Product Submittals for Project

Similar documents
Couplings. Ductile Iron Housing Specifications. Coatings. Gasket Specifications. Bolt/Nut Specifications

The applicable material specifications for ductile iron and rubber gaskets apply:

Mechanical MATERIAL SPECIFICATIONS. Stainless Steel Housing Specifications. Gasket Specifications. Bolt / Nut Specifications

Grooved Piping Products

FIG Gruvlok Flange Adapter

B U I L D I N G C O N N E C T I O N S T H AT L A S T

FIRE SPRINKLER EQUIPMENT SUBMITTAL

FIG Gruvlok Flanges

Grooved Fire Protection. Installation Handbook

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

Style Flange Adapter

030/TL 03/01 50M, Copyright 2001, Anvil International $3. 50

COOPLOK Grooved Submittal. Material Specifications

Housing Coating: Orange enamel. Hot dipped galvanized. Optional Bolts/Nuts: (Available in imperial size bolts and nuts only.)

GROOVED COUPLINGS - STANDARD FLEXIBLE Model 101

QuickVic Rigid Coupling for Steel. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE GROOVED COUPLINGS

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Grinnell Grooved Fire Protection Products Grooved Fittings

Style 99 Roust-A-Bout Couplings

Hot dipped galvanized. Optional Bolts/Nuts: (Available in imperial size bolts and nuts only.)

Victaulic Suction Vibration Isolation Pump Drop Series 337 Korea Only

Model 7706 Reducing Coupling. Deg. Axial Displacement

GRINNELL Model B303 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Grooved Piping System for Fire Protection Services

Size Inches UL ULC FM. Pipe Sch.

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Hole-cutting. cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16mm) of the hole

Grooved Piping System for Fire Protection Services

Ford Fabricated Steel Products

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Style 234 Restrained Flexible Single-Gasket Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date

Victaulic Standard Grooved and Advanced Grooved (AGS) Piping System for IPS Steel 2 (DN 50) through 60 (DN1500)

Vic-Strainer WARNING. System No. Submitted By Spec Sect Para Location Date Approved Date IPS CARBON STEEL PIPE - GROOVED ACCESSORIES SERIES 730

UNITED BRAND FITTINGS

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

JIS G (SGP)

Victaulic Specification Power Industry

with the specific application. Always read and understand the installation

EMCO Corporation Waterworks is not responsible for any errors and discrepencies in the products depicted herein. Information is provided directly

GRUVLOK FITTINGS FOR GROOVED-END PIPE

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

Steel Fabricated Coupling

Presby Steel, LLC. 143 East Milan Road Berlin, NH FAX:

Section 2. Shurjoint Grooved Fittings Flow Data / Friction Resistance Ductile Iron Grooved Fittings. Wrought Grooved Fittings

' ' ' ' LISTED Elbows Tees Crosses Wyes Reducers Flanges Converters Gaskets Nuts&Bolts

UNITED BRAND FITTINGS

STAINLESS STEEL SYSTEMS

Advantages of Grooved Fittings

Full Traceability. Material Specification. Raw Material Code. Heat Treatment

Rated to the New, Higher Pressure Classes in Latest Editions of AWWA C900 and C909. Joint Restraint Products

Victaulic Discharge CBV Vibration Isolation Pump Drop Series 383/383G

11.02 Mechanical-T Bolted Branch Outlets

MANUFACTURING SPECIFICATION

Section 3. Stainless Steel Series. Shurjoint Stainless Steel Piping Series Grooved Mechanical Couplings. Cast Grooved Fittings.

Lenntech Tel Fax

TRUSTED FOR 150 YEARS

Mechanical Piping Products

SUBMITTAL PACKAGE FIRE PROTECTION VALVES

STANDARD PIPE CLAMP FIG. 520 & 521

SEE VICTAULIC PUBLICATION FOR DETAILS

Ford Service Saddles and Tapping Sleeves

Series 756 FireLock Dry System Check Valve

Section 8 AMERICAN. Flanged Pipe

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

MACRO HP. NEW SMALLER SIZES Macro HP is Now Available for 2-12 inch Pipe Sizes. patent number:

THOMAS. Unifit Premier Series. Couplings & Flange Adaptors Non Restrained Products PIPE PRODUCTS

TABLE OF CONTENTS. Pipe Diameter Chart (Reference Only)..50 Extensions 38,40,42,44

