PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.

Similar documents
PROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements.

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

S1 SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET

M SERIES TECHNICAL DATA INFORMATION PACKET

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

COMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners

IMMERSION FIRED HOT WATER BOILER

XL/LNXL SERIES. Installation, Operation, and Service Manual for Vertical Configuration

Model CBLE Boilers HP

FD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP

Boiler Burners For Commercial And Industrial Applications

The New Coen Micro-NOx

Power Flame Incorporated

CBLE HP. Boiler Book 05/2017

Eclipse Vortometric Burners Series HI

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

Model HDS and HDSX Burner

Model 4WI HP 4 Pass Wet-Back with Integral Burner

Model CBEX Elite HP

LC BURNER SERIES.

Low NOx Technology Seminar. The Gas Company April 30 th, 2003 Downey,CA. Presentation Overview

Weishaupt Low NOx Solutions for Boiler Applications

Converting to Natural Gas for MATs Compliance August 7, 2014

John Zink # United Kingdom

Emergency Generators & Fire Pump

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

CLEAVER-BROOKS. ProFire Burner. Operation, Maintenance, and Parts Manual. Addendum to:

info NO x emissions <15 ppm 4LN version gas burners (with Flue Gas Recirculation) Information on Ultra Low NO x gas burners

KINEMAX. Medium velocity gas or oil burners

MULTIFIRE. High temperature dual fuel burner

TGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:

1070 SERIES ULTRA LOW NO X

D/LND SERIES. Installation, Operation, and Service Manual

M/SERIES. Installation, Operation, Service, and Parts Manual

DATA SHEET. Model: TG4 Revision Date: September DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL


1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS

VALUPAK. Packaged gas burners


DATA SHEET. Model: TG3 Revision Date: September DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

TriOx Triple Air Staged Ultra Low NOx Burner

LP BURNER SERIES.

COMBUSTION RESEARCH AND TEST FACILITY

Doing more for clean environment and energy saving

1466 SERIES COLD AIR GAS/OIL BURNER

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

Achieving Ultra Low NO x Emissions in Boiler Burner Retrofits. Bill Gurski Rex Isaacs John Guarco

Hamilton 3VO Submittal

Capacities and Operating Data

Eclipse RatioAir Burners

Eclipse RatioAir Burners

Burner Company OIL GUNS. Bulletin IG-1. Bulletin OG-1A

Weishaupt oil burners Sizes 30 to 70 1/2003 CA

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING

KG7T (E and N Series)

IN-STOCK INVENTORY O-TYPE WATERTUBE BOILER O-TYPE BOILER - UP TO 75,000 PPH SPECIFICATIONS SCOPE OF SUPPLY

Q&A FOR Webinar on Electrical Basics & Boiler Wiring

No one comes close to matching the 20:1 and 15:1 turndown of our condensing Benchmark boilers.

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

7. SERVICING AND COMPONENT ADJUSTMENTS

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

Available in Upflow/Horizontal and Counterflow/Horizontal models

Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung. Dr.-Ing. Marco Derksen

Design and Application Details

Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency

Power Plant and Process Burners

Mitsubishi Hitachi Power Systems America. Coal to Gas Conversions

Table Of Contents. Profire M Burner. Gas, #2-5 Oil, #2-6 Oil, or Combination. Installation Operation Maintenance Parts

Retrofitting of Mitsubishi Low NOx System

KG7T (C and L Series)

Data /1/07 Eclipse RatioAir Burners Model RA0040

I.C.E. DIRECT FIRED MAKE-UP AIR UNITS

Aggregate Drying Burners ASTEC AGGREGATE DRYING BURNERS. For Hot Mix Asphalt Facilities

ZEECO BURNER DIVISION

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

C C A. Combustion Components Associates, Inc.

