ST3000 Ace Smart Transmitter Sanitary Differential Pressure / Pressure Transmitters

Similar documents
ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

Remote-sealed type of Differential Pressure Transmitters

Smart Valve explorer Smart Valve Positioner for Rotary Valve. Model SVX100 / SVX102

C S. Sanitary Differential Pressure Transmitter with Diaphragm Displacement Device CS Range Code. Accuracy. Note 1)

Smart Electromagnetic Flowmeter Detector for Sanitary use

Smart Valve Positioner 700 Series with HART Communication Protocol

Smart Valve Positioner 700 Series with HART Communication Protocol

Smart Pressure Transmitter

EDR-N8A CS Intelligent Absolute Pressure Transmitter STANDARD SPECIFICATIONS. Accuracy Material Code: Standard,316L Range Accuracy Code

Smart Displacement type Level Transmitter

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus

Smart Pressure Transmitter

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Electric Top-Guided Single-Seated Control Valves

Smart Pressure Transmitter

SATRON VTe pressure transmitter

C S. Differential Pressure Transmitter CS Range Code. Accuracy

Smart Pressure Transmitter

The Multivariable Air Flow Meter

Models SPG5A and SPG6A

The Multivariable Air Flow Meter

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

OM Field-Type I/P Converter Model : KUX113 User's Manual

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Piezoresistive single crystal silicon pressure transmitter

General Specifications

Temperature Indicating Controller

2-Color Display High-Precision Digital Pressure Switch

Pressure transmitter for industrial applications Type MBS 4510

Detector (for water measurement applications)

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Rosemount 3051CFA Annubar Flowmeter

SATRON VDt Differential Pressure Transmitter

Smart Valve Positioner for Rotary Valve

Safir-M digital. Features. LCD indicator and controls. Industries. Applications

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Top-Guided Single-Seated Control Valves

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Model 266HSH Gauge pressure transmitter low power consumption (1 to 5 V DC and HART)

2-Color Display High-Precision Digital Pressure Switch

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

CANADA SENSORS TECHNOLOGY INC.

Top-Guided Single-Seated Control Valves

SITRANS P measuring instruments for pressure

Modular Pharma Pressure Transmitter MPP

Series 10-ZSE40A(F)/10-ISE40A

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

UIB3351 Metal Capacitive Pressure/Differential Pressure Transmitters

Smart Valve Positioner 700 Series with FOUNDATION fieldbus

INTERNATIONAL METAL ENGINEERING

Special Purpose Transmitters

Pressure Transmitters for Sanitary Applications Model SA-11

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

압력트랜스미터 Model ADP9000 Series

Pressure Transmitter

Rosemount 3051T In-Line Pressure Transmitter

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

Compact Pressure Transmitter DAN-HH

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

Density Solution. TDF Series. Direct Insertion Density Meter. Characteristics

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

SATRON VT Pressure Transmitter

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

Rosemount 3051S Series of Instrumentation

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Technical specification

Smart Valve Positioner

Smart Valve Positioner 300 Series

2-Color Display Digital Pressure Switch

Smart ESD Device 700 Series for Safety Instrumented Systems (SIS) Model AVP77_/78_/79_

SVP3000 Alphaplus Smart Valve Positioner (Remote type)

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

Low Profile Insertion Vortex

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Metal tube variable area flowmeter for gases, liquids and steam

Smart Displacement type Level Transmitter SLX Series Model: SLX 110 / 120. User s Manual

SATRON VVFe Pressure Transmitter

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Low Differential Pressure Sensor ±1% F.S.

