How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

Similar documents
Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor.

Series IZS31. RoHS compliant

Ionizer (Nozzle type) Series IZN10

OPERATION MANUAL. Ionizer

16mm. Ionizer Nozzle type. IZN10 Series. Offset voltage ±10 v Slim design: Thickness dimension 16 mm RoHS compliant

High-frequency AC Method. panasonic-electric-works.net/sunx

Doc. No. IZ -OML0002-B OPERATION MANUAL. Ionizer PRODUCT NAME:

Nozzle Type Ionizer. 16 mm x 100 mm x 46 mm 33% reduction. IZN10E Series CAT.ES A

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

2-Color Display High-Precision Digital Pressure Switch

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

2: A, B 3: A, B, Z 4: A, A _, B, B _ 6: A, A _, B, B _, Z, Z _

Non-Contact Sensor for Workpiece Placement Verification

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Model Pressure range ON/OFF output Linear output

2-Color Display High-Precision Digital Pressure Switch

E2K-L. Liquid Level Sensor. Applications. Ordering Information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

Vacuum pump system type

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Transmitters: Relay Valve VR4151/4152

Series 10-ZSE40A(F)/10-ISE40A

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Injects ionized air over an angle of 60 or 90. Straight Bar Nozzle

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

Static Electricity Prevention Equipment

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Related vacuum products

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

How to Order M9BW. Action. Double acting Single acting. Load voltage Electrical entry direction M9NWV M9NW 12 V 5 V, M9BWV M9BW 12 V 12 V

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

MULTISTAGE MICRO EJECTORS

Digital display Pressure range ON/OFF output Linear output Model

How to Order. Lead wire length Nil L Z M9N L. Type of auto switch for detecting rotation. Nil Without auto switch. Applicable Auto Switch

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

15A (2 Form C), 10A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

Sensor specifications Model no.

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

Model Pressure range ON/OFF output Linear output

Type 2REX-A. Oil & Gas / Heavy Industry

Specifications MHC2-10D MHC2-16D MHC2-20D MHC2-25D MHC2-10S. Double acting MHC2-16S. Single acting MHC2-20S MHC2-25S. Angular style air gripper

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

Series ISA. Air Catch Sensor. For Detection of Work Presence

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

SOLENOID VALVES, SERIES

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

Compact Vacuum Ejector

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

Pilot Operated 2 Port Solenoid Valve for Dry Air

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

! Contact our sales office regarding a delivery date or a price since this is a special model. Auto switch D-M9 series mountable

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Not affected by drops, bubbles or froth

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

LCD Readout Digital Pressure Switch

Transmitters: Relay Valve

High-frequency AC Method. panasonic-electric-works.net/sunx. A new style of charge removal New ultra-compact, high-performance ionizer!

New cylinder body allows small auto switches to be mounted on 4 surfaces.

Static Electricity Removal Unit Ionizer Ion Polarity Control Type

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Remote Type Pressure Sensors Pressure Sensor Controllers

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

2-Color Display Digital Pressure Switch

3 Port Solenoid Valve Direct Operated Poppet Type

Electric Actuator/Slider Type Motor Parallel Type

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Mini Free Mount Cylinder

High Precision Scale Cylinder. How to Order. Connector. Cable suffix Nil Extension cable C Extension cable & connector

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

Operation and Installation Manual

Environment Clean Room Specification

Pilot Operated 2 Port Solenoid Valve for Dry Air

CBM-105FN/FP Circuit Board

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

Blow Type Application Examples

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Series MHS. 2, 3, 4 Finger Air Gripper D-F9P. Auto Switch Common Specifications. Auto Switch Common Specifications. Lead Wire Color Changes

Stroke Sensors INDEX. Actuators CAUTION. RoHS directive compliant products

2c 15A, 4c 10A polarized power relays

Wedge Cam Operation Slide Guide. Air Gripper/2-Finger Type ø12, ø16, ø20, ø25. Option: Stainless steel

180 Angular Style Air Gripper

Achieves high specs as a key valve for mid-sized actuators. SOLENOID VALVES The powerful and low current 280 series solenoid valves inherited the feat

Series VQ Port Solenoid Valve

Indicators reveal the sort of an abnormal condition. Emitter Emitting Controller Power indicator

Angular Style Air Gripper

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

Low Differential Pressure Sensor ±1% F.S.

