CM707 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Similar documents
CM707 (UK Version) PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Modbus Integration Integration for Modbus Functionality for VT8600 Series

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

The Complete TPMS Solution. Universal TPMS Sensors and Programming Tool. Pre-programmed Direct-Fit TPMS Sensors

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Cooled incubators (ST), laboratory refrigerators

ACCESSORIES BROCHURE LUCAS 2 3. Chest Compression System GENUINE ACCESSORIES FROM PHYSIO-CONTROL

LUCAS 2 3. Chest Compression System. Genuine Accessories

Technical Data Sheets

Technical Data Sheets

Laboratory refrigerators

MC200CAB/4 Integral Version

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Opening hours Monday - Friday, 8.00am pm Weekends and Bank Holidays, 8.30am pm We are closed on Christmas Day and New Year s Day.

USER GUIDE Digital Thermostat GUIDE D UTILISATION Thermostat digital Bedienungsanleitung Termostato digital 50-72

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SPARE PARTS LIST ROBOTIC LAWN MOWERS AUTOMOWER 305,

HERZ Electronic room thermostat analog and digital

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

PowerView PV380-R2 Mechanical Configuration

310/315. Spare parts Ersatzteile Pièces détachées Reserve onderdelen Repuestos Reservdelar.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

IPL, Automower 310/315, , /315. Spare parts Ersatzteile Pièces détachées Reserve onderdelen Repuestos Reservdelar

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Level Measurement Continuous level measurement Ultrasonic transmitters

Digital Room Thermostats with Touch Screen LCD

SPARE PARTS LIST ROBOTIC LAWN MOWERS AUTOMOWER 430X,

TIMER INTERFACE USER MANUAL

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

LIFEPAK 1000 DEFIBRILLATOR. Genuine Accessories from Physio-Control

IPL, Automower 105, , , Spare parts Ersatzteile Pièces détachées Reserve onderdelen Repuestos Reservdelar

Installation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents

IPL, Automower 450X, , , 450X Spare parts Ersatzteile Pièces détachées Reserve onderdelen Repuestos Reservdelar

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SPARE PARTS LIST ROBOTIC LAWN MOWERS AUTOMOWER 430X,

User Manual. Solar Charge Controller 3KW

Game changing soft starters

MICRO-200 Battery Conductance Tester User Manual


Yaskawa AC Drive L1000A Supplement to the L1000A Technical Manual No. SIEP C , SIEP C , and SIEP C

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

Digital Time Switches

Electro Controls. Temperature Controllers WattsIndustries.co.uk

IPL, Automower 420, , , 2016 Spare parts Ersatzteile Pièces détachées Reserve onderdelen Repuestos Reservdelar

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

i n s t r u c t i o n m a n u a l

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom

IPL, Automower 450X, , , 450X Spare parts Ersatzteile Pièces détachées Reserve onderdelen Repuestos Reservdelar

HEAVY DUTY POWER RELAYS FEATURES

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Fan Coil Thermostat. Specification & Installation instructions TFC54F3X1. Technical Data

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

SPARE PARTS LIST ROBOTIC LAWN MOWERS AUTOMOWER 430X, 2018-

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control. EVOLUTION r CONNEX t CONTROL

User Manual Solar Charge Controller 3KW

VisionPRO 8000 Thermostats

USERS MANUAL MCD REMOTE OPERATOR

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Heavy-Duty Battery and Electrical System Diagnostic Tester

Active Interface Module Active Line Module chassis format, air-cooled

Mounts on the paper feed assembly in the paper pick-up assembly

LK Control v.3 & LK Control v.3 - RA

AC Induction Motor Controller with VCL

T2 Tester. Calibration Information. Introduction. Safety Information

INVERTER DUCTED SYSTEMS

Digital Room THERMOSTAT for Model No. RT300

Product Data. SYSTXCCITC01---B Infinityr System Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR SYSTEM CONTROL