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

Ceramic Trim Angle Control Valves

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Pressure transmitters for industrial applications Type MBS 4510

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

Model HIT. Corrosion-Resistant PTFE Body Control Valves OVERVIEW SPECIFICATIONS. No. SS

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability

Differential pressure transmitter PASCAL Ci4 Delta P

CV3000 Series Pressure-Balanced Cage type Control Valve

Smart Valve Positioner 300 Series

Rosemount DP Level Transmitters and 1199 Seal Systems

Series Level-Trol Electronic Liquid Level Transmitters

Transcription:

ST3000 Ace Smart Transmitter Sanitary Differential Pressure / Pressure Transmitters Model JTC929A/JTC940A, JTE929A/JTE930A OVERVIEW The Food and beverage industry and fermentation industry require equipment which satisfy stringent sanitary standards for the safety of their respective products. ST3000 Ace sanitary differential pressure/pressure transmitters, which are equipped with micro-processors, meet sanitary standards plus maintain high reproducibility and precise accuracy. These transmitters utilize a sanitary clamp for process connection which conforms to the IDF (International Dairy Federation) standard and makes for easy installation and easy maintenance. By using a Smart Communicator, configuration of the transmitter (ranging, damping, output conformity, constant current output) and self-diagnostics are possible. FEATURES Model JTC929A/JTC940A Replaceable diaphragm structure The sanitary model JTC features a replaceable addon structure for its process interface. This allows a diaphragm to be quickly replaced. IDF conform process interfaces A 4S IDF clamp structure (Flush/Extended diaphragm) is employed for the process interface. Broad measuring ranges A broad range is covered by two models, the model JTC929A (2.5 to 100 kpa) and the model JTC940A (70 to 3500 kpa). Integral digital indicator (optional) The output can be checked in the field by using a digital indicator. Various process interfaces IDF 4S/3S 2S clamp structures and IDF 2S union nut structure are available for the process interface. Ambient temperature compensation function (PAT. 1978534) The ST3000 s ambient temperature compensation function calculates the specific gravity in regards to the ambient temperature and compensates the output. The shift in output by any ambient temperature change is dramatically reduced up to 1/10 of the shift without the compensation function. Integral digital indicator (optional) The output can be checked in the field with by using a digital indicator. Gasket selection Model JTE929A/JTE930A Silicone rubber and EPDM rubber gaskets and o- rings are available. Choose the appropriate material based on the following criteria. Silicone rubber gasket Since this gasket is resistant to solvents and chemicals, it is seldom damaged by polar organic Specifications are subject to change without notice. - 1-6th edition

compounds like alcohol, dilute acids, or dilute alkalis. During sterilization-in-place (SIP), hydrolysis or the like can damage the gasket. The gasket must be replaced regularly depending on the operating conditions or the application. EPDM rubber gasket Since this gasket is resistant to solvents and chemicals, it is seldom damaged by dilute alkalis. During sterilization-in-place (SIP), the gasket is generally less subject to damage by hydrolysis or the like than a silicone rubber one. The gasket must be replaced regularly depending on the operating conditions or the application. China RoHS This device is used in the Oil & Gas, Petrochemical, Chemical, Pulp & Paper, Food & Beverage, Machinery, Steel/Metal & Mining, and Automobile industries and therefore does not fall under the China RoHS Legislation. If this device is used in semiconductor manufacturing equipment, labeling on the device and documents for the China RoHS may be required. If such documents are required, consult an Azbil Corp. representative. HART is a registered trademark of the HART Communication FOUNDATION. SPECIFICATIONS - Common Output Analog output (4 to 20 ma DC) Digital output (DE protocol) Digital output (FOUNDATION TM Fieldbus protocol) Communication SFN communication HART communication FOUNDATION TM Fieldbus communication Supply voltage and load resistance 10.8 to 45V DC. 9 to 32 VDC ( FOUNDATION TM Fieldbus communication). A load resistance of 250 Ω or more is necessary between loops. (See Figure 1) Waterproof structure JIS C 0920 watertight, JIS F 8001 class 2 watertight NEMA3 and 4X, IEC IP67 Explosion-proof structure TIIS flameproof models: (Ex d II C T4X) Note) Please use the cable that can be used in the environment that maximum ambient temperature is beyond 65 C KOSHA flameproof models: (Ex d II C T4) Electrical conduit connection G1/2 internal thread Azbil Corporation Finish Baked acrylic paint Color Transmitter case: Light beige (Munsell 4YR7.2/1.3) Transmitter cover: Dark beige (Munsell 10YR4.7/0.5) Output 4 to 20mA DC Dead time Approx. 400 ms Stability against supply voltage change 0.005% F.S./V Lightning protection Peak value of voltage surge: 100 kv Peak value of current surge: 1000A Vibration effect Amptitude 1.5mm / Frequency 0 to 9Hz 5m/s 2 (0.5G) / 9 to 60Hz Impact effect 10m/s 2 (1G) Mounting Direct mounting on the process side Supply voltage / Load resistance Load resistance R (Ω) 1560 605 250 E - 10.8 R = 0.0218 Operating range 0 10.8 16.3 24 45 Supply voltage E (V DC) Figure 1 Supply voltage vs. Load resistance characteristics Note) For communication with Communicator, a load resistance of 250 W or more is necessary. For negative pressure range Working pressure (kpa {mmhg abs.}) Operative limit conditions (T: -121 C to -125 C) Normal operating conditions (T: -10 C to -121 C) Operative limit conditions (T: -20 C to -10 C) Temperatue of wetted parts ( C) Figure 2 Propyleneglycol (Food additive) - 2 -