WAC Air Curtains Technical Guide

ICI Boiler NOx & SO 2

R&D on Oil-Burning, Environment - Friendly, High-Efficiency Boiler

First Correlating Revision No. 1-NFPA [ Section No ]

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

CONTROLS UPGRADE CASE STUDY FOR A COAL-FIRED BOILER

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

1032 SERIES LARGE CAPACITY DUAL FUEL OIL/GAS, AMBIENT OR PREHEATED AIR BURNER

OIL FIRED FURNACE REPLACEMENT PARTS MANUAL FLF085D36C FLF110D48C. Models: Contents. General Notes. Important

The World s First Flameless Crude Heater

PRICED BILL OF QUANTITIES Package : Air conditionning. Manhours (h) Unit (tariff) Discount Total Unit. Total. Material cost

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS

BBC Multi-fuel Combination Beta Burner

Multi-Position, Multi-Speed Gas Furnaces

Transcription:

PROFIRE xl Series burners 37.8 TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.

Innovative Technology. Superior performance a technician can trust. The ProFire XL series, suitable for large firetube and watertube applications, is offered in two standard configurations; vertical and horizontal. It s unique and precise air metering system permits accurate air-to-fuel ratios for maximum combustion efficiency. Through the use of innovative technology, the XL series offers high turndown on natural gas and light oil. Precise Oil Metering A unique design feature on ProFire XL series air atomizing oil burners, a V-port oil flow control valve is used for maximum capacity and precise oil control. Air & Steam Atomization A remote air compressor module provides air atomization. The module includes C-B s rotary vane, pressure lubricated air compressor, air/oil lubricating reservoir, oil level indicator, inlet air filter, air pressure adjusting valve and air pressure gauge. Plant air and steam atomization are also available. Parallel Positioning Unlike the single point control, parallel positioning systems use independent actuators for precise and repeatable metering of fuel and combustion air, properly proportioning firing cycle rate, which maintains combustion efficiency and saves energy. Hinged Rear Door Provides easy access to the nozzle, scanner, pilot and diffuser for inspection or removal. No disconnection of fuel or power lines required. High Turndown Up to 10:1 turndown with natural gas and 8:1 with the low NOx option. High turndown allows for reduced heat loss due to short cycling, faster response times to meet load demands and less mechanical cycling. Low Blower Motor HP Cleaver-Brooks utilizes an air fan with an air foil blade design which increases blower efficiency and lowers the blower motor horsepower, thereby increasing year-round electrical utility savings.

Low-NOx Configurations The ProFire XL series is offered in two standard configurations; vertical and horizontal. Vertical configurations support capacities ranging from 37.8 to 63.0 MMBTU, and horizontal configurations support capacities from 67.2 to 92.4 MMBTU. The standard and low-nox vertical and horizontal configurations are capable of burning natural gas, propane gas, air atomized No. 2 oil, as well as combination gas/no. 2 oil. Full modulation operation is standard and a parallel positioning system is required for burner management and combustion control. Burners Available to <30 PPM NOx (LNXL) XL/ LNXL Burner 1800/3600 RPM Combustion Fan motor horsepower is based on NOx and capacity requirement Air atomizing low pressure oil nozzle (steam atomization optional) V-port oil flow control valve is used for maximum capacity and precise oil flow control Parallel Positioning required for optimal control throughout the firing range Hinged Rear Door and Access Panels for easy access to internal components Gas Manifold on oil burners standard for easy upgrade to combination units Combustion Air Fan efficient airfoil blade design smoothly lifts airflow over the entire blade, resulting in less motor horsepower requirement and significant noise reduction when compared to standard force draft fans No. 2 Oil capability for back-up fuel (LNXL) Emissions Frame Model Range Boiler HP Capacities MBH GPH Mode of Operation Uncontrolled 1-3 378-924 900-2,200 37,800-92,400 270-660 Full Modulation <30 PPM 1-3 378-924 900-2,200 37,800-92,400 270-660 Full Modulation Note: A parallel positioning system is required for burner management and combustion control, consult factory for options. Fuel Gas, Oil, Comb. Gas & Comb. Parallel Positioning Required Required