GBV-G Balancing Valves

Ford Brass Saddles Style 101B and 202B

UNITED BRAND FITTINGS

Product catalogue. Mechanical accessories for pumps and mixers

Product Catalog. Rev. 612 r1

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

Series 758 FireLock Actuated System Valve

08.08 Vic-Check Valves

VR Piston Check Valves Submittal Data Sheet. Job or Customer: Engineer: Contractor: Submitted by: Approved by: Order No: Specification: introduction

TECHNICAL DATA OBSOLETE

Series 751 FireLock European Alarm Check Valve Stations

2500 PSI STANDARD FEATURES 2500 PSI CYLINDERS

Section N. 09/2017 Web Revision 10/23/2017 THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001: Ford Fabricated Steel Products

Utilities Catalog. PC-U2008, February, 2008

CHAIN & HOOKS. Proof Coil Chain Grade 28. Transport Chain Grade 70

StarFlex series 5000 Double-Ball Flexible Expansion Joint for the Protection of Water Wastewater, and Industrial Pipelines

Introduction. We stay ahead of today s evolving market requirements by committing to a program of continued research and development.

Ford Service Saddles and Tapping Sleeves

Pipe hanger solutions

MICROMOLD TM. PTFE Gaskets. Product Specifications. Envelope & Solid Donut Style 1, 2, 3 Sanitary

Model-1 Natural Gas Valves

Super Flange series 7200 Designed for use on Ductile Iron, Steel, PVC, PVCO and HDPE Pipes

INTEGRATED PIPING SYSTEMS. Technical manual. VSH Shurjoint

HIGH PERFORMANCE STEEL ANCHORS

Cooper & Turner Ltd STRUCTURAL

Product Specifications PIPE SUPPORT PRODUCTS

SJ-300N J-04. Model SJ-300N-L Butterfly Valve with Lever Handle

Model MTB-ASME Vertical Pre-Piped Bladder Tanks

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

FloCheck is a precision engineered, twin plate check valve suitable for product or service lines, wherever non-return protection is required.

1. Valves shall conform to the latest version of AWWA Standard C-509 covering Resilient Seated gate Valves for Water Supply Service.

Transcription:

Product Submittals for Project May 011-1

Couplings Figure 577 Light Weight Rigid Coupling For Fire Protection Pressure Rating and Listing / Approval information contact Tyco Fire Suppression & Building Products. Ductile Iron Housing Specifications ASTM A-536 Standard Specification for Ductile Iron Casting Grade 65-45-1 Tensile Strength, minimum psi 65,000 (448 MPa) Yield Strength, minimum psi 45,000 (310 MPa) Elongation in (50mm), minimum 1% ASTM A-153 Standard Specification for Hot Dip Galvanizing Bolt/Nut Specifications Carbon steel oval neck bolts and nuts are heat treated and conform to the physical properties of ASTM A-183 with a minimum tensile strength of 110,000 psi (760 MPa). Bolts and nuts are zinc electroplated to ASTM B-633. Metric - conforming to ASTM F-568M Coatings Orange Non-Lead (Standard) Fire Brigade Red Non-Lead (Optional) Hot Dipped Zinc Galvanized (Optional) Gasket Specifications Grade A EPDMA, violet color code ambient to +150 F (+66 C) for fire protection systems. Not recommended for hot water systems. Tri-seal (Grade E EPDM), green color code for use in dry pipe or freezer systems. Prelubricated (Grade A EPDMA) Project: Date: Architect / Engineer: Contractor: Address: Notes: May 011-45 Project Information: Phone: Technical Data Sheet: TFP1854 Date: March 011 Approval Stamp: Page 1 of