Azbil Corporation OPTIONAL SPECIFICATIONS Built-in indicating meter The digital LCD indicator Corrosion-proof finish Corrosion-proof paint (Baked epoxy paint), fungusproof finish. Electro-polishing Finish 2 μm Passivation treatment Applying passivation treatment on the wetted part results better anti-corrosion. Zero adjustment function External zero adjustment function Water free treatment (including oil free treatment) The transmitter is shipped with dry and oil free wetted parts. Oil free treatment The transmitter is shipped with oil-free wetted parts. Extended type tank spud Extended type tank spud is for retaining a diaphragm of wetted part. It is welded to tank. No. SS2-DST800-0100 Transmitter installation notes WARNING When installing the transmitter, ensure that gaskets do not protrude from connecting points into the process (such as adapter flange connection points and connecting pipes and flanges). Failure to do so may cause a leak of process fluid, resulting in harm from burns, etc. In addition, if the process fluid contains toxic substances, take safety measures such as wearing goggles and a mask to prevent contact with the skin and eyes and to prevent inhalation. Use the transmitter within the operating ranges stated in the specifications (for explosion-proofing, pressure rating, temperature, humidity, voltage, vibration, shock, mounting direction, atmosphere, etc.). Using the transmitter outside the operating conditions may cause device failure or fire, resulting in a harmful physical risk of burning or the like. Some models of the transmitter have a mass of 10 kg or more because of differences in specifications. For your safety when transporting or installing the transmitter, use a dolly or two or more people. Carelessly lifting the transmitter and accidentally dropping it can cause injury or damage. Figure 3 Extended type tank spud Dimensions 4S L 50 100 D1 200 D2 119 Transmitter handling notes To make the most of the performance this transmitter can offer, please use it properly noting the points mentioned below. Before using it, please read the Instruction Manual. WARNING When performing wiring work in explosion-proof areas, follow the work method specified in the explosion-proof guidelines. In addition, when the wiring for an explosionproof product is a pull-in pressure-resistant packing cable, be sure to use a pressure-resistant packing-cable adapter certified by Azbil Corporation. Be sure to use the cable which allowable temperature is more than 65 C. CAUTION After installation, do not use the transmitter as a foothold or put your weight on it. Doing so may cause damage. Be careful not to hit the glass indicator with tools etc. This could break the glass and cause injury. Impact to transmitter can damage sensor module. - 3 -

Azbil Corporation Wiring notes WARNING To avoid shocks, do not perform electrical wiring work with wet hands or with live wires. CAUTION Do wiring work properly in conformance with the specifications. Wiring mistakes may result in malfunction or irreparable damage to the instrument. Use a power supply that conforms to the specifications. Use of an improper power supply may result in malfunction or irreparable damage to the instrument. Use a power supply with overcurrent protection for this instrument. Handling precautions for HART specification devices If you need to operate with a secondary host (HART communicator, etc.), set the communication interval of the primary host (DCS, device management system) to 8 seconds or more, or suspend communication from the primary host. If the primary host repeats HART communication within 8 seconds, the request from the secondary host may not be received (communication may not be possible). If electrical noise in the environment prevents HARTcommunications with the host, take countermeasures such as separating the signal cables from the source of the noise, improving the grounding, changing to shielded signal cables, etc. Even if noise interferes with HART communications, the 4-20 ma analog signal will be unaffected and can be used for control. If this product is being operated in multidrop mode, there is a limit to the number of devices that can be used. If you are using multidrop mode, please consult with us. - 4 -

