Cool with the sun and save 60% of your power

Similar documents
40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw

Multizone Multi Split systems

FULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

VRF. For Commercial and Light Commercial

Ductless. MRV-S (Mini VRF) Product Brochure. Higher Comfort, Haier Living. rev 01/01/2018

Ducted medium static pressure monosplit DC Inverter

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Enhanced Air Conditioning

Ductless Split Systems

Engineering Data Book

DLC4AV09J1A DLC4AV18K1B DLC4HV09J1A DLC4HV12J1A 1 DLC4HV12K1A 1 DLC4HV18K1A DLC4HV30K1A

R4H4. Product Specifications

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

Ductless Split Systems

COMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS

Unique solutions FLEXY MATCH FLEXY MATCH FLEXY MATCH R410A FLUID AUTO AUTO CLEAN/DRY SLEEP MODE LOW BATTERY INDICATION WIRED CONTROL OPTION

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h

Models: 12 and 18. Models: 24 to 60

Ductless Split Systems

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

P7RF Series Two-Stage, Single Phase Packaged Air Conditioner

2010 Duct-Free Splits Line Card

YCZ HIGH WALL RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

PRODUCT LINEUP MULTI SPLIT

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

AIR CONDITIONERS WA16 SERIES

Bosch BOVA Split System Heat Pump

HIGH-EFFICIENCY MINI-SPLIT AIR CONDITIONERS AND HEAT PUMPS

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

PRPAC14 PRODUCT SPECIFICATIONS 14 SEER ELECTRIC/ELECTRIC PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER INSTALLATION WARRANTY

P7RE Series Single Packaged Air Conditioner

Air conditioning. Residential and Light Commercial

P7RE Series Single Packaged Air Conditioner

PRAC14 PRODUCT SPECIFICATIONS

N4A6. Product Specifications

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

TECHNICAL SPECIFICATIONS

Y-Flow TCHEY-THHEY

H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

WCA4**4. Product Specifications

6,3 108 kw R410A UP FLOW DOWN FLOW !"#$% "&'("!%)*(% "&+*'*"&$(#%,*'-%($."'$%)*(% ""!$+% "&+$&#$(%"(%/0*!'1*&%,)'$(% ""!$+% "&+$&#$( RCGROUP SpA

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

HCH6. Product Specifications

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

DC INVERTER DUCTED AIR CONDITIONERS

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A

New ECOi Electric 2 and 3 pipe VRF systems. 2006/7 Range. All round air conditioning by

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h

PREMIUM INVERTER DUCTED AIR CONDITIONING

COMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

Bosch BOVA Split System Heat Pump

Air-conditioning. split ducted systems

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H

SOLAR AIR CONDITIONER

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

DC INVERTER VRF SYSTEMS C-VRF

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

INVERTER MULTI SYSTEMS 38QUS*-1

VHIA High-Static Ducted Indoor Units - 60HZ

INVERTER DUCTED SYSTEMS

PRICE LIST

AHN 064 to 304 EHN/CHN 064 to 304

Air Conditioning Selection Guide

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

4SHP18LS PRODUCT SPECIFICATIONS

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B American Standard Inc. All Rights Reserved

Ductless Split Systems

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER

GSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons

C4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

AVXC20. High-Efficiency, Comfortnet-Compatible, Variable-Speed, Inverter Drive Split System Air Conditioner. Cooling Capacity : 23,600 53,000 BTU/h

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

PHR5. Product Specifications

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

Hi-Wall Inverter Split System. Cooling and heating, exactly where and when you need it

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

CSA6. Product Specifications. SoftSound SXC 2600

LG HVAC SOLUTION. LG Electronics. Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Transcription:

Cool with the sun and save 60% of your power Saves up to 60% of your electrical power Same prices as non solar systems (incl. panel!) Top technology with attractive indoor units Heat pump for cooling and heating Thousands of installations worldwide

