F-1500 SERIES INSERTION TURBINE FLOW METER

Similar documents
F-2700 SERIES INSERTION VORTEX FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER

F-2500 SERIES VORTEX METER

VIM20 Vortex Insertion Flowmeter

Armstrong In-Line and Insertion Vortex Flow Meters

Multivariable Vortex Flow Meter

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

Vortex Flowmeter Model DVE

Multivariable Vortex Flow Meter

VLM20 In-line Vortex Flowmeter

RIM20 Rotor Insertion Flowmeter

The readings you need, right where you need them. AX Series Vortex Meters

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

VIM20 Vortex Insertion Flowmeter

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

VIM20 Vortex Insertion Flowmeter

The readings you need, right where you need them. AX Series Vortex Meters

Vortex Flow Meter Model DVH

F-2600 & F-2700 Series Vortex Flow Meter Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

TURBINE FLOW METER SELECTION GUIDE

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

ISTEC MAGNETIC METERS

Low Profile Insertion Vortex

Hot Tap Insertion Vortex

VORTEX IN-LINE FLOW METERS

Model FVP General Specification. Flanged Vortex Plate. Product Features

Vortex In Line Flow Meter

Vortex Plate. Model VP General Specification. Product Features

Vortex In Line Flow Meter

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

DW PADDLE-BELLOWS FLOWMETER & SWITCH

220 Series Innova-Flo o

DW PADDLE-BELLOWS FLOWMETER & SWITCH

VorTek Series M22, M23 and M24 Pro-V Vortex Volumetric and Mass Flow Meters. Instruction Manual

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

VersaFlow Vortex 100 Vortex Flow Meter Specifications

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Instruction Manual Vortex Flow Meter DVH / DVE

mass flowmeter for compressed air

Transmitting Transducer. Gas/Air Velocity Range:

NC State University Design and Construction Guidelines Division 23 Energy Management

F-5100 Insertion Thermal Mass Flow Meter Installation and Operation Guide

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

flow measurement solutions RIM10 series rotor insertion flowmeters

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

UTM10 Series Ultrasonic Transit-time Flowmeters

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

240/241 Series Vortex Volumetric and Mass Flow Meters. Instruction Manual

GE Sensing. PanaFlow MV. Vortex Flowmeter. User s Manual

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters. Instruction Manual

Ultra Mag SUBMITTAL PACKAGE

DVH / DVE. Vortex Flow Meter. Instruction Manual. Page 1 of 102

Vortex Eggs Delta Flowmeter

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Mass Flow Meters. Instruction Manual

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

M3500 Industrial Pressure Transmitter

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Range of Ultrasonic Flowmeters.

imag 4700 SERIES FLANGED MAGMETER

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

Full Profile Insertion

mass flowmeter for compressed air

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Rosemount 8800D Series Vortex Flowmeter

Thermal Mass Flow Meter (Series MST)

SIGNET 7002 Vortex Flow Sensor ENGLISH

STEEMCO-MAS Flowmeter for Steam

G2 Industrial Grade Meters

STEEMCO Flowmeter for Steam

RCM - Direct Reading Flowmeters

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

KDM ARMORED FLOW METER & SWITCH

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Electromagnetic Flowmeters. Product Overview.

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

Sierra Series 240 and 241 Innova-Mass Multi-Parameter Vortex Mass Flow Meters. Instruction Manual

Rosemount 8800D Series Vortex Flowmeter

FT-3100 ONICON. Inline Electromagnetic Flow Meter Installation and Operation Manual. Flow and Energy Measurement

F-5400 Insertion and Inline Thermal Mass Flow Sensor Installation and Operation Guide

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

Mobrey MSM400 Ultrasonic sludge density measurement system

ONICON Flow and Energy Measurement

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Transcription:

F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F (232 C) standard 850 F (454 C) optional Compressed air Industrial gases CALIBRATION Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications, the pitch of the turbine rotor is selected to match the expected steam flow velocity range in the pipe. This optimizes the operating range of the flow meter for the application. DESCRIPTION MADE IN THE USA The ONICON F-1500 Series Insertion Turbine Flow Meter is a flexible design that delivers accurate, reliable flow measurement in a wide variety of applications. The integral temperature sensor and optional integral pressure sensor allow for direct mass flow measurement in steam and compensated flow measurement in compressed air and gases. A volumetric flow version of the meter is also available for liquid flow applications. ONICON insertion style turbine meters for steam and gas flow are provided with rotors that are optimized for the expected flow range in the pipe. This makes them ideal for retrofit applications where low flow rates are often the norm. They can also be installed without disrupting flow, and they are priced independent of the pipe size. This makes them very cost effective option. A version of the F-1500 with temperature and optional pressure compensation is available as a DC loop powered (2-wire) device with analog and pulse outputs. Optional external DC and AC powered versions of the meter are also available. These versions offer additional options for serial communications and additional analog, pulse, frequency and alarm outputs. Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration accompanies every meter. FEATURES Mass flow measurement from a single instrument Improved flow operating range when compared to insertion vortex meters Interchangable rotors optimize meter performance for the expected flow range Integral 1,000 Ω platinum RTD for precise temperature measurement Optional integral pressure transducer for accurate pressure readings at the meter location DC loop powered operation Advanced signal processing algorithms ensure stable flow readings and reject noise Easy-to-install meter arrives fully programmed and ready to use Optional multi-analog output versions available HART serial communication Optional BACnet MS/TP or MODBUS RTU RS485 serial communication GENERAL SPECIFICATIONS ACCURACY Steam and gases Reynolds Number 10,000 Percent of reading accuracy to within: ± 1.5% for steam and gases (volumetric) ± 2.0% for steam and gases (mass) ± 0.1% Volumetric Flow Rate Repeatability ± 0.2% Mass Flow Rate Repeatability Liquids ± 1.2% for liquids (volumetric) ± 1.5% for liquids (mass) ± 0.1% Volumetric Flow Rate Repeatability ± 0.2% Mass Flow Rate Repeatability 0995-2 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 www.onicon.com sales@onicon.com 03-15

EXIT ENTER GENERAL SPECIFICATIONS (cont.) VELOCITY RANGE Maximum velocity, liquid: 30 ft/s (9 m/s) Minimum velocity, liquid: 0.5 ft/s (0.15 m/s) Maximum velocity, gas or steam: 43 to 205 ft/s (13 to 62 m/s) depending on rotor pitch Minimum velocity, gas or steam ft/s (m/s): 3.5 to 12 ft/s (1 to 3.7 ms/s) depending on rotor pitch SENSING METHOD Axial mounted rotating turbine utilizing inductive sensing Integral 1,000 Ω platinum RTD (optional) provides instantaneous temperature Integral pressure transducer (optional) provide instantaneous pressure OPERATING TEMPERATURE RANGE Ambient: -40 F (-40 C) to +140 F (+60 C) Process: -67 F (-55 C) to +450 F (+232 C) Optional high process temperature range -488 F (-289 C) to +850 F (+454 C) MAXIMUM OPERATING PRESSURE Flange rating or 1500 psi (103 bar) PRESSURE LOSS Pressure loss varies with meter size and flow rate. Please contact ONICON for detailed information. CONNECTION TYPE NPT threads with packing gland 2" ANSI Class 150 Flange with packing gland 2" ANSI Class 300 Flange with packing gland MATERIALS Wetted Metal Parts 316L stainless steel Electronics Enclosure: Epoxy painted aluminum INPUT POWER OPTIONS Loop Power: 14-36 VDC, 22 ma maximum current Optional External DC Power: 18-36 VDC, 300 ma maximum current Optional External AC power: 100-240 VAC 50/60 Hz, 5W. maximum power ENCLOSURE NEMA 4X (IP66) DISPLAY 2-line, 16 character alphanumeric LCD with backlighting option. Standard saturated steam display menu provides: Mass Flow Rate, Temperature, Pressure (calculated), Mass Total and Alarms (if active). Optional remote mount transmitter version available (Standard cable length 50 ft., maximum 150 ft.) OUTPUT SIGNALS PROVIDED DC loop powered version Analog Rate: 2-wire, 4-20 ma, 14-36 VDC, maximum loop resistance = RL ((Vsupply - 12 V) /.020 A) Totalization: 2-wire open collector scaled pulse, 50 ms duration, 5-36 VDC and 40 ma / 320 mw maximum Frequency: 2-wire open drain FET, 10 khz maximum frequency, 5-36 VDC and 40 ma / 200 mw maximum Digital: HART serial communications Optional backlight connection: Requires external 12-36 VDC power supply, 35 ma maximum current Optional DC or AC powered version Analog Rate: Up to (3) 2-wire, 4-20 ma, 14-36 VDC, maximum loop resistance = RL ((Vsupply - 12 V) /.020 A) Totalization: (1) 2-wire open collector scaled pulse, 50 ms duration, 5-36 VDC and 40 ma / 320 mw maximum Frequency: (1) 2-wire open drain FET, 10 khz maximum frequency, 5-36 VDC and 40 ma / 200 mw maximum Alarm: Up to (3) opto-coupled relay alarm outputs Digital: HART serial communications Optional on DC or AC powered version BACnet MS/ TP or MODBUS RTU RS485 serial communications in place of HART Note: Specifications subject to change without notice. REMOTE MOUNT INSTALLATION DIMENSIONS 2.1 in 3.0 in 5.0 in 8.3 in 5.7 in 2500 GPM 3.0 in REMOTE CABLE, 50 FT STANDARD LENGTH 5.0 in 0.6 in 2.8 in REMOTE ELECTRONICS OPTION AVAILABLE ON ALL MODELS.34 in DIA. U Bolt Provided F-1500 Series Insertion Turbine Flow Meter Catalog Sheet 03/15-0995-2 Page 2

