INSTALLATION INSTRUCTIONS SWITCH HOUSING SUPPLIED ONLY AS AN ASSEMBLY OF ENCAPSULATED SWITCH & LEADS. FLOAT SUPPLIED ONLY WITH ENCAPSULATED MAGNET.

Similar documents
SWITCH HOUSING SUPPLIED ONLY AS AN ASSEMBLY OF ENCAPSULATED SWITCH & LEADS. FLOAT SUPPLIED ONLY WITH ENCAPSULATED MAGNET.

MODEL L-8 HARWIL CORPORATION 541 KINETIC DRIVE, OXNARD, CA TEL: (805) FAX: (805)

MODEL Q-8 HARWIL CORPORATION 541 KINETIC DRIVE, OXNARD, CA TEL: (805) FAX: (805)

Model L-5 & L-5SS LIQUID LEVEL SWITCH. Specific Gravity Compensating

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

M-100 Adjustable flow switch with right-angle flow

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

BMRX Series ROTARY LEVEL CONTROL

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F

TKD Series 3-Way Automated Ball Valves Product Data Sheet. Body Material: PVC Size Range: 1/2" through 2"

M-50/55 Series. Fixed setting flow switch with in-line flow

Holley Accessory Drive Kit Part Number

Assembly Instructions. Holley Accessory Drive Kit Part Number

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

introduction VR Piston Check Valves Product Data Sheet

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Stealth Electronic Manual ZTM1010 Installation & Maintenance. For Oval Gear Meter Models:

For Hazardous Locations

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

L500 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

WEB CONTROL PRODUCTS

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

AEROMOTIVE Part # and F-Body Fuel System Kit INSTALLATION INSTRUCTIONS

ODYR-19-5 & SLX-19-5 DUAL, TRIPLE, or QUAD AIR PRESSURE GAUGE

Holley Accessory Drive Kit Part Number

Stealth Electronic Manual ZTM1015 Installation & Maintenance. For Oval Gear Meter Models:

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

MODEL 5120 Tire Repair Station

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

80PK-2A Type K Immersion Probe

HPI Cylinders. Manufacturers of Hydraulic & Air Cylinders Since 1946

JD 900F TILT SENSOR INSTALLATION

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

EQUIVALENT BASIC CIRCUIT

introduction < STANDARDS >

INSTALLATION AND OPERATION MANUAL

ODY-19-1 AIR PRESSURE GAUGE

Switch Pro w/ Compact Junction Box A_1_ Series Owner s Manual

SOLAR DASH CHARGING SYSTEM USER GUIDE

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

AEROMOTIVE Part # & Generic Fuel System Kit INSTALLATION INSTRUCTIONS

L312 LIQUID LEVEL FLOAT SWITCH. Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

NBK-M - Economical Level Indicator

Power Float Manifold. Installation and Operations Manual Module 11A

Parts Manual Vermeer/ McLaughlin V750 Vacuum Machine (Serial #7G G )

Parts Manual Vermeer/ McLaughlin Mud System 230P

TBM Series 3-Way Ball Valve

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

ISTEC MAGNETIC METERS

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

introduction FE Series Butterfly Valves Product Data Sheet

Holley A/C Bracket System Part Number

I N S T R U C T I O N M A N U A L

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

QSI (Q-Star) Electronics Owner s Manual

Parts Manual Vermeer/ McLaughlin Mud System 230P

MODEL 900 IMPELLER-TYPE FLOW METER

1000 Series Piston Type Differential Pressure Gauges

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

A5000GEC-24VDC ZERO SPEED SWITCH

AEROMOTIVE Part # Street Rod Fuel Pump System INSTALLATION INSTRUCTIONS

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )

Installation and Operating Manual

Female Plug. connecting to Fuel Quantity

MODEL 200 MULTI-JET FLOW METER

Models P420A-3100 & P420A-5100

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Schmidt Mess- und Regeltechnik

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

AEROMOTIVE Part # & ½ L DOHC Return Style Fuel System Kit INSTALLATION INSTRUCTIONS