How SolarCool TM works Sedna Aire relies on the well known compression cycle technology for cooling and incorporates a high efficient solar panel into it. While in standard units the compressor has to do the full compression load, at SolarCool TM the solar panel is taking over much of the compression load and thus frees a lot of energy. The secret behind SolarCool TM is the Ideal Gas Law, saying that gases may be compressed also by heat. Everybody who has pumped up his bicycle has realized this as the pump got hot. SolarCool TM is reversing this principle in compressing the refrigerant by heat provided free by the sun. The hotter the sun, the better it works! And more power is saved! The remaining cooling circle stays the same: After compression the refrigerant is cooled down in the condenser, expanded in a nozzle and then evaporated. By evaporating the refrigerant the environment is cooled down: It Cools. Most SolarCool TM systems from Sedna Aire are available as heat pumps. Due to a small modification the units may not only cool, but also heat with the help of the sun. This again saves power also for heating! Solar Panel Condenser Expansion valve Evaporator Starting Temp. Conventional Type DC Inverter Type Compressor Target Temp. The DC Inverter Technology widely used for the compressors is also state of the art for our split systems. The alternating current (AC) from the grid is converted into direct current (DC) and then back to AC but this time with variable frequencies. And it s these variable frequencies which control the compressor. As a result the compressor runs more precisely and requires less power than a conventional On/Off system. Solar assisted air conditioners working this principle are exclusively manufactured by Sedna Aire, since we invented the system and hold all the patents. This ensures the necessary quality and reliability for your comfort and benefit. Reliability and references Our systems are highly reliable and we look over thousands of successful installations. We use only standard components from well known and reputable companies assuring the required quality. The refrigerant s high temperature of up to 100 C poses no threat, since it is widely used for solar water heaters. The refrigerant itself is R410, non explosive and harmless. Some successful residential and commercial installations are shown below: 01001020101 Sedna Aire Europe GmbH 2 2014

Savings Only one solar panel fits most applications. The hotter the sun, the better it works and you will save more power. The sun is taking over more and more the job from the compressor. Units Single Split Multi Split Mini VRF VRF 12SP 24SP 028B 042B 140 400 Cooling capacity 3,5 kw 6,5 kw 8 kw 11,6 kw 14 kw 40 kw Number of indoor units 1 1 4 5 8 23 Non solar system Power consumption 1,3 kw 2,3 kw 2,5 kw 3,5 kw 4,0 kw 11,3 kw SolarCoolTM system Sedna 1 Aire Power consumption 0,5 kw 0,9 kw 1,0 kw 1,4 kw 1,7 kw 5,5 kw Difference in Power consumption SolarCool to non solar system 62 % 61% 60% 60% 57% 51% Annual Cost saving SolarCool TM 2 systems 96 168 180 252 1 380 3 480 1 2 measured at SolarCool systems 2011 2013. For verification see www.sednaaireeurope.com acc. to EU guideline CE 2002/31 for 500h cooling per year and 0,24 /kwh, VRF commercial systems at 2500 hours (8 hours 6 days per week Calculate your personal energy savings with our energy calculator at our website. The SolarCool TM systems will also work at lower sun radiation, e.g. during a cloudy day, since we use high efficient vacuum tube collectors. With SolarCoolTM systems you will be leading edge technology and save a significant amount of power for many years. And best of all: They come at the same costs as comparable non solar air conditioners INCLUDING the panel! Our models We offer the full range for your application Single Split Units (2,6 7kW) One outdoor unit and one separate indoor unit for conditioning one room Mini VRF Units (8 27kW) One outdoor unit and up to 12 separate indoor units for conditioning multiple rooms Multi Split Units (5 12kW) One outdoor unit and up to 5 separate indoor units for conditioning multiple rooms VRF Units (25 45kW and higher) One outdoor unit and up to 26 separate indoor units per module for conditioning multiple rooms 01001020101 Sedna Aire Europe GmbH 3 2014

