ONE FLOOR DRAIN IS REQUIRED FOR EACH CASE. NSF

Similar documents
ONE FLOOR DRAIN IS REQUIRED FOR EACH CASE. NSF

Insight IDD5SU P/N _L NSF IMPORTANT. Certified. Dairy / Delicatessen / Beverage with EcoVision Doors

Optional Condensate Pans

Insight ID6SU P/N _K NSF IMPORTANT. Certified. Dairy / Delicatessen

Electrical Box. Optional. Condensing Unit (Field Installed)

Insight IC6SL P/N _L NSF. Certified. Dairy / Delicatessen / Meat

Insight ID5SL P/N _L NSF. Certified. Dairy / Delicatessen / Beverage

Insight IC2SL P/N _J NSF. Certified. Dairy / Delicatessen / Meat

Optional Condensate Pan. Electrical Box

Optimal Shelf Life. Conventional Controls IP4NL. Low Pressure Backup Control CI/CO 8 20 F / 10 F 6.67 C / 12.2 C

Insight IDD5SV P/N _E NSF. Certifi ed. Dairy / Delicatessen / Beverage with EcoVision Doors

Insight ID5SMI45 P/N _B NSF. Certified. Dairy / Delicatessen / Beverage

Insight IC4BM P/N _E NSF. Certifi ed. Dairy / Delicatessen / Meat / Produce

Insight IC4SL P/N _F NSF. Certifi ed. Dairy / Delicatessen / Beverage / Meat

Fan Speed Selector (when applicable)

Insight ID5SM P/N _K NSF. Certifi ed. Dairy / Delicatessen / Beverage

Insight ID5NL P/N _H NSF. Certifi ed. Dairy / Delicatessen / Meat

Insight ID5NM P/N _J NSF. Certifi ed. Dairy / Delicatessen / Meat

Insight IM1SL P/N _H NSF. Certifi ed. Meat. Insight standard field electrical connections are at the bottom of the merchandiser.

Insight IP1SL P/N _F NSF. Certifi ed. Bulk Produce. Insight standard field electrical connections are at the bottom of the merchandiser

ESGMVS Technical Data Sheet

ESBD P/N _D NSF. Certified G K B E G F H K A. Technical Data Sheet. April Spanish P/N Data sheet-elite-esbd

ESGM Technical Data Sheet

ESBDHV Technical Data Sheet

C5NX-LE P/N _L NSF. Certified. Technical Data Sheet. April Spanish P/N

CW2UGE E G A D. Certified. Technical Data Sheet P/N _B NSF. November Item Part # Description Wiring Item #

M3X-GE. P/N _F NSF Certified P/N_ _F. Technical Data Sheet. March 2010 F E B E. Item Part # Description Wiring Item #

M5X-GE. P/N _E NSF Certified P/N_ _E. Technical Data Sheet. March Item Part # Description Wiring Item #

DD6X-ULP Technical Data Sheet

DDF5NX-L. Certified. Technical Data Sheet P/N _E NSF. January 2018 B A. Scan QR code to access product information on your. mobile device.

DD6NX-L Technical Data Sheet

DD5X-ULP IMPORTANT. Certified. Technical Data Sheet P/N _K NSF. July Scan QR code to access product information on your mobile device.

DD6X-URE P/N _G NSF IMPORTANT. Certified. Technical Data Sheet. April Spanish P/N

DD5NX-L. Certified. Technical Data Sheet P/N _H NSF. July Scan QR code to access product information on your mobile device.

DD5X-LP. Certified. Technical Data Sheet P/N _K NSF. July Scan QR code to access product information on your mobile device.

D5X-EP Technical Data Sheet

M5X-EP Technical Data Sheet

M4X-EP P/N _M NSF. Certified. Technical Data Sheet. April Scan QR code to access product information on your mobile device.

DD5X-LR P/N _J NSF. Certified. Technical Data Sheet. April Scan QR code to access product information on your mobile device.

M5NX-EP P/N _J NSF. Certified. Technical Data Sheet. April Spanish P/N

C5X-EP P/N _L NSF. Certified. Technical Data Sheet. April Scan QR code to access product information on your mobile device.

