NALTF & NALTRF Belt Drive Roof and Plantroom Twinfans

Similar documents
3ph Belt Drive, Run & Standby, Roof & Plantroom Twinfans

NALSF & NALSRF Belt Drive Roof and Plantroom Single Fans

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour

AXUS AXR. Roof Mounted Axial Fan for Smoke Control Installation and Maintenance. Handling

MARK TEN. Belt Drive Roof Mounted Extract Fans. Installation and Maintenance. Standby motor when fitted. Anti-vibration mountings

Installation and Maintenance

Terminator Input. (TIA) GRP Roof/Wall Input/Supply Fans. Installation and Maintenance

Drimaster365. Low Energy Positive Input Ventilation Unit. Installation and Maintenance Details. 150mm dia. Flexible Ducting

Terminator. TRA/TRM/TRC Roof Extract Fan. Installation and Maintenance

Q-AIRE-V125, EV125F & EV125FH 125mm diameter Filtered Inlet/Extract Air Valve. n Low profile. n Adjustable for commissioning purposes

QUIETSCROLL TWIN FAN RANGE

XS Fans Switches & Sensors

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

AXS. Installation and Maintenance. AXUS Swift Circular Long Cased Axial Flow Fans. 1.0 Introduction. 3.0 Installation And General Advice. 2.

MRXBOX-VSC Visual System User Control Installation and Maintenance

Single Phase Electronic Speed Controllers

IAQ-V mm Ø Carbon Filtered Supply Valve

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

Warning. Document ref: A October 2015

HIGH TEMPERATURE TWIN SQUIF FANS

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

PSU EN54-4 Power Supplies

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS

INSTRUCTION MANUAL. AMS 4000 One Piece. Negative Pressure Unit (AMS-4000 NPU 230V)

AXUS HIGH TEMPERATURE AXIAL FANS

PRECISION UK Ltd DUPLEX AGSS PLANT

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

INSTRUCTION MANUAL. AMS 1500 One Piece. Negative Pressure Unit (AMS-1500 NPU 230V)

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

SELF PRIMING CHEMICAL SERVICE PUMPS

SECTION AXIAL HVAC FANS

Operating Instructions

MV Series Motors Operation & Parts Manual

OPERATING MANUAL C-1350 CABLE PUSHER. Copyright 2003 by CBS Products (KT), Ltd

DX Ceiling Fan Kit 50Hz/60Hz Supply / Extract Units Installation and Maintenance

Installation and Maintenance. Axial Flow Fans DuctMaster Circular Bifurcated. Contents WARNING! Page General Description.

TWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A

Operating Instructions

NCSA 20plus Service Manual

The Powermatic User Guide Test Sieve Shaker

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Crane Forks. Introduction. Important Notes. Key Benefits. User Guide

TPAK Series COOLANT PUMP

Label Information: FPS75 FPS80 Cranking Warning Label

Excavator Forks. Introduction. Important Notes. Key Benefits. User Guide

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

Crane Forks. Introduction. Important Notes. Key Benefits. User Guide

SECTION CENTRIFUGAL HVAC FANS

READ AND SAVE THESE INSTRUCTIONS

LIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

Breezair TBA 550 Installation Manual

TPHK Series Immersible Pump

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

DX Window Fan Kit 50Hz/60Hz Supply / Extract Units Installation and Maintenance

Peristaltic Cased Tube Pumps

TPHK Series Immersible Pump

Aerocourse Fan Assisted Trench Heating

MAJAX-2 GENERAL SPECIFICATION

Pro Series 2120 COMMERCIAL ROLLER SHUTTER OPENER

Installation, Operation and Maintenance Manual

JABSCO & Series 1½ 80 SIZE UTILITY Pump

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

Installation, Operating, Maintenance and Safety Instructions JABSCO & Series 1 40 SIZE UTILITY Pump

