Transformer Components & Accessories

Similar documents
THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

Valve Selection. 1. Function and service considerations

H1 H2 H3 X0 X1 X2 X3

Power Voltage Transformers for Air Insulated Substations

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Bushings for High Voltage AC Applications

Confidence with the global standard in pressure relief devices

V. Design, Application, Maintenance & Operation Technical Requirements

Transformer bushings, type GOH. Technical guide

ROGERS MACHINERY COMPANY, INC

C1000 Series Automatic Cap Bank

BUSHINGS AND ACCESSORIES FOR DISTRIBUTION AND POWER TRANSFORMERS

EMPAC Metal enclosed capacitor bank for wind applications

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

ROGERS MACHINERY COMPANY, INC

Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer

SECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.

LV Bushing Oil to Air Dry Insulation PTAB-SLV832

dfdf 34.5 kv and 69 kv, Type O Plus C II Condenser Bushings Technical Guide

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

We uses No Cobalt (Neo-Blue) of pro-environment as dehydrator to be filled in the container of all breathers.

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

MEDIUM POWER TRANSFORMER

Figure 1710 Flow Data

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

CENTRIFUGAL PUMP AND SEAL (API Std. 610 and 682) Presented By Prakash Kumar ME(NSPL)

Pretest Module 29 High Voltage Unit 1

15100 VALVES. E. Section Building Automation and Control System Guidelines

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Sample Specifications 2111_A00.doc 01/18/06 KOBELCO KNWA00 SERIES 1 of 8 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame HP

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

Buchholz Relay MBP Gas and Oil Actuated Relay

VB VALVES & AUTOMATION

Small wonder. Station service voltage transformers for small power requirements

Climas y Proyectos Leyco, S.A. de C.V.

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

Q pole Pole Mounted Capacitor System

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

Distribution transformers Efficiency over life-cycle

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Three-Phase Pole Mounted Recloser

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

Solution Overview. Asset Condition Monitoring. Extend operational life and reduce downtime

NEW Solutions for Underground System Growth

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

September 2008 TEC, INTELLIGENT MONITORING SYSTEM

Temperature Regulators

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

SPECIFICATION SS-52/15 8 MVAR 25 MVAR, 157.5kV SHUNT REACTORS

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Uniflex-stow remote valve operating systems

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves.

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Flow Data for NIBCO Circuit Balancing Valves 1/2 to 2 (Figure Number 1710)

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

Publication No.: PSG

Purging Air From Divider Block Lubrication Systems

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

TYPE PC Propeller Condensate Pumps

CP Automatic capacitor bank

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

GENERAL. CONSTRUCTION External

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SECTION VALVES AND OPERATORS

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

First Applications on AltaLink s Network. Roggero Ciofani, P. Eng. Colin Clark, P. Eng.

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

PWA-LF LOW FLOW ANSI PROCESS PUMP

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Applied to Equipment Instruction Number R Class-Group Generate Date: 11 March 2004

Air-insulated switchgear UniGear type ZS1

Volt Instrument Transformers

Yarway Hy-Drop Throttling valve

TRANSFORMERS UP TO 750 kv

Crispin Valves Operating Guide. Crispin

Transformer bushings and oil leaks. A cost effective way to address oil and nitrogen leaks MAINTENANCE ABSTRACT KEYWORDS. 1.

Transportation Products

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

SECTION MISCELLANEOUS VALVES

Power systems Protection course

ABB Transformers Egypt

Solid Dielectric, Independent Pole Operated Reclosers Catalog O-vst16

Transcription:

Transformer Components & Accessories Brian Brinson Mechanical Design Manager brian.brinson@spx.com

Agenda 1. Standards / Equipment Overview 2. Bushings 3. Arresters 4. Cooling Equipment 5. Instrument Transformers 6. Gauges 7. Pressure Controls & Relays 8. Valves 9. Transformer Health Equipment 2

Standards / Equipment Overview 3

Standards IEEE Standards C57.12.10 2017 Standard Requirements for Liquid-Immersed Power Transformers C57.12.00 2015 General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers C57.19.00 2004 Standard General Requirements and Test Procedure for Apparatus Bushings C57.19.01 2000 Performance Characteristics and Dimensions for Outdoor Apparatus Bushings C57.13 2016 Standard Requirements for Instrument Transformers Web Address to IEEE Digital Library (Subscription Required) www.ieeexplore.ieee.org 4

C57.12.10 Basic Standard 5

C57.12.10 Basic Standard Features 6

Bushings 7

Common Bushings Types Dry (Bulk) Type up to 35kV Composite up to 170kV Paper Resin Condenser (PRC) 15kV - 69kV Paper Oil Condenser (POC) 25kV - 800kV While grey porcelain is the industry standard polymer sheds are becoming more commonly accepted. 8