Azbil Corporation No. SS2-DST800-0100 SPECIFICATIONS - Sanitary flange 4S clamp connection Measuring span / Setting range / Working pressure range / Overload resistant value Model Measuring span Setting span Working pressure range JTC929A JTC940A 2.5 to 100 kpa {250 to 10,000 mmh2o} 70 to 3500 kpa {0.70 to 35 kgf/cm²} -100 to 100 kpa {-10000 to 10000 mmh2o} Up to the IDF clamp pressure rating -100 to 3500 kpa (700 kpa {7 kgf/cm²}) {-1 to 35 kgf/cm²} Process pipe connection IDF 4S clamp connection (Flush diaphragm / Extended diaphragm type) Materials Flush diaphragm...316l SST Wetted parts...316l SST Center body...316 SST Transmitter case...aluminum alloy Meter body cover..susf304 Gasket...Silicone rubber or EPDM rubber O-ring...Silicone rubber or EPDM rubber Fill fluid Propylenglycol (Food additive) Specific gravity: 1.032 Working pressure range 10 kpa abs. (1000 mmh2o abs.) up to the IDF clamp pressure rating (700 kpa {7 kgf/cm²}) For negative pressure range, see Figure 2. Ambient temperature range -10 to +60 C Temperature ranges of wetted parts -10 to +121 C 150 C, 60 min. Temperature range for transportation an storage -20 to +60 C Ambient humidity range 5 to 100% RH Weight Approx. 4.2 kg (4S flush diaphragm type) Other specifications Refer to common specifications. Accuracy / temperature characteristics Model JTC929A JTC940A Accuracy ± 0.3% (χ > 25 kpa) ± 0.2% (χ > 350 kpa) 25 ± 0.15 + 0.15 ----- % (χ < 25 kpa) ± χ 0.05 0.15 350 + -------- χ (χ < 350 kpa) Ambient temperature characteristics Zero shift Change of 30 C Ambient temperature characteristics Combined shift Change of 30 C 25 ± 0.25 + 0.5 ----- % ± χ 0.15 0.30 350 + -------- χ ± 1.6% (χ > 25 kpa) ±0.7% (χ > 350 kpa) 25 ± 1 + 0.6 ----- % (χ < 25 kpa) ± (χ < 350 kpa) χ 0.25 0.45 350 + -------- χ Shown for each item are the upper limit (URV) *1 and the lower limit (LRV) *2 of the calibration range or the percentage ratio of the maximum value of the span to χ (kpa). Note) *1: URV denotes the value for 100% (20 ma DC) output. *2: LRV denotes value for 0% (4 ma DC) output *3: Within a range of URV > 0 and LRV > 0-5 -