KOBOLD DF-MA Flow Transmitter. User Instructions

NOVALYNX CORPORATION MODEL 200-WS-02F WIND SPEED & DIRECTION SENSOR INSTRUCTION MANUAL

Installation, Operating and Maintenance instructions for Hydro-Air pumps

A Member of the. Integrated Metering Technologies

AEROMOTIVE Part # Mustang 5.0L Fuel System Kit INSTALLATION INSTRUCTIONS

Single Post Caliper Brake VC500

Positive Displacement Flowmeters GM007 series instruction manual

AUTOMATION. Operator s Manual. NLS Series. Pneumatic Level Sensors. Rev. A1, 4/07

Inline & 90 Live Swivels Fax:

idrive Power Cord Extender Installation Instructions MODELS: 3960M/3961S (1) 25 POWER CORD DRILL WITH 3/32 DRILL BIT

Lint Slide Grid Moist Air Applicator

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

INSTRUCTIONS. Owner's Manual. Ionizing Air Nozzles Models AN-2 and AN-6

Positive Displacement Flowmeters GM020 series instruction manual

SERIES 1000 ELECTRIC ACTUATORS

Transcription:

INSTALLATION INSTRUCTIONS SWITCH HOUSING, L-40N NORYL (PPO) SWITCH HOUSING, L-40VCR FORTRON (PPS) CERAMIC MAGNET BUSHING, L-40N NORYL (PPO) L-40VCR FORTRON (PPS) LEADS 24 LONG OR LONGER REED SWITCH FLOAT, L-40N NORYL (PPO) FLOAT, L-40VCD FORTRON (PPS) PIVOT PIN, L-40N, 316 STAINLESS PIVOT PIN, L-40VCR, HASTELLOY C PIVOT PIN, (TITANIUM OR TEFLON OPTIONAL) SWITCH HOUSING SUPPLIED ONLY AS AN ASSEMBLY OF ENCAPSULATED SWITCH & LEADS. FLOAT SUPPLIED ONLY WITH ENCAPSULATED MAGNET. PARTS LIST LIQUID LEVEL SWITCH ULTRA RELIABLE SINCE 1956 P. 1

SPECIFIC GRAVITY COMPENSATING MODEL L-40N/SG ALSO AVAILABLE Customer specified specific gravity sensitivity. Unique design enhances specific gravity sensitivity. Applications include fuel/water detection, oil/water detection, or detection of ground water contamination. SAmPLE PArT NumbEr OPTION 1: L-40N / NO / HOr / 316 BASE MODEL SWITCh OPERATION MOUNTING POSITION PIVOT PIN MATERIAL INDuCTIvE LOADS Switch contacts have been tested with small relays and 30A J-C relay inductive driving coils at 120/240VAC to 500,000 operations without failure. Steady state driving coil Volt/Amp rating should be 8VA or less. Dry CIrCuIT OPErATION Switch can interface with microprocessor based controllers and related computer circuits. NOTE: Model L-40 employs magnetic coupling between float arm and switch body. Magnetic particles can accumulate on and around magnetic housing which may affect proper operation. Please conduct appropriate fluid magnetic particle evaluation and operational tests prior to and during installation and use. model TECHNICAL SPECIFICATIONS L-40N L-40vCr ELECTrICAL (reed) SwITCH CHArACTErISTICS SPNO Contact Ratings: AC Voltage (max. switching) 300VAC DC Voltage (max. switching) 350VDC Current (max. switching) 0.5A Current (max. carrying) 2.5A Power (max) (VA, W) 50 watts Contact resistance (max. initial) 0.15 ohms Insulation resistance 10 10 ohms Operating temperature -40 F 240 F (-40 C 115 C) OPTIONAL: SPNC or SPDT, 3 watt, 100VAC/VDC. HySTErESIS ( LIquID LEvEL TO ACTIvATE/DEACTIvATE SwITCH) 3/8" (0.375") max. travel L-40n (noryl) working FLuID SPECIFIC GrAvITy: Top Mount: 0.8 Side Mount: 0.7 working PrESSurE: 200 psi max. continuous working TEmPErATurE: 180 F max. continuous. wetted materials: Body, Float and Bushing: Noryl (PPO) (10% glass fibers) Pivot Pin: 316 stainless steel L-40vcr (fortron) working FLuID SPECIFIC GrAvITy: Top Mount: 0.9 Side Mount: 0.7 working PrESSurE: 200 psi max. continuous working TEmPErATurE: 200 F max. continuous. wetted materials: Body, Float and Bushing: Fortron (PPO) (40% glass fibers) Pivot Pin: hastelloy C INSTALLATION DImENSIONS 1 8 FINGERTIGHT 15 16 213 16 MAX 113 16 0.5 3 8 1.35 7 16 17 8 ACROSS FLATS 7 16 111 16 35 8 13 32 59 16 15 32 ½ NPT 1¼ NPT or 1 NORYL OR FORTRON BUSHING 0.25 NPT P. 2 ULTRA RELIABLE SINCE 1956