Bushing Selection Considerations Electrical Rating Requirements Nominal System Voltage BIL Rating Nominal Current and any Overload Requirements Draw-lead vs Bottom Connect or split conductor Mechanical Requirements Vertical Mount vs Horizontal Mount (important for bushings with oil) Temperature Requirements o High temp bushings may be necessary for use in enclosed ducts or other conditions Environmental Requirements Bushing Mounting o Oil Air / Oil SF6 / Oil - Oil o Flange bolting and gasket requirements for retrofits Mechanical Strength o Cantilever Requirements o Seismic Certification if required Bushing clearances (both external and internal) Ground Sleeve Length (CT Pocket) Other Considerations Existing supply of spare bushings 9

Bushings Mounting Cover Mounted Horizontal Mount Tilt Mount 10

Arresters 11

Common Arresters Types Polymer Arrester Porcelain Arrester Advantages Light Weight Compact Durability Smaller Phase to Phase & Phase to Ground Clearances Will not shatter explosively like porcelain arresters Advantages High cantilever strength for windstorms or earthquakes Better UV resistance than polymer arresters Both types are available in Station and Intermediate Classes 12

Arrester Selection Considerations Electrical Rating Requirements Maximum system voltage System grounding practices (effectively grounded, impedance grounded, ungrounded) Insulation level of equipment to be protected Desired margins of protection to be provided Mechanical Requirements Vertical Mount vs Horizontal Mount Operating Conditions (Ambient temperature, altitude, etc.) Mechanical Strength o Cantilever Requirements o Seismic Certification if required Other Considerations Existing supply of spare arresters 13

Cooling Equipment 14

Radiators Galvanized Painted Panel-type galvanized (standard) or painted (ANSI 70 or another color) Cool through natural convection, ONAN transformer rating does not require auxiliary equipment 15

Radiator Header Banks Typically used when cooling needs exceed the space available for direct mount Common on larger FR3 designs or when there are limitations on where radiators can be placed 16

Fans Radiator Mounted Frame Mounted Available in variety of voltages including single phase and three phase Higher RPMs and larger diameter provide more cooling but increase sound level and power requirements Sound level and CFM are main concerns Careful consideration is given in the cooling design to ensure the optimal size, type, and quantity of fans is selected to meet all the design requirements. 17

Oil to Air & Oil to Water Coolers with Pumps Oil to Air Coolers with Pumps Used primarily when space / weight is a concern, such as mobile transformers, large power transformers and when remote cooling is required Pumps require power at all times Oil to Water Coolers with Pumps Small physical footprint Require cool water supply and pumps require power at all times Pumps Axial Centrifugal Flow Indicator Isolation Valves Expansion Joints 18

Instrument Transformers 19

Bushing Current Transformers Typical internal CT Under-Cover Mounted CTs Turret Mounted CTs Typically mounted so that bushing passes through CT In some cases line lead will be routed through CT Available as internal or external to tank Metering and relaying accuracy Depending on CT requirements a single CT can cost as little as $200 each or as much as $25,000 or more! 20

Gauges 21

Analog Temperature Gauges Liquid Temperature measures Top Oil Temperature Winding Temperature simulates Winding Temperature Hotspot Analog Gauges Analog w/scada Output Analog gauges typically mounted between 4-6ft above base with capillary tube to respective well Direct mount gauges are available when required tilted downward to aid viewing LTC transformers may be requested with additional liquid temperature indicators Winding temperature gauges can be specified to monitor additional windings 22

Electronic Temperature Monitors ETM Examples Electronic temperature monitors are becoming more and more common Still fairly common to see both analog and electronic monitors required for redundancy Consider whether or not you plan to do your own programming in the field Make sure your spec is clear if you want the transformer manufacturer to do the programming for you as this can be costly Its not uncommon for the programming to cost several times more than the device. Scheduling of the programming with vendor can create delays in production. 23

Liquid Level Gauges Typical tank mounted liquid level gauge Remote liquid level gauge and monitor Provides indication of oil level in transformer or oil filled compartment Can be provided with alarm/trip contacts for high / low / critical low oil level Typically must be mounted at the 25 degrees C oil level LTC with separate oil filled compartment will have separate gauge Remote gauges can be used on conservators when gauge is to far away to read from ground level 24

Pressure Controls and Relays 25

Rapid Pressure Rise Relay Qualitrol Gas space mounted Qualitrol Oil Flange mounted Relay typically mounted in the gas space but can be mounted in oil if specified Qualitrol Gas space 910 series; Oil space mounted 900 series ABB only offers gas space type When mounted in oil it should be mounted on a full bore valve to ensure functionality is not compromised and to ease maintenance Gas space mounted relay operates slightly faster than oil flange mounted Buchholz offers model which can be used only on conservator units 26

LTC Pressure Switch & Buchholtz Relay LTC Pressure Switch LTC can use the same pressure switch/ relay as main tank or could utilize pressure switch Buchholz Relay Installed between the main tank and conservator Device will alarm / trip on Gas accumulation Loss of fluid (low oil level) High pressure wave Site glass for visual indication of gas on inspection Bleeder valve and sampling port are available 27

