TECSUN (UL) PV1-F Halogen - free TÜV + UL dual rated PV-Wire

Similar documents
ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics

ENERGY. Solar Cables

Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region)

CLICK-FIT. High Voltage Accessories for Extruded Cables

20 HUBER+SUHNER RADOX SOLAR

DC Cabling Ready for 1,500 V DC

CABLES FOR A MOVING WORLD TRATOS RENEWABLE ENERGY. Mar 2010 Tt 11-14

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

Industry Cables Special cables for industrial applications General Catalogue


sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

Harnessing the wind of change. Our cables supply societies with renewable energy.

Technical attributes

ZHPCG CK0226 POWER CABLE WIRE & CABLE

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

14 HH EAC/CTP CE RoHS-II conform

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables


Data sheet chainflex CF270.UL.D

Any inquiries, please feel free to contact or Caledonian

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

Technical specifications

Data sheet chainflex CF210.UL

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

TRIFLEX H07RN-F CPR COMPLIANT REGULATION 305/2011/EU. Low voltage - Energy, cabling, signalling and control. reaction to fire

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

Global data. Electrical parameters

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

Data sheet chainflex CF6

Cables for Railway Technology

Data sheet chainflex CF310.UL

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

Data sheet chainflex CF10

Data sheet chainflex CF340

ÖLFLEX CLASSIC 110 H Info Benefits

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

OPTOFLEX G62,5/125: rubber cables with fiber optic

Data sheet chainflex CF140.UL

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

DNV-GL HH CE RoHS-II conform

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Data sheet chainflex CF8821

Type MMV-WP Medium Voltage Wind Power Cable

Cable systems We offer you the essential components for a future-oriented e-mobility.

RFOU 0.6/1kV Power Cable

Data sheet chainflex CF300.UL.D

Data sheet chainflex CF240

CF270.UL.D.

Data sheet chainflex CFSOFT1

Data sheet chainflex CF5

BFOU 0.6/1kV Power Cable

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

New TITANEX PREMIUM. No limit!

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

Data sheet chainflex CF886

Power & Control Cable IEC

Cables for cable carriers and reels SYSTEMS IN MOTION

RENEWABLE ENERGY. Alcan cable solutions

BlueLine Cables for Shipbuilding

Data sheet chainflex CF330.D

N2XY IEC XLPE PVC 0.6/1kV Cable

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

Cables and multistrand wires Main catalog. Cableline Test & Measurement

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

The cables you need when you need them

Data sheet chainflex CF130.UL

Data sheet chainflex CF881

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia


Data sheet chainflex CF885.PE

RADOX SOLAR. Edition 2014

Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

SAC-4P-M12MS/ 5,0-PUR SH

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

Data sheet chainflex CF886

Data sheet chainflex CF9

OHL AC Cable DC Cable Submarine

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

SECTORFLEX CABLE CATALOGUE

CRANE, CONVEYOR, LIFT & REELING CABLES

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

Mining and Petrochemical Tray-Rated Fiber Optic Cables

PUR c-track cables For highest requirements

TRATOS OIL&GAS NEK606

LS Total Solution for Photovoltaic

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Transcription:

TECSUN (UL) PV1-F Halogen - free TÜV + UL dual rated PV-Wire A brand of the

Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy and information as primary driver in the development of communities. With this in mind, we provide major global organisations in many industries with best-in-class cable solutions, based on state-of-the-art technology. Throught two renowned commercial brands - Prysmian and Draka - based in almost 100 countries, we re constantly close to our customers, enabling them to further develop the world s energy and telecoms infrastructures, and achieve sustainable, profitable growth. In our energy business, we design, produce, distribute and install cables and systems for the transmission and distribution of power at low, medium, high and extra-high voltage. In telecoms, the Group is a leading manufacturer of all types of copper and fibre cables, system and accessories - covering voice, video and transmission. Drawing on over 130 years experience and continuously investing in R&D, we apply excellence, understanding and integrity to everythings we do, meeting and exceeding the precise needs of our customers across all continents, at the same shaping the evolution of our industry.