Single Split units Outdoor/Indoor Unit SWM 09 EU 12 EU 18 EU 24 EU Cooling capacity (a) kw 2,8 3,1 5,0 6,5 Heating capacity (a) kw 2,6 3,2 4,9 6,5 Energy efficiency SEER (Cool) W/W 7,5 7,7 8,3 8,3 Energy efficiency class (Cool) A++ A++ A++ A++ Power consumption min max (Cool) kw 0,1 0,8 0,1 0,9 0,1 1,4 0,1 1,8 Operating temperature range ( Cool ) C 15/50 15/50 15/50 15/50 Energy efficiency SCOP (Heat) W/W 5,5 5,3 5,2 5,1 Energy efficiency class (Heati A+++ A+++ A+++ A+++ Power consumption min max (Heat ) kw 0,1 0,7 0,1 1,1 0,2 1,3 0,2 1,8 Operating temperature range ( Heat ) C 15/30 15/30 15/30 15/30 Air flow indoor m³/h 440 620 430 630 400 730 900 1150 Dehumidification (only when cooling) l/h 1,0 1,1 1,7 2,4 Sound level indoor (b) db(a) 31 41 31 41 31 41 41 49 Sound level outdoor (b) db(a) 56 56 59 60 Active Carbon Filter Indoor Yes Yes Yes Yes Plasma Ionization Yes Yes Yes Yes Remote Control Indoor 24h Timer Yes Yes Yes Yes Indoor fan speeds 3 3 3 3 Automatic Louver adjustment Yes Yes Yes Yes Turbo Fan Modus Yes Yes Yes Yes Power supply (Volt/Phases/Freq.) 230/1/50 230/1/50 230/1/50 230/1/50 Breaker fuse (time delay) A 16A 16A 16A 16A Number of required solar panels Pc 1 1 1 1 Indoor unit dimensions (HxWxD) mm 800x188x275 800x188x275 940x205x275 1045x235x315 Indoor unit weight Kg 7 7 9 12 Outdoor unit dimensions (HxWxD) mm 780x250x540 780x250x540 760x285x590 845x320x700 Outdoor unit weight kg 30 30 35 48 Solar panels needed 1 1 1 1 (size 120x1610x1610 mm) Solar panel weight kg 61 61 61 61 Inclination solar panel (c) 20 50 20 50 20 50 20 50 Refrigerant type R410A R410A R410A R410A Compressor DC Inverter DC Inverter DC Inverter DC Inverter Diameter Gas line inch 3/8 3/8 1/2 5/8 Diameter Liquid line Inch 1/4 1/4 1/4 3/8 Diameter piping to solar panel (d) Inch 1/2 1/2 1/2 1/2 Max. pipe length to solar panel (d) m 18 18 18 18 Max. lift to solar panel m 8 8 8 8 Max. pipe length to ind. unit (total) m 15 20 25 25 Max. lift to indoor unit m 7 8 15 15 Warranty Years 2 2 2 2 All Single Split units (indoor and outdoor units) CE certified. According to EU guideline 626/2011 these units are local air conditioners (a) All figures given for SolarCool mode with solar panel following ISO 5151 and EU guideline 626/2011. Actual energy consumption and number of required panels may vary and will depend on how the appliance is used and where it is located (b) For details see technical specification (c) Sound level, measured at a distance of 1m under free field conditions (d) To be optimized for your latitude (e) At a piping diameter of at least 1/2, recommended ø15mm At installation all national and local building and safety codes are to be complied to Heat pump: cools AND heats in one model due to some minor modifications in the cooling circle. A standard air conditioner is only able to cool 01001020101 Sedna Aire Europe GmbH 4 2014