Inductive Proximity Sensor

Flow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note)

LZB/LZC. Series LZB LZC. Electric Cylinder. Series. Series LJ1 LG1 LTF LC1 LC7 LC8 LXF LXP LXS LC3F2 E-MY LZB LZC

Transcription:

Ionizer / with surface potential sensor Series IZS0 How to Order 00 0 00 00 Ionizer IZ S 0 0 Bar length Bar length 00 mm 0 mm mm 00 mm 00 mm Ionizer Made to Order Bar type Size Electrode needle material Nil Tungsten C Silicon Nil S Surface potential sensor Without sensor With sensor (Sensor cable, sensor bracket attached) BS B Made to Order Bracket (End bracket, Center bracket) Nil B Power supply cable Nil With power supply cable ( m) N None Without bracket With bracket Refer to the table below. Note ) 2 end brackets are attached but not assembled. Note 2) The number of center brackets differ depending on the bar length. (Refer to the right table.) Power supply cable made-to-order component Part no. IZS0-CPM-X IZS0-CPL-X IZS0-CPZ-X No. of center brackets Bar length (mm) 00, 0, 00 00 Quantity None With pc. With 2 pcs. Note) For center bracket quantity of the non-standard bar length (-X0), refer to page 0. Contents Power supply cable 5 m Power supply cable m Power supply cable 0 m When ordering, select N (without power supply cable) to the body and order this cable separately. -X0 -X2 Non-standard bar length compliant (0 mm pitch) Changing its fittings, low particle generation spec. Specifications / Contents 0, 0, 50,, 00, 0, 0, 0, 00, 0,, 0, 0, 0,, 0, 0, 20, 22, 200 (Manufacturered upon receipt of order for 0 mm or greater length) Changing the fitting with a check valve to a hose nipple. Surface Potential Sensor, Bracket and Accessories Surface potential sensor / IZS0-D Cable Sensor cable m / IZS0-CS Power supply cable m / IZS0-CP Electrode cartridge Electrode needle material: Tungsten / IZS0-NT Silicon / IZS0-NC Electrode needle cleaning kit / IZS0-M2 Sensor cable Power supply cable End bracket / IZS0-BE Center bracket / IZS0-BM End bracket Center bracket Sensor bracket / IZS0-BS ø M5 screws for attaching Driver for ion balance adjustment trimmer / IZS0-M M screws for attaching Note) The number of center brackets required, as listed below, depends on the bar length. Bar length (mm) 00, 0, 00 00 Quantity Not required pc. 2 pcs. Axis for mounting Prepared by customer

Ionizer / with surface potential sensor Series IZS0 Specifications Ionizer Ionizer model Type Ion generation method Method of applying voltage Output for emitting electricity Ion balance Note ) Operating fluid Air supply flow rate Note 2) Air purge Operating pressure Connecting tube O.D. Power supply voltage Current consumption Sensing DC mode Input signal Emission of static electricity is suspended. High voltage irregularity Output signal Sensor irregularity Static electricity removal is completed. Effective discharge distance Operating ambient temperature, Operating fluid temperature Operating ambient humidity Material Vibration resistance Shock resistance Weight Construction While eliminating static electricity While standing by Pulse DC mode IZS0-00 IZS0-0 IZS0- IZS0-00 IZS0-00 l/min (ANR) 50 l/min (ANR) Bar type Corona discharge type Pulse DC method ±000 V ±0 V or less Air (clean and dry) 5 l/min (ANR) 0. MPa or less ø 2. V DC to 2. V DC 0 ma or less 00 ma or less 00 ma or less 0 l/min (ANR) 5 l/min (ANR) NPN transistor (open collector), or contact signal with no voltage FET (open drain), 2 V DC, 00 ma or less 50 to 00 mm 0 to 50 C 5 to 0% Rh (with no condensation) Cover of ionizer (ABS); Electrode needle (Tungsten/Silicon); Sensor body (Aluminum alloy) Durability 50 Hz Amplitude mm XYZ each 2 hours 0 g 0 g 0 G 00 g 0 g 0 g Note ) In case where air purge is performed between a charged object and an ionizer at a distance of 00 mm. Note 2) The minimum flow rate that can eliminate electricity between a charged object and an ionizer at a distance of 00 mm. Using a lower flow rate is possible if the distance is short. Surface Potential Sensor Surface potential sensor model Detection method Power supply voltage Current consumption Effective detection distance Operating ambient temperature Operating ambient humidity Vibration resistance Shock resistance Weight IZS0-D Rotating sector method 5 V DC (electricity supplied from the ionizer) Ionizer included in the sensing DC mode 50 mm or less 0 to 50 C 5 to 0% Rh (with no condensation) Durability 50 Hz Amplitude mm XYZ each 2 hours 0 G 0 g 5 2 No. 2 5 Description Ionizer Electrode cartridge Fitting with check valve End bracket Center bracket No. Description Surface potential sensor Sensor bracket Power supply cable Sensor cable