What links sustainable ideas to real-world results? Cable solutions to enable the production and supply of renewable energy To meet an ever-growing need for power, the world is increasingly turning to renewable and sustainably sourced wind and solar energy. In response to this demand, Prysmian cables are helping businesses in the renewable industry around the globe convert these new opportunities into reality. Our technologies - which cover cables used in wind turbine and tower operations, submarine inter-array, platform connection and export cables to link the various turbines and underground power transmission and distribution cable system for wind power applications - are at work across the renewables sector, supporting the operations of turbine manufacturers, contractors and developers, grid operators, system integrators and panel makers. Always aware of our responsibility to the planet, we re constantly driving innovation in our industry, aiming to help renewable industry partners deliver projects with benefits for the future of both our world and their businesses.

Technical Data - TECSUN (UL) PV1-F Trademark Type designation TECSUN (UL) PV1-F PV-Wire PV1-F Photovoltaic Wire UL Category: ZKLA Approvals UL 4703 (PV-Wire), NEC NFPA 70 690.31A UL Certificate No. 011011-E312049 Meets TÜV 2 PfG 1169/08.2007 requirements for PV-Wire Certificate No. R 60039360 Application PRYSMIAN TECSUN (UL) PV1-F PV-Wire is intended for use in Photovoltaic Power Supply Systems: Indoor and/or outdoor, in industrial and agriculture fields. They are suitable for applications in/at equipment with protective insulation (Protecting Class II), in explosion hazard areas (PRYSMIAN Internal Testing) and may be installed as well as fixed or freely suspended or free movable. Installation in cable trays, conduits, on and in walls is available. TECSUN (UL) PV1-F PV-Wire is permitted for direct burial (UL 4703-4). Ratings Meets or exceeds the requirements of UL 4703 as well as TÜV 2PfG 1169/08.2007. Meets TÜV 2PfG 1169/08.2007: Rating from -40 C up to +90 C Max. Conductor Temperature +120 C Meets UL 4703: Rating 90 C Wet or Dry Operation Rating 105 C Dry Operation Electrical Parameters Rated Voltage (Uo/U) 600/1000 V AC per TÜV 2PfG 1169/08.2007 rating (U) 600 V AC per UL 4703 rating Maximum permissible operating voltage in 700/1200 V AC systems Maximum Permissible operating voltage in 900/1800 V DC systems Test voltage 6500 V AC / 15000 V DC / 5 min. Ampacity Meets requirements for PV-Wire per TÜV 2 PfG 1169/08.2007 Tests TÜV 2PfG 1169/08.2007 PRYSMIAN Internal Testing Meets HD 22.2 Conductor Resistance, Test Voltages AC and DC, Electric Strength, Surface Resistance, Spark Test on Insulation, EN 50305 Part 6 DC stability (10 days, 85 C, salt water, 900 V DC), Insulation Resistance at 20 C and 90 C in Water. Insulation Resistance at 120 C in Air. Relative Permittivity and Meets UL 2556 Section 6.5: εr 6 Stability Factor Meets UL 2556 Section 6.6: After 14 days < 1, Difference day 1 and day 14 < 0.5; Long Term Insulation In Water: 90 C 600 V (AC) per UL 2556 Section 6.4.4.2.1 3GΩ after 12 weeks Resistance In Air: 113 C 600 V (AC) per UL 2556 Section 6.4.4.2.2 3GΩ after 12 weeks Dielectric Withstand Per UL 2556 Section 6.2 Method 1 and UL 44 Table 42 and 43: 1.5-6 mm² 3.0 kv, 10-35 mm² 3.5 kv, 50-95 mm² 4.0 kv Thermal Parameters Ambient Temperature From -40 C up to +90 C (-40 F up to +194 F) for fixed and flexible installation Maximum permissible conductor operating temperature UL 4703 rating +105 C (+221 F) Dry Operation TÜV 2 PfG 1169/08.2007 +120 C (+248 F) per IEC 60216 permanent temperature for 20.000 h (= 2.3 years) at max. 90 C permanent temperature (= 30 years) Short-Circuit Temperature TÜV 2 PfG 1169/08.2007 +200 C (+392 F) for 5s PRYSMIAN Internal Testing +250 C (+482 F) for 5s Resistance to Cold UL 4703 Cold Bend Test at -40 C temperature (per UL 2556 Section 7.5) Flexibility at -40 C temperature per UL 1581 Section 583 TÜV 2 PfG 1169/08.2007 Cold Bend Test at -40 C temperature per DIN EN 60811-1-4 Impact Test at -40 C temperature similar to DIN EN 50305 Damp-Heat Test Meets TÜV 2 PfG 1169/08.2007 1000 h at 90 C and 85% humidity per EN 60068-2-78

