Hot dipped galvanized. Optional Bolts/Nuts: (Available in imperial size bolts and nuts only.)

Similar documents
QuickVic Rigid Coupling for Steel. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE GROOVED COUPLINGS

Housing Coating: Orange enamel. Hot dipped galvanized. Optional Bolts/Nuts: (Available in imperial size bolts and nuts only.)

Lenntech Tel Fax

Style 99 Roust-A-Bout Couplings

Size Inches UL ULC FM. Pipe Sch.

SEE VICTAULIC PUBLICATION FOR DETAILS

Vic-Strainer WARNING. System No. Submitted By Spec Sect Para Location Date Approved Date IPS CARBON STEEL PIPE - GROOVED ACCESSORIES SERIES 730

11.02 Mechanical-T Bolted Branch Outlets

08.08 Vic-Check Valves

EMCO Corporation Waterworks is not responsible for any errors and discrepencies in the products depicted herein. Information is provided directly

Stainless Steel Pipe System. System No. Submitted By Spec Sect Para Location Date Approved Date TEMPERATURE ( F/ C)

REQUEST PUBLICATION 18.11

Victaulic Suction Vibration Isolation Pump Drop Series 337 Korea Only

Couplings. Ductile Iron Housing Specifications. Coatings. Gasket Specifications. Bolt/Nut Specifications

Victaulic Discharge CBV Vibration Isolation Pump Drop Series 383/383G

Model 7706 Reducing Coupling. Deg. Axial Displacement

Style 234 Restrained Flexible Single-Gasket Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Series 706 Butterfly Valves (300 PSI/2065 kpa)

Series W706 AGS Butterfly Valves (300 PSI/2065 kpa)

GROOVED COUPLINGS - STANDARD FLEXIBLE Model 101

08.12 Vic-Plug Balancing Valve

Series 709 Butterfly Valves (175 psi/1270 kpa)

Series W709 AGS Butterfly Valves (175 psi/1270 kpa)

B NPT. Dimensions Inches/millimeters

Pressfit System for Carbon Steel Pipe

08.20 VIC -300 MasterSeal Butterfly Valves

Style Flange Adapter

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

*Applies to 6 x 4" No. 650 Reducer only. C to E. No No º Elbow Approx. Wgt. Each Lbs. kg. C to E Inches mm JOB/OWNER CONTRACTOR ENGINEER

Product Submittals for Project

FIG Gruvlok Flange Adapter

Operators: Lever Handle: 1 1/2 3"/40 80 mm Carbon steel, zinc plated, plastic grip. 4 & 6"/100 & 150 mm Carbon steel, enamel paint

SJ-300N. Model SJ-300N-L Butterfly Valve with Lever Handle Max. Working Pressure (CWP)* PSI Bar Dimensions A B C D E in.

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

STAINLESS STEEL SYSTEMS

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Model C10 / C11 / C20 / C60 Grooved Fitting For Copper Tubing Nominal Pipe Pipe C10 90 o Elbow C11 45 o Elbow C20 Tee C60 Cap

GROOVED FITTINGS FOR COPPER TUBING

General Price List Main effective MAY 13, General Price List. Main

Fire Protection Price List. Piping. Systems. Solutions A FP.

SJ-300N J-04. Model SJ-300N-L Butterfly Valve with Lever Handle

Victaulic Standard Grooved and Advanced Grooved (AGS) Piping System for IPS Steel 2 (DN 50) through 60 (DN1500)

Vic -300 Butterfly Valves

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Series 756 FireLock Dry System Check Valve

I-731-D/W731-D. Suction Diffuser. Important Installation Information. series 731-D and W731-D

Series 758 FireLock Actuated System Valve

B U I L D I N G C O N N E C T I O N S T H AT L A S T

Series 751 FireLock European Alarm Check Valve Stations

Victaulic Specification Power Industry

Mechanical MATERIAL SPECIFICATIONS. Stainless Steel Housing Specifications. Gasket Specifications. Bolt / Nut Specifications