Series IZS0 Functions. Operation Mode There are different operation modes for the IZS0, which can be selected based on the application and operating condition. Operation mode The surface potential sensor detects the polarity of a charged object and continuously emits ions with the opposite polarity. Sensing DC mode Operation Features Precautions The discharge time can be shortened. After determining the existance of a charged object and that the elimination of static electricity is completed, the high voltage power supply and/or pneumatic valve may automatically turned ON/OFF. (The pneumatic valve may turn ON/OFF when the signal for static electricity removal is completed, however a pneumatic valve will be required.) The elimination of static electricity is not performed successfully even though the surface potential sensor is used. A large workpiece with an uneven electrical charge. A workpiece which shifts quickly. Static electricity elimination of the entire area and the consecutive objects. Pulse DC mode Alternatively emits positive and negative ions with a cycle of Hz to Hz. In the case of eliminating static electricity in the entire space and/or consecutive objects, static electricity removal is possible when the ion balance is stable. ) Adjustment of the actual equipment is required since the results from eliminating static electricity may differ depending on the distance of the charged objects, operating conditions, etc. 2) The surface potantial on a workpiece located directly under the ionizer, changes at a certain cycle, even after the static electricity has been eliminated. If a lower frequency is selected, the amplitude of the surface potential may become large. DC mode Alternatively emits positive and negative ions. Can also be used to build up an electrical charge on an object. Parts other than the object need to be appropriately grounded to prevent from being charged. Applied Voltage Waveform Image Mode Sensing DC mode (with sensor) Pulse DC mode (without sensor) Image of an electrostatic charged object Ion emission image + + + + + + + + + + + 2. Output Signal Signal type Static electricity removal is completed. (when using surface potential sensor) High voltage irregularity Sensor irregularity Functions Output when electricity removal on a static electricity charged object is completed or when there is no charged object. Notification that an irregular voltage is being supplied. The signal will be released by resetting the power supply after the possible cause is located and/or turning ON/OFF the signal for stopping the discharge of static electricity. Notification that the selector knob of the surface potential sensor does not rotate normally. The signal will be released by resetting the power supply after the possible cause is located and/or turning ON/OFF the signal for stopping the discharge of static electricity.. Explanation of the front panel 5 2. Power supply display Illuminates Green when power is supplied. Blinks when the power supply voltage is below the specification. 2. Sensor display Illuminates Green when the surface voltage sensor is connected.. Minus display Illuminates Blue when negative ions are generated.. Static electricity removal completion display Illuminates Green when the electricity removal is finished while sensing in the DC mode. 5. Plus display Illuminates Orange when positive ions are generated.. Irregular high voltage display Illuminates Red when an irregular current, such as a high voltage leakage occurs.. Irregular sensor display Illuminates Red when the surface potential sensor has any problems while sensing in the DC mode.. Frequency selection switch Selects the frequency for the pulse DC mode. No. 0 Hz No. 5 Hz Hz 22 Hz 2 5 Hz Hz Hz + (Generates positive ions only.) 0 Hz (Generates negative ions only.) 5. Ion balance adjustment trimmer Enables the ion balance to be adjusted, which can vary due to the installation environment, etc. For adjusting information, refer to How to adjust the ion balance on page.

