Injection valve Type TXI 2

Similar documents
Injection valve, type TXI 2 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Expansion valves - 2 of 2

Thermostatic expansion valves PHT

Stainless steel - the strong solution

Thermostatic expansion valves Type TGE 10, TGE 20 and TGE 40

Thermostatic expansion valves type TGE 10, TGE 20 and TGE 40

Automatic controls catalogue E.N. 4

Technical leaflet Thermostatic expansion valves with fixed orifice

Thermostatic Expansion Valve

DANFOSS. Thermostatic Expansion Valves. Nominal Capacity Ranges in TR for Range N -40 to 50 F R-12 R-22 R-410A R-134A R-404A/

Thermostatic expansion valves type TGE 10, TGE 20 and TGE 40

Thermostatic Expansion Valve

Capacity regulators (hot gas bypass) PMC and CVC

Thermostatic Expansion

Crankcase pressure regulator Type KVL

Pressure and temperature regulators, type PM, and pilot valves

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

Crankcase pressure regulator Type KVL

Solenoid valve Types EVR 2 EVR 40 NC/NO

BITZER Liquid Injection Guidelines for CSH Compressors

Crankcase Pressure Regulating Valves

Solenoid valve for R410A and R744 Types EVR 2 - EVR 6 and EVRH 10 - EVRH 40

Oil separator Type OUB

Technical Information

Solenoid valves Type EVU for fluorinated refrigerants

Air-to-water heat pump for indoor installation - LIK 8TES. Spare parts list

Crankcase pressure regulator Type KVL

Thermostatic Expansion

Electric Expansion Valve Type AKVO 10

The precise step to take

Thermo -Expansion Valves Series TX7

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Modulating liquid level regulators, direct-controlled SV 1 and SV 3

Pressure operated water valve Type WVFX and WVS

Selection & Application Guidelines Performer scroll compressors in parallel installation

Thermostatic and Automatic Expansion Valves

Solenoid valves type EVR 2 40 NC / NO

Parker TEV Model Visual

Variable speed application guidelines

TI Series - Thermo -Expansion Valves

Solenoid valves. Solenoid valves, type PKVD Solenoid valves, type EVR NC / NO

Pilot controlled servo valves Type ICS - Solenoid Valves Pressure Regulating Valves. Technical leaflet MAKING MODERN LIVING POSSIBLE

Reliable season change

CCMT - Electrically operated valves for transcritical and subcritical CO2

Danfoss Commercial Compressors Towards more eco-friendly commercial refrigeration systems

Solenoid valves Type EVU

Solenoid valves, type EVRA 3 40 and EVRAT REFRIGERATION AND AIR CONDITIONING. Technical leaflet

NOTE: If the HF body is stamped HFK, then the cage is replaceable. HF N E S C B 2 H C 5 FT 3/8 x 1/2 ODF S/T. Capacity Nominal Rating in Tons

Electric expansion valve Type ETS ETS 400

THERMOSTATIC EXPANSION VALVES

HFK. Balanced Port Thermo Expansion Valve Kits. Save Inventory $ and Valuable Truck Stock Space

Solenoid valves type EVSA 25 50

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20

Electric operated valves Type CCM for R744 / CO2

Electric expansion valve for R744 (CO 2 ) Type AKVH

Electronically operated expansion valve for CO 2 Type AKVH

SEMPELL TURBINE BYPASS VALVE MODEL 115 CHP

MAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING.

Condensed Catalog 410A January 2008

HGX6/ S Engine: V Y/YY -3-50Hz PW Refrigerant: R404A, R507

Technical Information

Electrically operated expansion valves, type ETS

REFRIGERATION STRAINERS

Pilot operated main valves for regulating pressure and temperature, type PM

MT/MTZ 50 Hz R22 R407C R134a R404A / R507

Pilot-operated servo valve Type ICS

Application Data CONTENTS. COMPRESSOR PHYSICAL DATA (Table 1) Table 1 Open-Drive Compressors

quality products for refrigeration and air conditioning products suitable for CFC, HCFC and HFC 2006 release PRODUCT HANDBOOK