Gas Accumulator Indicator Conservator Provides visual evidence of gas generation Can be wired to alarm when the amount of gas reaches a preset level Factory tested by injecting air in bottom drain valve 28

Pressure Relief Devices Spring operated device which operates at a factory preset pressure (typically 10 psi) Self-resetting (great improvement on early rupture discs) Options: Contacts to alarm for operation Semaphore (flag) to visually indicate operation Discharge Piping to direct oil to safe location 29

Pressure Relief Devices Directional Piping Qualitrol XPRD most common 8 Pipe Directed blow off piping Discharge routed to ground Screen option available to keep out critters Tubing available in PVC, aluminum and steel Qualitrol XPRD 30

Valves 31

Valve Applications Filling and Draining Required for filling and draining the main tank, LTC compartment, and conservator when applicable Isolation of Components Allows for isolation of components which may require removal in the future for maintenance or replacement Limits the amount of oil removed from the transformer when replacing components Some examples are radiators, RPRR, Buchholz Relay, and Monitoring Equipment Vacuum Isolation / Equalization Applicable to some LTC compartments and conservator air cells 32

Common Valve Variations Valve Types Globe Gate Ball Butterfly Pressure Relief Sampling / Venting Valve Connection Flanged Threaded Valve Materials Bronze Brass Cast Iron Stainless Steel Valve Construction Unibody 2-Piece 3-Piece 33

Valve Materials Bronze Relatively low cost and available in 3 sizes and below Good corrosion resistance for most environments including salt spray Less availability above 2 for some valve / connection combinations Brass Lowest cost valve material Limited availability in larger sizes More susceptible to galvanic corrosion than Bronze Softer than bronze, more susceptible to thread damage Stainless Steel Highest cost valve material Excellent corrosion resistance including refinery / high sulfur environments Available for all valve types, sizes and materials Cast Iron / Steel Much lower cost than stainless for large valves Readily available in larger sizes Requires painting for corrosion resistance 34

Valve Connections Flange In Thread Out Typical for filling applications when a threaded connection is required for field use Limited availability in unibody styles for ball valves and sizes above 2 May require custom design Thread In Thread Out Widely available for all valve types, sizes, and materials Not recommended for sizes above 2 due to greater potential for leaks Flange In Flange Out Excellent Seal Good for in-line applications May not be best for filling/ draining unless fill hoses are equipped with adapters Not as readily available for smaller sizes in all materials 35

Valve Construction Unibody Typically lowest cost Reduced number of leak points Lower availability for sizes above 2 for some connections/material combinations Limited options for repair Three Piece Body Body can be removed for repair without disturbing flanges on in-line applications Two additional leak points Two Piece Body Greater availability for sizes above 2 Flange In Thread Out available Valve can be repaired, but must be removed from service One additional leak point Flange In Thread Out available with custom valve design 36

Globe Valves Good throttling Excellent for filling applications to control flow rate Leak resistance Can have a Sample valve Flange or screw attachment High head loss Lower flow rates 37

Gate Valves Linear motion valve Used to start or stop fluid flow, does not regulate or throttle flow Minimum leakage is allowed Virtually no resistance across valve used on rapid pressure relay type devices Rising and non-risings stem styles Can be expensive in larger sizes 38

Ball Valves Quick open ¼ turn full flow Excellent sealing High flow low head pressure Hard to find with Sampler valve Expense in sizes over 3 39

Butterfly Valves Quick open/close rotating disk Excellent sealing two types O-ring on disk resilient-seated Good flow some head loss due to disk in stream Compact Full vacuum without face plate, compared to older flapper style Able to be welded directly to the tank wall 40

Transformer Health Equipment 41

Dehydrating Breathers Ensure dry air is maintained inside LTC, conservator, sealed tank or control cabinet, improving reliability Air flows through silica gel to remove moisture prior to entering air space Silica gel may be recharged by heating or replaced with new gel Auto-Recharging Breathers Recharge automatically, eliminating the need for manual regeneration or replacement of silica gel Remote indication of recharging cycles and equipment alarms is possible 42

LTC Oil Filtration Systems Typically used on non-vacuum LTCs to remove carbon and metallic particle contaminants (down to 3 microns) and free moisture in oil Maintain condition of LTC oil to extend the life of equipment and can extend the period between maintenance intervals May be retrofit to existing units in the field 43

Electronic Monitoring Monitoring and control are available in a variety of packages and units, transformer requirement vary by make and model Alarm conditions Transformer loading and calculations LTC condition and control Online DGA Online bushing power factor and capacitance measurement Fiber optic temperature monitoring Useful on older equipment to monitor unit condition Less value on new equipment but does provide baseline information for future condition assessment 44

Questions? Thank you! 45