Multi Split Units Outdoor unit CMO 018B 024B 028B 036B 042B Cooling capacity (a) kw 5,0 7,0 8,0 9,8 11,6 Heating capacity (a) kw 5,6 7,7 9,3 11,0 13,0 Number of indoor units 1 2 1 2 2 4 2 4 2 5 Cooling capacity min max (Cool) kw 2,1 6,2 2,7 8,2 2,2 10,0 3,0 11,0 3,5 13,6 Energy efficiency SEER (Cool) W/W 7,8 7,8 8,1 6,8 6,8 Energy efficiency class (Cool) A++ A++ A++ A++ A++ Power consumption min max (Cool) kw 0,1 1,4 0,1 1,8 0,2 2,2 0,3 3,1 0,3 3,6 Heating capacity min max (Heat) kw 2,5 6,7 3,5 9,5 2,8 11 4,5 12 4,5 14 Energy efficiency SCOP (Heating) W/W 5,3 5,3 5,3 5,3 5,2 Energy efficiency class (Heating) A+++ A+++ A+++ A+++ A+++ Power consumption min max (Heat ) kw 0,2 1,7 0,3 2,1 0,4 2,3 0,4 2,9 0,5 3,4 Sound level outdoor Max. /Min. db(a) 56/50 58/52 59/53 54/51 58/52 Power supply (Volt/Phases/Freq.) 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Breaker fuse (time delay) A 16A 25A 25A 32A 32A Number of required solar panels Pc 1 1 1 1 1 Operating temp.range (Cool) C 15 / 43 15 / 43 15 / 43 15 / 43 15 / 43 Operating temp.range (Heat) C 18 / 24 18 / 24 18 / 24 18 / 24 18 / 24 Outdoor unit dimensions (HxWxD) mm 596x818x378 700x890x396 700x890x396 950x840x412 1015x1103x440 Outdoor unit weight kg 43 59 60 73 102 Solar panel dimensions (HxWxD) mm 1.618 x 1.638 x 130 Solar panel weight kg 61 Recommended inclination panel 20 50 Refrigerant type R410A R410A R410A R410A R410A Refrigerant charge Kg 1,35 2,4 2,2 3,6 4,2 Compressor DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter Max. pipe length to solar panel m 18 18 18 18 18 Max. lift to solar panel m 8 8 8 8 8 Max. pipe length to indoor unit (total) m 25 25 70 70 80 Max. lift to indoor unit m 10 10 15 15 15 Indoor units Indoor units CMI09 CMI12 CMI18 CMC12 E CMC18 E CMC24 N Cooling capacity kw 2,6 3,5 5,3 3,5 4,5 7,1 Heating capacity kw 2,8 3,8 5,8 4,0 5,0 8,0 Type Wall C Wall C Wall C Cass E Cass E Cass N Air flow indoor m³/h 450 550 840 600 600 1 180 Sound Level (high low) db(a) 35/28 35 / 28 43 / 32 46 / 40 46 / 40 39 / 33 Active Carbon Filter Indoor Yes Yes Yes Yes Yes Yes Remote Control with 24h Timer Yes Yes Yes Yes Yes Yes Indoor fan speeds 3 3 3 3 3 3 Automatic Louver adjustment Yes Yes Yes Yes Yes Yes Turbo Fan Modus Yes Yes Yes Yes Yes Yes Dimensions (HxWxD) mm 815x165x267 872x178x283 960x195x300 570x570x230 570x570x230 840x840x240 Weight kg 10 11 13 20 20 26 2 All Multi Split units (Indoor and Outdoor) are CE certified. According to EU guideline 626/2011 these units are local air conditioners (a) Same conditions as for single splits apply 01001020101 Sedna Aire Europe GmbH 5 2014