Electric expansion valve Type ETS ETS 400

A/C System and Components Evaporator Condenser and Related Components 1

GEA Bock HC Compressors. Semi-hermetic Compressors for Hydrocarbons. engineering for a better world. GEA Refrigeration Technologies

Reliable season change

CHILLER START UP PROCEDURE FORM DOC. N (DOC.N BELOW TO BE RETURN TO AERMEC)

Selection & Application guidelines. Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING

TECHNICAL INFORMATION MANUAL

AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT

Electric expansion valves Type ETS 6

Pressure Control Type KPU

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

DIM Heating and Air Conditioning

Solenoid valves EVRA and EVRAT

TEST REPORT #67. Compressor Calorimeter Test of Refrigerant ARM-25 in a R-404A Reciprocating Compressors

R134a R134a R13. 4a R134a R134a R134

Thermostatic valve Type AVTA

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Liquid level control. Thermostatic liquid level regulators, type TEVA. High pressure float valve, type HFI

Integrated valves Series 3

Technical brochure Eliminator filter drier DCR - with replaceable solid core

Data sheet. Thermostatically operated cooling water valves Type FJVA. January 2000 DKACV.PD.500.B B0033

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

A full line of field-tested CO 2 controls, stocked for your convenience

Product Data Sheet HKK70VSD Revision 1 (Variant Code E)

Electronic suction modulating valves type KVS

Electric expansion valve stepper motor. Controller for elec. expansion valve Connector for controller expansion valve

WP92. Ultimate press. Ultimate press. 0.4 kw Full load

High Profile Evaporator

t EVAPORATOR PRESSURE REGULATING VALVES

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

VTZ variable speed Reciprocating compressors

Transcription:

Data sheet Injection valve Type TXI 2 The TXI2 is an injection valve for desuperheating in 2-stage refrigeration systems operating on R22/R407C and other similar refrigerants where the hot gas temperature and the intermediate pressure are the controlling variables. Application In principle there are two different ways in which to setup 2-stage refrigeration systems as far as temperature signal to the liquid injection valve is concerned. Danfoss DCS (sw) 2015.12 DKRCC.PD.AV0.A3.02 520H10558 1

Application examples Example 1 2-stage refrigeration system built up with a combined LP/HP compressor. In this case the discharge gas temperature on the HP side is used as temperature signal and the intermediate pressure as pressure signal to the injection valve. In this example a TXI 2 injection valve is used, see fig. 1. Fig. 1 LP: Low pressure HP: High pressure PI: intermediate pressure Application examples (continued) Example 2 2-stage refrigeration system with 2 separate refrigerating compressors in series. In this set up a solution with injection valve type TXI 2 can be used, because the discharge gas temperature on the HP side can be used as temperature signal and the inter mediate pressure as pressure signal to the injection valve, see fig. 2. Fig. 2 LP: Low pressure compressor HP: High pressure compressor PI: Intermediate pressure Example 3 Same setup as in example 2 with 2 separate refrigerating compressors in series. As in this setup there is an accessible control signal where there is correspondence between pressure and temperature, regulation of the strongly superheated condition of the refrigerant can be undertaken by a traditional thermostatic expansion valve e.g. Danfoss type TX 2 for R22/R407C refrigeration systems, see fig. 3. Fig. 3 LP: Low pressure compressor HP: High pressure compressor PI: Intermediate pressure Danfoss DCS (sw 2015.12 DKRCC.PD.AV0.A3.02 520H10558 2

Operation P bulb P spring Fig. 4 Danfoss 68-651.10 PI The valve function is controlled by the intermediate pressure (PI) acting under the diaphragm and the bulb pressure derived from the discharge gas temperature across the diaphragm (fig. 4). Danfoss DCS (sw 2015.12 DKRCC.PD.AV0.A3.02 520H10558 3

