneumatic Actuators

HV gate valve Series 11

Installation, Operating & Maintenance Instructions

Operating manual Separator

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline EC & EK Series Characterized Control Valves Sizes 1/2 6

LOCKED SERIES. Machine Failures. General Information. set up. maintenance. reconditioning. repair 30.4%

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

OM Corrosion-Resistant Teflon Control Valve Model : HIT User's Manual

Venting valves. Valves. Manually actuated. Venting valves. Installation elements

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Disassembly / Reassembly Procedure

TECHNICAL MANUAL MT029

HV angle valve with single acting pneumatic actuator and closing spring (NC)

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Installation, Operation and Maintenance Manual for the HE Series

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

G = basic version A = with SPS H = with PFO C = with SPS and PFO. Ordering number example:

Pendulum valve control system Series 65

Instructions for installation, operation and maintenance of: GATE VALVE

Fisher 585C Series Piston Actuators

Combined Ventilation Controller RVWS-T-224HA

Installation Instructions. Standard Gate Valves

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Mounting and operating instructions EB 8093 EN. Series 240 Pneumatic Control Valve for Cryogenic Temperatures. Type and

UHV gate valve Series 10

Mounting Instructions Welded Coupling Mounting Instructions Welded Coupling

Throttling Pendulum Gate O-ring Replacement Procedure Rev. A, May 2012

F8/FB8 Series Ball Valves IOM-F8/FB8

Types 472, 473, 3572, 3573

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

Installation, Operation, and Maintenance Manual

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

HV-Angle Valve (Series 264) HV-InlineValve (Series 265) with electromagnetic actuator single acting with closing spring (NC)

Industrial Turbo Meters, Sizes 2" through 6"

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA

I & M Mark 708. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & 14M Actuator and Motor Valve

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

B21 Series BASOTROL Gas Valve

HPS Two-Stage Vacuum Valve Instruction Manual Addendum - Bypass Valve Service

DM-TRSL (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike. Shifting lever DEORE XT SL-T8000 DEORE SL-T6000

PF6 Stainless Steel Piston Actuated On/ Off Valves

USER INSTRUCTIONS. Kämmer SmallFlow - Series / Low and Micro Flow Valves. Installation Operation Maintenance. Experience In Motion

Installation, Operation And Maintenance Manual. Manual. For the 400 Series. ABZolute Seal. High Performance Butterfly Valve "Double Offset"

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Vacuum Valves. Manually Operated Electropneumatically Operated Electromagnetically Operated Special Valves Gate Valves

Miniature Shock Absorbers SC²25 to SC²650 Self-Compensating

Transcription:

INSTALLATION and OPERATING INSTRUCTIONS UHV-LEAKVALVE ND 3 pneumatically operated NC, 2-positions cylinder. Valve F3CF1616-29 Valve F3CF3516-29 Valve F3VCR-29 Heating Cartridge HF3 Heater Controller HF3-S1 Version: A LIST of CONTENTS: Page 1. APPLICATION 2 2. DESCRIPTION 2 3. TECHNICAL DATA 2-3 4. CONNECTION 3 4.1 Cleanliness 3 4.2 Mounting position 4 4.3 Admissible forces 4 4.4 Operation 4 5. PUTTING INTO OPERATION 4 6. MAINTENANCE 4 7. SERVICE and REPAIRS 4 7.1 General 4 7.2 Dismantling of the actuator 4-5 7.2 Dismantling of the housing 5 8. SPAREPARTS 5 9. WARRANTY 5 10. ACCESSORIES 5 10.1 Heating Cartridge 5-6 10.2 Heater Controller 6 10.2.1 Connection 6 10.2.2 Programming 6 10.2.3 Display 6-7 10.2.4 Start heating 7 10.2.5 End heating 7 10.2.6 Error messages 7 Page 1

