ED EXPOSIO PROOF IHT Explosion Proof Outdoor ED uminaire (C SERIES) This ED Explosion Proof ight can provide general illumination in hazardous locations such as oil refineries, gasoline loading docks, distilleries, pumping stations, mines, vessels, paint manufacturing plants and other high humidity, high temperature, dusty locations. DIMESIOS CERTIFICATIOS & RATIS 9.8 ø6 6.5.7 6. EMA X, IP66 U598/U589A/U8 CSA C. o. 7/o.50.0 Class I, Division, roups C,D Class I, Division, roups A,B,C,D Class II, Division, roups E,F, Class II, Division, roups E,F, Class III IECEX ATEX 70 FEATURES COMMO TECHICA DATA Copper free aluminum High vibration resistance IP67 Waterproof Reduces energy consumption up to 60% Cree ED Chips Mean Well driver Wide and narrow optics for uniform illumination Surface mounting and pendant installations 0 Year Manufacturer s Warranty Color Temperature 000K to 6500K CRI > 80 Beam Angle 0º Operation Temperature -0ºC to 60ºC Efficiency More than 0 PW Input Voltage AC00-77V/00-80V Frequency 50-60Hz Power Factor More than 0.90 Rated ife 50,000 hours ED Type Cree ED Chips WARRATY This product has a warranty for a period of 5 years from the date of purchase. The warranty is invalid in the case of improper installation, tampering, or removal of the Q.C. date label. Installation in an improper working environment or installation not according to the current edition of the ational Electric Code also invalidates the warranty. Should this product fail during the warranty period, it will be replaced free of charge, subject to correct installation and return of the faulty unit. ames does not accept responsibility for any installation costs associated with the replacement of this product. This warranty is in addition to the statutory rights in the country of purchase. ames reserves the right to alter specifications without prior notice. 50 Old Peachtree Rd W Suite 0 Suwanee, A 00 678-608-75 IFO@get.com www.get.com 07 ighting. All Rights Reserved //7
ED EXPOSIO PROOF IHT Explosion Proof Outdoor ED uminaire (C SERIES) PRODUCT SPECIFICATIO Product umber Wattage Color Beam Angle umens Input Voltage EX- 60W CXYZA 60W 000K-5000K 0º 8,00 AC00-77V/AC00-80V EX- 80W CXYZA 80W 000K-5000K 0º,00 AC00-77V/AC00-80V EX- 00W CXYZA 00W 000K-5000K 0º,000 AC00-77V/AC00-80V EX- 0W CXYZA 0W 000K-5000K 0º 6,800 AC00-77V/AC00-80V EX- 50W CXYZA 50W 000K-5000K 0º,000 AC00-77V/AC00-80V EX- 80W CXYZA 80W 000K-5000K 0º 5,00 AC00-77V/AC00-80V EX- 00W CXYZA 00W 000K-5000K 0º 8,000 AC00-77V/AC00-80V EX- 0W CXYZA 0W 000K-5000K 0º,600 AC00-77V/AC00-80V ORDERI UIDE EX 60W/80W/00W/0W/ 50W/80W00W/0W C D/ 000K-5000K 0º C/Blank Company Code Wattage Series X= Dimming Options Y= CCT Z= Beam Angle A= ong lass Cover/ one IHT DISTRIBUTIO ight Dis tribution P attern 0W ight intens ity c urv e P lane illuminanc e c urv e 05 05 C5 C80 C5 E( 0 ) 8059 90 90 0.5.0 E( C0) 56.9 67 75 75 E( 0 ) 955.0. E( C0) 56.9 80 60 60 E( 0 ) 6007 000.5.0 E( C0) 56.9 580 C70 C90 5 8000 5.0.6 E( 0 ) 9 E( C0) 56.9 0 000 E( 0 ) 7 000.5 6.0 E( C0) 56.9 65 8000 000 0 5 0 5 0.0 7.0 E( 0 ) 50 E( C0) 56.9 95 C5 C0 C5 cd C0 - C80 C90 - C70 59 l m Dis tance [ m] P yramis D iamete [ m] illuminance [lx] C0 - C80 ( Half divergence angle:.8 ) cd/m² g = 5 5.0 g = 6 5.0 g = 7 5.0 CAUTIO Risk of fire- make sure power is OFF before installation. Risk of electric shock- make installation with gloves. All wiring needs to be performed per ational Electrical Code and local code by a qualified electrician. These lamps can be used with a light dimmer. High temperatures inside luminaire. Male certain line voltage corresponds with ballast s primary voltage. If the lamp or luminaire exhibits undesirable operation (i.e. buzzing, flickering, etc.), immediately turn off power and remove the lamp from luminaire and contact manufacturer. uminaires should not be installed in narrow space to guarantee enough air convection. Do not make mass installation before sample testing. 50 Old Peachtree Rd W Suite 0 Suwanee, A 00 678-608-75 IFO@get.com www.get.com 07 ighting. All Rights Reserved PREIMIARY