Operation (continued) The intermediate pressure (PI), setting spring and bulb temperature form a working range which, expressed in a co-ordinate system, makes up a working area, see fig. 5. Fig. 5 Valid for code no. 068-3249 only Fig. 5 Valid for code no. 068-3258 only Within the limits of this area, the working point required is found (PI/t bulb). The location of the working point depends on the spring force set and in addition to that dependent on the proportional band (the superheat) and the valve capacity (size of orifice). Therefore, the sizing is decisive for a satisfactory result. Danfoss DCS (sw 2015.12 DKRCC.PD.AV0.A3.02 520H10558 4

Sizing To size TXI 2 the refrigerating capacity required to remove the superheat at the intermediate stage must be known as well as the required discharge gas temperature on the discharge side. Besides this the pressure drop p across the injection valve must be determined as the difference between the condensing pressure and the pressure at the intermediate stage. With the values for the required capacity, the Example: Required refrigerating capacity Q = 5 kw Evaporating temperature at intermediate state t 0 = 25 C Pressure drop across TXI 2 p = 12 bar' Discharge gas temperature (HP) = 110 C evaporating temperature t 0 (PI) of the intermediate stage and the pressure drop across TXI 2, the correct orifice size can be determined. Evaporating temperature 25 C 2 4 6 8 10 12 14 16 TXI 2-0.2 00 0.69 0.83 0.94 1.02 1.08 1.12 1.14 1.15 TXI 2-0.3 01 1.21 1.51 1.71 1.85 1.96 2.04 2.09 2.11 TXI 2-0.6 02 1.66 2.13 2.42 2.62 2.77 2.87 2.94 2.97 TXI 2-0.8 03 2.98 3.82 4.33 4.69 4.96 5.15 5.27 5.33 TXI 2-1.2 04 4.36 5.59 6.35 6.89 7.30 7.60 7.80 7.91 TXI 2-1.5 05 5.55 7.10 8.06 8.74 9.26 9.64 9.89 10.02 TXI 2-2.0 06 6.80 8.68 9.84 10.67 11.30 11.77 12.08 12.25 TXI 2 with orifice 03 fits that example as the values in the capacity tables are shown with a proportional band of 6 K. Capacity in kw Evaporating temperature 10 C 2 4 6 8 10 12 14 16 TXI 2-0.2 00 0.79 0.96 1.1 1.2 1.2 1.3 1.3 1.3 TXI 2-0.3 01 1.6 2.0 2.3 2.5 2.6 2.7 2.8 2.8 TXI 2-0.6 02 2.2 2.9 3.3 3.6 3.8 4.0 4.1 4.1 TXI 2-0.8 03 3.9 5.1 5.9 6.4 6.8 7.1 7.3 7.3 TXI 2-1.2 04 5.8 7.6 8.7 9.5 10.1 10.5 10.8 10.9 TXI 2-1.5 05 7.4 9.6 11.0 12.0 12.8 13.3 13.6 13.8 TXI 2-2.0 06 9.1 11.8 13.5 14.7 15.6 16.2 16.6 16.8 Evaporating temperature 20 C 4 6 8 10 12 14 16 TXI 2-0.2 00 0.88 1.0 1.1 1.1 1.2 1.2 1.2 TXI 2-0.3 01 17 1.9 2.0 2.2 2.3 2.3 2.3 TXI 2-0.6 02 2.4 2.7 2.9 3.1 3.2 3.3 3.3 TXI 2-0.8 03 4.2 4.8 5.2 5.5 5.8 5.9 6.0 TXI 2-1.2 04 6.2 7.1 7.7 8.2 8.5 8.7 8.8 TXI 2-1.5 05 7.9 9.0 9.8 10.3 10.8 11.0 11.2 TXI 2-2.0 06 9.6 11.0 11.9 12.6 13.1 13.5 13.7 Danfoss DCS (sw 2015.12 DKRCC.PD.AV0.A3.02 520H10558 5

