Siemens Liquid Cooled Standby Generators

Similar documents
Siemens Liquid Cooled Standby Generators

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

Standby Generators. 70kW - Liquid Cooled Gas Engine. Meets 2010 EPA emissions regulations.

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

22 kva GENERAC STANDBY GENERATORS ISO. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES:

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

STANDBY GENERATOR 25 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 100 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 130 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Guardian Series. GUARDIAN SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Guardian Series INCLUDES:

Centurion Series. CENTURION SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Centurion Series INCLUDES:

Quietsource Series ISO. QUIETSOURCE SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Quietsource Series INCLUDES:

Standby Generators ISO FEATURES. Standby Generators Liquid-Cooled Gaseous Engine. Standby Generators INCLUDES:

Protector Series ISO FEATURES. Standby Generators Liquid-Cooled Gas Engine INCLUDES:

1P 120/240V, 3600 RPM,

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector Series

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector QS Series

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES INCLUDES:

22 / 27 / 32 / 38 / 48 kw

GENERAC GUARDIAN SERIES STANDBY GENERATORS

SPECIFICATIONS. Stationary Emergency Generator Specifications STATIONARY EMERGENCY GENERATOR COOLING SYSTEM FUEL SYSTEM ENGINE ELECTRICAL SYSTEM

20 kw GENERAC GUARDIAN SERIES STANDBY GENERATORS - PREPACKAGED. Air-Cooled Gas Engine Generator Sets FEATURES

16 kw CENTURION STANDBY GENERATOR. Air-Cooled Gas Engine Generator Sets FEATURES. INCLUDES: True Power Electrical Technology

7kW. 7kW. CorePower System Residential Standby Generators Air-Cooled Gas Engine FEATURES. Power Rating Model (Composite Polymer) - 7 kw 60Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

17 kw GENERAC GUARDIAN SERIES STANDBY GENERATORS - PREPACKAGED. Air-Cooled Gas Engine Generator Sets FEATURES

Protector Series ISO FEATURES. Diesel Generator Set INCLUDES:

16 kw CENTURION STANDBY GENERATOR. Air-Cooled Gas Engine Generator Sets FEATURES. Standby Power Rating Model (Steel - Gray) - 16 kw 60Hz

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

STANDBY GENERATORS 17 kw AIR-COOLED GENERATOR SETS

Protector Series ISO FEATURES. Diesel Generator Set. Protector Series INCLUDES:

Optimus Residential Standby Generators

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 70 kw 88 kva 60 Hz

SG L 35 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

8/10/14kW. 8/10/14kW. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES INCLUDES:

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 130 kw 163 kva 60 Hz

STANDBY GENERATOR 20 kw AIR-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model (Steel - Dark Gray) - 20 kw 60 Hz - US

SG L 50 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Spark-ignited generator set

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

20 KW / 25 KVA LIQUID COOLED POWERED by

G130LG2 6.8L. Industrial Spark-Ignited Generator Set. Codes and Standards. G130LG2 130 kw. Standby Power Rating 130 kw 163 kva 60 Hz

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

35kW ¹ STANDBY GENERATOR

SG L 300 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Spark-ignited generator set

48kW ¹ STANDBY GENERATOR

17/20kW. 17/20kW. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES. Includes: Standby Power Rating

SG L 250 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 150 kw 188 kva 60 Hz

Quiet Connect TM Series - RS13A, RS17A, RS20A, & RS20AC

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency POWERING AHEAD CODES AND STANDARDS

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

16/20/22 kw CENTURION SERIES

Quiet Connect TM Series - RS13A, RS17A, RS20A, & RS20AC

G150LG4 12.9L. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG4 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

RENTAL DIESEL GENERATOR SET

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

*Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

Rental Power 800 kw. Specification sheet. Description. Features. Options

DIESEL GENERATOR SETS

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 200 ekw 250 kva

Diesel generator set QSX15 series engine

Power Connect RX50. Series. Specification sheet. Features and benefits. Weight, size and sound level

STANDBY 200 ekw 250 kva

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Diesel generator set QSK23 series engine

9/11 kw. 9/11 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

MG L 150 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Diesel generator set 6BT5.9 series engine

DCA400SSI4F. WhisperWatt 400. MQ POWER Whisperwatt Series. Prime Rating 320 kw (400 kva) Standby Rating 336 kw (420 kva)

SG070. Industrial Gaseous Generator Set. SG070 70kW. primary codes and standards. Standby Power Rating 88kVA 70kW 60 Hz