Azbil Corporation MODEL SELECTIONS - Sanitary flange 4S clamp connection Model JTC929A/940A - Sanitary service (Fill fluid: Propyleneglycol) Process connection: 4S clamp. Basic model no. Selections Options 1 Options 2 - I II III IV V VI VII VIII - IX X XI XII XIII - Basic model no. Measuring span 2.5 to 100 kpa (250 to 10,160 mmh2o) Medium differential pressure JTC929A 70 to 3500 kpa (0.7 to 35 kgf/cm²) High differential pressure JTC940A Selections - I Output 4 to 20 ma (SFN protocol) 1 Digital output (DE protocol ) *1 *2 3 Digital output (FOUNDATION 4 Fieldbus protocol) *3 4 to 20 ma (HART protocol) 5 II Material Ferrule Wetted parts 316L SST 316L SST L III Fill fluid Propyleneglycol (Food additive) B IV Process connection Open to atmosphere V V Flange rating IDF U VI Clamp size Clamp 4S A VII Ferrule type Standard (Flush diaphragm) 1 Length extended part 50mm (silicone rubber o-ring) 2 Length extended part 100mm (silicone rubber o-ring) 3 Length extended part 50mm (EPDM rubber o-ring) J Length extended part 100mm (EPDM rubber o-ring) K VIII Material of flange/ bolts and nuts Ferrule 1 Options 1 - IX Electrical connection / G1/2, Watertight X explosion-proof G1/2, TIIS Flameproof with 1 pc. of cable gland attached 2 G1/2, TIIS Flameproof with 2 pcs. of cable gland attached. 3 G1/2, TIIS Intrinsically safe *4 K G1/2, KOSHA Flameproof P X Builting indicating None X smart meter 0 to 100% linear scales 1 Engineering unit scales 2 XI Finish Standard X Corrosion-proof B XII Finish of gasket face Standard (JIS Ra3.2 (12.5S)) X Electro polishing A Passivation B XIII Burnout feature None X Upper limit of output at abnormal condition U Lower limit of output at abnormal condition D - 6 -

Azbil Corporation No. SS2-DST800-0100 Options 2 No options External zero adjustment *2 *4 Lightening arrestor *4 Water free finish (included oil free finish) Oil free finish One elbow (Right) Fieldbus communication stack BASIC class Special burn-out feature (3.2 ma) *4 *5 Test report Traceability certificate Two sets of IDF clamp with silicone gaskets for flush diaphragm type Two sets of IDF clamp Two sets of silicone gaskets for flush diaphragm type Extended type tank spud for 4S clamp IDF clamp and EPDM gasket (for flush diaphragm type only) IDF EPDM gasket (for flush diaphragm type only) Non-SI unit conformance Note) 1:Digital output (DE protocol) should be selected with upper/lower direction of burn out feature. 2:Digital output (DE protocol) can not be combined with an external zero adjustment function. 3:Code L1 must be selected for Options 2. 4:This option can not be combined with FOUNDATION TM Fieldbus. 5:This should be selected with lower of burn out feature. XX A2 A4 D1 D2 G2 L1 J8 T1 T8 S1 S2 S3 S4 S6 S7 U2-7 -

Azbil Corporation DIMENSIONS - Sanitary flange 4S clamp connection Terminal connection diaphragm (Terminal screw size: M4) Approx. Electrical conduit connection port Approx. 231 W/O indicator Approx. W/ indicator Approx. 5 Approx. External zero adjustment (optional) Model no. Ferrule φd φd φc φm T Flange rating Flange size Flange type size U A 1 IDF 4S 119 102.5 110 90 35 Extended diaphragm flange dimensions Model no. Ferrule φd φd φk φm Model no. L Flange rating Flange size size Flange type U A IDF 4S 119 102.5 101.5 90 2 50 3 100-8 -