Capacities and Ratings Uncontrolled Emissions Configuration (XLL, XLG, XLLG) Blower Motor HP 30 40 50 60 60 75 75 75 100 100 100 <30 PPM Low NOx Configuration (LNXLG, LNXLLG) Blower Motor HP 40 50 60 75 75 75 100 100 125 125 150 FGR Line Piping (in.) 14 14 14 16 16 16 16 18 18 20 20 Input is based on fuel Btu content and altitude of 2,000 feet or less. If altitude > 2,000 feet and < 8,000 feet, derate capacity 4% per 1,000 feet over 2,000. Consult factory for higher altitudes. Gas input is based on natural gas with 1,000 Btu/cu.ft., 0.60 gravity, 0 w.c. furnace pressure and the aforementioned conditions. Oil input based on 140,000 Btu/gal and the aforementioned conditions. Consult factory for 50Hz. applications. Contact the factory for shipping weight estimation.

Ultra-Low-NOx Configuration Burners The ProFire NTXL was designed and developed with a Flue Gas Recirculation system which has been proven to be the benchmark in the industry. Emissions reduction, fuel savings, performance, and reliability make the ProFire NTXL an excellent choice. The Cleaver-Brooks ProFire NTXL series burner offers natural gas, propane air mix, air atomized #2 oil, and combination gas and oil fuel options from 37.8 to 92.4 MMBTU per hour, with full modulation operation and parallel positioning for greater efficiency and cost savings. The ProFire NTXL is an ultra-low-nox burner capable of less than 9 ppm NOx emissions. ProFire NTXL 1800/3600 RPM Combustion Fan motor horsepower is based on NOx and capacity requirement Air atomizing low pressure oil nozzle (steam atomization optional) V-port oil flow control valve is used for maximum capacity and precise oil flow control Parallel Positioning required for optimal control throughout the firing range Hinged Rear Door and Access Panels for easy access to internal components Gas Manifold on oil burners standard for easy upgrade to combination units Combustion Air Fan efficient airfoil blade design smoothly lifts airflow over the entire blade, resulting in less motor horsepower requirement and significant noise reduction when compared to standard force draft fans Available to <9 PPM NOx No. 2 Oil capability for back-up fuel Frame Model Range Boiler HP Capacities MBH GPH Mode of Operation Fuel Parallel Positioning 1-3 378-924 900-2,200 37,800-92,400 270-660 Full Modulation Gas, Comb. Required Note: A parallel positioning system is required for burner management and combustion control, consult factory for options.

Capacities and Ratings Uncontrolled Emissions Configuration (XLL, XLG, XLLG) Blower Motor HP 30 40 50 60 60 75 75 75 100 100 100 Less than 30 ppm Low NOx Configuration (LNXLG, LNXLLG) Blower Motor HP 40 50 60 75 75 75 100 100 125 125 150 FGR Line Piping (in.) 14 14 14 16 16 16 16 18 18 20 20 Less than 15 ppm and less than 9 ppm Ultra-Low-NOx Configuration (NTXLG, NTXLLG) Blower Motor HP 50 50 75 100 100 100 125 150 150 200 200 Furnace Pressure ( w.c.) 6.8 8.3 8.7 8.9 9.3 9.6 11.1 9.5 9.5 10.0 10.1 FGR Line Piping (in.) 14 14 14 16 16 16 16 18 18 20 20 Input is based on fuel Btu content and altitude of 2,000 feet or less. If altitude > 2,000 feet and < 8,000 feet, derate capacity 4% per 1,000 feet over 2,000. Consult factory for higher altitudes. Gas input is based on natural gas with 1,000 Btu/cu.ft., 0.60 gravity, 0 w.c. furnace pressure and the aforementioned conditions. Oil input based on 140,000 Btu/gal and the aforementioned conditions. Consult factory for 50Hz. applications. Contact the factory for shipping weight estimation. Packaged Burner Systems 351 21st Street, Monroe, WI 53566 USA 608.325.3141 info@cleaverbrooks.com cleaverbrooks.com Printed in the USA 2011 Cleaver-Brooks, Inc CB-8262 04/12