MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

Similar documents
MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIVERT 250A Size 1, 690VAC

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIVERT 1000A Main Incomer, 690VAC

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC

INNOZED D0 fuse-bases with touch protection

LINOCUR Size D02 63A 230VAC/440VAC

INNOZED D0 fuse-bases with touch protection

Modulostar CMS10 Modular fuse-holders

UltraSafe US22 Modular fuse-holders

Modulostar US10 Modular fuse-holders

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

Fuse switch disconnectors

BETA Switching Switches and Light Indicators

NEOZED D0 fuse-links gg 400/440VAC

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

vertical fuse switch disconnectors

3NP1 Fuse Switch Disconnectors up to 630 A

Fuse switch-disconnectors

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

MULTIFIX 60 Universal Bus Bar Carriers

Fuse switch-disconnectors

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

IEC Low Voltage General Purpose Protection

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links am 690VAC top indicator/live tags size 4, 4a


CATALOG. EasyLine XLP Fuse Switch Disconnector poles

Special Purpose Fuses

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

Varius SUMMARY OF MODELS

Fuse switch disconnectors

Varius SUMMARY OF MODELS

Horizontal fuse disconnects

Varius SUMMARY OF MODELS

LV HRC fuse switch-disconnectors

185mm-System power 2500A. Expertise

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Vertical fuse disconnects

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

MOULDED CASE CIRCUIT BREAKERS BC160N

FUSE BASES NH FUSE BASES 690V 160A 160A

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Control Circuit Protection

Cylindrical fuse-link

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

CENTRE FEED UNIT UP TO 4000A. Safety

SENTRON Switching and Protection Devices Switch Disconnectors

Limitor -G General Purpose Fuses

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Synergy EN product information

MC FRAME SIZE 1 / UP TO 160A

FL series position switches

NH Plastic bases. NH Plastic bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards

Thermal overload relay TF65 and TF96

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

PANEL PANEL MOUNTING COMPONENTS

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Vertical fuse disconnects

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

AF40... AF96 3-pole contactors Technical data

CRITO Connection technology. Double and triple T and TCC section busbars

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Vertical fuse disconnects

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

max pole for t=15 ms

Motorized switch-disconnectors OTM 40 to 125 Amperes

PROTECTION AND CONNECTION. ABB Compact ATS Compact without compromise

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

NH-Fuse system Low voltage

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Breakers and Switches. Switches Switch-disconnectors OT and OTM

Short form catalogue. Motor protection & control

MS General Information Extended Product Type: MS

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

SFS-UFS Single Foot Switches

Position switches FD series

Transcription:

MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple pole units for direct installation on to 40 mm and 60 mm bus bar systems. For installation of MULTIBLOC NH fuse switch disconnectors of different sizes in distribution units with central cover, respective covers are used to obtain a uniform profile in height and length. MULTIBLOC size 2 are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 2: 400A. The system is a modular system, which allows the installation and combination of individual components. MULTIBLOC offers the user the possibility of fast and easy installation as well as a high degree of security during installation and maintenance. TECHNICAL DATA OVERVIEW Voltage AC 690 VAC Voltage DC 440 VDC Amper (A) 400 A Size per Standard 2 Ue = AC 400 V; Ie = 400 A SCCR Ue = AC 500 V; Ie = 400 A Ue = AC 690 V; Ie = 315 A Mounting bus bar installation Switchability triple pole switching 80kA 80kA 80kA FEATURES & BENEFITS Touch protection IP 20 (IP rating maintained if fuse-link in test mode) Parking position of switch operating cover even with fuse-links inserted Direct installation on to bus bar (snap on) Switch still adjustable after being snapped on to busbars and fixed after adjustment Universally useable for bus bars with thickness of 5-10mm and widths of 12 30mm Symmetrical switch: suitable for bottom/top cable terminal connections Cable termination: screw, bolt, clamp strap, extendable for V-terminal - optional Electronic or electro-mechanic fuse monitoring - optional Cover for touch protection for direct installation on to busbar systems - optional Safe on load connection/disconnection: accordance with IEC 60947-3 APPLICATIONS Panel boards for industrial use Feeder pillars for industrial use Meter distribution units Measuring transformer cabinets Transmitting stations for telecommunications STANDARDS IEC/EN 60 947-3 For NH fuse-links size 2 in accordance with IEC/EN 60269-2, VDE 0636-2 EP.MERSEN.COM 1