INSTALLATION INSTRUCTIONS NOTE: Models L-40N and L-40VCR are dimensionally equal and employ the same electrical switch. The only difference between them lies in the materials used, which effects their chemical resistance. Installation procedures and electrical check out are equivalent, so the term Model L-40 will be used herein to mean both individual models L-40N and L-40VCR. Model L-40 liquid level switch is supplied with a 1¼ x ¼ NPT TT bushing, which allows the unit to pass through a 1¼ NPT female thread, located in the side or top of a tank. Teflon tape is factory applied to the ¼ NPT end of the switch housing, which is threaded into the 1¼ x ¼ bushing and tightened to provide a sealed connection. A mark on the top of the 1¼ x ¼ bushing indicates the plane of motion of the float. Horizontal mounting through the side wall of the tank. A. The male 1¼ NPT thread of the 1¼ x ¼ bushing is Teflon taped at the factory. Inspect the taped threads for uniform tape covering. If the Teflon tape has been damaged, remove and replace with new tape. B. Insert Model L-40 through the 1¼ NPT opening in the wall of the tank, thread the 1¼ x ¼ bushing into place, and tighten until seal is obtained, as per standard PVC pipe fittings. Tighten additional amount until this mark is at the top of the bushing. C. Model L-40 is designed to be field replaceable for donut sliding float types with ¼ NPT on end of the switch housing tube. Installation is accomplished as follows: 1. Disconnect the old sliding float switch wires and unthread the unit from the support (e.g. 2 flange, bushing, etc.) 2. Clean the female threads, apply Teflon tape to the L-40 threads as required, and tighten them in place as required to ensure a proper seal. 3. Move the L-40 float through the full travel to ensure float motion is not restricted by adjacent structures. Mark the outside surface of the flange, bushing, etc. to indicate the plane of motion and up position of the float. DIRECTION OF MOTION OF FLOAT UP MARK DOWN (GRAVITY) ELECTRICAL LEADS TYPICAL 2 FLANGE ULTRA RELIABLE SINCE 1956 P. 3

Vertical mounting through top of tank. A. Same as A) on previous page. B. Insert Model L-40 through the 1¼ NPT opening in the top of the tank, thread the 1¼ x ¼ bushing into place and tighten it until seal is obtained as per standard PVC pipe fittings. Arrow indicates the plane of motion of the float, which may be in any position or a particular position should internal structure interfere with motion of the float. C. Field replacement of top mounted donut -type sliding float level switches is the same as C) on the previous page, except that indexing the plane of motion of the float is not required except when tank internal structure interferes with float motion. ELECTRICAL WIRING Check switch operation with an ohmmeter prior to installing to insure switch is activated when float is moved between stops. NOTE: Switch must be activated and deactivated when float is in a position near but not at stop. VERTICAL MODE (NORMALLY OPEN) HORIZONTAL MODE (NORMALLY OPEN) FLOAT ON TOP CLOSED DRY TANK OPEN WET TANK NOTE: Normally closed switch is available. WHEN MOUNTED IN THE HORIZONTAL MODE, THE SWITCHING LOCK IS REVERSED BY MOUNTING FLOAT ON TOP OF SWITCH TUBE OR ON BOTTOM OF SWITCH TUBE FLOAT ON BOTTOM PLASTIC OR METAL ¼ NPT VARIABLE LENGTH SWITCH SUPPORT TUBE STANDARD JUNCTION BOX P. 4 ULTRA RELIABLE SINCE 1956