C2X-EP P/N _P NSF. Certified. Technical Data Sheet. April Spanish P/N

C2X-LEP P/N _R NSF. Certified. Technical Data Sheet. April Spanish P/N

D5X-E P/N _M NSF. Certified. Technical Data Sheet. April Scan QR code to access product information on your mobile device.

P2X-EP P/N _J NSF. Certified. Technical Data Sheet. April 2017

C6X-LEP P/N _Q NSF. Certified. September Spanish P/N Technical Data Sheet

C2X-LEP. P/N _K NSF Certified F E P/N_ _K. Technical Data Sheet. April Item Part # Description Wiring Item #

C2NX-EP P/N _B NSF. Certified. Technical Data Sheet. April Spanish P/N

D6X-ULEP Technical Data Sheet

C2NX-XLP P/N _F NSF. Certified. Technical Data Sheet. April Spanish P/N

FL5NX-LEP P/N _F E D A D B D P/N_ _F. Technical Data Sheet. March Item Part # Description Wiring Item #

CF5X P/N _J NSF. Certified. Technical Data Sheet. October Scan QR code to access product information on your mobile device.

B4X-E P/N _L NSF. Certified. Technical Data Sheet. April Spanish P/N

D5X-HEP P/N _P NSF. Certified. Technical Data Sheet. February Scan QR code to access product information on your mobile device.

DF5NX P/N _J NSF. Certified. Technical Data Sheet. January Scan QR code to access product information on your mobile device.

D6NX-LEP P/N _Q NSF. Certified. Technical Data Sheet. February Scan QR code to access product information on your mobile device.

C2X-LE P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet. October Spanish P/N

ME5X-GP P/N _G NSF. Certified. Technical Data Sheet. April Spanish P/N

P2X-E P/N _L NSF. Certified. Technical Data Sheet. October 2017

CW2UGE Technical Data Sheet

C2-LE P/N G. P/N _G NSF Certified. Technical Data Sheet. November 2009

C2-LGE P/N D. P/N _D NSF Certified. Technical Data Sheet. November 2009

SMGV Technical Data Sheet

P4X-E. P/N _J NSF Certified P/N_ _J. Technical Data Sheet. September Item Part # Description Wiring Item #

SMGT Technical Data Sheet

FL5NX-LEP P/N _L. Technical Data Sheet. April Spanish P/N Item Part # Description Wiring Item #

M5 Technical Data Sheet

P2X-E. P/N _J NSF Certified P/N_ _J. Technical Data Sheet. September Item Part # Description Wiring Item #

Electrical Box Power Cord

M1-GEB Technical Data Sheet

D5RRI P/N B. NSF Certified. Technical Data Sheet. June 2006 P/N B. Item Part # Description Wiring Item #

RI4 P/N _G NSF. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet. November Serial Plate

D5RRIS. P/N B NSF Certified. Technical Data Sheet. June 2006 P/N A. Item Part # Description Wiring Item #

PW-E. Certified. Technical Data Sheet P/N _E NSF. October 2016

PWW-E. Certified October Technical Data Sheet P/N _C NSF

C2-XGE P/N C. NSF Certified. Technical Data Sheet. February 2006

CW2EGE C E. Technical Data Sheet P/N _B NSF. Certified. November Item Part # Description Wiring Item #

Elevated C2-LE P/N D. NSF Certified. Technical Data Sheet. February Note: Changed items have been underlined.

LED FIXTURES AND POWER SUPPLY. (C) Power Supply (D)

EQUIPMENT INFORMATION SHEET REFRIGERATION - MEDIUM TEMP. Link to PDF file

RMT with P/N _H NSF. INNOVATOR Doors or INNOVATOR III Doors. Certified. Technical Data Sheet. June 2015

CW2U-XGE. Technical Data Sheet P/N B. NSF Certified E G F A D C. April Note: Changed items have been underlined.