1. APPLICATION The UHV-Leakvalve is both a shut-off device and a control valve to control a gasflow. It covers a wide range of controlability and can be baked, thanks to the used all-metal technology. The valve is available manually operated and stepper motor driven with Controller. In the present case it is pneumatically operated with closing spring and with an adjustable stop for the open position. 2. DESCRIPTION The housing and all parts in touch with the medium are made of stainless steel. The plate gasket and the bonnet gasket are one piece and made of stainless steel, gold plated. The tightening between the valve rod and the inner volume is done through a diaphragm made of metal. A pneumatic cylinder operates the valve, which is assembled to the valve by using a teflon part for thermic isolation. It is important to keep the temperatures of the actuator under 120 C, and of the solenoid valve under 80 C. The adjustable open position can be fixed over the whole control range. If there is a distance of 1mm between the screwhead (hexagon 24mm) and the cylinder cap (flat surface), the closed position is adjusted. If this gap is 9mm or more, the full open position is adjusted. The nominal stroke of this screw is 8mm = 4 full turns. This screw is self-locking. The actuator is greased for life. If the cylinder should be disassembled for any reason, a simple tool is necessary. Ask us, we will provide you with the necessary dimensions. This simple tool is a screw M8 in the right length and a washer. 3. TECHNICAL DATA Pressure range 1 x 10-10 mbar to 10 bar Leakrate: Housing 1.10-10 mbar.l/s Valve plate 1.10-10 mbar.l/s Differential pressure at the valve plate Leakrate: 10 bar in both directions In the range of turn 0-3, the -0 10 diaphragm doesnot touch the valve seat, therefore there is no 10-3 hysteresis. Due to physical reasons, the valve cannot control 10-6 the range between 10-8 and 10-10, if the valve is used in cold 10-9 conditions. In that case, the valve 0 20 40 60 80 100% is tight from turn 8 to 10. Mounting position any. Valves with VCR-connectors have an 1 printed on the valve seat side. Temperatures: Housing 300 C in control positions, 450 C in open position Actuator 120 C Solenoid valve 80 C Weight CF-16/16, VCR 10,1 kg CF-35/16 10,8 kg Screw for adjustment: Number of turns Lifetime until first service 4 (gives 8mm stroke) 100.000 cycles Materials: Housing 316L Diaphragm 316L gold plated Mechanism (not in touch with medium) 304, steel hardened and protected Gaskets in the actuator Viton Page 2

Dead volume: Main flange (down) 1,0 and 1,4 ccm (CF-16 and CF-35) Side flange 4,6 ccm Actuation principle of the pneumatic cylinder: Necessary compressed air pressure Voltage of the solenoid valve Power consumption of the solenoid valve NC min. 4 bar overpressure, max. 9 bar overpressure. 24VDC 4,5 W Dimensions: CF-16 rotatable flanges on both sides: CF-16 rotatable on the side port and CF-35 rotatable on the main port: 4. ANSCHLUSS VCR-connectors 3/4 : 4. CONNECTION 4.1 Cleanliness. The valve may only be unpacked immediately before the valve is installed into the system. Sealing surfaces on the flanges, and also the valve interior may only be touched with clean gloves. The valve may only be installed in clean systems. Page 3