Fan - Powered Terminal Unit Series Flow

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

Excellence in Level Measurement

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Clamping and drive module

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

Vent-Axia Sabre Sickle Roof Fans (VSR)

Monocellular centrifugal electro-pumps

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006

DELHOIST DOUBLE ACTING TELESCOPIC CYLINDERS Stoney Rise Road (P.O. Box 20), Devonport, Tasmania 7310

DCE 100 Series Dust Filter

SwingLift GB100 GAS BOTTLE CRANE

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

Melody 1 Platform Lift

ifan Copford Box Range

Operating and Maintenance Instructions. Station Road Clowne Chesterfield Derbyshire S43 4AB Tel: Fax:

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL RBK FRP FAN

LQLR Fan. Installation instruction. Outlet: Installation. Inlet:

ASSEMBLY INSTRUCTIONS L-LINE KTG ZMA0304GB

Tubular Centrifugal Fans

Installation, Operation and Maintenance Manual

AXIAL FANS Axis / Tubo OPERATION MANUAL

AC Commercial Fans Edition. ErP ready

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

User Manual. Studio Rail. Size Version

INTRODUCTION GENERAL GUIDELINES ATTACHING THE DRIVE PARTS

GL1200T Cut & Seal. (GL1200 Seal only)

Technical Data Series 1103D-33 G3. Diesel engine - Electropak rpm

Bifurcated Case Axial Fans (BIFA)

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

Operating Instructions

Transcription:

NALTF & NALTRF Belt Drive Installation and Maintenance The EMC Directive 2014/30/EU The Low Voltage directive 2014/35/EU Introduction The Nuaire NALTF and NALTRF Belt Drive Twinfan range consists of the following units: NALTF/NALTRF Plantroom/Roof in line mounted unit. NALTRF Plantroom/Roof bottom inlet unit. NALTRF Plantroom/Roof bottom/end inlet unit. (Larger sizes). Units are rectangular in section and the casing is manufactured from heavy gauge Aluzinc aluminium-zinc coated mild steel. A full size internally lined access panel is fitted to the top face and is fully detachable for inspection purposes. The motor plate and frames are supported on the base by resilient mountings allowing the fan unit to be operated without the need for separate anti vibration fan case mountings. The units incorporate two independent motors with high efficiency, forward curved centrifugal impellers running in metal scrolls. Taperlocked pulleys and wedge drive belts are employed. The fans discharge into a common outlet chamber through a shutter system that prevents blowback through the standby fan. The motors are manufactured to BS5000 and are suitable for three phase supply. Airflow and failure monitors are standard for sizes 9 to 15. All motors have Class F insulation and are suitable for operation in ambient temperatures up to 40 o C. 1.0 Handling Always handle the units carefully to avoid damage and distortion. Eyebolts are provided on some units for lifting. If mechanical aids are used to lift the unit, spreaders should be employed and positioned so as to prevent the slings, webbing etc. making contact with the casing. Correctly position slings to avoid twisting of the unit case and observe the centre of gravity before the final lift is made. Note: the weight of the unit from the rating plate. Figure 1. Lifting unit with slings via spreaders. 2.0 Dimensions Figure 2. NALTF and NALTRF-1 Units Dimensions Removable top E panel C Opposed outlet grilles C C A A Removable top panel A F E F B 50mm D dia Circular spigots (NALTF 9-17) Rectangular spigots (size NALTF 18-24) Unit A B C D dia E F NALTF9-10, NALTRF9-10 974 974 622 400 - - NALTF11-12, NALTRF11-12 1233 1233 701 500 - - NALTF13-17, NALTRF13-17 1430 1635 796 630 - - NALTF18-24, NALTRF18-24 2030 2313 1183-1200 700 Figure 3. NALTRF Bottom Inlet Units Dimensions Bottom inlet E F Control module located internally Spigot Unit A B C E F NALTRF9 to NALTRF10 974 974 622 457 229 NALTRF11 to NALTRF12 1233 1233 701 762 304 NALTRF13 to NALTRF17 1430 1635 796 889 381 Figure 4. NALTRF Larger Bottom/End Inlet Units Dimensions B B Bottom rectangular inlet spigot Louvred end outlet Rect Spigot Unit A B C E F NALTRF18 to NALTRF24 2030 2313 1183 1200 700 Nuaire: A Trading Division of Polypipe Limited Western Industrial Estate Caerphilly United Kingdom CF83 1NA T: 029 2088 5911 F: 029 2088 7033 E: info@nuaire.co.uk W: www.nuaire.co.uk 1