F2XLG Technical Data Sheet

Insight ID5SM-W U L US C P/N _B NSF. Certified LISTED. Dairy / Delicatessen / Beverage Water-coooled Self-Contained R290 (Propane)

Double Curved Glass. Merchandisers NEBCH. (Modified Front for Impact) Data Sheet Set P/N A. June, 1998 LAMPS AND BALLASTS

Excel DD5X5FRW U L US C P/N _E UL EPH IMPORTANT. Certified LISTED. Dairy / Delicatessen Self-Contained R290 (Propane)

IMPACT 3-Pin Shelf Lamp LED Retrofit for Hussmann Cases Manufactured AFTER February 2001

O2.5UMAK-NRG O2.5UMAK-NRG. Multi-Deck Mobile Self-Contained Merchandiser 4', 6' & 8' Case (Meal Kit) SHIPPING WEIGHT GENERAL NOTES

Ambient Pastry Case Family

OUM-NRG OUM-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Meat / Produce / Seafood) GENERAL NOTES:

INNOVATOR DOOR SYSTEM FOR WALK-IN COOLERS

OHM-NRG OHM-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

EcoShine II Vertical LED Lights

O5DMA-NRG O5DMA-NRG. Self-Contained Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Beverage / Produce) SHIPPING WEIGHT GENERAL NOTES

INNOVATOR DOOR SYSTEM FOR WALK-IN COOLERS

OHP-NRG OHP-NRG. Multi-Deck Merchandiser 4', 6', 8' & 12' (Produce) SHIPPING WEIGHT Case Weight OHP-NRG ---

Multi Purpose Dairy Produce Packaged Meats Self Contained Remote Island Endless Line - Ups 30 to 40 Deep 44 to 84 High

EcoVision Door Upgrade for Insight Medium Temperature Merchandisers

O5DMH-NRG O5DMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT

ECOVISION DOOR SYSTEM FOR

Transcription:

Insight standard field electrical connections are at the top left of the merchandiser Field Electrical Connection Power Supply Insight IDD6SU with EcoVision Doors Merchandiser Data Sheet P/N 0550565_L NSF Certified May 2018 Coil* Fan* Thermoexpansion Valve* Canopy LED Lights Shelf LED Lights *Coils, fans and TXVs are modular with one per 3 or 4 foot section. Portion of parts removed for clarity. 12 foot merchandiser shown. IMPOTANT ONE FLOO DAIN IS EQUIED FO EACH CASE. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials and cleanability. Performance Data Page 2 Product Data (AHI Statistics) Page 2 Cross Section Page 3 Plan View Page 4 Electrical Loads Page 6 Estimated Shipping eights Page 7 Shelf Options Page 7 eplacement Parts List Page 8 iring Diagrams Page 9 Computing efrigeration and Electrical Load Page 12 evision History Page 12 e reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Data sheet-insight IDD6SU 2018 HUSSMANN COPOATION BIDETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900.HUSSMANN.COM Spanish P/N 0550566