Azbil Corporation No. SS2-DST800-0100 SPECIFICATIONS - Sanitary remote-sealed diaphragm 2S, 3S, 4S clamp connection Measuring span / Setting range / Working pressure range / Overload resistant value Model Measuring span Setting span Working pressure range JTE929A JTE930A 2.5 to 100 kpa {250 to 10,000 mmh2o} 35 to 700 kpa {0.35 to 7 kgf/cm²} Process pipe connection IDF 2S, 3S, 4S clamp connection (Flush diaphragm / Extended diaphragm type) Materials Diaphragm...316L SST Wetted parts...316l SST Center body...316 SST Transmitter case...aluminum alloy Meter body cover...scs13 Capillary tube coating..olefin Gasket... Silicone rubber or EPDM rubber O-ring... Silicone rubber or EPDM rubber Fill fluid Propyleneglycol (Food additive) Specific gravity: 1.032 Working pressure range 10 kpa abs. (1000 mmh2o abs.) up to the IDF Accuracy / temperature characteristics -100 to 100 kpa {-10000 to 10000 mmh2o} Up to the IDF clamp pressure rating -100 to 700 kpa (700 kpa {7 kgf/cm²}) {-1 to 7 kgf/cm²} clamp pressure rating (700 kpa {7 kgf/cm²}) For negative pressure range, see Figure 2. Ambient temperature range -10 to +60 C Temperature ranges of wetted parts -10 to +121 C (Sterilization) 150 C, 60 min. (Steam wash) Temperature range for transportation an storage -20 to +60 C Ambient humidity range 5 to 100% RH Weight Approx. 7.4 kg (2S flush clamp connection and capillary 3 m) Other specifications Refer to common specifications. Model JTE929A JTE930A Accuracy Linear out: ± 0.3% (χ > 12.5 kpa) Linear out: ± 0.2% (χ > 210 kpa) 12.5 ± % ± 0.3 --------- % (χ < 12.5 kpa) χ 0.05 0.15 210 + -------- χ (χ < 210 kpa) Temperature Zero shift: ± 0.14% (χ > 25 kpa) characteristics (Shift from the ± 25 0.14 ----- % (χ < 25 kpa) set range) 4S χ Zero shift: ± 0.05 + 0.09 210 -------- % χ Change of 10 C 3S Combined shift: ± 0.3% (χ > 25 kpa) (χ > 210 kpa) 2S ± 0.3 25 ----- % χ (χ < 25 kpa) Zero shift ± 0.36% (χ > 25 kpa) ± 25 0.36 ----- % (χ < 25 kpa) χ Combined shift: ± 2.18% (χ > 25 kpa) ± 25 2.18 ----- % (χ < 25 kpa) χ Shown for each item are the upper limit (URV) *1 and the lower limit (LRV) *2 of the calibration range or the percentage ratio of the maximum value of the span to χ (kpa). Note) *1: URV denotes the value for 100% (20 ma DC) output. *2: LRV denotes value for 0% (4 ma DC) output *3: Within a range of URV > 0 and LRV > 0-9 - 4S 3S 2S Combined shift: ± 0.51% (χ > 210 kpa) ± 0.4 + 0.11 210 -------- % χ (χ < 210 kpa)

Azbil Corporation MODEL SELECTIONS - Sanitary remote-sealed diaphragm 2S, 3S, 4S clamp connection Model JTE929A/930A - Sanitary service (Fill fluid: Propyleneglycol) Process connection: 4S/3S/2S clamp. Basic model no. Selections Options 1 Options 2 - I II III IV V VI VII VIII - IX X XI XII XIII XIV - Basic model no. Measuring span 2.5 to 100 kpa (250 to 10,160 mmh2o) Medium differential pressure JTE929A 35 to 700 kpa (0.35 to 7 kgf/cm²) High differential pressure JTE930A Selections - I Output 4 to 20 ma (SFN protocol) 1 Digital output (DE protocol)*1 3 *2 Digital output (FOUNDATION 4 Fieldbus protocol) *3 4 to 20 ma (HART protocol) 5 II Material of wetted part 316L SST 8 III Fill fluid Propyleneglycol (Food additive) B IV Flange rating IDF U V Clamp size Clamp 4S A Clamp 3S B Clamp 2S C VI Ferrule type Standard (Flush diaphragm) 1 Length of extended part 50 mm (silicone rubber 2 o-ring) Length of extended part 100 mm (silicone rubber 3 o-ring) Length of extended part 50 mm (EPDM rubber J o-ring) Length of extended part 100 mm (EPDM rubber o-ring) K VII Material of bolts and Carbon steel N nuts 304 SST P 630 SST Q VIII Length of capillary 2 m B tube with olefin 3 m C coating 5 m D Options 1 - IX Electrical connection / G1/2, Watertight X explosion-proof G1/2, TIIS Flameproof with 1 pc. of cable gland attached 2 G1/2, TIIS Flameproof with 2 pcs. of cable gland attached. 3 G1/2, TIIS Intrinsically safe *4 K G1/2, KOSHA Flameproof P X Builting indicating None X smart meter 0 to 100% linear scales 1 Engineering unit scales 2 XI Finish Standard X Corrosion-proof B XII Finish of gasket face Standard (JIS Ra3.2 (12.5S)) X Electro polishing A Passivation B XIII Burnout feature None X Upper limit of output at abnormal condition U Lower limit of output at abnormal condition D XIV Mounting bracket None X Carbon steel 1 304 SST 2-10 -