3.0 Installation The installation must be carried out by competent personnel in accordance with the appropriate authority and conforming to all statutory and governing regulations. Units must not be installed at an angle over 5 o from the horizontal (to ensure the backdraught shutters operate satisfactorily). Units must be installed with the access panel on top, never up-side-down. Units should always be positioned with sufficient space to allow removal of the access covers and subsequent removal of fan and motor assemblies etc. Ductwork connections must be airtight to prevent loss of performance. The method of mounting used is the total responsibility of the installer. The lower edge of the casing has an internal skirt allowing the unit to be located on an upstand or prefabricated curb if desired. The units must be securely screw fixed to the upstand/curb to prevent vibration and/or wind damage. It is the installers responsibility to drill the case to provide access for the electrical cables. Care should be taken not to damage internal components and the cable entry must be properly sealed. NOTE: on bottom inlet units the electrical cabling may be routed up through the bottom inlet spigot. Upstand Details Details of roof opening dimensions etc required and basic construction of a builders upstand etc are shown below for typical concrete and decking roof installations. Roof Opening Dimensions Figure 5. Testing after Installation Ensure that the Fan unit and any specified controls are fitted securely according to the instructions. Switch on the mains supply. Push the test button to run each fan and check that they run satisfactorily. If a switched live signal is used, activate this signal and check that the fan runs. De-activate the switched live signal and check the run-on-time; adjust if necessary. Adjust the maximum and minimum airflow (if required) by following the commissioning procedures. Prefabricated Curb CODES: NALPFC (typical) Manufactured in aluminium alloy these curbs will reduce design work and guarantee correct unit mounting when on site. Figure 6. Note: Upper faces of curb are fitted with robust sealing strip. Prefabricated curb dimensions Unit Prefab Code Curb Code A B C NALTF 9-10 NALPFC 4B 917 917 250 NALTF 11-12 NALPFC 5B 1173 1173 250 NALTF 13-17 NALPFC 6B 1374 1580 250 Typical Roof Upstand for NALTF 18-24 Figure 7. 2030 1183 165 louvre 50mm Spigot 680 700 Spigot 640 Curb 1550 min 1850 max 2313 1200 Spigot 700 Spigot 210 Unit Code Prefab Code A B C D E F G NALTF 9-10 NALPFC 4B 767 767 947 947 837 837 75 NALTF 11-12 NALPFC 5B 973 973 1203 1203 1064 1064 100 NALTF 13-17 NALPFC 6B 1169 1375 1399 1605 1268 1471 100 Note: Prefabricated curbs can be used to support internal or external units. 150 1200 Spigot Curb 2140 max 2