FIG Gruvlok Flanges

Fire Protection Price List

GRINNELL Model B303 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

VICTAULIC INSTALLATION-READY TECHNOLOGY UP TO 10 TIMES FASTER TO INSTALL THAN OTHER JOINING METHODS. Patented

The applicable material specifications for ductile iron and rubber gaskets apply:

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Advantages of Grooved Fittings


60.08 Style 233S Restrained Flexible Coupling For Dynamic Joint Deflection

70.03 Victaulic Vortex TM

Vic -300 Butterfly Valves

Grooved Piping System for Fire Protection Services

COOPLOK Grooved Submittal. Material Specifications

60.03 Style 231 Non-Restrained Flexible Expansion Coupling

Fire Protection Systems

FIRE PROTECTION EQUIPMENT 2017 DATA SHEETS BSP FIRE RESERVES THE RIGHT TO ALTER INFORMATION CONTAINED IN THIS CATALOGUE AT ANY TIME.

Grooved Piping System for Fire Protection Services

030/TL 03/01 50M, Copyright 2001, Anvil International $3. 50

Series 769 FireLock NXT Deluge Valve

FIRE SPRINKLER EQUIPMENT SUBMITTAL

INTRODUCTION. General Notes

Rubber Expansion Joints

I-234. Victaulic Styles 234/234S Restrained, Flexible Single-Gasket Couplings WARNING IMPORTANT INFORMATION ITEMS PROVIDED WITH SHIPMENT:

REPAMAX. Versatile Stainless Steel Coupling. Versatile Stainless Steel. By Krausz Wide-Range Couplings. Joins as a coupling. Repairs as a clamp.

Wide-Range Coupling Solutions

Mechanical Piping Products

Grinnell Grooved Fire Protection Products Grooved Fittings

Ductile Iron Pipe Fittings

Grooved Piping Products

SUBMITTAL PACKAGE FIRE PROTECTION VALVES

I-232.T3S2 Victaulic Style 232 Restrained, Flexible High-Pressure Coupling

Section 2. Shurjoint Grooved Fittings Flow Data / Friction Resistance Ductile Iron Grooved Fittings. Wrought Grooved Fittings

Hole-cutting. cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16mm) of the hole

60.07 Style 233 Restrained Flexible Coupling For Dynamic Joint Deflection

CLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION

HYMAX VERSA by Krausz Coupling and Repair Solutions

SCOPE OF WORK WASTEWATER TREATMENT PLANT THE WORLD LEADER IN PIPE JOINING SOLUTIONS

Introduction. We stay ahead of today s evolving market requirements by committing to a program of continued research and development.

Victaulic General Catalog. General Catalog g-103. g-103. Updated 6/2009

Victaulic Fittings, Couplings, Valves & Sprinkler Heads for the Fire Sprinkler Market Keeping the art of distribution simple

Section 1. Grooved Mechanical Couplings, Flange Adapters & Mechanical Tees

Typical Specifications Grooved Piping Method

Valves & Flow Control Components Valves & Flow Control Components

FIRE PROTECTION PRODUCTS

HYMAX GRIP by Krausz Restraint Solutions

Transcription:

SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Style 177 QuickVic flexible coupling is installation-ready, and joins 2-8"/50-200 standard roll grooved and cut grooved steel pipe. The coupling's unique design eliminates loose parts, ensures consistent installation and provides substantial gains in productivity. The Style 177 flexible coupling can accoodate pressures ranging from full vacuum (29.9 in Hg/760 Hg) up to 1000 psi/6900 kpa. The coupling's maximum pressure rating will depend on the diameter and wall thickness of the pipe. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference document 17.09 for pressure ratings and end loads. When used on light wall stainless steel pipe, the Victaulic R roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to document 24.01. * Sizes 2-4"/50-100 may be used to join 304/304L and 316/316L Schedule 10 stainless steel pipe from full vacuum (29.9 in Hg/760 Hg) to a maximum rated working pressure of 300 psi/2065 kpa. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Housing Coating: Orange enamel. Optional Coatings: Hot dipped galvanized Gasket: Grade EHP EHP (Red & Green stripe color code). Temperature range 30 F to +250 F/ 34 C to +121 C. Recoended for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services.* UL classified in accordance with ANSI/NSF 61 for cold +86 F/+30 C and hot +180 F/+82 C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade T nitrile Nitrile (Orange color code). Temperature range 20 F to +180 F/ 29 C to +82 C. Recoended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recoended for hot water services over +150 F/+66 C or for hot dry air over +140 F/+60 C. * Services listed are General Service Recoendations only. It should be noted that there are services for which these gaskets are not recoended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recoendations and for a l isting of services which are not recoended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Optional Bolts/Nuts: (Available in imperial size bolts and nuts only.) Bolts: Stainless steel, meeting the requirements of ASTM F-593, Group 2 (316 stainless steel), condition CW, with galling resistant coating. Nuts: ASTM F-594, Group 2 (316 stainless steel), condition CW JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date 1

DIMENSIONS PRE-ASSEMBLED (INSTALLATION-READ CONDITION) JOINT ASSEMBLED Nominal Size Size Actual Outside Diameter (1) Min Pipe End Sep. (2) Max (3) Max Bolt/Nut No. Size Pre-assembled (Installation-ready condition) Dimensions / Joint Assembled Aprx. Wgt. Ea. 2 2.375 0.13 0.19 0.25 3.87 5.59 3.56 5.39 2.05 2.0 50 60.3 4.8 6.4 2 ³ ₈ x 2½ 98 142 90 1.37 52 0.9 2½ 2.875 0.13 0.19 0.25 4.36 6.13 4.05 5.89 2.05 2.4 65 73.0 4.8 6.4 2 ³ ₈ x 2½ 111 156 103 150 52 1.1 76.1 3.000 0.13 0.19 0.25 4.40 6.31 4.09 6.28 2.02 2.5 2 M10 x 2½ 76.1 4.8 6.4 112 160 104 160 51 1.1 3 3.500 0.13 0.19 0.25 5.00 7.05 4.68 6.81 2.04 3.1 80 88.9 4.8 6.4 2 ½ x 3 127 179 119 173 52 1.4 4 4.500 0.13 0.25 0.38 5.98 8.24 5.61 7.92 2.15 3.7 100 114.3 6.4 9.5 2 ½ x 3 152 209 142 201 54 1.7 108.0 4.250 0.13 0.25 0.38 5.75 8.08 5.36 7.77 2.10 3.6 2 - M12 x 3 108.0 6.4 9.5 146 205 136 197 53 1.6 5 5.563 0.13 0.25 0.38 7.07 9.66 6.68 9.55 2.09 4.8 2 ½ x 3 125 141.3 3.3 6.4 9.7 180 245 170 243 53 2.2 133.0 5.250 0.13 0.25 0.38 6.76 9.35 6.525 9.26 2.09 4.8 2 - M12 x 3 133.0 6.4 9.5 172 237 166 235 53 2.2 139.7 5.500 0.13 0.25 0.38 7.01 9.52 6.71 9.42 2.14 4.9 2 M12 x 3 139.7 6.4 9.5 178 242 171 240 54 2.2 6 6.625 0.13 0.25 0.38 8.27 11.14 8.00 11.12 2.18 7.4 150 168.3 6.4 9.5 2 ⁵ ₈ x 4 210 283 203 282 55 3.4 159.0 6.250 0.13 0.25 0.38 7.89 10.92 7.87 10.80 2.17 7.1 2 - M16 x 3¼ 159.0 6.4 9.5 200 277 200 274 55 165.1 6.50 0.13 0.25 0.38 8.14 11.12 8.06 11.01 2.17 7.2 2 - M16 x 3¼ 165.1 6.4 9.5 207 282 205 280 55 3.3 8 8.625 0.19 0.31 0.44 10.48 13.56 10.09 13.42 2.56 10.5 200 219.1 4.8 7.9 11.2 2 ⁵ ₈ x 4 266 344 256 341 65 4.7 (1) The minimum pipe end separation as required by the gasket center leg for roll or cut grooved pipe. See illustrations below. (2 & 3) Maximum pipe end separation to be used for determining overall piping system movement for roll (2) or cut (3) groove pipe. For design and installation purposes, the minimum and maximum pipe end separations should be reduced to the values shown in the table below. These design and installation considerations include thermal growth, settlement, installation misalignment and offsets. See illustrations below. Lbs. kg Minimum Pipe Separation (1) Roll and Cut Groove Maximum Pipe Separation (2) Roll Groove Exaggerated for clarity Maximum Pipe Separation (3) Cut Groove _2