4.2 Mounting position. These valves may be mounted in aly position.. The valve with VCR-connections has an 1 printed on the valve seat side. 4.3 Admissible forces. The valve must not be used to support other heavy components. Install bellows elements in the piping to ensure that no additional forces, either during bakeout or by heavy weights of other components of the installation, or by vibrations, can effect the valve. 4.4 Operation. The valve operaties by the already installed solenoid valve (24VDC). There is an emergency override (red button with slot) which can be actuated by using of a screwdriver. Doing that, compressed air must be present. CAUTION: This emergency button must be brought back to its starting point, otherwise the solenoid valve will not work in the normal working condition with the 24V. The adjustable open position can be fixed over the whole control range. If there is a distance of 1mm between the screwhead (hexagon 24mm) and the cylinder cap (flat surface), the closed position is adjusted. If this gap is 9mm or more, the full open position is adjusted. The nominal stroke of this screw is 8mm = 4 full turns. Any position between these two endpositions are possible. This screw must not be adjusted if the actuator is actuated by compressed air (piston presses then strongly against this screw) Thanks to the used thread Heli-Coil Mid-Grip, this screw is self-locking. Therefore it is not necessary to fix it with other methods. If this adjusting screw is screwed down by mistake strongly against the internal stop (gap 1mm), the control courve of the valve might be influenced. To eliminate this influence, it is enough to move once into the fully open position, and the well-known leakrates will be reached again. 5. PUTTING INTO OPERATION After installing of the valve according to this manual it is ready to operate. The valve is shipped in closed position. To be sure about the tightness of the vacuum system, we recommend to check the whole valve and the flanges about their helium tightness. 6. MAINTENANCE If the valve us used under clean conditions, it works maintenance-free during the lifetime stated in the technical data. If a valve will be sent back to the factory, it must be free from toxicant and noxious matters. Where applicable, it must undergo a decontamination prior to return. A certificate which confirms the harmless and safety must be added to the shipment. 7. SERVICE and REPAIRS 7.1 General. During service works the following items must be observed: All works must be done under clean conditions. Sealing surfaces must be protected. Use only original spare parts. 7.2 Dismantling of the actuator. The pneumatic cylinder is an unit and can be removed completely. It is recommended to put the valve into the open position, because otherwise the force of the inner springs will enforce the four M6 screws which connects the actuator with the valve. This force can be up to 4500N. Then, these four M6 screws which connects the actuator with the valve can be removed. Then the whole actuator can be removed. Now the compressed air can be released from the pneumatic cylinder. The rod does its stroke of 8mm out of the cylinder. Page 4

Then, two screws M5 x 50 are visible inside (towards the valve body), they connect the valve body with the connection flange. These two screws can be opened and removed, as well as the connection flange. A packing of spring disks is then accessible, which can be newly greased if requested. Use only temperature resistant grease. The stamp Item 03 in the center can be removed together with the springs. Then, the diaphragm (gold plated) will be visible. At reassembling please pay attention that no dust or dirt or particles are placed on the diaphragm or on the stamp Item 03, because this can influence the tightness heavily. Greases on this surface are not necessary but allowed (because this side is not in touch with vacuum). CAUTION; The package of spring disks is individually adjusted and selected. It must not be mixed up (sequence of the springs) or otherwise modified. 02 01 7.3 Dismantling of the housing. ATTENTION: From this step on, the medium touched inner parts will be uncovered. Depending on the used medium, it will be released to outside and it must be ensured that absolute no toxicant or noxious materials are left in the valve. Loose and remove the four screws 04. Now the upper part of the housing, and then the diaphragm can be removed. The diaphragm is used both as valve plate and as bonnet gasket. Damages or scratches on the sealing surfaces requests new machining of the parts! Before assembling, the parts must be cleaned carefully. In the vacuum-area no grease or oil must be used! 04 03 8. SPARE PARTS. Diaphragm 15301 Housing CF 16/16 15421 Housing CF 35/16 15424 Housing VCR 15614 The diaphragm cannot be damaged by normal use. Only through improper use like crystal-growing of the used gases, other solid parts in the medium, chemical reactions between the used medium and the gold layer, or mechanical damage during a repair can damage the diaphragm. 9. WARRANTY These valves are assembled under clean conditions. Each valve is tested for optimum performance and leak tightness. Installation into customers vacuum system must be done under clean conditions. Installation and operating instructions must be adhered to according to this manual. Faulty installation, inappropriate operation or modifications of the valve will annul our warranty. We guarantee a warranty period of 12 months from the date of arrival at the customer. In case of rightly claimed complaints or defects we replace or we repair the goods, according to our own deciding. Replacing of the goods requires always the return of the complainted goods. There is no warranty for subsequent damages. On demand, services or repairs will be carried-out through us. Goods sent back to the factory, irrespective of the reason (service, repair, replacement due to warranties) must be free from toxicant and noxious matters. Where applicable, it must undergo a decontamination prior to return. A certificate which confirms the harmless and safety must be added to the shipment. 10. ACCESSORIES 10.1 Heating cartridge. A high performance heating cartridge ø8 x 35mm with an integrated thermoelement is used. Page 5