PRODUCT RANGE MULTIBLOC 2.RST8 size 2 400A, 690VAC bus bar installation, triple pole Catalog Reference Poles Cable termination components Design Weight kg 1 Package 1.000.704 1.000.704 M1002167 3 3 M10 terminal screws - 4.77 1 piece 1.001.295 C1023065 3 3 clamp straps 120 240 mm² - 4.61 1 piece 1.003.135 D1023066 3 3 M10 terminal screws with electronic fuse monitoring ESÜ installed (rated voltage = 525VAC) 4.60 1 piece 1.000.856 Z1023062 3 3 M10 terminal screws with electro-mechanic fuse monitoring MZS installed (galvanic isolation) 5.28 1 piece 1.001.028 A1023063 3 6 M10 terminal screws main incomer 5.74 1 piece 1 weight in kg per piece or set including package 1.003.135 1.000.856 EP.MERSEN.COM 2

TECHNICAL DATA IN ACCORDANCE WITH EN / IEC 60947 2.RST8 triple pole Number of poles/phases 3 Size 2 Conventional free air thermal current with NH-fuse links I th 400 A Max. power dissipation of fuse links P n 34 W Conventional free air thermal current with solid links I th 530 A Max. power dissipation of solid links P n 9 W Utilization category to IEC/EN 60947-3 U e = AC 400 V; I e = 400 A U e = AC 500 V; I e = 400 A U e = AC 690 V; I e = 315 A U e = DC 440 V; I e = 400 A Rated operational voltage U e Rated insulation voltage U i Rated impulse withstand voltage U imp Rated frequency AC 23 B AC 22 B AC 21 B DC 21 B 690 V 1000 V 12 kv 50... 60 Hz Degree of protection IP 20 Degree of pollution 3 Rated duty uninterrupted duty Rated conditional short-circuit current with fuse links U e = AC 400 V; I e = 400 A U e = AC 500 V; I e = 400 A U e = AC 690 V; I e = 315 A Rated short circuit making capacity with solid links I cm Rated short-time withstand current I cw Power dissipation by I th without NH-fuse links Installation mode 80 ka 80 ka 80 ka 10.6 kasw 13 ka / 1 s 60 W bus bar installation Cable terminal connection Standard cable terminal for cable lugs Cu max. for cable lugs Al max. for copper bars with max. dimensions Bus bar terminal connection Bus bar width (bus bar system = 40 mm) Bus bar thickness (bus bar system = 40 mm) Bus bar width (bus bar system = 60 mm) Bus bar thickness (bus bar system = 60 mm) Bus bar system M10 2 x 185 mm² 2 x 240 mm² 35 x 10 mm 12 mm 5... 10 mm 12... 30 mm 5... 10 mm 40 mm 60 mm EP.MERSEN.COM 3

DIMENSIONS MULTIBLOC 2.RST8 NH-fuse switch disconnector triple pole design for bus bar installation (M01132a) 5 mm with distance piece cut out for central cover Dimensions in mm EP.MERSEN.COM 4

DIMENSIONS MULTIBLOC main incomer size 2 (M01167-2) 204, 5 22 55, 5 157 60 60 391, 5 11 4 134 196 max: 30 x10 195, 5 bus bar system: max. 60 x 10 tightening torque: cable terminal M10: 20 Nm bus bar terminal: hexagon screw: M10: 15 Nm 50, 5 106 Dimensions in mm fig.1 fig.3 IN 2xI N incoming current IN 1xI N incoming current fig.2 IN 2xI N incoming current EP.MERSEN.COM 5

