ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

Similar documents
ACOUSTIC CABINET FANS CVB / CVT Series

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

ACOUSTIC CABINET FANS CVAB / CVAT Series

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

DIRECT-AIR ILB / ILT Series Rectangular duct fans

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

BELT DRIVEN CABINET FANS CVTT Series

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

Short casing. Long casing (L version) Commercial premises

COMPACT Series type HCFB / HCFT (Plastic impellers)

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

CENTRIFUGAL IN-LINE FANS VENT Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

supplied in Form (B) configuration. Airflow over Impeller- Motor.

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

MIXVENT-TH Series Mixed Flow Fans

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

Plate mounted axial flow fans HXBR / HXTR Series

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

CHMT Series, F Rated Fans

TGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

TGT Series Adjustable Pitch Fans

CVHT Series - F rated cabinet fans

TD-ECOWATT AND DECOR-ECOWATT Series

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

CYCLONE F 400 smoke extraction casing

Uniclass L7534. Manufacture controlled to ISO9001

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

NCF fans 50 Hz. Protection class IP 55

AC Commercial Fans Edition. ErP ready

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series

ROOF MOUNTED FANS MAX-TEMP Series, Centrifugal 400 ºC/2h Rated Fans

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

TD-SILENT Series (160 to 1000 models)

BATHROOM EXTRACT FANS DECOR-100 Series

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

GigaBox centrifugal fans Product specific information

VORTICENT C E RANGE Centrifugal fans

HIGH TEMPERATURE TWIN SQUIF FANS

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Sentinel D-Box Twin Fan

Acoustic Twin Fans (ATQ)

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

NEW Acoustic In-Line Fans (ACQ)

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

CYLINDRICAL CASED AXIAL FLOW FANS

Sentinel D-Box Single Fan

NEW Slimpak EC Box Fan (SLPT EC)

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

TD-SILENT range, the quietest fans in the world in their class

Max. airflow m 3 /s Diam. min. Diam. max

HIGH-POWERED VENTILATORS

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

MegaBox Product-specific information

MVF S.r.l. Via San Giovanni Bosco, Alessandria Tel Fax Web:

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

TD-SILENT range, the quietest fans in the world in their class

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

Bifurcated Case Axial Fans (BIFA)

NCF 60 Hz. Protection class IP 55

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

Square Mixed Flow Fans (MFQ)

series RVV Variable flow rate controllers

Centrifugal medium-pressure fans fitted with multi-blade

plates and with flexible conduit. Ø Outlet (mm)

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

BPF. Centrifugal Plug Fans

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Transcription:

ACOUSTIC CABINET FANS CENTRIBOX CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive forward curved centrifugal fan fitted with anti vibration mounts and IP55 remote terminal box. All cabinets can be installed outdoors as standard. Available, depending upon the model, with single phase motors in 4 or 6 poles. Motors Motors are IP44 (1) Class F insulation, with ball bearings and thermal protection. Electrical supply: Single phase 230V-50Hz. Three phase 230/400V-50Hz. (See characteristics chart). All models are speed controllable. (1) Model CVT 380/380-N-2200W is IP54 Class F. Outdoor installation Easy to mount Acoustic insulation of 7 mm All cabinets can be installed All models are supplied with thickness flame retardant (M1) outdoors as standard four mounting feet to facilitate installation melamine foam reducing the noise level significantly Flame retardant IP55 remote terminal box Anti-vibration mounts Circular duct connection flanges To ease installation and Reducing vibration and noise In line circular duct connection connection to external controls transmission to the installation flanges at the inlet and discharge P L I C A T I O N Warehouses Workshops Commercial premises Offices Restaurants and cafes Commercial and industrial kitchens S Low noise level P A