Capacity in kw Evaporating temperature (PI) 25 C 2 4 6 8 10 12 14 16 TXI 2-0.2 00 0.69 0.83 0.94 1.02 1.08 1.12 1.14 1.15 TXI 2-0.3 01 1.21 1.51 1.71 1.85 1.96 2.04 2.09 2.11 TXI 2-0.6 02 1.66 2.13 2.42 2.62 2.77 2.87 2.94 2.97 TXI 2-0.8 03 2.98 3.82 4.33 4.69 4.96 5.15 5.27 5.33 TXI 2-1.2 04 4.36 5.59 6.35 6.89 7.30 7.60 7.80 7.91 TXI 2-1.5 05 5.55 7.10 8.06 8.74 9.26 9.64 9.89 10.02 TXI 2-2.0 06 6.80 8.68 9.84 10.67 11.30 11.77 12.08 12.25 Evaporating temperature (PI) 30 C 4 6 8 10 12 14 16 TXI 2-0.2 00 0.79 0.90 0.96 1.0 1.1 1.1 1.1 TXI 2-0.3 01 1.4 1.5 1.7 1.8 1.8 1.9 1.9 TXI 2-0.6 02 1.9 2.2 2.7 2.5 2.6 2.6 2.7 TXI 2-0.8 03 3.4 3.9 4.2 4.4 4.6 4.7 4.8 TXI 2-1.2 04 5.0 5.7 6.2 6.5 6.8 7.0 7.1 TXI 2-1.5 05 6.4 7.2 7.8 8.3 8.6 8.8 9.0 TXI 2-2.0 06 7.8 8.8 9.6 10.1 10.5 10.8 11.0 Evaporating temperature (PI) 40 C 2 4 6 8 10 12 14 16 TXI 2-0.2 00 0.60 0.71 0.80 0.86 0.92 0.95 0.98 0.99 TXI 2-0.3 01 0.90 1.11 1.25 1.35 1.43 1.49 1.53 1.55 TXI 2-0.6 02 1.23 1.55 1.74 1.88 1.97 2.05 2.09 2.12 TXI 2-0.8 03 2.20 2.78 3.12 3.36 3.54 3.68 3.77 3.81 TXI 2-1.2 04 3.20 4.04 4.56 4.93 5.21 5.43 5.58 5.67 TXI 2-1.5 05 4.07 5.14 5.79 6.26 6.62 6.90 7.09 7.20 TXI 2-2.0 06 4.98 6.28 7.07 7.65 8.09 8.44 8.68 8.82 Danfoss DCS (sw 2015.12 DKRCC.PD.AV0.A3.02 520H10558 6

Setting TXI 2 cannot be set until the refrigerant system is started up. Setting after start-up is carried out when the discharge gas temperature has been recorded and the intermediate pressure is known or measured. By means of the diagram, fig. 5, the actual working point is found. From the location of the working point in the diagram, fig. 5, it should be decided whether to increase or decrease the spring force. Alteration of the spring from slack to tight setting corresponds to 6 revolutions of the TXI 2 setting screw. Technical data Perm. working pressure PS/MWP: 34 bar Capillary tube: 1.5 m. Ordering valve Type Connections [in.] Temp. range Pressure range (pi) Weight kg Code no. TXI-2 3 /8 1 /2 SAE flare +100 +130 C 0-2 bar 0.3 068-3249 TXI-2 3 /8 1 /2 SAE flare +100 +130 C 1-5 bar 0.3 068-3258 TXI-2 3 /8 SAE flare 1 /2 solder +100 +130 C 1-5 bar 0.3 068-3343 TXI-2 3 /8 1 /2 SAE flare +80 +110 C 1-5 bar 0.3 068-3360 Ordering accessories assembly no. Code no. TE 2 00 068-2003 01 068-2010 02 068-2015 03 068-2006 04 068-2007 05 068-2008 06 068-2009 Flare nuts Symbol Connection for copper tubing with outside cam. Reducer for copper tubing with outside diam. in. mm. in. mm. Code no. 1 /4 6 011L1201 3 /8 10 011L1235 1 /2 12 011L1203 3 /8 10 1 /4 6 011L1207 Danfoss DCS (sw 2015.12 DKRCC.PD.AV0.A3.02 520H10558 7

Dimensions and weight 97 Danfoss 68-652.10 9.8 Dimensions in mm Weight: 0.354 Kg Danfoss DCS (sw) 2015.12 DKRCC.PD.AV0.A3.02 520H10558 8