FLOW METER OPERATING RANGES Meter Flow Rates for Saturated Steam Minimum and Maximum Saturated Steam Flow Rates @ Specific Operating Pressures Nominal Diameter in inches Pressure (psig) Density (lb/ft3) Insertion Meter Flow Rates in lb/hr Nominal Diameter (in), Schedule 40 5 15 50 75 0.0491 0.0721 0.1496 0.2036 Rotor R10 R25 R40 R10 R25 R40 R10 R25 R40 R10 R25 R40 3" 4" 6" 8" 10" 12" 14" 16" lbs/hr Minimum 90 36 25 109 44 31 158 65 45 185 76 52 Maximum 1405 540 287 2073 797 424 4337 1672 890 5922 2284 1217 Minimum 158 64 45 192 78 54 279 114 79 326 133 92 Maximum 2464 948 504 3635 1399 745 7602 2932 1562 10378 4005 2135 Minimum 373 152 105 453 185 128 657 268 186 768 314 218 Maximum 5790 2230 1187 8539 3291 1753 17847 6891 3673 24355 9410 5018 Minimum 660 270 187 802 328 228 1162 476 330 1359 556 386 Maximum 10227 3942 2098 15078 5816 3098 31499 12170 6491 42977 16616 8865 Minimum 1057 432 300 1284 526 365 1860 762 529 2175 891 619 Maximum 16342 6302 3357 24089 9298 4955 50305 19447 10375 68622 26546 14169 Minimum 1551 635 441 1870 766 532 2708 1110 771 3165 1298 902 Maximum 23736 9162 4883 34976 13512 7205 72999 28244 15078 99557 38544 20585 Minimum 1892 775 538 2299 942 654 3328 1365 948 3889 1596 1109 Maximum 29115 11246 5997 42891 16581 8847 89476 34642 18502 122006 47266 25255 Minimum 2536 1039 722 3081 1264 878 4459 1831 1273 5211 2141 1489 Maximum 38897 15044 8029 57279 22170 11838 119399 46278 24736 162762 63121 33752 Nominal Diameter in inches 3" 4" 6" 8" 10" 12" 14" 16" Pressure (psig) Density (lb/ft3) 100 150 200 300 0.2569 0.3627 0.4680 0.6791 Rotor R10 R25 R40 R10 R25 R40 R10 R25 R40 R10 R25 R40 lbs/hr Minimum 209 85 59 249 101 70 283 116 80 342 140 97 Maximum 7490 2890 1540 10608 4097 2184 13719 5301 2827 19966 7721 4120 Minimum 367 150 104 437 179 124 497 203 141 601 246 171 Maximum 13123 5068 2702 18583 7181 3830 24028 9290 4957 34961 13528 7222 Minimum 864 354 245 1030 421 293 1172 480 333 1415 580 403 Maximum 30791 11902 6350 43586 16861 8999 56341 21807 11643 81946 31743 16958 Minimum 1529 626 435 1821 746 518 2073 850 590 2503 1026 713 Maximum 54325 21014 11216 76881 29761 15892 99362 38486 20558 144481 56008 29934 Minimum 2447 1003 697 2914 1195 831 3316 1360 945 4004 1643 1142 Maximum 86731 33568 17923 122718 47533 25391 158579 61458 32842 230539 89422 47810 Minimum 3561 1461 1015 4240 1741 1210 4825 1981 1377 5824 2393 1664 Maximum 125807 48732 26034 177963 68985 36871 229926 89178 47681 334180 129717 69392 Minimum 4375 1796 1249 5210 2140 1488 5927 2435 1693 7154 2941 2045 Maximum 154154 59750 31935 218021 84564 45218 281645 109300 58464 409278 158953 85066 Minimum 5861 2409 1675 6977 2869 1996 7937 3265 2271 9578 3942 2743 Maximum 205605 79772 42668 290706 112863 60393 375467 145841 78064 545477 212020 113540 F-1500 Series Insertion Turbine Flow Meter Catalog Sheet 03/15-0995-2 Page 3