Technical characteristics Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency etc) match those of the intended electrical supply. * The sound levels shown on the curves are radiated sound pressure levels, measured at 1,5 m, in free field conditions and outlet ducted. Acoustic characteristics Speed Motor power Protection absorbed Insulation class Sound power level spectrum in db(a) at the corresponding frequency band in Hz: The sound levels NPS- shown in the technical characteristics chart for the S&P fans, generally correspond to a value of sound pressure db(a), measured in free field conditions at a distance of 1,5m. Model 63 125 250 500 1000 2000 4000 8000 Inlet 39 44 49 55 53 45 42 34 CVB-180/180 N 72W Outlet 39 46 52 59 65 63 59 53 Rad. 39 41 42 44 42 35 29 23 Inlet 46 50 55 60 57 50 48 39 CVB/4-180/180 N 150W Outlet 46 52 58 64 69 68 65 58 Rad. 46 47 48 49 46 40 35 28 Inlet 44 51 60 65 60 52 49 39 CVB-240/180 N 250W Outlet 44 53 63 69 72 70 66 58 Rad. 44 48 53 54 49 42 36 28 Inlet 46 53 60 64 59 51 46 37 CVB-240/240 N 250W Outlet 46 55 63 68 71 69 63 56 Rad. 46 50 53 53 48 41 33 26 Inlet 49 57 65 67 64 57 55 44 CVB/4-240/240 N 370W Outlet 49 59 68 71 76 75 72 63 Rad. 49 54 58 56 53 47 42 33 Inlet 43 52 60 66 61 55 53 44 CVB-270/200 N 370W Outlet 43 54 63 70 73 73 70 63 Rad. 43 49 53 55 50 45 40 33 Inlet 49 56 63 66 64 57 56 45 CVB/4 270/200 N 370W Outlet 49 58 66 70 76 75 73 64 Rad. 49 53 56 55 53 47 43 34 Max. abs. current single phase 50 Hz 230 V (A) Max. abs. current three phase 50 Hz 230 V (A) 400 V (A) Max. Sound Weight Speed air pressure Controller volume level * Model (r.p.m.) (W) (CV) (m 3 /h) (db(a)) (kg) 6-POLE MOTOR CVB-180/180-N-72W EXPORT 900 72 1/10 IP44 F 0,8 1410 55 22 REB-1N CVB-240/180-N-250W EXPORT 900 250 1/3 IP44 F 2 2680 61 35 REB-2,5N CVB-240/240-N-250W EXPORT 900 250 1/3 IP44 F 2,2 2720 61 36 REB-2,5N CVB-270/200-N-370W EXPORT 900 370 1/2 IP44 F 4 3950 64 42 REB-5 CVB-270/270-N-370W EXPORT 900 370 1/2 IP44 F 4 4340 66 44 REB-5 CVB-320/240-N-550W EXPORT 900 550 3/4 IP44 F 5,8 5400 63 55 REB-10 CVT-320/240-N-1100W EXPORT 900 1100 1,5 IP44 F 7,1 4,1 7000 72 55 RMT-5 CVB-320/320-N-550W EXPORT 900 550 3/4 IP44 F 5,8 5670 65 58 REB-10 CVT-320/320-N-1100W EXPORT 900 1100 1,5 IP44 F 7,3 4,2 7900 72 58 RMT-5 CVT-380/380-N-2200W EXPORT 940 2200 3 IP54 F 8,8 5,1 10600 70 70 VFKB 48 6-POLE MOTOR CVB/4-180/180-N-150W EXPORT 1400 150 1/5 IP44 F 1,5 1400 59 23 REB-2,5N CVB/4-240/240-N-370W EXPORT 1400 370 1/2 IP44 F 3,9 2640 66 38 REB-5N CVB/4-270/200-N-370W EXPORT 1400 370 1/2 IP44 F 4,5 3000 66 44 REB-5N CVB/4-270/270-N-550W EXPORT 1400 550 3/4 IP44 F 4,3 3430 67 46 REB-5 Model 63 125 250 500 1000 2000 4000 8000 Inlet 45 53 60 65 61 54 51 42 CVB-270/270 N 370 W Outlet 45 55 63 69 73 72 68 61 Rad. 45 50 53 54 50 44 38 31 Inlet 52 62 67 68 65 58 56 46 CVB/4-270/270 N 550 W Outlet 52 64 70 72 77 76 73 65 Rad. 52 59 60 57 54 48 43 35 Inlet 48 60 63 66 61 57 54 45 CVB-320/240 N 1100 W Outlet 48 62 66 70 73 75 71 64 Rad. 48 57 56 55 50 47 41 34 Inlet 62 64 67 70 65 61 58 49 CVT-320/240 N 1100 W Outlet 62 66 70 74 77 79 75 68 Rad. 62 61 60 59 54 51 45 38 Inlet 50 60 64 71 63 58 56 47 CVB-320/320 N 550 W Outlet 50 62 67 75 75 76 73 66 Rad. 50 57 57 60 52 48 43 36 Inlet 54 64 68 75 67 62 60 51 CVT-320/320 N 1100 W Outlet 54 66 71 79 79 80 77 70 Rad. 54 61 61 64 56 52 47 40 Inlet 56 65 69 73 66 62 60 51 CVT-380/380 N 2200 W Outlet 56 67 72 77 78 80 77 70 Rad. 56 62 62 62 55 52 47 40