DESIGN AND INSTALLATION The amount of linear movement and angular deflection to be used for design and installation consideration for each coupling is shown in the table below. Design and Installation Values Size Range Roll Groove Pipe Cut Groove Pipe Angular Deflection Angular Deflection Pipe In/Ft Pipe In/Ft / Linear Movement # Per Cplg. Deg. /m Linear Movement # Per Cplg. Deg. /m 2 0.06 0.32 0.13 0.64 1.52 3.04 50 1.6 26 52 2½ 0.06 0.26 0.13 0.52 1.25 2.50 65 1.6 22 44 76.1 0.06 0.26 0.13 0.52 1.20 2.40 1.6 22 44 3 0.06 0.22 0.13 0.44 1.03 2.06 80 1.6 18 36 4 0.13 0.34 0.25 0.68 1.60 0 100 28 6.4 56 108.0 0.13 0.35 0.25 0.70 1.68 3.36 29 6.4 58 5 0.13 0.27 0.25 0.54 1.30 2.60 125 3.3 22 6.4 45 133.0 0.13 0.28 0.25 0.57 1.35 2.70 23 6.4 47 139.7 0.13 0.28 0.25 0.54 1.30 2.60 3.3 24 6.4 45 6 0.13 0.23 0.25 0.46 1.08 2.16 150 18 6.4 36 159.0 0.13 0.24 0.25 0.48 1.15 2.30 20 6.4 40 165.1 0.13 0.23 0.25 0.46 1.10 2.20 19 6.4 38 8 0.13 0.18 0.25 0.35 0.83 1.66 200 3.3 15 6.4 29 Victaulic recoends for design and installation purposes, these values should be reduced by 50% for ¾-3 ½"/20-90 sizes; 25% for 4"/100 and larger sizes. _3

PERFORMANCE ANSI STANDARD Nominal Actual Size Schedule 10 (Steel Pipe) Schedule 40 (Steel Pipe) Actual Max. *ŧ Max. * Max. * Outside Wall Joint Permis. Wall Joint Diameter Thick. Work. End Thick. Work. Press. Load Press. psi/kpa Lbs./N psi/kpa Max. * Permis. End Load Lbs./N 2 2.375 0.109 750 3322 0.154 1000 4430 50 60.3 2.77 5170 14780 3.91 6900 19706 2½ 2.875 0.120 600 3895 0.230 1000 6492 60 73.0 3.05 4135 17326 5.84 6900 28877 3 3.500 0.120 600 5773 0.216 1000 9621 80 88.9 3.05 4135 25678 5.49 6900 42797 4 4.500 0.120 600 9543 0.237 1000 15904 100 114.3 3.05 4135 42448 6.02 6900 70746 5 5.563 0.134 500 12153 0.258 750 18229 125 141.3 3.40 3445 54059 6.55 5170 81088 6 6.625 0.134 450 15512 0.28 700 24130 150 168.3 3.40 3102 69000 7.11 4825 107336 8 8.625 0.148 300 17528 0.322 600 35056 200 219.1 3.76 2065 77968 8.18 4135 155936 WARNING: Depressurize and drain the piping system before attempting to install, remove or adjust any Victaulic piping products. * Working Pressure and End Load are total, from all internal and external loads, based on (ANSI) steel pipe, grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONL, the Maximum Joint Working Pressure may be increased to 1½ times the figures shown. ŧ culus approved for use on schedule 10 pipe: 2, 2 ½, 3 and 4 inch sizes rated to 363 psi/25 bar; 5 inch rated to 290 psi/20 bar; 6 and 8 inch rated to 232 psi/16 bar. FM approved on schedule 10 pipe: 2, 2 ½, 76.1, 3, 4, 139.7, 5, 6 and 8 inch sizes rated to 363 psi/25 bar. culus approved for use on schedule 40 pipe: 2, 2 ½, 3, 4, 5, 6 and 8 inch sizes rated to 363 psi/25 bar. FM approved for use on schedule 10 and 40 pipe: 2, 2 ½, 76.1, 3, 4, 139.7, 5, 6 and 8 inch sizes rated to 363 psi/25 bar. _4