4.0 Electrical Details Isolation - Before commencing work make sure that the unit, and any control are electrically isolated from the mains supply. Run currents etc. 400V 3 Phase 50Hz Unit Code Speed Power f lc sc Weight rpm (kw) (amps) (amps) kg NALTF/TRF 9 1225 0.75 2.1 9.5 84.4 NALTF/TRF 10 1400 1.1 2.9 13.0 90.4 NALTF/TRF 11 1085 1.5 3.7 8.5 125 NALTF/TRF 12 1225 2.2 5.4 27.0 134 NALTF/TRF 13 1040 2.2 5.4 27.0 168.7 NALTF/TRF 14 1040 4.0 10.0 60.0 193.6 NALTF/TRF 15 1260 3.0 6.9 38.0 174.6 NALTF/TRF 16 1260 5.5 12.0 75.0 231.6 NALTF/TRF 17 1440 5.5 12.0 75.0 231.6 NALTF/TRF 18 700 5.5 12.0 75.0 730 NALTF/TRF 19 800 4.0 10.0 60.0 716 NALTF/TRF 20 800 11.0 23.0 154.0 794 NALTF/TRF 21 1000 5.5 12.0 75.0 730 NALTF/TRF 22 1000 11.0 23.0 154.0 794 NALTF/TRF 23 1100 11.0 23.0 154.0 794 NALTF/TRF 24 1200 11.0 23.0 154.0 794 NOTES: Because the run and start currents depend upon the duty and associated ductwork of an individual unit, the values quoted in the table are nominal. Run currents will be exceeded if the unit is operated with its cover removed. The unit must NOT run for more than 2 minutes in this condition. Electrical Installation Basic Layout Figure 8. Basic internal layout. Electrical Wiring Figure 9. Basic fan wiring diagram for NALTRF 9-15 and NALTF 9-15 only FAN UNIT Fan live applies to Direct Drive fans only (Link to be left in) Switched live overrun adjustment Fault indicating voltage free contacts N O Note: relay is N C energised if no fault is present COM i.e. COM - N O is connected if there is no fault SL L L N NAL-RFI Remote fan indicator (supplied) 230V Switched live signal. Remove L/SL link when using L3 L2 L1 N The fan will only operate when a 230V mains signal is present at the SL terminal. When the SL signal is switched off the fan will continuue to run for a preset period (1-60 minutes). Adjust the overrun time at the pot marked -SL RUNON. Ensure the local isolator (by others) also isolates the switched live. Controls for NALTF/NALTRF 9-15 The NALTF/NALTRF 9-15 fan units incorporate an integral auto-changeover controller which provides 12 hour duty share operation and automatic selection of the standby fan should the duty fan fail. Fault indication to an external device is provided via volt free contacts of a relay. Note: the relay is energised when no fault is present. Note: It is the responsibility of the installer to provide a suitable switchable local isolator for maintenance purposes etc. 400V 3 ph 50Hz Supply NALTF/NALTRF 16-24 Inclusive These fan units are supplied without any controls fitted. The electrical power is connected directly to the motor. Note that the motors are 5.5kW or higher and STAR-DELTA starting or a Soft Starter should be used in the motor control panel (by others). 3