Power: 800W / 230VAC Material: Incoloy 800 Max. temperature: 800 C The heating cartridge fits in the boring ø8mm on the housing, and must be secured slightly with the set screw. To avoid damage of the heating cartridge, this set screw must not be hardly tightened. The valve cannot reach the requested temperature (over 100 C), if the valve is not insulated. After installing of the valve and the heating Cartridge we recommend to put an approximately 20mm thick insulating material over the valve body and its connection flanges. The connection tube between valve body and pneumatic cylinder must not be insulated. Otherwise the temperatures in the cylinder might become too high. 10.2. Heater controller. The heater controller from WATLOW is adjusted to the heating cartridge and the valve. The adjustable parameters like heatingand cooling ratio are pre-adjusted in our works. 10.2.1. Connection: 230VAC Thermoelement + (red) - (green) Heating Cartridge 10.2.2. Programming: To enter into the setup-menue, press the arrow keys up and down together for min. 3 seconds. If no key is pressed for a time of approx. 60 seconds, the setup-menue will be closed automatically. Go through the setup-menue with the green turn - key. The different setup-positions are: LOC In C F rl rh Ot 1 HSC Ot 2 rp rt P L dsp Factory setting: 0. All parameters can be seen and adjusted. Factory setting: H. Thermoelement type. We use type K which is adjusted as H. Factory setting: C. Celsius. Factory setting: -200. No adjustment necessary. Factory setting: 450. This is the maximum possible temperature. Factory setting: ht. No adjustment necessary. Factory setting: 2. Hysteresis-control. No adjustment necessary. Factory setting: no. No adjustment necessary. Factory setting: Str. This is the adjustment of the ramp in C/h. Factory setting: 180. This is the rapm in C/h, if rp was set on Str. Factory setting: 100. No adjustment necessary. Factory setting: nor. Display normal. 10.2.3. Display: Upper 7-segments line red: Below 7-segments line green: LED 1: Actual temperature in C at the thermoelement. rp interchanges with a number: Initializing is running (for approx. 45 sec). Number: Adjusted temperature in C. Heating runs. LED 2: Spare: Heat circuit 2. Page 6

%: If this LED is on, the controller is in the manual-mode. Press infinity-key twice to shut-up this LED and to put the controller in the automatic-mode. Turn-key green: Arrow key up: Arrow key down: Infinity-key: Go through the setup program. Go through the adjustments, upwards. Go through the adjustments, downwards. Press twice, to put the controller in the automatic mode. Press once to switch-off a possible alarm-led. If this key is pressed in the standard menue, the advanced-menue starts. In this advancedmenue a fine tuning can be adjusted. We recommend to leave this menue. 10.2.4. Start heating. Press arrow key up, until the requested temperature is in the green display. Heating starts immediately after release. The LED 1 flashes, when the heating cartridge is under currency. Due to the adjusted ramp the LED 1 flashes not permanently, but every 10 seconds. The ramp is adjusted to 180 C/h. 10.2.5. End heating. Press arrow kay down, until a temperature of i.e. 20 C is in the green display. Cooling starts immediately after release. The LED 1 flashes from time to time, if the cooling-down would be faster than the adjusted ramp. The ramp is adjusted to 180 C/h. After reach of under 100 C (red display) the currency can be switched off. 10.2.6. Error messages: In the upper display appears 4 lines, in the below display appears is Er X. Er 2 Er 4 Er 5 Er 6 Er 7 Thermoelement notifies a temperature under the allowed range (-200 450 C), or the controller has a mistake (analog/digital-conversion). Failure of the microprocessor. Send back for repair. Testsum error. Possibly the currency was interrupted while the processor was under calculation. Analog/digital-conversion mistaken: Underflow. Possibly the polarity is wrong connected, or the circuit is cutted. Analog/digital-conversion mistaken: Overflow. Possibly the polarity is wrong connected. To delate an error message: Switch-off the controller (cut the power input), and switch-on again. If requested, a detailed manual from the manufacturer of the controller can be sent. This manual contains all different delivery versions and needs very exactly analizing and adjustment. Page 7