Ionizer / with surface potential sensor Series IZS0 Determining the Model and Settings. Sensing DC mode ) Selection of bar length Select the appropriate length suited for a work size by referring to Electricity Removal Characteristics (reference) 2) Electricity removal range (See page.), etc. 2) Installation of the ionizer Installaton of the ionizer: Install within 0 to 00 mm of the object requiring electricity removal. For disharge time refer to the information in Electricity Removal Characteristics (reference) and ) Installation distance and discharge time (See page.). ) Installation of a surface potential sensor Position the detection hole at the charged surface and install it within 50 mm of the object. (Position the detection hole as close as possible to the object which needs static electricity removal.) ) Wiring Connect the ionizer and surface potential sensor with the dedicated cable. When the ionizer and surface potential sensor are connected with a dedicated cable, the sensing DC mode is automatically selected. Use the dedicated cable for power supply and the individual input/output. For a wiring table, refer to the Power Supply Cable, IZS0-CP Wiring Table (See page.). 5) Air piping In case of single sided piping, the fitting on the opposite does not need to be plugged because a fitting with check valve is used. Use ø piping. Regarding the air flow, refer to Specifications on page. In case the piping length is too long, piping on both sides is required to obtain the required flow rate. 2. Pulse DC mode/dc mode ) Selection of bar length Determine the length suited for a work size, referring to the information in Electricity Removal Characteristics (reference) and 2) Electricity removal range (See page.). 2) Installation of the ionizer Install the ionizer within 50 to 00 mm of the object requiring electricity removal. Regarding discharge time, refer to the information in Electricity Removal Charactristics (reference) and ) Installation distance and discharge time (See page.). ) Selection of ion generation frequency Set the selection switch with a screwdriver. Refer to the information in "Electricity Removal Charactristics (reference) and ) Operation frequency and discharge time". The selection switch's screwdriver slot is in the shape of a small arrow shape. To set, point the tip of arrow to the requested position for setting. By setting the switch to or, it will change to the DC mode which will constantly emit a + or - ion. ) Wiring For the power supply and/or input/output, use the dedicated cable. For a wiring table, refer to the Power Supply Cable, IZS0-CP Wiring Table (See page.) and Connection circuit (See page ). 5) Air piping In case of single sided piping, the fitting on the opposite does not need to be plugged because a fitting with check valve is used. Use ø piping. Regarding the air flow, refer to Specifications on page. How to adjust the ion balance When the pulse DC mode is set, the ion balance may change depending on the installation condition. Therefore, adjustment with the ion balance adjustment trimmer may be required. How to adjust ) Install the measurement equipment at the same distance as the work. 2) Adjust to approximately 0 V by using the ion balance adjustment trimmer, while reading the ion balance on the measurement equipment. Vary the trimmer by small increments. (5 or less) The ion balance adjustment trimmer will continue to rotate clockwise/counterclockwise, as shown on right. However, the ion balance will vary (One revolution, 0, equals one cycle). The condition of the ion balance changes when rotating the trimmer clockwise and rotating counterclockwise results in the opposite ion balance. 0V +tendency minimum +tendency maximum tendency maximum tendency minimum tendency minimum tendency maximum +tendency minimum +tendency maximum Precautions : Use an insulated screwdriver when adjusting the ion balance adjustment. If a metal screwdriver touches the trimmer, the values will change substantially and adjustment will not be possible.

Series IZS0 Wiring, Connection Circuit, and Input/Output Operations Power Supply Cable, IZS0-CP Wiring Table No. 2 5 Lead Contents wire color Brown 2. to 2. V DC Blue GND Green NC Gray Electricity discharge stop signal White Irregular high voltage signal Orange Red Irregular sensor signal NC Functions Power supply DC +2V Power supply 0 V. Be sure to ground it according to class D. Connect with 0 V during operation. Stop electricity discharge when the terminal is turned off. Outputs a signal when an irregular current occurs. Outputs a signal when a surface potential sensor irregularity occurs. Input/Output Operations No. 5 Description Lead wire color Electricity discharge Gray stop signal Irregular high voltage signal Irregular sensor signal Electricity removal completion signal White Orange Yellow Input/ Output Input Output Output Output Operations When operating, the static electricity discharge will stop by removing the GND and short circuit terminal. Connection circuit Tr will be powered when an irregularity occurs. Connection circuit Tr2 will be powered when an irregularity occurs. Tr is not powered when the electricity removal is completed. Yellow Electricity removal completion signal An ON/OFF signal is used to notify that the static electricity is being removed or has finished. Note ), : Only functions when the surface potential sensor is used. Connection circuit Ionizer (POWER connector) Ionizer Power supply 2. to 2. VDC GND q + 2 V DC (Brown) w GND (Blue) INPUT PLC OUTPUT F.G r Electricity discharge stop signal (Gray) Max. 2 V DC, 5 ma kω 2 V. k or INPUT t Irregular high voltage signal (White) Max. 2 V DC,00 ma OUTPUT Tr y Irregular sensor signal (Orange) Max. 2 V DC, 00 ma i Electricity removal completion signal (Yellow) Max. 2 V DC, 00 ma Tr2 Tr Internal circuit e, u NC (Green, Red) Note ) ( ): Lead wire coverage color of the dedicated cable. Note 2) Connect lead wire (Electricity discharge stop signal) to GND when operating the ionizer and the operation will stop when the terminal is removed. Note ) Lead wires (Irregular sensor signal) & (Electricity removal completion signal) will only provide a signal when the surface potential sensor is used.