SPARE PARTS LIST ROBOTIC LAWN MOWERS ROB R600/ROB R1000,

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

ZonePlus Z322 zone valve Installation and commissioning instructions

IPL, Automower 308, , Spare parts Ersatzteile Pièces détachées Reserve onderdelen Repuestos Reservdelar

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

Wireless Digital Room Thermostat with Night Set-Back

8 Parts and diagrams. Order parts, accessories, and supplies. Supplies part numbers. Illustrations and parts lists.

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

Transfer switch GTEC open or delayed transition

Table of Contents. Chapter 1 Product Summary... 2

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Operating principle Application diagram. Regulator-actuator Wiring diagrams

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

User's Guide of BST-360 Battery System Tester. BST-360 Battery System Tester User's Guide 1 / 15

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

Features and Benefits. Control Features

Programming Guide. Futura Spas TMTM. in.k300. in.k300. the essential spa keypad. Bright LCD screen Spa function icons. Spa function icons.

EFFICIENT SLEEPER COMFORT. Volvo s Battery-powered Parking Cooler Option

IPL, Automower 320, , Spare parts Ersatzteile Pièces détachées Reserve onderdelen Repuestos Reservdelar

REMA TIP TOP TPMS Tyre Pressure Monitoring Systems

RC-DO. Room controllers with display and manual forced ventilation function

User s Guide Rain Dial Plus 6, 9 and 12 Station Indoor and Outdoor Models

Transcription:

CM707 PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET The CM707 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It can be used as part of a system in conjunction with combiboilers, oil-burners and gas fired boilers, circulation pumps, thermal actuators, zone valves and electric heat systems (<5A). The CM707 is designed with the installer in mind and includes a moulded back-plate with trunking guides and wiring breakouts to make installation quick and easy. The CM707 large LCD display, button layout based on the same simple programming philosophy used on our acclaimed CM20 products and the introduction of an OK button makes it easier to install and more user friendly. The unit is ideal for consumers who want reliable precise temperature control from a modern looking, simple to program and easy to use product. FEATURES Attractive slim, modern styling makes it ideal for location in any type of home. 7 day heating program. Up to 4 daily independent time and temperature level changes let you set 4 time and temperatures pairs to suit your lifestyle. Temporary programmed temperature override to temporarily override the programmed temperature till the next switch point. Holiday button provides energy savings by reducing the temperature from to 99 days when people are on holiday, returning to normal operation (AUTO or MANUAL) on the day of their return. Room Enquiry. EEPROM memory holds the user program indefinitely. OFF mode has an integral frost protection setting at minimum 5 C (installer adjustable) so that pipes in the house will never freeze in winter. 24...230V 5A resistive, 2A inductive SPDT relay provides compatibility with most domestic central heating systems reducing the need to stock many different models. Battery powered by 2 x AA size (LR6) alkaline cells. Minimum battery life of 2 years with low battery warning indicator. Built-in default heating program. Surface or wall box mounting options, with trunking guides and wiring breakouts to simplify installation. No installer links or special installer switches on the back of the unit mean no adjustment is required for combi-boilers and most domestic central heating systems. User Set-Up Mode allows extra functions to be set at the discretion of the user: AM-PM or 24hr time display. Resetting the heating profile to factory default. Installer Set-Up Mode allows extra functions to be set at the discretion of the installer to match the consumers applications and needs: Pump Exercise. Upper / Lower Set point Adjust. offset. Minimum ON time. Cycle rate. Proportional Band Width. Diagnostic Mode to assist in fault finding. EN0H 8544 UK07 R 09/06