Azbil Corporation No. SS2-DST800-0100 Options 2 No options External zero adjustment *4 Lightening arrestor *4 Water free finish (included oil free finish) Oil free finish One elbow (Left) One elbow (Right) Two elbows Fieldbus communication stack BASIC class Special burn-out feature (3.2 ma) *4 *5 Test report Traceability certificate IDF clamps with silicone gaskets (2 each, for flush diaphragm type only) IDF clamps (2) IDF silicone gaskets (2, for flush diaphragm type only) Extended tank spud (1) Extended tank spud (2) IDF clamp and EPDM gasket (for flush diaphragm type only) IDF EPDM gasket (for flush diaphragm type only) Note) 1:Digital output (DE protocol) should be selected with upper/lower direction of burn out feature. 2:Digital output (DE protocol) can not be combined with an external zero adjustment function. 3:Code L1 must be selected for Options 2. 4:This option can not be combined with FOUNDATION TM Fieldbus. 5:This should be selected with lower of burn out feature. XX A2 A4 D1 D2 G1 G2 G3 L1 J8 T1 T8 S1 S2 S3 S4 S5 S6 S7-11 -

Azbil Corporation DIMENSIONS - Sanitary remote-sealed diaphragm 2S, 3S, 4S clamp connection Electrical conduit connection port Flange connection (low pressure side) M4 terminal screw for grounding ring Installation method without mounting bracket depth Terminal connection diaphragm (Terminal screw size: M4) Electrical conduit connection port Flange connection (high pressure side) Length of capillary (With indicators 265) (Without indicator 261) With indicators 210 Without indicator 206 Approx. 2-inch pipe External zero adjustment (optional) Flange dimensions Flange dimensions Model no. Flange rating Flange size Ferrule size - 12 -

Azbil Corporation No. SS2-DST800-0100 SPECIFICATIONS - Sanitary remote-sealed diaphragm 2S cap nut connection Measuring span / Setting range / Working pressure range / Overload resistant value Model Measuring span Setting span Working pressure range JTE929A JTE930A 2.5 to 100 kpa {250 to 10,000 mmh2o} 35 to 700 kpa {0.35 to 7 kgf/cm²} -100 to 100 kpa {-10000 to 10000 mmh2o} Up to the IDF clamp pressure rating -100 to 700 kpa (700 kpa {7 kgf/cm²}) {-1 to 7 kgf/cm²} Process pipe connection IDF 2S cap nut connection (Flush diaphragm) Materials Diaphragm...316L SST Wetted parts...316l SST Center body...316 SST Transmitter case...aluminum alloy Meter body cover...susf304 Capillary tube coating..olefin Gasket... Silicone rubber or EPDM rubber O-ring... Silicone rubber or EPDM rubber Fill fluid Polyleneglycol(Food additive) Specific gravity: 1.032 Working pressure range 10 kpa abs. (1000 mmh2o abs.) up to the IDF clamp pressure rating (700 kpa {7 kgf/cm²}) For negative pressure range, see Figure 2. Ambient temperature range -10 to +60 C Temperature ranges of wetted parts -10 to +121 C (Sterilization) 150 C, 60 min. (Steam wash) Temperature range for transportation an storage -20 to +60 C Ambient humidity range 5 to 100% RH Weight Approx. 8.2 kg (2S cap nut connection and capillary 3 m) Other specifications Refer to common specifications. Accuracy / temperature characteristics Model JTE929A JTE930A Accuracy Linear out: ± 0.3% (χ > 12.5 kpa) ± 0.2% (χ > 210 kpa) ± 12.5 0.3 --------- % (χ < 12.5 kpa) ± 210 % χ 0.05 + 0.15 -------- χ (χ < 210 kpa) Temperature Zero shift: ± 0.36% (χ > 25 kpa) characteristics ± 210 0.05 + 0.09 -------- % (Shift from the ± 25 0.36 ----- % (χ < 25 kpa) χ χ set range) Change of 10 C Combined shift: ± 2.18% (χ > 25 kpa) ± 0.51% (χ > 210 kpa) ± 2.18 25 ----- % (χ < 25 kpa) ± 0.4 + 0.11 210 -------- % χ χ (χ < 210 kpa) Shown for each item are the upper limit (URV) *1 and the lower limit (LRV) *2 of the calibration range or the percentage ratio of the maximum value of the span to χ (kpa). Note) *1: URV denotes the value for 100% (20 ma DC) output. *2: LRV denotes value for 0% (4 ma DC) output *3: Within a range of URV > 0 and LRV > 0-13 -