Ionizer / with surface potential sensor Series IZS0 Dimensions Ionizer (IZS0- ) L 0 0 -M x 0. depth 5 (For mounting) Similarly threaded on the opposite surface Electrode cartridge IZS0-NT 25 End bracket (IZS0-BE) M5 screw for mounting (Prepared by customer) 0 x (n-) 0 P modular jack (Plug for sensor cable) P modular jack (Plug for power supply cable) n (No. of Electrode Cartledges), L Part no. IZS0-00 IZS0-0 IZS0- IZS0-00 IZS0-00 n 2 L (mm) 00 0 00 00 Accessory screw M x 0 l 0 Center bracket (IZS0-BM) (2) 0 Ionizer full length (L) 0 0 2 (2) Angle adjustable (±0 ) M5 screw for mounting (Prepared by customer) 0 ø2 5. 52 5 2-Air supply port Fitting with check valve: AKH0B-M5-X25 Frequency selection switch Ion balance adjustment trimmer 2-5. 2 2 Note) The number of center brackets to be attached differs depending on the bar length. (Refer to How to Order on page.) Angle adjustable (±0 )

Series IZS0 Dimensions Surface potential sensor (IZS0-D) 2 x 2 -M5 x 0. depth (Same location on the opposite surface) 2 -M5 x 0. depth Detection hole P modular jack.5 0 0.5 5 Sensor bracket (IZS0-BS) Axial for mounting ø (Prepared by customer) Mounting hole ø Mounting image 2 0 ø Accessory screw M5 x l F F IZS0-D Power supply cable (IZS0-CP) 000 +0 0 5 Sensor cable (IZS0-CS) 000 +0 0

Series IZS Made to Order For detailed dimensions, specifications and delivery time, please contact SMC. Made to Order Non-standard bar length compliant (0 mm pitch) -X0 Compliant bar length (mm): 0, 0, 50,, 00, 0, 0, 0, 00, 0,, 0, 0, 0,, 0, 0, 20, 22, 200 Manufacturered upon receipt of order for 0 mm or greater length. Bar length No. of Center Brackets Bar length (mm) Quantity 0 to 00 None 0 to 0 With pc. 0 to 200 With 2 pcs. For How to Order, refer to page. 2 Changing its fittings, low particle generation spec. -X2 For How to Order, refer to page. Changing the fitting with check valve to a hose nipple, resulting in reduced particle generation from the one-touch fitting with a check valve. Caution This product is not washed. If required for use in a clean room, please confirm that the product meets the required cleanliness by flushing for several minutes prior to use. Dimensions L 0 5 52 2-piping port for air purge M5 x 0. Frequency selection switch Ion balance adjustment trimmer n x electrode cartledge 2 x -M x 0. depth 5 (for mounting) 0 Accessory fittings (2 pcs) Applicable tubing O.D.: ø 25 0 x (n-) 0 P modular jack (for sensor cable plug) P modular jack (for power supply cable plug) When mounting an accessory fitting n (No. of Electrode Cartledges), L Part no. IZS0-00 -X2 IZS0-0 -X2 IZS0- -X2 IZS0-00 -X2 IZS0-00 -X2 n L (mm) 00 0 00 00 When mounting an accessory plug Accessory plug Note) Note) Plug the other side using the accessorised plug in case of the single sided fitting connection. (We recommend that both sides should be connected when the bar length is mm or greater.) Power supply cable, made-to-order component -X How to Order IZS0 CP M X Power supply length total length M 5 m L m Z 0 m Refer to page, Power Supply Cable, Wiring Table for wiring diagrams. L 5 L Dimension Part no. IZS0-CPM-X IZS0-CPL-X IZS0-CPZ-X L (mm) +0 5000 0 +0 000 0 +0 0000 0 0