CONTROLS/ DISPLAY LAYOUT PRODUCT LAYOUT:. LCD Screen 2. Battery Low Indicator 3. Time Display 4. Burner On Indicator 5. Day Indicator 6. Display 7. Change Buttons 8. Information Enquiry Button 9. Operating Mode Buttons 0. Green OK Button. Battery Compartment 2. Battery Cover 3. Holiday Function Button 4. Program Buttons 5. Copy Day Button 6. Day Select Button 7. Time Change Buttons SPECIFICATIONS Batteries Battery life Battery replacement Switch type Electrical rating Time display Time keeping accuracy Program Time setting resolution : 2 x.5 V IEC LR6 (AA) Alkaline cells : Minimum 2 years : Program retained in EEPROM : SPDT (potential free) : 230 V~, 50...60 Hz, 0. A to 5 A resistive 0. A to 2 A inductive (0.6 pf) 24 V~, 50...60 Hz, 0.5 A to 5 A resistive 0.5 A to 2 A inductive (0.6 pf) : 24 hour or 2 hour AM/PM format : Typically better than 0 minutes per year : 7 day with 4 daily time and temperature level changes : Time of day - minute Program - 0 minute steps Sensing element : 00K (@ 25 o C ) NTC thermistor setting range : Program : 5 to 35 o C in 0.5 o C steps Frost : 5 o C or equal to lower limit (5 o C to 2 o C). control accuracy Room display range Control form Minimum ON time Cycle rate Wiring Wire access : ±0.5 K (nominal) @ 20 o C, 50% load 3 K Δ/hour : From 0 o C to 50 o C : P + I (Proportional + Integral) : 0% of cycle time (min one minute), adjustable to 2 to 5 min (see installer set up) : Selectable by application (see installer set up) : Terminal block capable of accepting wires up to 2.5 mm 2 : Mains wiring rear right. Low voltage wiring rear right. Dimensions : 33 x 88.5 x 26 mm (w x h x d) 33 x 75 x 26 mm (w x h x d) (flap open) Environmental Approvals : Operating temperature range 0 to 40 o C Shipping and storage temperature range -20 to 55 o C Humidity range 0 to 90% rh, noncondensing : Designed to meet European EN approvals EN60730-(Nov 2000), EN5504- (997), EN5504-2 (2000) 2 EN0H 8544 UK07 R 09/06

INSTALLER SET-UP To enter the installer set-up mode: a) Press the OFF button. b) Press and hold the INFO i button and the two program buttons < > together. c) The unit will display the first parameter of installer parameter group category (from n. to n.9). d) Press the TEMP or buttons to change the factory setting. The display will flash indicating that a change has been made. e) Press the green OK button to confirm this change and the display will stop flashing. f) Press the + button to go to the next parameter. g) Press the program button > to go to category 2 in the Installer mode (from n. to n.5). h) To exit the installer mode, press the AUTO, MAN or OFF buttons. Abbreviated Set-Up Description e.g. Cl = Clock Format In Installer set-up we can: Set-up specific applications Enable special features Installer Set-up Number (Press + or - to change) e.g. = Clock Format Factory Setting or New Choice Press TEMP or to change e.g. 2 = AM/PM Format 24 = 24hr Format Specific Applications Setting What do you need to change? Cycle/ Hour Minimum ON time (in minutes) Note : a. To change Cycle/Hour, please go to parameter n. 2, category 2 in the installer set-up mode. b. To change Minimum ON Time, please go to parameter n., category 2 in the installer set-up mode. Heating Gas Boilers (<30KW) 6 No action required Oil Boiler 3 4. Set Minimum ON Time to 4 minutes. 2. Set Cycle/Hour to 3. Thermal Actuator 2 Set Cycle/Hour to 2. Zone valve 6 No action required. Electric heating (for applications <5A) 2 Set Cycle/Hour to 2. 3 EN0H 8544 UK07 R 09/06