STRAIGHT PIPE RUN Typical Installation Flow Direction 2 diameters Upstream straight pipe run to flow straightener *Minimum upstream straight pipe run to first obstruction Minimum downstream straight pipe run = 5 diameters Obstruction Single bend preceded by 9 diameters of straight pipe *Minimum Upstream Straight Pipe Run Requirements Straight pipe run without flow straightener Straight pipe run to flow straightener 10 Dia NA Outflowing tee 10 Dia NA Pipe size reduction before meter 10 Dia NA Single bend preceded by 9 diameters of straight pipe 15 Dia 8 Dia Expansion before meter 20 Dia 8 Dia Multiple bends out of plane 30 Dia 13 Dia Partially open valve 30 Dia 13 Dia Control valve / P.R.V. 50 Dia 23 Dia F-1500 Series Insertion Turbine Flow Meter Catalog Sheet 03/15-0995-2 Page 4

FLOW METER OPERATING RANGES (CONT.) Flow Meter Rates for Water Water Minimum and Maximum Flow Rates Rate Nominal Pipe Size 2 3 6 8 12 16 24 GPM Min 5 12 54 109 247 386 877 GPM Max 314 691 2701 4678 10575 16524 37950 AVAILABLE PRESSURE TRANSDUCERS Full Scale Operating Pressure Maximum Overrange Pressure PSIa PSIa 30 60 100 200 300 600 500 1000 1500 2500 F-1500 Series Insertion Turbine Flow Meter Catalog Sheet 03/15-0995-2 Page 5