Technical characteristics Q = Air volume in, m 3 /hr and m 3 /s. Pst = Static pressure in mmwg and Pa. Dry air at 20ºC and 760 mmhg. Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.

Technical characteristics Q = Air volume in, m 3 /hr and m 3 /s. Pst = Static pressure in mmwg and Pa. Dry air at 20ºC and 760 mmhg. Performance data in accordance with ISO 5801 and AMCA 210-99 Standards. Electrical accessories REB Single phase electronic speed controllers. RMB/RMT Single and three phase auto transformer speed controllers. On/ Off Electrical isolation switch - Switch On/ Off 5P - Switch On/ Off 8P REB-5 Single phase electronic speed controllers. VFKB Adjustable frequency drives for three phase motors from 0,37 to 4 kw 230 V or 400 V.

Mounting accessories CBR Rectangular Duct Connectors Can be used instead of the circular spigots supplied as standard. Model Flange nominal dimensions (mm) CVB-180/180 CBR-180 x 180 CVB-240/180 CBR 240 x 180 CVB-240/240 CBR 240 x 240 CVB-270/200 CBR 270 x 200 CVB-270/270 CBR 270 x 270 CVB-320/240 CBR 320 x 240 CVB-320/320 CBR 320 x 320 CRC Circular reducers To enable the connection of a smaller diameter ducting. Model Nominal reductions available (mm) CVB-180 CRC 250/200 CVB-240 CRC 355/315 CRC 355/250 CVB-270 CRC 400/355 CRC 400/315 CRC 400/250 CVB / T-320 CRC 500/450 CRC 500/400 CRC 500/315 MSO-KAD Flexible couplings Circular flexible connectors type MSO. Rectangular flexible connectors type KAD. KSE Flexible supports Rubber anti-vibration mounts to reduce vibration and noise transmission to the installation. (1KSE = set of 4 supports per bag) APC Round outlet guards Discharge protection guards for direct connection to the inlet-outlet flange (please see pages. Mounting Accessories). Model Circular Rectangular CVB-180 MSO 250 KAD 250 x 250 CVB-240 MSO 355 KAD 350 x 350 CVB-270 MSO 400 KAD 400 x 400 CVB / T-320 MSO 500 KAD 450 x 450 Model Type KSE CVB-180 KSE 45 CVB-240 KSE 45 CVB-270 KSE 45 CVB / T-320 KSE 45 Model Type of protection guard Nominal Ø diameter CVB-180 APC-250 250 CVB-240 APC-355 355 CVB-270 APC-400 400 CVB/T-320 APC-500 500 SIL Sound attenuators

Mounting options Standard circular flange Mounting options APC Round outlet protection CBR Rectangular flange CRC Circular reducer CVB/CVT 180 to 320 M x N: Inlet flange/ M = Width x N = Height (see mounting types sketch). KAA Circular flexible coupling KAD Rectangular flexible coupling KSE Flexible supports 88 403 = 600x600 = 30 1018 40 CVT 380/380 = 473 = 950 Model A B C Ø D E F H CVB-180/180 455 441 408 250 436 422 245 CVB-240/180 565 521 508 355 536 532 282 CVB-240/240 565 521 508 355 536 532 282 CVB-270/200 605 581 558 400 586 572 322 CVB-270/270 605 581 558 400 586 572 322 CVB/T-320/240 685 669 608 500 636 652 376 CVB/T-320/320 685 669 608 500 636 652 376 775