Special Features Description What to do if we wish this feature AM-PM/ 24hr Display Change display format (default 24hr). Set parameter n., category in the installer set -up mode to 2. Pump exercise Upper Lower Offset Proportional Band Width When enabled the Pump Exercise will switch the relay on for minute at 2:00 if the relay has not been switched on since 2:00 the previous day. While in Holiday mode the Pump Exercise feature, if enabled, will operate. The normal upper temperature limit of 35 o C can be reduced down to 2 o C to save the homeowner energy. Useful if the homeowner rents to tenants. The normal lower temperature limit of 5 o C can be increased up to 2 o C to protect the inhabitants from cold. Useful if the inhabitants include the elderly, children or disabled. If the thermostat is located in a hot/cold location and cannot be moved because of wiring then the measured/ displayed temperature can be adjusted by +/- 3 o C. Useful if the homeowner wants the reading to match another appliance temperature display. Can be adjusted up to 3 o C (default is.5 o C) to provide better temperature control (less overshoot). Useful for: a. Well insulated homes with over-sized heating systems. b. Air systems with fast response. Set parameter n.5, category 2 in the installer set -up mode to. Set parameter n.6, category in the limit. Set parameter n.7, category in the limit. Set parameter n.2, category in the offset value. Set parameter n.3, category in the value. 4 EN0H 8544 UK07 R 09/06

Parameter Installer Set-Up Number / Abbreviation (Press + or - keys to select) Factory Setting Optional Setting Installer Set- Up Category Display Description Display/Setting Description (Press PROG keys < or > to select) Category : Thermostat Parameters AM-PM / 24hr Display :Cl 24 24 hr clock display 2 2 hr AM / PM clock display RESET Time / Program 2:rP Time / profile set to factory default Changes to 0 when one of the time/temp profiles are changed 0 Time / are as programmed To restore the factory profile set to Upper 6:uL 35 35 C Upper Temp. 2 to 34 2 C to 34 C adjustment in C steps Lower 7:LL 5 5 C Lower Temp. 6 to 2 6 C to 2 C adjustment in C steps Offset 2:tO 0 No offset -3 to +3-3 C to +3 C adjustment in 0. C steps Proportional Band Width 3:Pb.5.5 C Proportional Band.6 to 3.0.6 C to 3.0 C adjustment in 0. C steps Reset Parameters to Factory Defaults 9:FS All settings held are the factory defaults. Changes to 0 when one of the parameter values are changed 0 Settings are as modified above To restore the factory profile set to Category 2: System Parameters (You must press the > program key to enter this section) Minimum ON Time :Ot minute minimum ON time 2 to 5 2-2 minutes 3-3 minutes 4-4 minutes 5-5 minutes 2 Cycle Rate 2:Cr 6 6 cycles per hour (cph) for gas boilers, zone valves and fancoil 3, 9, 2 3-3 cph 9-9cph 2-2 cph 2 Pump Exercise 5:PE 0 Pump Exercise Disabled Pump Exercise Enabled 2 5 EN0H 8544 UK07 R 09/06

DIMENSIONS INSTALLATION LOCATION The CM707 thermostat is the control element of the heating system and, therefore, MUST be located in a position with good air circulation, at average room temperature and on an inside wall,.5 metres above the floor level. Do not position the CM707 thermostat near sources of heat (radiators, hot air vents, TV or lights), near doors or windows, or in direct sunlight. MOUNTING The CM707 thermostat can be mounted directly on the wall surface or on to an electrical wall box. WIRING The CM707 thermostat is designed for fixed wiring only and must be installed in accordance with the latest l.e.e. regulations. Ensure the wiring connection to the supply is via a fuse rated at no more than 5 amps and a Class "A" switch (having contact separation of at least 3 mm in all poles). IMPORTANT. The installer must be a trained service engineer. 2. Disconnect the power supply before beginning installation. 6 EN0H 8544 UK07 R 09/06

WIRING ORDERING SPECIFICATION Description Model Logo Literature Availability Spec Sheet 7-day programmable thermostat CMT707A003 Honeywell French, Dutch, Italian, Spanish, German, Portuguese. Aug 05 ENOH8544 CMT707A0 Honeywell Czech, Polish, Slovakian, Hungarian, Romanian, Russian. Aug 05 ENOH8544 CMT707A037 Honeywell English, Greek, Turkish, Croatian, Slovenian. Nov 06 ENOH8544 EN0H 8544 UK07 R 09/06