Mini VRF Units Outdoor Outdoor unit Mini VRF 1 SVRF 80 SVRF 100 SVRF 120 SVRF 140 Cooling capacity (a) kw 7,2 9,0 12,3 14,0 Heating capacity (a) kw 7,2 9,0 13,2 15,4 Number of indoor units 4 5 6 7 Seasonal Energy eff. SEER/class (cool) W/W 7,1/A++ 7,1/A++ 7,2/A++ 7,1/A+ Power consumption min max (cool) kw 0,2 1,9 0,2 2,4 0,3 3,2 0,4 3,6 Seasonal Energy eff. SCOP/class (heat) W/W 5,1/A+++ 5,0/A+++ 4,9/A++ 4,6/A+ Power consumption min max (heat) kw 0,2 2,3 0,2 2,8 0,3 4,4 0,4 5,3 Sound level outdoor db(a) 56 57 57 57 Power supply (Volt/Phases/Freq.) 220/50/1 220/50/1 380/50/3 380/50/3 Number of required solar panels Pc 1 1 1 1 Operating temp. range (Cooling) C 15 / 48 15 / 48 15 / 48 15 / 48 Operating temp. range (Heating) C 15 / 27 15 / 27 15 / 27 15 / 27 Outdoor unit dimensions (HxWxD) mm 990x966x336 990x966x336 900x1327x320 900x1327x320 Outdoor unit weight kg 62 74 95 95 Refrigerant R410 charge Kg 2,8 3,0 3,3 3,9 Compressor Rotary Rotary Rotary Rotary Max. pipe length lift to solar panel m 18 8 18 8 18 8 18 8 Total piping length m 100 100 100 100 Max. pipe length lift to indoor unit m 30 8 30 8 30 8 30 8 Warranty Years 2 2 2 2 Outdoor unit Mini VRF 2 SVRF 155 SVRF 200 SVRF 220 SVRF 270 Cooling capacity (a) kw 15,5 19,5 22,4 26,0 Heating capacity (a) kw 17,0 23,0 24,5 28,5 Number of indoor units 8 10 11 12 Seasonal Energy eff. SEER/class (cool) W/W 7,0/A++ 6,9/A++ 6,9/A++ 6,8/A++ Power consumption min max (cool) kw 0,5 4,6 0,5 5,9 0,5 6,6 0,6 7,5 Seasonal Energy eff. SCOP/class (heat) W/W 4,6/A++ 4,6/A++ 4,5/A+ 4,5/A+ Power consumption min max (heat) kw 0,4 6,2 0,5 8,1 0,6 8,9 0,7 10,9 Sound level outdoor db(a) 57 59 59 59 Power supply (Volt/Phases/Freq.) 380/50/3 380/50/3 380/50/3 380/50/3 Number of required solar panels Pc 1 1 2 (b) 1 1 Operating temp. range (Cooling) C 15 / 48 15 / 48 15 / 48 15 / 48 Operating temp. range (Heating) C 15 / 27 15 / 27 15 / 27 15 / 27 Outdoor unit dimensions (HxWxD) mm 900x1327x320 1120x1560x415 1120x1560x415 1120x1560x415 Outdoor unit weight kg 107 137 147 147 Refrigerant R410 charge Kg 3,9 4,8 6,2 6,2 Compressor Rotary Rotary Rotary Rotary Max. pipe length lift to solar panel m 18 8 18 8 18 8 18 8 Total piping length m 100 120 120 120 Max. pipe length lift to indoor unit m 30 8 30 8 30 8 30 8 Warranty Years 2 2 2 2 All Mini VRF units (Indoor and Outdoor) are CE certified. According to EU guideline 626/2011 these units are local air conditioners (a) Same conditions as for single splits apply 01001020101 Sedna Aire Europe GmbH 6 2014

VRF Units Outdoor May be combined to up to 6 modules for higher capacity Outdoor unit VRF SVRF 252 SVRF 280 SVRF 340 SVRF 400 SVRF 450 Cooling capacity (a) kw 25,2 27,5 32 39 45 Heating capacity (a) kw 27 31,5 37,5 45 50 Number of indoor units 13 16 20 23 26 Seasonal Energy eff. SEER/class (cool) W/W 8,6/A+++ 8,4/A+++ 8,2/A+++ 8,0/A++ 7,9/A++ Power consumption min max (cool) kw 0,5 5,8 0,5 6,9 0,7 8,3 0,9 11,0 1 13,0 Seasonal Energy eff. SCOP/class (heat) W/W 5,4/A+++ 5,1/A++ 5,1/A++ 4,9/A++ 4,7/A++ Power consumption min max (heat) kw 0,5 8,4 0,6 9,4 0,7 11,7 0,9 14,7 1 16,9 Sound level outdoor db(a) 57 57 59 61 61 Power supply (Volt/Phases/Freq.) 380/50/3 380/50/3 380/50/3 380/50/3 380/50/3 Number of required solar panels (b) Pc 1 2 1 2 2 4 2 4 2 4 Operating temp. range (cool) C 15 / 48 15 / 48 15 / 48 15 / 48 15 / 48 Operating temp. range (heat) C 15 / 27 15 / 27 15 / 27 15 / 27 15 / 27 Outdoor unit dimensions (HxWxD) mm 960x1615x765 960x1615x765 1250x1615x765 1250x1615x765 1250x1615x765 Outdoor unit weight kg 198 198 288 288 288 Refrigerant R410 charge Kg 9 9 12 15 15 No and type of compressor 1 Scroll 1 Scroll 2 Scroll 2 Scroll 2 Scroll Max. pipe length lift to solar panel m 18 8 18 8 18 8 18 8 18 8 Total piping length m 1 000 1 000 1 000 1 000 1 000 Max. pipe length lift to indoor unit m 110 30 110 30 110 30 110 30 110 30 (a) Same conditions as for single splits apply (b) Number of required panels may be higher in countries and or times with low sun radiance. Actual energy consumption and number of required panels may vary and will depend on how the appliance is used and where it is located VRF Units Indoor VRF Cassettes VRF indoor units SVCC 36 SVCC 56 SVCC 71 SVCC 90 SVCC 112 SVCC 140 Cooling capacity kw 3,6 5,6 7,1 9,0 11,2 14,0 Heating capacity kw 4,0 6,3 8,0 10,0 12,5 15,0 Air flow indoor m³/h 540 780 660 865 750 1160 1120 1540 1120 1540 1280 1800 Indoor fan speeds 3 3 3 3 3 3 Sound Level (high low) db(a) 35 42 35 42 39 45 43 48 43 48 44 50 Controller Remote Remote Remote Remote Remote Remote EU grid Yes No No No No No Dimensions (HxWxD) mm 570x570x260 840x840x300 840x840x300 840x840x300 840x840x300 840x840x300 Weight kg 24 32 32 38 38 38 2 01001020101 Sedna Aire Europe GmbH 7 2014