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Diesel generator set QSB7 series engine

Residential Standby Generators

Power Connect TM Series RX60

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

G130LG. Industrial Gaseous Generator Set. G130LG 130kW. primary codes and standards. Standby Power Rating 163kVA 130kW 60 Hz

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

Transcription:

Data Sheet Siemens Liquid Cooled Standby Generars 80 kw Liquid Cooled Gas Engine Standby Power Rating 80 kw 60Hz Includes: Naturally Aspirated Gaseous Fueled 4.6L Engine Two line LCD tri-lingual digital Nexus controller Isochronous electronic governor Closed coolant recovery system Smart battery charger UV/Ozone resistant hoses ±1% voltage regulation Natural gas or LP operation 2 year limited warranty UL 2200 Listed Meets EPA emission regulations Catalog Numbers: SGN080RGA / SGN080RPA 120/240V, 1-phase SGN080CGA / SGN080CPA 120/208V, 3-phase SGN080JGA / SGN080JPA 120/240V, 3-phase SGN080IGA / SGN080IPA 277/480V, 3-phase Meets 2010 EPA emissions regulations. Does not meet CARB/EPA requirements for CA and MA. Features Total commitment component testing, reliability testing, environmental testing, destruction and life testing, plus testing applicable CSA, NEMA, EGSA, and other standards. Test criteria: - Protype tested - NEMA MG1-22 evaluation - System rsional tested - Mor starting ability Solid-state, frequency compensated voltage regulation This state-of-the-art power maximizing regulation system is standard on all Siemens models. It provides optimized fast response changing load conditions and maximum mor starting capability by electronically rquematching the surge loads the engine. An unequalled ±1% voltage regulation. usa.siemens.com/generars

Application & Engineering Data Generar Specifications Type Ror insulation Star insulation Synchronous Class H Class H Telephone interference facr (TIF) <50 Alternar output leads 3 phase Bearings Coupling Load capacity (standby rating) Exitation system Voltage Regulation Type Sensing 6 / 4 wire Sealed Ball Flexible Disc 80 kw Brushless Full Digital Three Phase Regulation ± 1% Generar Features Revolving field heavy duty generar Directly connected the engine Operating temperature rise 120 C above a 40 C ambient Insulation is Class F rated at 130 C rise All models are fully protyped tested Enclosure Features Aluminum weather protective enclosure Enclosed critical grade muffler Small, compact, attractive Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability. Quiet, critical grade muffler is mounted inside the unit prevent injuries. Makes for an easy, eye appealing installation. Rating definitions Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271). Engine Specifications Make Model Generac V-type Cylinders 8 Displacement 4.6 Liter Bore 3.55 Stroke 3.54 Compression ratio 9.4:1 Intake air system Valve seats Lifter type Governor Specifications Type Frequency regulation Naturally Aspirated Hardened Hydraulic Electronic Isochronous Steady state regulation ± 0.25% Engine Lubrication System Oil pump Oil filter Crankcase capacity Engine Cooling System Type Water pump Gear Full flow spin-on cartridge 6 Quarts Closed Belt driven Fan speed 1600 Fan diameter Fan mode Fuel System Fuel type Carburer Secondary fuel regular Fuel shut off solenoid Operating fuel pressure 26 inches Puller Natural gas, propane vapor Down draft 11-14 H 2 O Electrical System Battery charge alternar Static battery charger Recommended battery System voltage 12V 30 Amp 12V 2 Amp Group 24F, 525CCA 12 Volts 2