Technical Data Mechanical Parameters Chemical Parameters TECSUN (UL) PV1-F Tensile Rating 15 N/mm² in operation, 50 N/mm² during installation per HD 516, DIN VDE 0298 Section 3 7.1 and Section 300 5.4.1 Minimum bending Radius min. 4 x D (D=Overall Cable Diameter) Abrasion Meets DIN EN 53516: against abrasive paper, (PRYSMIAN Internal Testing) Sheath against sheath, Sheath against metal, Sheath against plastics Shrinkage Test Meets TÜV 2 PfG 1169/08.2007 <2% per EN 60811-1-3 Pressure Test at High Meets TÜV 2 PfG 1169/08.2007 <50% per EN 60811-3-1 Temperature Dynamic Penetration Test Meets requirements for PV-Wire per TÜV 2 PfG 1169/08.2007 Shore-Hardness A 85 per DIN 53505 (PRYSMIAN Internal Testing) Deformation Pressure Head 9.5 mm Ø, 60 minutes, 131 C, 2000 g load per UL 2556 Section 7.7 Insulation Fall-In Meets UL 2556 Section 7.1 Durability of Print Test per UL 2556 Section 7.16 and UL 44 Section 5.2 Gnawer resistance Safety can be optimized by utilizing protective hoses and cables with spinning or braid metallic coatings Mineral Oil Resistance Meets UL 1581 Section 400.1, Requirements per UL 44 Table 20 Acid and Alkaline Resistance Meets TÜV 2PfG 1169/08.2007 7 days, 23 C (N-Oxalic Acid, N-Sodium Hydroxide) per EN 60811-2-1 Ammonia Resistance 30 days in Saturated Ammonia Atmosphere (PRYSMIAN Internal Testing) Weather resistance UL 4703 Meets UL 2556 Section 4.2.8.5: 300 hours Meets UL 44 Section 5.15.2: 720 hours TÜV 2PfG 1169/08.2007 Ozone resistance per DIN EN 50396 Test Type B, HD 22.2 Test Type B UV-Resistance per UL 1581 (XenoTest), ISO 48922 (Method A) and HD 605/A12.4.20 PRYSMIAN Internal Testing Absorption of Water (Gravimetric) per DIN EN 60811-1-3 Fire Behaviour UL 4703 Vertical Flame Test per UL 2556 Section 9.5 Horizontal Flame Test per UL 2556 Section 9.1 VW-1 per UL 1581 1061 TÜV 2PfG 1169/08.2007 Single Cable Flame Test per IEC 60332-1-2, DIN EN 60332-1-2 Halogen-free per IEC 60754-1 No Corrosivity per IEC 60754-2 PRYSMIAN Internal Testing Multiple Cable Flame Test per DIN EN 50305-910 Low Smoke Emission per IEC 61034, EN 61034 (Light Transmittance > 70%) Low Toxicity per DIN EN 50305, ITC < 3 Conductor Corrosion 7 days 121 C per UL 2556 Section 8.1 Enviromentally Friendly TECSUN (UL) PV-Wire complies with RoHS directives 2002/95/EG, 2005/69/EG and 2006/122/EG of the European Union Direct Burial Service Entrance Cable per UL 854: Section 23 Impact Test Section 24 Crushing Test Installation Conditions per VDE 0800 Section 174 5.4.2 and VDE 0891 Section 6 4.2 ratings.