Insight IDD6SU Dairy / Delicatessen efrigeration Data 1 Unlit Mullions Lit Mullions IDD6SU Optimal Shelf Life Door Option EcoVision EcoVision HA EcoVision HA+ Application Dairy/Deli/ Beverage/ Produce Pegs 3 Convertible/ Meat NSF Type 2 Ambient 4 Harsh Environment Energy Comparison EcoVision AHI 1200 ating Point 5 Discharge Air F ( C) 37 (2.77) 36 (2.22) 34 (1.11) 33 (0.55) 31 (-0.55) 37 (2.77) Average Evaporator F ( C) 2 34 (1.11) 33 (0.55) 31 (-0.55) 30 (-1.11) 28 (-2.22) 34 (1.11) Parallel Btu/hr/ft (atts/m) 290 (279) 320 (308) 340 (327) 350 (337) 425 (409) 290 (279) Conventional Btu/hr/ft (atts/m) 300 (288) 330 (317) 350 (337) 360 (346) 435 (418) 300 (288) Discharge Air F ( C) 36 (2.22) 35 (1.66) 33 (0.55) 32 (0) 30 (-1.11) 36 (2.22) Average Evaporator F ( C) 2 33 (0.55) 32 (0) 30 (-1.11) 29 (-1.67) 27 (-2.77) 33 (0.55) Parallel Btu/hr/ft (atts/m) 311 (299) 340 (327) 360 (346) 369 (355) 442 (425) 311 (299) Conventional Btu/hr/ft (atts/m) 320 (308) 350 (337) 370 (356) 380 (365) 455 (438) 320 (308) Fan Speed 6 IDD6SU6 (10.3 ) 1200 6 1200 6 1200 6 1200 6 1200 6 1200 6 IDD6SU4, 8, 12 (10.3 ) 1200 6 1200 6 1200 6 1200 6 1200 6 1200 6 Notes: 1. All data based on store temperature and humidity that does not exceed NSF Type 1 ambient conditions of 75 F and 55% relative humidity except where noted. 2. Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. 3. Hussmann Peg Shelves for Dairy/Deli applications only. 4. Data for operation in NSF Type 2 ambient of 80 F and 55% relative humidity. 5. AHI 1200 ating Point for energy consumption comparison only. 6. Some lengths and/or applications require optional fan speed control kits applied by the Hussmann Product Configurator. Defrost Data Type 1 Frequency (hours between defrost) Harsh 24 12 Environment Offtime Time (minutes) 40 30 Electric or as Not Available Defrost ater 7 1.5 lb/ft/day 2.3 lb/ft/day (2.2 kg/m) (3.4 kg/m) 7 (± 15% based on case confi guration and product loading). Conventional Controls IDD6SU Low Pressure Backup Control CI/CO 8 26 F / 16 F 3.3 C / 8.9 C Indoor Unit Only, Pressure Defrost Termination 8 48 F (8.89 C) 8 Use a Temperature Pressure Chart to determine PSI conversions. Estimated Charge 9 IDD6SU 4 ft 0.7 lb 11.2 oz 0.3 kg 6 ft 1.2 lb 19.2 oz 0.5 kg 8 ft 1.6 lb 25.6 oz 0.7 kg 12 ft 3.1 lb 49.6 oz 1.4 kg 9 This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound. Product Data ross efrigerated Volume 10 (Cu Ft/Ft) AHI Total Display Area 11 (Sq Ft/Ft) Shelf Area 12 (Sq Ft/Ft) 13.2 ft 3 /ft (1.23 m 3 /m) 5.36 ft 2 /ft (1.63 m 2 /m) 11.69 ft 2 /ft (3.56 m 2 /m) 10 AHI ross efrigerated Volume: efrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 11 Computed using AHI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 12 Shelf surface area is composed of bottom deck plus standard shelf complement for this model: (5) rows of 22-in. shelves 2 of 12 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 IDD6SU Merchandiser Data Sheet

Insight Multideck Merchandiser, EcoVision Doors, 6 Display Levels, Standard Bottom, Ultra Low Height Front Insight IDD6SU Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE 2017 energy efficiency standards. Shelf complement shown as tested: Five rows of 22-in. shelves spaced equally between bottom display pan and interior top panel. IDD6SU Dimensions shown as in. and (mm). 1 1/2 in. (38 mm) equired Air ap 43 7/8 (1114) Other optional kits (top piping and vent fans) add to the overall case height. A minimum 1 1 /2-in. clearance required to remove raceway cover, 6 1 /2-in. for full access. See the Installation manual for instructions. Door Opening 64 1/4 (1632) 10 1/2 (267) LOAD LIMIT LINE 70 3/8 (1788) 90 7/8 (2308) 3-in. between back to back cases. Shown with Ellipse Option Canopy and Bumper. 29 7/8 (759) C O I L A L L 15 3/8 (391) 11 1/8 (283) FANS 2 5/8 (67) 29 (737) 22 5/8 (575) 33 1/2 (851) NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials and cleanability. 43 1/2 (1105) 35 1/2 (902) P/N 0550565_L HUSSMANN COPOATION BIDETON, MO 63044-2483 U.S.A..HUSSMANN.COM 3 of 12