Couplings Figure 577 Light Weight Rigid Coupling (cont.) B C A FIGURE 577 GROOVED RIGID COUPLING 1-1 (DN5 TO DN) Nominal ANSI DN 1 DN5 1-1/4 DN3 1-1/ DN40 DN50-1/ DN65 DN65 3 DN80 4 DN100 DN15 5 DN15 DN150 6 DN150 8 DN00 10 DN50 1 DN Pipe Size O.D. 1.315 (33,4) 1.660 (4,) 1.900 (48,3).375 (60,3).875 (73,0) 3.000 (76,) 3.500 (88,9) 4.500 (114,3) 5.500 (139,7) 5.563 (141,3) 6.500 (165,1) 6.65 (168,3) 8.65 (19,1) 10.750 (73,1) 0 (33,9) Max. Pressures psi (bar) (4,1) (4,1) (4,1) (4,1) (4,1) (4,1) (4,1) (0,7) (0,7) (0,7) (0,7) (0,7) (0,7) 175 (1,1) 175 (1,1) Max. End Load Lbs. (kn) 475 (,11) 757 (3,37) 99 (4,41) 1,551 (6,90),7 (10,11),474 (11,01) 3,367 (14,98) 4,771 (1,) 7,17 (31,71) 7,90 (3,43) 9,955 (44,8) 10,341 (46.00) 17,58 (77,97) 15,883 (70,7),343 (99,4) Max. * End Gap 0.15 (3,) 0.15 (3,) 0.15 (3,) 0.15 (3,) 0.15 (3,) 0.5 (6,4) 0.5 (6,4) Nominal Dimensions A 1.63 ().66 (68).90 (74) 3.38 (86) 3.88 (99) 4.00 (10) 4.50 (114) 5.70 (145) 6.80 (173) 6.86 (174) 7.80 (198) 8.47 (15) 10.5 (60) 1.50 (318) 14.50 (368) B 3.9 (100) 4.40 (11) 4.66 (118) 5.0 (13) 5.64 (143) 5.78 (147) 6.33 (161) 7.50 (191) 8.75 () 8.8 (4) 9.75 (48) 9.88 (51) 1.78 (35) 16.50 (419) 18.50 (470) C 1.65 (4) 1.64 (4) 1.66 (4) 1.70 (43) (44) () (44) 1.83 (46).40 (61).56 (65).56 (65) Qty. Coupling Bolts Size** 3/8 x -1/4 3/8 x -1/4 3/8 x -1/4 3/8 x -1/4 3/8 x -1/4 3/8 x -1/4 3/8 x -1/4 M1 x 76 1/ x 3 M1 x 76 M1 x 76 1/ x 3 M1 x 76 5/8 x 3-1/4 3/4 x 4-3/4 M0 x 11 3/4 x 4-3/4 M0 x 11 Approx. Weight Lbs. (kg) 1. (0,55) 1.3 (0,59) 1.5 (0,68) 1.8 (0,8).0 (0,91).0 (0,91) 3.3 (1,50) 3.3 (1,50) 5.3 (,41) 5.3 (,41) 5.7 (,59) 5.9 (,68) 11.7 (5,3) 19.5 (8,86).0 (10,00) * Maximum available gap between pipe ends. Minimum gap = 0. Maximum Pressure and End Load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ for other pipe materials and/or wall thickness. Contact your GRINNELL Representative. ** Gold color coded metric bolt sizes for DN5 - DN couplings are available upon request. Max End Gap is for cut grooved standard weight pipe. May 011-46 Page of

COUPLINGS Figure 705 Flexible Coupling For Fire Protection Pressure Rating and Listing / Approval information contact Tyco Fire Suppression & Building Products. Ductile Iron Housing Specifications ASTM A-536 Standard Specification for Ductile Iron Casting Grade 65-45-1 Tensile Strength, minimum psi 65,000 (448 MPa) Yield Strength, minimum psi 45,000 (310 MPa) Elongation in (50mm), minimum 1% ASTM A-153 Standard Specification for Hot-Dip Galvanizing Bolt/Nut Specifications Carbon steel oval neck bolts and nuts are heat treated and conform to the physical properties of ASTM A-183 with a minimum tensile strength of 110,000 psi (760 MPa). Bolts and nuts are zinc electroplated to ASTM B-633. Coatings Orange Non-Lead (Standard) Fire Brigade Red Non-Lead (Optional) Hot-Dipped Zinc Galvanized (Optional) Gasket Specifications Grade A EPDMA, violet color code ambient to +150 F (+66 C) for fire protection systems. Not recommended for hot water systems. Tri-seal (Grade E EPDM), green color code for use in dry pipe or freezer systems. Prelubricated (Grade A EPDMA) Project: Date: Architect / Engineer: Contractor: Address: Notes: May 010-3 PROJECT INFORMATION: Phone: Technical Data Sheet: TFP180 Date: July 004 APPROVAL STAMP: Page 1 of