VRF Low static pressure ducts (Hotel) VRF indoor units SVLD 28 SVLD 36 SVLD 45 SVLD 56 Cooling capacity kw 2,8 3,6 4,5 5,3 Heating capacity kw 3,2 4,0 5,0 6,3 Air flow indoor m³/h 270 530 270 530 520 770 520 770 Indoor fan speeds 3 3 3 3 Static pressure norm Pa 5 5 5 5 Sound Level (high low) db(a) 30 36 30 36 31 37 31 37 Controller Remote RM05 Remote RM05 Remote RM05 Remote RM05 Dimensions (HxWxD) mm 850x405x190 850x450x190 1030x430x190 1030x430x190 Weight kg 12 12 18 18 Warranty Years 2 2 2 2 VRF Concealed duct A5 (Offices) VRF indoor units SVDC 36 SVDC 56 SVDC 71 SVDC 90 SVDC 112 SVDC 140 Cooling capacity kw 3,6 5,6 7,1 9,0 11,2 14,0 Heating capacity kw 4,0 6,3 8,0 10,0 12,5 15,5 Air flow indoor m³/h 320 570 560 960 820 1210 860 1400 1400 1750 1250 1800 Indoor fan speeds 4 4 4 4 4 4 Static pressure norm (Lo Hi) Pa 10 (10 30) 10 (10 30) 10 (10 30) 20 (10 50) 40 (10 80) 40 (10 100) Sound Level (high low) db(a) 36 39 36 41 35 42 37 45 38 48 39 48 Controller Wired Wired Wired Wired Wired Wired Dimensions (HxWxD) mm 790x635x210 1010x635x210 1010x635x210 1230x775x270 1230x775x270 1290x865x300 Weight kg 18 27 32 40 40 49 2 VRF High static duct (1) (Halls, restaurants) VRF indoor units SVDH 71 SVDH 90 SVDH 112 SVDH 140 SVDC 140 Cooling capacity kw 7,1 9,0 11,2 14,0 20,0 Heating capacity kw 8,0 10,0 12,5 16,0 22,5 Air flow indoor m³/h 1240 1510 1510 1940 1650 2120 2230 3000 3600 4660 Indoor fan speeds 3 3 3 3 3 Static pressure norm (Lo Hi) Pa 40(30 200) 40(30 200) 50(30 200) 50(30 200) 140(50 250) Sound Level (high low) db(a) 44 48 47 52 47 52 48 53 52 59 Controller Wired Wired Wired Wired Wired Dimensions (HxWxD) mm 952x690x420 952x690x420 952x690x420 1200x600x400 1443x810x470 Weight kg 45 47 51 68 115 01001020101 Sedna Aire Europe GmbH 8 2014