Engineering Plan View ANIN: Floor Drain must be located within 24 inches of aste Outlet. See page 5 for Drain Extension Option (must be used with hub-style floor drains). Dimensions shown as in. and (mm). IDD5SU/IDD6SU A 1 1/2 Inch (38 mm) equired Air ap 7 (178) 7 (178) F 3 5/8 (92) 44 7/8 (1140) 18 (457) B efrigeration Outlet 8 1/2 (216) C aste Outlet B efrigeration Outlet 29 (737) 33 1/2 (851) 35 1/2 (902) 43 1/2 (1105) 43 7/8 (1114) ireway in Canopy Splashguard Field Electrical Connection at TOP of Case D E Door Swing Clearance 22 5/8 (575) FONT (12 Foot Model shown above) eneral (A) Case Length (without ends or partitions) (Each end and insulated partition adds 1 1 /2 in. (38 mm) to case line up.) 4 ft 6 ft 8 ft 12 ft 48 1 /8 (1222) 72 1 /4 (1835) 96 1 /4 (2445) 144 3 /8 (3667) Maximum O/S dimension of case back to front (includes bumper) 43 1 /2 (1105) 43 1 /2 (1105) 43 1 /2 (1105) 43 1 /2 (1105) Back of case to front of splashguard 35 1 /2 (902) 35 1 /2 (902) 35 1 /2 (902) 35 1 /2 (902) (B) Distance between edges of external legs and center legs NA 29 (737) 41 (1041) 41 (1041) (C) Distance between edges of center legs 41 1 /8 (1045) NA NA 41 1 /8 (1045) Distance between front legs and splashguard 8 (203) 8 (203) 8 (203) 8 (203) Electrical Service (Field Electrical iring Connection) (D) H End of case to center of Field Electrical iring Connection (top of case) 39 3 /8 (1000) 63 1 /2 (1613) 87 1 /2 (2223) 135 1 /2 (3442) Back of case to center of Field Electrical iring Connection 18 (457) 18 (457) 18 (457) 18 (457) Length of electrical wireway 44 5 /8 (1133) 33 1 /2 (851) 45 7 /8 (1165) 45 7 /8 (1165) (E) H end of case to LH end of electrical wireway (top of case) 46 1 /2 (1181) 70 1 /2 (1791) 94 1 /2 (2400) 142 5 /8 (3630) aste Outlets (see page 5 for drain extension option) (F) H End of case to the center of waste outlet 24 1 /8 (613) 24 1 /8 (613) 24 1 /8 (613) 72 1 /4 (1835) Back O/S of case to center of waste outlet(s) 33 1 /2 (851) 33 1 /2 (851) 33 1 /2 (851) 33 1 /2 (851) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) Floor Drain must be located within 24 inches of aste Outlet. efrigeration Outlet () Back of case to center of refrigeration outlet 29 (737) 29 (737) 29 (737) 29 (737) End of case to center of refrigeration outlet 8 1 /2 (216) 8 1 /2 (216) 8 1 /2 (216) 8 1 /2 (216) 4 of 12 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 IDD6SU Merchandiser Data Sheet

aste Outlet Drain Extension Option Insight IDD6SU Drain Extension Option (Partial End View) Exterior front drain Elbow may require field cut to meet local code 1 (25) 3 (76) Floor drain Drain assembly can be supported if necessary IMPOTANT: If hub drain is used in lieu of flush floor sink, a drain extension kit must be installed. Hub drains must be located in front of the waste outlet to achieve adequate air gap. Engineering Plan View Dimensions shown as in. and (mm). A 1 1/2 Inch (38 mm) equired Air ap B 33 1/2 (851) 38 1/8 (968) 41 (1041) Interior case drain Exterior front drain & floor drain elocated Splashguard FONT (12 Foot Model shown above) aste Outlet Drain Option 4 ft 6 ft 8 ft 12 ft (A) H of case to center of interior case drain 24 1 /8 (613) 24 1 /8 (613) 24 1 /8 (613) 72 1 /4 (1835) (B) H of case to center of exterior front drain and floor drain 13 3 /4 (349) 13 3 /4 (349) 13 3 /4 (349) 61 7 /8 (1572) P/N 0550565_L HUSSMANN COPOATION BIDETON, MO 63044-2483 U.S.A..HUSSMANN.COM 5 of 12

Insight IDD6SU Electrical Data Number of Fans 4 ft 6 ft 8 ft 12 ft 10.3-in. 1 2 2 3 Amperes atts Evaporator Fan 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft 120V 60Hz Energy Efficient 0.40 0.80 0.80 1.20 24 48 48 72 230V 50/60Hz Energy Efficient 0.21 0.42 0.42 0.62 24 48 48 72 Minimum Circuit Ampacity 120V 60Hz Energy Efficient 0.60 1.00 1.00 1.40 230V 50/60Hz Energy Efficient 0.41 0.62 0.62 0.82 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 STANDAD LIHTIN Only lighting configurations that are compliant with the U.S. Dept. of Energy (DOE) 2017 regulation are available for sale for use in the U.S.A. STANDAD LIHTIN EcoShine II Canopy 1 ow EcoShine II 0.16 0.26 0.32 0.48 19.3 31.6 38.6 58.0 OPTIONAL LIHTIN EcoShine II Canopy 1 ow EcoShine II HO 0.22 0.33 0.44 0.66 26.5 39.5 53.0 79.4 Shelf None Mullion EcoShine II 60-in. 0.28 0.51 0.51 0.74 34.1 61.4 61.4 88.6 Frame Anti-Condensate Heaters (Only with EcoVision 0.41 0.63 0.68 0.94 55.5 82.3 88.1 120.8 HA+ Door Option) 120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting 230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52 6 of 12 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 IDD6SU Merchandiser Data Sheet