TECSUN (UL) PV1-F Design features Type designation TECSUN (UL) PV1-F Conductor Electrolytic tinned copper, Class 5 in accordance with IEC 60228 Nominal Cross-Section #16 AWG to 3/0 AWG (from 1.5 mm² to 95 mm²) Insulation HEPR complying with UL 1581 Table 50.245, IEC 60502-1 Core Identification Natural Colour White Jacket Cross-linked EVA rubber complying with UL 1581 Table 50.245, DIN VDE 0282 part 1, HD 22.1 Insulation and Jacket are connected solidly (Two-Layer-Insulation) Jacket Colour Jacket Printing Black Typical: PRYSMIAN TECSUN (UL) PV1-F 4 mm² 0.6/1 kv TÜV-Zert. R60039360 E312049 (UL) PV- Wire 12AWG 600V 90C Wet or 105C Dry Sun Res -40C VW-1 Dir Bur [Meter Marking] [Batch Number] Jacket Printing Default: White Colour Red and Blue Printing optional

TECSUN (UL) PV1-F Selection and ordering data Nominal Order No. Conductor Overall Overall Approx. Minimum Maximum Current Permissible cross-section diameter diameter diameter net weight bending permissible carrying short circuit cable cable radius tensile capacity at current load ambient temperature 60 C Min.value Max.value (free in air) (1s) [mm] [mm] [mm] [kg/km] [mm] [N] [A] [ka] 1.5 mm²/16 AWG 20025133 1.6 5.3 5.7 43 21.2 23 30 0.19 2.5 mm²/14 AWG 20025135 1.9 5.6 6.0 54 22.4 38 41 0.32 4.0 mm²/12 AWG 20025134 2.4 6.1 6.5 71 24.4 60 55 0.50 6.0 mm²/10 AWG 20025136 2.9 6.6 7.0 91 29.6 90 70 0.76 10.0 mm²/8 AWG 20025137 4.0 8.3 9.0 150 33.6 150 98 1.26 16.0 mm²/6 AWG 20025458 5.5 10.0 10.7 223 39.6 240 132 2.01 25.0 mm²/4 AWG 20025459 6.4 11.3 12.0 315 44.8 375 176 3.15 35.0 mm²/2 AWG 20025460 7.5 12.3 13.0 413 48.4 525 218 4.41 50.0 mm²/1 AWG 20025461 9.0 14.8 15.5 593 59.2 750 276 6.30 70.0 mm²/2/0 AWG 20025462 10.8 16.6 17.3 794 66.4 1050 347 8.82 95.0 mm²/3/0 AWG 20025463 12.6 18.4 19.1 989 73.6 1425 416 12.0 1.5 mm²/16 AWG 20025133 1.6 5.3 5.7 43 21.2 23 30 0.19

Linking sustainable ideas to real world results Australia & New Zealand Phone: + 61 398 043 598 E-mail: mark.dabbs@prysmiangroup.com China Phone: +86 512 6578 8210 E-mail: henry.feng@prysmiangroup.com E-mail: harry.zhang@prysmiangroup.com Danubian Region Phone: +42 056 650 1509 E-mail: ludek.karasek@prysmiangroup.com Denmark Phone: +45 60 39 27 26 E-mail: jesper.steenstrup@prysmiangroup.com France Phone: +33 047 246 7302 E-mail: jeanpierre.bignaud@prysmiangroup.com Germany Phone: +49 303 675 4589 E-mail: dean.iwanow@prysmiangroup.com Italy Phone: +39 026 449 5328 E-mail: flavio.delfini@prysmiangroup.com South America Phone: +55 114 998 4170 E-mail: fernando.coelho@prysmiangroup.com Spain Phone: +34 685 484 426 E-mail: victor.romera@prysmiangroup.com Turkey Phone: +90 212 393 7710 E-mail: ilhan.ozturk@prysmiangroup.com UK Phone: +44 191 371 8609 E-mail: ewan.marshall@prysmiangroup.com USA Phone: +1 713-209-1070 E-mail: peter.dunn@prysmiangroup.com Prysmian Group Viale Sarca 222, 20126 Milan, Italy Email: marketing.energy@prysmiangroup.com www.prysmiangroup.com A brand of the