EXIT 2500 GPM ENTER METER DIMENSIONS & WEIGHTS Retractor Required for Applications Over 50 PSIG 8.0 in (203 mm) 5.0 in (127 mm) 3.0 in (76 mm) A* Pressure Transducer Housing (empty on some models) Orientation Lever 3/4 NPT Conduit Entry Electronics Enclosure Stem Stem Clamp Packing Gland 2 inch Male NPT 2 inch Male NPT B max. 2 inch Mounting Flange Depth Marker Arrow 8.0 in (203 mm) Turbine Sensor Head * This dimension is the same for integral and remote mount meters. Upper Retractor Bracket * This dimension is the same for integral and remote mount meters. Stanchion Scribe Mark Removable Insertion Tool Stem Lock Bolt (Center) Sensor alignment pointer Stem Stem clamp nuts Stem clamp bolts Packing gland nuts (covered by stem clamp) Lower Retractor Bracket Stem housing Mounting Option in (mm) Standard Length Extended Length A B A B Male NPT 40.0 (1016) 20.7 (526) 52.0 (1321) 32.7 (831) ANSI Class 150 Flange 40.0 (1016) 20.3 (516) 52.0 (1321) 32.3 (820) ANSI Class 300 Flange 40.0 (1016) 20.3 (516) 52.0 (1321) 33.1 (841) APPROXIMATE WEIGHT, LB (KG) SL EL NPT 16 (7.1) 17 (7.6) Class 150 21 (9.4) 22 (9.9) Class 300 25 (11.3) 26 (11.8) Add 11 LB (5 KG) for remote electronics Add 9 LB (4.1 KG) for retractor Turbine Sensor Head F-1500 Series Insertion Turbine Flow Meter Catalog Sheet 03/15-0995-2 Page 6

F-1500 SERIES ORDERING INFORMATION Insertion Turbine Meter Codification = F-1500-ABCD-EFGH A = Connection Type 0 = 2 Male NPT threads with retractor 1 = 2 ANSI class 150 flange with retractor 3 = 2 ANSI class 300 flange with retractor 6 = 2 ANSI class 600 flange with retractor 7 = 2 Male NPT threads without retractor ( 50psig maximum pressure) 8 = 2 ANSI class 150 flange without retractor ( 50psig maximum pressure) 9 = 2 ANSI class 300 flange without retractor ( 50psig maximum pressure) B = Integral or Remote Mount Transmitter 1 = Integral Mount 2 = Remote Mount C = Temperature / Pressure Compensation 0 = Integral temperature compensation 1 = Integral temperature & pressure sensor, 30 psia maximum 2 = Integral temperature & pressure sensor, 100 psia maximum 3 = Integral temperature & pressure sensor, 300 psia maximum 4 = Integral temperature & pressure sensor, 500 psia maximum 9 = None D = Rotor Type (nominal range) 0 = Liquid 1 = R40 (steam or gas) 2 = R30 (steam or gas) 3 = R25 (steam or gas) 4 = R20 (steam or gas) 5 = R15 (steam or gas) 6 = R10 (steam or gas) E = Input Power 0 = Loop powered (Only available with Output Signals option F=0) 1 = External 12-36 VDC powered 2 = External 85-240 VAC powered F = Output Signals 0 = 4-20mA output*, pulse output & frequency output 1 = 4-20mA output, pulse output & frequency output, alarm output & MODBUS 2 = 4-20mA output, pulse output & frequency output, alarm output & BACnet 3 = (3) 4-20mA outputs, (3) alarm outputs, (1) pulse output (1) frequency output & MODBUS 4 = (3) 4-20mA outputs, (3) alarm outputs, (1) pulse output (1) frequency output & BACnet 5 = (3) 4-20mA outputs*, (3) alarm outputs, (1) pulse output (1) frequency output 6 = 4-20mA output*, pulse output & frequency output, alarm output G = Maximum Operating Temperature 0 = 450 F 1 = 850 F H = Energy Meter 0 = None 1 = Gross energy meter 2 = Net energy meter (requires additional remote temperature sensor.) * Available with HART serial communications REMOTE TEMPERATURE SENSOR AND THERMOWELL INSTALLATION KIT (Required for Net Energy Meter) Part Number Description 20100 Remote Temperature Sensor, 1,000 Ohm 4-wire Class A Platinum RTD 20101 Remote Thermowell Kit for 1½" Welded Steel Pipe 20102 Remote Thermowell Kit for 2-5" Welded Steel Pipe 20103 Remote Thermowell Kit for 6-14" Welded Steel Pipe Note: Net energy meter requires 1 temperature sensor and 1 thermowell installation kit sized to pipe. F-1500 Series Insertion Turbine Flow Meter Catalog Sheet 03/15-0995-2 Page 7