Insight IDD6SU ENDS or PATITIONS Each standard end and each insulated partition adds 1 1 /2 in. (38 mm) to case line up. Optional view end with end bumper adds 3 3 /4 in. (95 mm). PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Schedule 40 PVC Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 ESTIMATED SHIPPIN EIHT Case Solid End 4 ft 6 ft 8 ft 12 ft (each) lb (kg) 1030 (467) 1260 (572) 1490 (676) 1950 (885) 90 (41) Actual weights will vary according to optional kits included. Shelf Options Approved shelf sizes for standard (horizontal, 2-3 position brackets) displays: 18-inch 20-inch 22-inch 24-inch Contact engineering for non-standard (4 position brackets or other) display recommendations. Minimum number of Shelves: 4 Optimal number of Shelves: 5 Maximum number of Shelves: 8 Maximum number of Lighted Shelves: 0 Standard shelf complement for test purposes: (5) rows of 22-in. shelves evenly distributed vertically. P/N 0550565_L HUSSMANN COPOATION BIDETON, MO 63044-2483 U.S.A..HUSSMANN.COM 7 of 12

Insight IDD6SU eplacement Parts List Part # Description Part # Description Fan Assemblies 4 Ft, 6 Ft, 8 Ft & 12 Ft Standard HE Fan Assembly 0535564 10.3-in. Fan Assembly Thermostats Optional LED Fixtures and Power Supply Coils 0501213 Power Supply LED Canopy Fixture eplace with like fixtures. LED Mullion Fixture eplace with like fixtures. 0534331 4 ft, 8 ft, 12 ft (84 pass) 0534330 6 ft only (84 pass) Honeycomb - hite Other 0536831 4 ft, 8 ft, 12 ft 0536829 6 ft only 0534013 Fan Speed Selector (Standard) 0534355 Fan Speed Key 1200 PM Varies Thermo-expansion Valve EcoVision HA+ Frame Heaters (Optional) 4 Ft, 8 Ft & 12 Ft 0549867 Heater - Mullion End LH 0549870 Heater - Mullion Center 0548655 Heater - etainer Bottom 0549868 Heater - Mullion End H 6 Ft 0549867 Heater - Mullion End LH 0549869 Heater - Mullion Center 0548656 Heater - etainer Bottom 0549868 Heater - Mullion End H NOTE: For LED lighting parts contact your Hussmann service representative at 1-800-922-1919. Please have your model and serial number available. Descriptions including size and color are at http://www.hussmann.com/ en/products/led-lighting/pages/default.aspx. For additional parts information, visit http://www.hussmann.com/en/pages/aftermarket-parts.aspx 8 of 12 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 IDD6SU Merchandiser Data Sheet

Fan iring Offtime Defrost Insight IDD6SU Optional 120VAC Field Connection ND Fan Speed Selector 24VDC Positive () 24VDC Signal (O) 24VDC round () ND Connector Connector Connector Fan Motor Fan Motor Fan Motor 4-Ft 6-Ft & 8-Ft 12-Ft LED Canopy Light Circuits EcoShine II LED Canopy Lighting 1 ow Power Supply Case round Bar Orange or Tan Band 4-Ft Case Case round Bar Orange or Tan Band 6-Ft or 8-Ft Case LED Canopy Fixture LED Canopy Fixture LED Canopy Fixture Power Supply Case round Bar Orange or Tan Band 12-Ft Case Power Supply LED Canopy Fixture LED Canopy Fixture LED Canopy Fixture ANIN All components must have mechanical ground, and the merchandiser must be grounded. = ed Y = Yellow = reen = Blue = Black = hite = 120V POE = 120V NEUTAL = FIELD OUND = CASE OUND P/N 0550565_L HUSSMANN COPOATION BIDETON, MO 63044-2483 U.S.A..HUSSMANN.COM 9 of 12

