Product Submittals for Project May 011-1
Couplings Figure 577 Light Weight Rigid Coupling For Fire Protection Pressure Rating and Listing / Approval information contact Tyco Fire Suppression & Building Products. Ductile Iron Housing Specifications ASTM A-536 Standard Specification for Ductile Iron Casting Grade 65-45-1 Tensile Strength, minimum psi 65,000 (448 MPa) Yield Strength, minimum psi 45,000 (310 MPa) Elongation in (50mm), minimum 1% ASTM A-153 Standard Specification for Hot Dip Galvanizing Bolt/Nut Specifications Carbon steel oval neck bolts and nuts are heat treated and conform to the physical properties of ASTM A-183 with a minimum tensile strength of 110,000 psi (760 MPa). Bolts and nuts are zinc electroplated to ASTM B-633. Metric - conforming to ASTM F-568M Coatings Orange Non-Lead (Standard) Fire Brigade Red Non-Lead (Optional) Hot Dipped Zinc Galvanized (Optional) Gasket Specifications Grade A EPDMA, violet color code ambient to +150 F (+66 C) for fire protection systems. Not recommended for hot water systems. Tri-seal (Grade E EPDM), green color code for use in dry pipe or freezer systems. Prelubricated (Grade A EPDMA) Project: Date: Architect / Engineer: Contractor: Address: Notes: May 011-45 Project Information: Phone: Technical Data Sheet: TFP1854 Date: March 011 Approval Stamp: Page 1 of
Couplings Figure 577 Light Weight Rigid Coupling (cont.) B C A FIGURE 577 GROOVED RIGID COUPLING 1-1 (DN5 TO DN) Nominal ANSI DN 1 DN5 1-1/4 DN3 1-1/ DN40 DN50-1/ DN65 DN65 3 DN80 4 DN100 DN15 5 DN15 DN150 6 DN150 8 DN00 10 DN50 1 DN Pipe Size O.D. 1.315 (33,4) 1.660 (4,) 1.900 (48,3).375 (60,3).875 (73,0) 3.000 (76,) 3.500 (88,9) 4.500 (114,3) 5.500 (139,7) 5.563 (141,3) 6.500 (165,1) 6.65 (168,3) 8.65 (19,1) 10.750 (73,1) 0 (33,9) Max. Pressures psi (bar) (4,1) (4,1) (4,1) (4,1) (4,1) (4,1) (4,1) (0,7) (0,7) (0,7) (0,7) (0,7) (0,7) 175 (1,1) 175 (1,1) Max. End Load Lbs. (kn) 475 (,11) 757 (3,37) 99 (4,41) 1,551 (6,90),7 (10,11),474 (11,01) 3,367 (14,98) 4,771 (1,) 7,17 (31,71) 7,90 (3,43) 9,955 (44,8) 10,341 (46.00) 17,58 (77,97) 15,883 (70,7),343 (99,4) Max. * End Gap 0.15 (3,) 0.15 (3,) 0.15 (3,) 0.15 (3,) 0.15 (3,) 0.5 (6,4) 0.5 (6,4) Nominal Dimensions A 1.63 ().66 (68).90 (74) 3.38 (86) 3.88 (99) 4.00 (10) 4.50 (114) 5.70 (145) 6.80 (173) 6.86 (174) 7.80 (198) 8.47 (15) 10.5 (60) 1.50 (318) 14.50 (368) B 3.9 (100) 4.40 (11) 4.66 (118) 5.0 (13) 5.64 (143) 5.78 (147) 6.33 (161) 7.50 (191) 8.75 () 8.8 (4) 9.75 (48) 9.88 (51) 1.78 (35) 16.50 (419) 18.50 (470) C 1.65 (4) 1.64 (4) 1.66 (4) 1.70 (43) (44) () (44) 1.83 (46).40 (61).56 (65).56 (65) Qty. Coupling Bolts Size** 3/8 x -1/4 3/8 x -1/4 3/8 x -1/4 3/8 x -1/4 3/8 x -1/4 3/8 x -1/4 3/8 x -1/4 M1 x 76 1/ x 3 M1 x 76 M1 x 76 1/ x 3 M1 x 76 5/8 x 3-1/4 3/4 x 4-3/4 M0 x 11 3/4 x 4-3/4 M0 x 11 Approx. Weight Lbs. (kg) 1. (0,55) 1.3 (0,59) 1.5 (0,68) 1.8 (0,8).0 (0,91).0 (0,91) 3.3 (1,50) 3.3 (1,50) 5.3 (,41) 5.3 (,41) 5.7 (,59) 5.9 (,68) 11.7 (5,3) 19.5 (8,86).0 (10,00) * Maximum available gap between pipe ends. Minimum gap = 0. Maximum Pressure and End Load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ for other pipe materials and/or wall thickness. Contact your GRINNELL Representative. ** Gold color coded metric bolt sizes for DN5 - DN couplings are available upon request. Max End Gap is for cut grooved standard weight pipe. May 011-46 Page of