VRF High static duct (2) (Halls, restaurants) VRF indoor units SVDH 250 SVDH 280 SVDH 400 SVDH 450 SVDC 560 Cooling capacity kw 25 28 40 45 56 Heating capacity kw 26 31,5 45 50 63 Air flow indoor m³/h 3600 4670 3600 4670 5000 7500 5000 7500 6550 9500 Indoor fan speeds 3 3 3 3 3 Static pressure norm (Lo Hi) Pa 140(50 250) 140(50 250) 200(50 250) 200(50 250) 200(50 250) Sound Level (high low) db(a) 52 59 52 59 56 61 56 61 57 63 Controller Wired Wired Wired Wired Wired Dimensions (HxWxD) mm 1443x810x470 1443x810x470 1970x859x668 1970x859x668 1970x859x668 Weight kg 115 115 232 232 232 VRF Convertible floor/ ceiling (restaurants) VRF indoor units SVCF 36 SVCF 56 SVCF 71 SVCF 90 SVCF 112 SVCF 140 Cooling capacity kw 3,6 5,6 7,1 9,0 11,2 14,0 Heating capacity kw 4,0 6,3 8,0 10,0 12,5 15,5 Air flow indoor m³/h 500 650 500 800 500 800 700 1200 1730 1980 1730 1980 Indoor fan speeds 3 3 3 3 3 3 Sound Level (high low) db(a) 36 40 38 43 38 43 40 45 42 47 42 47 Controller Remote Remote Remote Remote Remote Remote Dimensions (HxWxD) mm 990x660x206 990x660x206 990x660x206 1280x660x206 1670x680x244 1670x680x244 Weight kg 26 25 28 34 54 54 2 VRF Floor standing (rooms, hotel) VRF indoor units SVFS 28 SVFS 36 SVFS 56 SVFS 71 SVFS 80 Cooling capacity kw 2,8 3,6 5,6 7,1 8,0 Heating capacity kw 3,2 4,0 6,3 8,0 9,0 Air flow indoor m³/h 420 570 380 620 830 1150 870 1380 1020 1330 Indoor fan speeds 3 3 3 3 3 Sound Level (high low) db(a) 29 36 30 37 31 41 33 44 33 44 Controller Remote Remote Remote Remote Remote Dimensions (HxWxD) mm 1000x625x220 1200x625x220 1500x625x220 1500x625x220 1500x625x220 Weight kg 30 37 44 44 44 VRF Wall mounted (rooms, hotel) VRF indoor units SVWW 28 SVWW 36 SVWW 56 SVWW 71 SVWW 90 Cooling capacity kw 2,8 3,6 5,6 7,1 9,0 Heating capacity kw 3,2 4,0 6,3 8,0 10,0 Air flow indoor m³/h 430 525 480 590 755 925 680 1190 640 1320 Indoor fan speeds 3 3 3 3 3 Sound Level (high low) db(a) 29 35 29 35 34 40 39 45 41 47 Controller Remote Remote Remote Remote Remote Dimensions (HxWxD) mm 915x290x230 915x290x230 1072x315x230 1250x325x230 1250x325x245 Weight kg 13 13 15 20 20 01001020101 Sedna Aire Europe GmbH 9 2014

VRF Controllers VRF indoor units RM 05 KJR 10/12B Card Interface CCM 03 CCM 09 Controller type Accessory to Decentral Decentral KJR 10/12B Central Central Supplied units 1 indoor unit 1 indoor unit 1 KJR 10/12B 64 64 Signal Transmission Wired, Wired, Infrared connected to 3 (!) wired KJR 10/12B 3 3 Time scheduler Yes Yes n.a. No Yes Power supply 220V/50/1p 220V/50/1p 220V/50/1p 220V/50/1p 220V/50/1p Accessories Mounting Kits for Split Outdoor Units Mounting kits for safe installation of split outdoor units incl. rails, screws etc. MT SP W1 Wall Mounting MT SP W2 Wall Mounting with add. horizontal beam MT SP R Mounting on pitched roof MT SP F Mounting on floor Installation Kits for Solar Panel Installation kits, consistent of aluminum rails, L profiles, stainless steel screws, nuts and bolts SAE PITCH Pitched Roof SAE FLAT Flat Roof SAE GRND Ground Mount (same as for Flat Roof) SAE WALL Wall Mount All European certifications passed: CE EMC Sedna Aire Europe GmbH Olpketalstrasse 148 44 229 Dortmund, Germany Tel.: +49 231 7581 585 Fax: +49 231 7581 351 Web: Sales@sednaaireeurope.com www.sednaaireeurope.com Sedna Aire has a policy of continous product and product data improvement and it reserves the right to change design and specifications without notice. Solarcool TM is a trademark of Sedna Aire Europe 01001020101 Sedna Aire Europe GmbH 10 2014