# PART NAME QTY PART # 1. FLOAT (SONIC WELD) - NORYL (1) 40100 (N) - FORTRON 40201 (VCR) #A MAGNET INSIDE (1) 40112 (N) 2. SWITCH HOUSING - NORYL ASSEMBLY ONLY (1) 40102 (N) - FORTRON 40202 (VCR) 3. BUSHING - NORYL (1) 40103 (N) - FORTRON 40203 (VCR) 4. PIVOT PIN - 316 STAINLESS STEEL (1) 40104 (N) - HASTELLOY C 40301 (VCR) 5. LEAD WIRE (OPTIONAL) (NORM CLOSED) CLOSED SWITCH - ASSEMBLY ONLY (1) 40105 #A BLUE WIRE - SHORT (1) 40106 #B BLUE WIRE - LONG (1) 40107 #C BLACK SHRINK TUBING (1) 901-F #D REED SWITCH - (NO) (1) 40108 # PART NAME QTY PART # 6. LEAD WIRE (OPTIONAL) (NORM OPEN) OPEN SWITCH - ASSEMBLY ONLY (1) 40109 #A BLUE WIRE - SHORT (1) 40106 #B BLUE WIRE - LONG (1) 40107 #C BLACK SHRINK TUBING (1) 901-F #D REED SWITCH - (NC) (1) 40108 #E SQUARE MAGNET (1) 40110 #F CLEAR SHRINK TUBING (1) 40111 7. LEAD WIRE (OPTIONAL) (SPDT) (3 WIRES) SPDT SWITCH - ASSEMBLY ONLY (1) 40113 #A GREEN WIRE - COMMON (1) 40114 #B BLACK WIRE - NORMALLY OPEN (1) 40115 #C WHITE WIRE - NORM CLOSED (1) 40116 #D BLACK SHRINK TUBING (2) 901-F #E BLACK SHRINK TUBING (1) 901-G #F REED SWITCH - SPDT (1) 40117 3 5 1 2 7 6 4 ULTRA RELIABLE SINCE 1956 P. 5

CERTIFICATE OF CONFORMANCE All HARWIL Corporation ( HARWIL ) products are manufactured using new materials and components. Our products meet the applicable performance and materials specifications indicated in our current Specifications Sheets and Parts Lists. HARWIL endeavors to obtain its materials and components from American Companies. DOMINANCE OF HARWIL LIMITED EXPRESS WARRANTY HARWIL warrants that all HARWIL products will be free from defects in material and workmanship for a period of one year from the date of original shipment. This warranty shall be limited to the replacement and reconditioning of our products and parts. HARWIL reserves the right and sole discretion to modify or change the composition, design and appearance of its products at anytime. This warranty shall be in lieu of all warranties of merchantability and of all warranties of fitness for a particular purpose relating to harwil products and parts. Buyer s sole remedy hereunto shall be replacement or reconditioning as set forth herein. HARWIL shall incur no obligations hereunder and no liability in the event of (a) buyer not fulfilling its responsibilities, including as set forth herein; (b) neglect, alteration or improper product use, including use with non-compatible devices or chemicals; or (c) repair by other than HARWIL. ANY LAWSUIT RELATING TO THIS WARRANTY MUST BE COMMENCED WITHIN ONE YEAR OF THE DATE IT ACCRUES. Each user of our product should make appropriate analysis and tests to determine the suitability of the product for the intended use prior to purchase. HARWIL provides no warranty and assumes no responsibility for corrosive attack on any material, component or design features associated with any of its products. Corrosion resistance information listed in HARWIL specification sheets, installation sheets and product brochures is solely for general background information. This table has been compiled from literature published by various material suppliers and by equipment manufacturers who use these materials in their products. Inasmuch as these data are based on tests by entities over which HARWIL has no control, HARWIL does not guarantee or accept responsibility for the accuracy of such tests. When using the table, please remember that in any given case several factors such as concentration, temperature, degrees of agitation and presence of impurities influence the rate of corrosion. The guide is intended, in a general way, to rate materials for resistance to chemicals which contain their usual impurities and for types of equipment in common use. Ratings should be used only as a general guide to first approximation of your material requirements rather than as the final answer. When in doubt, test materials before installation. After installation, follow up with preventative maintenance and periodic inspection. P. 6 ULTRA RELIABLE SINCE 1956 16306