DIMENSIONS MULTIBLOC 2.ST8 and 2.RST8 triple pole with electronic fuse monitoring ESÜ (M01174-2) 80 149 306 158 52 90 50 204,5 105 174 331 Dimensions in mm 52 90 EP.MERSEN.COM 6

DIMENSIONS MULTIBLOC 2.ST8 and 2.RST8 triple pole with electro-mechanic fuse monitoring MZS (M01135-2) 203,5 233 Dimensions in mm EP.MERSEN.COM 7

DIMENSIONS MULTIBLOC bus bar adapter with clamp terminal for 2.ST8 (M01151a-2) 204,5 32 157 100 98,5 268 70 mm 90 mm 143 100 m 182 106 Dimensions in mm m= max. 6 0x1 0 tightening torque: M10: 25 Nm M8: 15 Nm 72 106 EP.MERSEN.COM 8

DIMENSIONS Cable termination size 2 (MA 98e-2) screw terminal: (standard) M10x20 screw tightening torque 20Nm M10 nut tightening torque 20Nm bolt terminal: (standard) size.2: M8x35 screw tightening torque 8Nm terminal: clamp strap (option/accessory) spring washer M10 M10 spring washer spring ring clamp strap cable lug or copper bar washer M10x30 screw tightening torque 20Nm screw and bolt terminal for size. 2: DIN 46234 max. 240mm² DIN 46235 max. 185mm² DIN 46329 max. 240mm² Dimensions in mm 10 copper bars: 11 20 35 size. 2: for round stranded conductors 120 x 240 for bars or laminated copper 21 x 3-14 EP.MERSEN.COM 9

EXPLODED SKETCH MULTIBLOC 2.RST8 NH-fuse switch disconnector triple pole design for bus bar installation (E 1.000.605) 2 2 4 2 5 1 no. article short Description 1 1.000.861 Cover for cable termination,set = 2 pcs. 2 1.000.150 Locking device f. windows,1 Set=3 pieces 3 1.000.863 Cover shield 230 x 300 mm 4 1.000.852 indicator for switch door position 5 1.003.347 bus bar touch protection 3 EP.MERSEN.COM 10

ACCESSORIES Cover shields Catalog Reference Design Weight Package 1.000.863 V1002174 cover shield for installation in distribution units size (width x height): 230 x 300 mm for one 2.ST8/2.RST8 triple pole 0.102 kg 1 piece 1.000.863 1.002.352 1.002.352 Y1022969 cover shield for installation in distribution units size (width x height): 234 x 310 mm for one 2.ST8/2.RST8 triple pole 0.11 kg 1 piece Cover/shrouds for cable termination Catalog Reference Design Weight Package 1.000.861 N1002168 cover for cable terminal connection for 2.ST8 triple pole, 1 set = 2 pieces 0.308 kg 1 set 1.003.347 H1023116 bus bar touch protection for 2.RST8 97 g 1 piece 1.000.861 1.003.347 1.000.852 1.000.150 Indication facilities Catalog 1.000.852 Q1002285 Locking and sealing devices/locking device for window Catalog 1.000.150 K229296 Reference Design Weight Package indicator for switch door position micro switch, 1 change-over contact 5 A, 250 V Reference Design Weight Package locking device for window for 00.ST8 1-, 2-, 4-pole and 1./2.ST8/RST8 1 set = 3 pieces 0.09 kg 1 piece 20 g 1 set EP.MERSEN.COM 11

ACCESSORIES Varieties of cable termination Catalog Reference Design Weight Package 1.001.237 1.001.237 B1002180 13SZAV6 K1023118 13SZAD6 A1022971 clamp strap size 2 120 240 mm², 1 set = 3 pieces V-terminal size 1,2,3; M12, for V-terminal clamps size 1,2,3 for MULTIBLOC size 2 supplementary set for V-terminal with use of V-clamps 1 set = 3 pieces M12 terminal lugs for M12 double terminal for MULTIBLOC size 2 and 3 1 set = 3 pieces 0.261 kg 1 set 0.27 kg 1 set 0.259 kg 1 set 13SZAV6 13SZAD6 EP.MERSEN.COM 12