Insight IDD6SU Mullion LED Lighting LED Power Supply 24VDC LED Power Supply 24VDC H LED Light LH LED Light LH LED Light CT LED Light H LED Light 4 Ft Case 6 Ft or 8 Ft Case LED Power Supply 24VDC LED Power Supply 24VDC LH LED Light CT LED Light 12 Ft Case CT LED Light H LED Light Door Frame Heater EcoVision HA+ Only ACEAY N T T FIELD IIN CONNECTIONS T (CANOPY AND S SHON TOETHE FO EFEENCE; BOTH MAY NOT BE ON CONFIUED CASE.) HEATE HEATE HEATE HEATE ETAINE HEATE ETAINE HEATE ETAINE HEATE 6 DOO (12 FT) ANIN All components must have mechanical ground, and the merchandiser must be grounded. = ed Y = Yellow = reen = Blue = Black = hite = 120V POE = 120V NEUTAL = FIELD OUND = CASE OUND 10 of 12 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 IDD6SU Merchandiser Data Sheet

Door Frame Heater EcoVision HA+ Only Insight IDD6SU ACEAY N T T FIELD IIN CONNECTIONS T (CANOPY AND S SHON TOETHE FO EFEENCE; BOTH MAY NOT BE ON CONFIUED CASE.) HEATE HEATE HEATE ETAINE HEATE ETAINE HEATE 3 DOO / 4 DOO (6 FT / 8 FT) ACEAY N T T FIELD IIN CONNECTIONS T (CANOPY AND S SHON TOETHE FO EFEENCE; BOTH MAY NOT BE ON CONFIUED CASE.) HEATE HEATE ETAINE HEATE 2 DOO (4 FT) ANIN All components must have mechanical ground, and the merchandiser must be grounded. = ed Y = Yellow = reen = Blue = Black = hite = 120V POE = 120V NEUTAL = FIELD OUND = CASE OUND P/N 0550565_L HUSSMANN COPOATION BIDETON, MO 63044-2483 U.S.A..HUSSMANN.COM 11 of 12

Insight IDD6SU Estimating efrigeration and Electrical Load (for comparison purposes only) Case Btu To determine Btu for a case, refer to the performance data chart on Page 2. Select lit or unlit shelves, then select the type of remote refrigeration system (parallel or conventional), which will give Btu/hr/ft. Multiply this number by the length of the case to determine Btu per hour. Add 10 BTU/H/FT for LED Mullion Lights. Case Electrical efer to store legend to determine number of circuits. Lighting should be specified in store legend. Fan electrical load for a case is computed by selecting the case length and fan voltage on Page 6. For example, a 12 ft case uses 3 fans. The store legend specifies fans on a 230V circuit. In this instance, fans use 0.62 Amps and the MCA is 0.82. hen applied, ambient fans, anti-sweat heaters, controllers, etc. must be included in the MCA. Include lights in the MCA if lights are on same circuit. Lights may be on a separate circuit. To estimate lighting load: select case length (12 ft), canopy lighting [standard or optional] (here 0.70 for standard), and mullion lighting [maximum for which case is wired] (0.74 for EcoShine II 60 mullion lights); then add together [0.48 + 0.74 = 1.22 amps for 120V] (for 230V, multiply 1.22 * 0.52 = 0.63). Line Sizing efer to store legend. Hussmann Line Sizing Charts are engineered for use with Hussmann refrigeration equipment. Scan Q code to access product information on your mobile device. evision History evision A: April 2015: Original Issue evision B: October 2015: Updated cover image and updated performance data on page 2. evision C: December 2015: Updated cross section and plan view. evision D: April 2016: Updated cover image, updated application data, updated cover image, added ross efrigerated Volume and updated plan view. evision E: June 2016: Updated cross section. evision F: August 2016: Updated cross section and plan view. evision : January 2017: emoved EcoShine Plus references. evision H: April 2017: Updated LED energy values. evision J: April 2017: Updated LED energy values. evision K: September 2017: Updated notes page. evision L: May 2018: Updated lighting information. 12 of 12 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 IDD6SU Merchandiser Data Sheet