PERFORMANCE DIN STANDARD Nominal Size Normal Din Wall Pipe Other DIN Wall Pipe Actual Max. *ŧ Max. * Max. * Outside Wall Joint Permis. Wall Joint Diameter Thick. Work. End Thick. Work. Press. Load Press. psi/kpa Lbs./N psi/kpa Max. * Permis. End Load Lbs./N 2 2.375 0.091 750 3320 0.157 1000 4430 50 60.3 2.3 5170 14780 4.0 6900 19706 76.1 ŧ 3.000 0.150 600 4240 0.200 1000 7070 76.1 3.8 4135 18870 5.1 6900 31460 3 3.500 0.114 600 5773 0.197 1000 9621 80 88.9 2.9 4135 25678 5.0 6900 42797 4 4.500 0.126 600 9543 0.220 1000 15904 100 114.3 4135 42448 5.6 6900 70746 108.0 4.250 0.114 600 8512 0.220 1000 14186 108.0 2.9 4135 37862 5.6 6900 63104 133.0 5.250 0.126 500 10824 0.248 750 16236 133.0 3445 48147 6.3 5170 72220 139.7 ŧ 5.500 0.150 500 11879 0.200 750 17819 139.7 3.8 3445 52840 5.1 5170 79262 6 6.625 0.157 450 15512 0.280 700 24130 150 168.3 4.0 3102 69000 7.1 4825 107336 159.0 6.250 0.126 500 15340 0.28 700 21476 159.0 3445 68235 7.1 4825 95529 165.1 6.50 0.177 450 14932 0.280 700 23228 165.1 4.5 3102 66423 7.1 4825 103324 8 8.625 0.177 300 17528 0.315 600 35056 200 219.1 4.5 2065 77968 8.0 4135 155936 WARNING: Depressurize and drain the piping system before attempting to install, remove or adjust any Victaulic piping products. * Working Pressure and End Load are total, from all internal and external loads, based on (ANSI) steel pipe, grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONL, the Maximum Joint Working Pressure may be increased to 1½ times the figures shown. ŧ culus approved for use on DIN wall pipe (2.9 thickness) 76.1 rated to 363 psi/25 bar; (4.0 thickness) 139.7 rated to 290 psi/20 bar; (4.5 thickness) 165.1 rated to 290 psi/20 bar. FM approved on schedule 10 and 40 pipe: 2, 2 ½, 76.1, 3, 4, 108.0, 133.0, 139.7, 5, 159.0, 165.1, 6 and 8 inch sizes rated to 363 psi/25 bar. _5

GENERAL NOTES NOTE: When assembling Style 177 QuickVic flexible couplings onto end caps, take additional care to make certain the end cap is fully seat against the gasket center leg. For Style 177 QuickVic flexible couplings, use Victaulic No. 60 end caps containing "QV" or "QV/E" markings on the inside of the face. Non-Victaulic fittings shall not be used with Style 177 QuickVic flexible couplings. INSTALLATION Reference should always be made to the I-177 Victaulic Field Installation Instructions for the product you are installing. Instructions are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at. WARRANT Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit 5147 REV L UPDATED 01/2013