Isolation - Before commencing work make sure that the unit, and any control are electrically isolated from the mains supply. 5.0 Maintenance - Fan unit Maintenance Intervals The first maintenance should be carried out three months after commissioning and thereafter at twelve monthly intervals. These intervals may need to be shortened if the unit is operating in adverse environmental conditions, or in heavily polluted air. Access to the unit internals is gained by removing the top cover(s). Motors Brush away any dust or dirt from the motor housings and ensure that the motor vents are unblocked. Bearings Lubrication is unnecessary as the motors are fitted with sealed for life bearings. Impellers Remove any dust and check that the impellers are securely fixed to the motor shafts. Take care not to disturb any balance weights fitted. Check sealed for life bearings for excessive wear. Figure 10. Shutter detail. Shutter Assembly Remove any dust and check that the shutters operate freely and that they seal the appropriate fan outlet effectively. Anti Vibration Motor Plate Mountings Each motor plate is supported on ten individual resilient mountings. Check that all the mountings are secure and in good condition. (See figure 11). Changing a Drive Belt To replace a belt, remove the two bolts from the motor mounting furthest from the fan and slacken the remaining two bolts. Lift the motor plate and remove the belt. Replacing the belt is the reverse of this procedure. Figure 12. Adjusting the Drive Belts (larger units). Adjusting Drive Belt Tension (larger units) All belt drive units incorporate belt tensioning devices. To adjust the belt tension, slacken the pinch bolt on the sides of the motor plate. Turn the adjusting bolt clockwise to tighten the belt and counter clockwise to loosen it. The drive should be tensioned until a slight bow appears in the slack side of the V belt when running under load. To check for correct tension, proceed as follows. 1. Measure the span length (See figure 12). 2. At the centre of the span, apply a force at right angles to the belt sufficient to deflect one belt 16mm for every metre of span length (see figure 12). The force required to deflect the V belt should be from 0.5kg to 0.8kg. 3. Tighten the pinch bolts. General Cleaning and Inspection Clean and inspect the exterior of the fan unit and associated controls etc. Remove the access panel from the fan unit. Inspect and, if necessary, clean the fan and motor assemblies and the interior of the case. If the unit is heavily soiled it may be more convenient to remove the fan/motor assemblies. If NuAire controls and or remote indicators are fitted, remove the covers and carefully clean out the interiors as necessary. Check for damage. Check security of components. Refit the access covers. General 1. Check that all fixings are tight. 2. Check sealing strips around the fan outlets are tight up against the bulkhead. 3. Check that duct connections are not leaking. Figure 11. Adjusting the Drive Belts (smaller units). Adjusting Drive Belt Tension (smaller units). To check the correct tension of a drive belt, apply a force at right angles to the centre of the belt span sufficient to deflect the belt 16mm for every metre of span length (see figure 11). The force required to deflect the V belt should be from 0.5kg to 0.8kg. 4

6.0 Replacement of Parts Drive belts are the only servicable items on these fan units. With time and fair wear and tear it may be necessary to replace fan assemblies or motors - consult the fan rating plate detail when ordering. Note: Isolate the Electrical Supply Remove the top access panel. Disconnect the wiring to the motor assembly. Remove the old unit. Replace the fan/ motor assembly. Re-connect the supply to the motor. Check for correct rotation and operation and replace the top access panel. Spare Parts When ordering spares please quote the serial number of the unit. This number will be found on the identification plate attached to the unit mounting frame. Please give a full description of the part required. 7.0 Warranty The unit has a one year warranty. The warranty starts from the date of delivery and covers faulty materials or workmanship and includes parts and labour. The labour element is subject to full, free and safe access to the equipment as recommended by the CDM regulations. This warranty is void if the equipment is modified without authorisation, is incorrectly applied, misused, disassembled, or not installed, commissioned and maintained in accordance with the details contained in this manual and general good practice. The product warranty applies to the UK mainland and in accordance with Clause 14 of our Conditions of Sale. Customers purchasing from outside of the UK should contact Nuaire International Sales office for further details. 8.0 After Sales Enquiries For technical assistance or further product information, including spare parts and replacement components, please contact the After Sales Department. Telephone 02920 858 400 5