COUPLINGS Figure 705 Flexible Coupling (cont.) Pipe Max. * Max. Max. Nominal Dimensions Deflection Net Bolt O.D. End Gap Pressure End load A B C / Wt. Per Size** Size Psi Lbs. Foot Lbs. Coupling Dia. x Lg. mm mm kpa N mm mm mm mm/m kg 1.660 0.13 649.56 4.19 1.81 0.90 3 /8" x 1 /4" 1.5 1 1 4" 4-19' 4.4 3.3,068,887 65.0 106.4 46.0 75.0 0.7 1.900 0.13 850.75 4.44 1.81 0.79 3 /8" x 1 /4" 1.6 1 1 " 3-46' 48.3 3.3,068 3,781 69.9 11.8 46.0 65.8 0.7.375 0.13 1,38 3.5 4.88 1.88 0.63 3 /8" x 1 /4" 1.7 " 3-1' 60.3 3.3,068 5,907 8.6 14.0 47.8 5.5 0.8.875 0.13 1,947 3.69 5.50 1.88 0.5 3 /8" x 1 /4".0 1 " - 9' 73.0 3.3,068 8,660 93.7 139.7 47.8 43.3 0.9 3.000 0.13,10 4.00 5.75 1.88 0.50 3.1 76.1mm - 3' M1 x 76 76.1 3.3,068 9,430 101.6 146.1 47.8 41.7 1.4 3.500 0.13,885 4.38 6.50 1.88 0.43 1 /" x 3" 3.0 3" - 3' 88.9 3.3,068 1,83 111.3 165.1 47.8 35.8 M1 x 76 1.4 4.50 0.5 4,56 5.50 7.50.06 0.70 4. 108.0mm 3 - ' M1 x 76 108.0 6.4,068 18,931 139.7 190.5 5.3 58.3 1.9 4.500 0.5 4,769 5.69 7.75.06 0.67 1 /" x 3" 4.0 4" 3-11' 114.3 6.4,068 1,13 144.5 196.9 5.3 55.8 M1 x 76 1.8 5.50 0.5 6,494 6.56 9.50.06 0.56 7. 133.0mm - 44' 133.0 6.4,068 8,885 166.6 41.3 5.3 46.7 3.3 5.500 0.5 7,17 6.81 9.75.06 0.56 7. 139.7mm - 36' 139.7 6.4,068 31,701 173.0 47.7 5.3 46.7 3.3 5.563 0.5 7,88 6.88 9.75.06 0.54 5 /8" x 3 1 /4" 7.0 5" - 35' 141.3 6.4,068 3,417 174.8 47.7 5.3 45.0 3. 6.50 0.5 9,04 7.56 10.31.06 0.48 7.4 159.0mm - 17' 159.0 6.4,068 40,939 19.0 61.9 5.3 40.0 3.4 6.500 0.5 9,950 7.75 10.69.06 0.46 7.1 165.1mm - 1' 165.1 6.4,068 44,58 196.9 71.5 5.3 38.3 3. 6.65 0.5 10,336 7.94 10.69.06 0.45 5 /8" x 3 1 /4" 7.1 6" - 10' 168.3 6.4,068 45,975 01.7 71.5 5.3 37.5 3. 8.500 0.5 17,04 10.07 13.50.31 0.35 1.4 16.3mm 1-40' M0 x 11 16.3 6.4,068 75,73 55.8 34.9 58.7 9. 5.6 8.65 0.5 17,519 10.19 13.56.50 0.35 3 /4" x 4 3 /4" 14.5 8" 1-40' 19.1 6.4,068 77,95 58.8 344.4 63.5 9. M0 x 11 6.6 10.750 0.5 50,679 1.69 16.38.63 0.8 1" x 6 1 /" 8.0 10" 1-0' 73.0 6.4 1,74 100,876 3.3 416.1 66.8 3.3 M4 x 165 1.7 0 0.5 50 31,903 14.94 18.88.63 0.3 1" x 6 1 /" 36.5 1" 1-7' 33.9 6.4 1,74 141,905 379.5 479.6 66.8 19. M4 x 165 16.6 * Maximum available gap between pipe ends. Minimum gap = 0. Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Suppression & Building Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. ** Gold color coded metric bolt sizes are available upon request. Max End Gap and Deflection is for cut grooved standard weight pipe. Values for roll grooved pipe will be half that of cut grooved. May 010-4 Page of