COUPLINGS Figure 705 Flexible Coupling For Fire Protection Pressure Rating and Listing / Approval information contact Tyco Fire Suppression & Building Products. Ductile Iron Housing Specifications ASTM A-536 Standard Specification for Ductile Iron Casting Grade 65-45-1 Tensile Strength, minimum psi 65,000 (448 MPa) Yield Strength, minimum psi 45,000 (310 MPa) Elongation in (50mm), minimum 1% ASTM A-153 Standard Specification for Hot-Dip Galvanizing Bolt/Nut Specifications Carbon steel oval neck bolts and nuts are heat treated and conform to the physical properties of ASTM A-183 with a minimum tensile strength of 110,000 psi (760 MPa). Bolts and nuts are zinc electroplated to ASTM B-633. Coatings Orange Non-Lead (Standard) Fire Brigade Red Non-Lead (Optional) Hot-Dipped Zinc Galvanized (Optional) Gasket Specifications Grade A EPDMA, violet color code ambient to +150 F (+66 C) for fire protection systems. Not recommended for hot water systems. Tri-seal (Grade E EPDM), green color code for use in dry pipe or freezer systems. Prelubricated (Grade A EPDMA) Project: Date: Architect / Engineer: Contractor: Address: Notes: May 010-3 PROJECT INFORMATION: Phone: Technical Data Sheet: TFP180 Date: July 004 APPROVAL STAMP: Page 1 of
COUPLINGS Figure 705 Flexible Coupling (cont.) Pipe Max. * Max. Max. Nominal Dimensions Deflection Net Bolt O.D. End Gap Pressure End load A B C / Wt. Per Size** Size Psi Lbs. Foot Lbs. Coupling Dia. x Lg. mm mm kpa N mm mm mm mm/m kg 1.660 0.13 649.56 4.19 1.81 0.90 3 /8" x 1 /4" 1.5 1 1 4" 4-19' 4.4 3.3,068,887 65.0 106.4 46.0 75.0 0.7 1.900 0.13 850.75 4.44 1.81 0.79 3 /8" x 1 /4" 1.6 1 1 " 3-46' 48.3 3.3,068 3,781 69.9 11.8 46.0 65.8 0.7.375 0.13 1,38 3.5 4.88 1.88 0.63 3 /8" x 1 /4" 1.7 " 3-1' 60.3 3.3,068 5,907 8.6 14.0 47.8 5.5 0.8.875 0.13 1,947 3.69 5.50 1.88 0.5 3 /8" x 1 /4".0 1 " - 9' 73.0 3.3,068 8,660 93.7 139.7 47.8 43.3 0.9 3.000 0.13,10 4.00 5.75 1.88 0.50 3.1 76.1mm - 3' M1 x 76 76.1 3.3,068 9,430 101.6 146.1 47.8 41.7 1.4 3.500 0.13,885 4.38 6.50 1.88 0.43 1 /" x 3" 3.0 3" - 3' 88.9 3.3,068 1,83 111.3 165.1 47.8 35.8 M1 x 76 1.4 4.50 0.5 4,56 5.50 7.50.06 0.70 4. 108.0mm 3 - ' M1 x 76 108.0 6.4,068 18,931 139.7 190.5 5.3 58.3 1.9 4.500 0.5 4,769 5.69 7.75.06 0.67 1 /" x 3" 4.0 4" 3-11' 114.3 6.4,068 1,13 144.5 196.9 5.3 55.8 M1 x 76 1.8 5.50 0.5 6,494 6.56 9.50.06 0.56 7. 133.0mm - 44' 133.0 6.4,068 8,885 166.6 41.3 5.3 46.7 3.3 5.500 0.5 7,17 6.81 9.75.06 0.56 7. 139.7mm - 36' 139.7 6.4,068 31,701 173.0 47.7 5.3 46.7 3.3 5.563 0.5 7,88 6.88 9.75.06 0.54 5 /8" x 3 1 /4" 7.0 5" - 35' 141.3 6.4,068 3,417 174.8 47.7 5.3 45.0 3. 6.50 0.5 9,04 7.56 10.31.06 0.48 7.4 159.0mm - 17' 159.0 6.4,068 40,939 19.0 61.9 5.3 40.0 3.4 6.500 0.5 9,950 7.75 10.69.06 0.46 7.1 165.1mm - 1' 165.1 6.4,068 44,58 196.9 71.5 5.3 38.3 3. 6.65 0.5 10,336 7.94 10.69.06 0.45 5 /8" x 3 1 /4" 7.1 6" - 10' 168.3 6.4,068 45,975 01.7 71.5 5.3 37.5 3. 8.500 0.5 17,04 10.07 13.50.31 0.35 1.4 16.3mm 1-40' M0 x 11 16.3 6.4,068 75,73 55.8 34.9 58.7 9. 5.6 8.65 0.5 17,519 10.19 13.56.50 0.35 3 /4" x 4 3 /4" 14.5 8" 1-40' 19.1 6.4,068 77,95 58.8 344.4 63.5 9. M0 x 11 6.6 10.750 0.5 50,679 1.69 16.38.63 0.8 1" x 6 1 /" 8.0 10" 1-0' 73.0 6.4 1,74 100,876 3.3 416.1 66.8 3.3 M4 x 165 1.7 0 0.5 50 31,903 14.94 18.88.63 0.3 1" x 6 1 /" 36.5 1" 1-7' 33.9 6.4 1,74 141,905 379.5 479.6 66.8 19. M4 x 165 16.6 * Maximum available gap between pipe ends. Minimum gap = 0. Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Suppression & Building Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. ** Gold color coded metric bolt sizes are available upon request. Max End Gap and Deflection is for cut grooved standard weight pipe. Values for roll grooved pipe will be half that of cut grooved. May 010-4 Page of