DECLARATION OF INCORPORATION AND INFORMATION FOR SAFE INSTALLATION, OPERATION AND MAINTENANCE We declare that the machinery named below is intended to be assembled with other components to constitute a system of machinery. The machinery shall not be put into service until the system has been declared to be in conformity with the provisions of the EC Machinery Directive. Designation of machinery: BELT DRIVE TWINFAN Machinery Types: NALTF, NALTRF Relevant EC Council Directives: 2006/42/EC (Machinery Directive) Applied Harmonised Standards: BS EN ISO 12100-1, BS EN ISO 12100-2, EN294, EN60204-1, BS EN ISO 9001 Applied National Standards: BS848 Parts One, Two and Five Note: All standards used were current and valid at the date of signature. Signature of manufacture representatives: Name: Position: Date: 1) C. Biggs Technical Director 20. 07. 07 2) A. Jones Manufacturing Director 20. 07. 07 INFORMATION FOR SAFE INSTALLATION, OPERATION AND MAINTENANCE OF NUAIRE VENTILATION EQUIPMENT To comply with EC Council Directives 2006/42/EC Machinery Directive and 2014/30/EU (EMC). To be read in conjunction with the relevant Product Documentation (see 2.1) 1.0 GENERAL 1.1 The equipment referred to in this Declaration of Incorporation is supplied by Nuaire to be assembled into a ventilation system which may or may not include additional components. The entire system must be considered for safety purposes and it is the responsibility of the installer to ensure that all of the equipment is installed in compliance with the manufacturers recommendations and with due regard to current legislation and codes of practice. 2.0 INFORMATION SUPPLIED WITH THE EQUIPMENT 2.1 Each item of equipment is supplied with a set of documentation which provides the information required for the safe installation and maintenance of the equipment. This may be in the form of a Data sheet and/or Installation and Maintenance instruction. 2.2 Each unit has a rating plate attached to its outer casing. The rating plate provides essential data relating to the equipment such as serial number, unit code and electrical data. Any further data that may be required will be found in the documentation. If any item is unclear or more information is required, contact Nuaire. 2.3 Where warning labels or notices are attached to the unit the instructions given must be adhered to. 3.0 TRANSPORTATION, HANDLING AND STORAGE 3.1 Care must be taken at all times to prevent damage to the equipment. Note that shock to the unit may result in the balance of the impeller being affected. 3.2 When handling the equipment, care should be taken with corners and edges and that the weight distribution within the unit is considered. Lifting gear such as slings or ropes must be arranged so as not to bear on the casing. 3.3 Equipment stored on site prior to installation should be protected from the weather and steps taken to prevent ingress of contaminants. 4.0 OPERATIONAL LIMITS 4.1 It is important that the specified operational limits for the equipment are adhered to e.g. operational air temperature, air borne contaminants and unit orientation. 4.2 Where installation accessories are supplied with the specified equipment eg. wall mounting brackets. They are to be used to support the equipment only. Other system components must have separate provision for support. 4.3 Flanges and connection spigots are provided for the purpose of joining to duct work systems. They must not be used to support the ductwork. 5.0 INSTALLATION REQUIREMENTS In addition to the particular requirements given for the individual product, the following general requirements should be noted. 5.1 Where access to any part of equipment which moves, or can become electrically live are not prevented by the equipment panels or by fixed installation detail (eg ducting), then guarding to the appropriate standard must be fitted. 5.2 The electrical installation of the equipment must comply with the requirements of the relevant local electrical safety regulations. 5.3 For EMC all control and sensor cables should not be placed within 50mm or on the same metal cable tray as 230V switched live, lighting or power cables and any cables not intended for use with this product. 6.0 COMMISSIONING REQUIREMENTS 6.1 General pre-commissioning checks relevant to safe operation consist of the following: Ensure that no foreign bodies are present within the fan or casing. Check electrical safety. e.g. Insulation and earthing. Check guarding of system. Check operation of Isolators/Controls. Check fastenings for security. 6.2 Other commissioning requirements are given in the relevant product documentation. 7.0 OPERATIONAL REQUIREMENTS 7.1 Equipment access panels must be in place at all times during operation of the unit, and must be secured with the original fastenings. 7.2 If failure of the equipment occurs or is suspected then it should be taken out of service until a competent person can effect repair or examination. (Note that certain ranges of equipment are designed to detect and compensate for fan failure). 8.0 MAINTENANCE REQUIREMENTS 8.1 Specific maintenance requirements are given in the relevant product documentation. 8.2 It is important that the correct tools are used for the various tasks required. 8.3 If the access panels are to be removed for any reason the electrical supply to the unit must be isolated. 8.4 A minium period of two minutes should be allowed after electrical disconnection before access panels are removed. This will allow the impeller to come to rest. NB: Care should still be taken however since airflow generated at some other point in the system can cause the impeller to windmill even when power is not present. 8.5 Care should be taken when removing and storing access panels in windy conditions. Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and dimensions of equipment and the right is reserved to make such changes without prior notice. 6