Azbil Corporation MODEL SELECTIONS - Sanitary remote-sealed diaphragm 2S cap nut connection Model JTE929A/930A - Sanitary service (Fill fluid: Propyleneglycol) Process connection: 2S cap nut. Basic model no. Selections Options 1 Options 2 - I II III IV V VI VII VIII - IX X XI XII XIII XIV - Basic model no. Measuring span 2.5 to 100 kpa (250 to 10,160 mmh2o) Medium differential pressure JTE929A 35 to 700 kpa (0.35 to 7 kgf/cm²) High differential pressure JTE930A Selections - I Output 4 to 20 ma (SFN protocol) 1 Digital output (DE protocol) 3 *1 *2 Digital output (FOUNDATION 4 Fieldbus protocol) *3 4 to 20 ma (HART protocol) 5 II Material of wetted part 316L SST 8 III Fill fluid Propyleneglycol (Food additive) B IV Flange rating IDF U V Clamp size Cap nut 2S 8 VI Ferrule type Standard (Flush diaphragm) 1 VII Material of bolts and Carbon steel N nuts 304 SST P 630 SST Q VIII Length of capillary 2 m B tube with olefin 3 m C coating 5 m D Options 1 - IX Electrical connection / G1/2, Watertight X explosion-proof G1/2, TIIS Flameproof with 1 pc. of cable gland attached 2 G1/2, TIIS Flameproof with 2 pcs. of cable gland attached. 3 G1/2, TIIS Intrinsically safe *4 K G1/2, KOSHA Flameproof P X Builting indicating None X smart meter 0 to 100% linear scales 1 Engineering unit scales 2 XI Finish Standard X Corrosion-proof B XII Finish of gasket face Standard (JIS Ra3.2 (12.5S)) X Electro polishing A Passivation B XIII Burnout feature None X Upper limit of output at abnormal condition U Lower limit of output at abnormal condition D XIV Mounting bracket None X Carbon steel 1 304 SST 2 Options 2 No options XX External zero adjustment A2 Lightening arrestor A4 Water free finish (included oil free finish) D1 Oil free finish D2 One elbow (Left) G1 One elbow (Right) G2 Two elbows G3 Fieldbus communication stack BASIC class L1 Special burn-out feature (3.2 ma) *5 J8 Test report T1 Traceability certificate T8 IDF silicone gaskets (2) S3 IDF EPDM gaskets (2) S7-14 -

Azbil Corporation No. SS2-DST800-0100 Note) 1:Digital output (DE protocol) should be selected with upper/lower direction of burn out feature. 2:Digital output (DE protocol) can not be combined with an external zero adjustment function. 3:Code L1 must be selected for Options 2. 4:This option can not be combined with FOUNDATION TM Fieldbus. 5:This should be selected with lower of burn out feature. DIMENSIONS - Sanitary remote-sealed diaphragm 2S cap nut connection Electrical conduit connection port Flange connection (low pressure side) M4 terminal screw for grounding ring Installation method without mounting bracket depth Terminal connection diaphragm (Terminal screw size: M4) Electrical conduit connection port Flange connection (high pressure side) Length of capillary (With indicators 265) (Without indicator 261) With indicators 210 Without indicator 206 Approx. 2-inch pipe External zero adjustment (optional) Flange rating Model no. Flange size Terminal screw size D φ M φ A φ B U 8 IDF 2S 76 43 56.2 60.5 60-15 -

Azbil Corporation - 16-1st edition: Sep. 2001 6th edition: July 2013