ISTAATIO ISTRUCTIOS Explosion Proof Outdoor ED uminaire (C SERIES) Important READ ISTRUCTIOS CAREFUY BEFORE ISTAI. KEEP THIS ISTRUCTIOS FOR FUTURE REFERECE Fixtures must be wired in accordance with the ational electrical code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE ISTAED I ACCORDACE WITH THE APPICABE ISTAATIO CODE BY A QUAIFIED EECTRICIA WHO IS FAMIIAR WITH THE COSTRUCTIO AD OPERATIO OF THE PRODUCT AD THE HAZARDS IVOVED. WARI: Risk of fire or electric shock. High bay ight installation requires knowledge of luminaires and electrical systems. If not qualified,do OT try to install. Please contact an electrician. WARI: Risk of fire or electric shock. Suitable for wet locations. Make sure the power is off permier to install. WARI: Risk of fire or electric shock. Suitable for non-insulated surface and frame.do OT cover fixture with insulation liner or similar material. WARI: DO OT install in unstable, loose or breakable surfaces. WARI: DO OT let objects impact or exert force on the surface of the fixture. Installation and Electrical Connection! WARI RISK OF FIRE,EECTRIC SHOCK OR PERSOA IURY Before installation,turn power off. The specific steps of installation (Ceiling mounted) Flexible metal conduit -Fixing screw. Take the fixture and accessory out from cartoon box, tighten x angle holder screw as Fig... Flexible metal conduit install and tighten with the fixture.. Drill x hole as Fig., the distance can be 75~5mm, fixing Ø0~ expansion screws and bracket on ceiling.. Connect the AC cable, Black cable joins to, white cable joins to, green cable joins to grounding. 50 Old Peachtree Rd W Suite 0 Suwanee, A 00 678-608-75 IFO@get.com www.get.com 07 ighting. All Rights Reserved //7
Installation and Electrical Connection The specific steps of installation (Wall mounted) Flexible metal conduit -Fixing screw. Take the fixture and accessory out from cartoon box, tighten x angle holder screw as Fig... Flexible metal conduit install and tighten with the fixture.. Drill x hole as Fig., the distance can be 9~0mm, fixing Ø0 expansion screws and bracket on wall. The specific steps of installation (Pole mounted). Connect the AC cable, Black cable joins to, white cable joins to, green cable joins to grounding. or. Take the fixture and pole accessory out from cartoon box, tighten pole as Fig.. (inear pole). Connect the AC cable to installation box, Black cable joins to, white cable joins to, green cable joins to grounding. Chain of balance. Install the installation box to the wall or ceiling as FIg.. Tighten the pole to the box, and adjust the chain of balance. Install the fixture to the long pole after cable connecting. 50 Old Peachtree Rd W Suite 0 Suwanee, A 00 678-608-75 IFO@get.com www.get.com 07 ighting. All Rights Reserved PREIMIARY
Installation and Electrical Connection The specific steps of installation (Hook mounted). Take the fixture and accessory out from cartoon box as Fig... Through the cable to the hook and Fig... Drill expansion screw hole and install it, and hang the chain as Fig... Hang the fixture to the hook as above, connect the AC cable, Black cable joins to, white cable joins to, green cable joins to grounding. 50 Old Peachtree Rd W Suite 0 Suwanee, A 00 678-608-75 IFO@get.com www.get.com 07 ighting. All Rights Reserved PREIMIARY