Operating Data KW rating (LP/NG) 80 Engine size 4.6 Liter, V8 Catalog Numbers Generar Output Voltage/kW - 60Hz kw AMP CB Size SGN080RGA/SGN080RPA 120/240V, 1-phase, 1.0 pf 77 320 400 SGN080CGA/SGN080CPA 120/208V, 3-phase, 0.8 pf 80 278 300 SGN080JGA/SGN080JPA 120/240V, 3-phase, 0.8 pf 80 249 300 SGN080IGA/SGN080IPA 277/480V, 3-phase, 0.8 pf 80 120 150 Engine Fuel Consumption (Natural Gas) (Propane) Natural Gas (ft 3 /hr.) (gal/hr.) Propane Exercise cycle 131 1.45 53 25% of rated load 312 3.45 126 50% of rated load 600 6.64 241 75% of rated load 835 9.25 336 100% of rated load 1154 12.78 465 For Btu content, multiply ft3/hr x 2520 (LP) or ft3/hr x 1000 (NG) Engine Cooling Air flow (inlet air including alternar and combustion air) ft 3 /min. 5300 System coolant capacity US gal. 4.0 Heat rejection coolant BTU/hr. 316,000 Max. operating air temp. on radiar C ( F) 60 (150) Max. ambient temperature C ( F) 50 (140) Combustion Air Requirements Flow at rated power 60 Hz cfm 250 cu ft/hr Sound Emissions In DBA Exercising at 7 meters 64 Normal operation at 7 meters 74 Exhaust Exhaust flow at rated output 60 Hz cfm 720 Exhaust temp. at muffler outlet C ( F) 449 (840) Engine Parameters Rated synchronous RPM 60 Hz 3600 Power Adjustments For Ambient Conditions Temperature deration Altitude deration 3% for every 10 C above - C 25 1.65% for every 10 F above - F 77 1% for every 100 m above - m 183 3% for every 1000 ft. above - ft. 600 RATING: All three phases units are rated at 0.8 power facr. All single phase units are rated at 1.0 power facr. STANDBY RATING: Standby ratings apply installations served by a reliable utility source. The standby rating is applicable varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject change without notice. kw rating is based on LPG Fuel and may derate with natural gas. 3

Interconnections Interconnections SGN SERIES ENGINE GENERATOR CONNECTION PANEL SL TRANSFER SWITCH Circuit breaker wire and conduit size Circuit breaker wire and conduit size kw kw Volts Volts CB Amps CB Amps Lug size Lug size 80 80 240 240 1 1 Ø 400 400 (1) (1) 600 600 mcm mcm #4 #4 or or (2) (2) 1/0 1/0 250 250 mcm mcm 1/0 1/0 80 80 240 24033 Ø 300 300 (1) (1) 600 600 mcm mcm #4 #4 or or (2) (2) 1/0 1/0 250 250 mcm mcm 1/0 1/0 80 80 208 20833 Ø 300 300 (1) 600 mcm #4 or or (2) (2) 1/0 1/0 250 250 mcm mcm 1/0 1/0 80 80 480 4803 Ø 150 #6 300 mcm 4

Nexus Control Features 2-line plain text LCD display Mode Switch -Au -Off -Manual/Test (start) Programmable start delay between 10-30 seconds Engine start sequence Engine warm-up Engine cool-down Starter lock-out Smart battery charger Aumatic voltage regulation with over and under voltage protection Aumatic low oil pressure shutdown Overspeed shutdown High temperature shutdown Overcrank protection Safety fused Failure transfer protection Low battery protection Simple user interface for ease of operation Aumatic start on utility failure. 7 day exerciser Sps unit. Power is removed. Control and charger still operate. Start with starter control, unit stays on. If utility fails, transfer load takes place. Cyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration) 5 seconds 1 minute Starter cannot re-engage until 5 sec. after engine has spped., 72Hz 50 event run log Future set capable exerciser Incorrect wiring protection Internal fault protection Common external fault capability Governor failure protection *Single and three phase connections may vary, refer the owner s manual for specific connection information. 5

6 Installation layout - Liquid Cooled Standby Generar 80kW Siemens Industry Inc. Building Technologies Division Standby Power Systems Catalog Numbers: SGN060RGST, SGN060RPST, SGN080RGA, SGN080RPA, SGN080CGA, SGN080CPA SGN080JGA, SGN080JPA, SGN080IGA, SGN080IPA Warning: Installation drawing for reference only. Liquid cooled units should be installed by an Authorized Siemens Standby Generar Contracr.

Notes: 7

Published by Siemens 2017 Siemens Industry, Inc. 5400 Triangle Parkway Norcross, GA 30092 1-800-241-4453 info.us@siemens.com Order No. RPFL-QT080-1117-CP Printed in USA All Rights Reserved 2017, Siemens Industry, Inc. usa.siemens.com/generars The technical data presented in this document is based on an actual case or on as-designed parameters, and therefore should not be relied upon for any specific application and does not constitute a performance guarantee for any projects. Actual results are dependent on variable conditions. Accordingly, Siemens does not make representations, warranties, or assurances as the accuracy, currency or completeness of the content contained herein. If requested, we will provide specific technical data or specifications with respect any cusmer s particular applications. Our company is constantly involved in engineering and development. For that reason, we reserve the right modify, at any time, the technology and product specifications contained herein.