3V SERIES SOLENOID VALVE

Similar documents
4V130P-430P SERIES AIR PILOT VALVE

STC 2L Series Solenoid Valves

2V1-3V1 SERIES SOLENOID VALVE

STC 2W Series Solenoid Valves

STC 2P025 Series Solenoid Valve

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

STC 2E Series High Pressure Solenoid Valves Two-Way, Pilot Piston, Normally Closed

S T C. STC Air Actuated Valves. Fine Quality. Precision Engineered Advanced Design. Excellent Prices. connects fluid power to industrial automation TM

STC. Manual & Actuated Process Valves. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Solenoid & Process Valves

STC KS/KD Air Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

STC 2W160 Series Solenoid Valves

KS/KD Air Actuated Ball Valves

AIR & ELECTRIC ACTUATED VALVES

STC Air Cylinders. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Air Cylinders

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

HR-20P Pneumatically Controlled Pressure Regulator

Bulletin H-Tech 03 High Pressure Valves Series H

37SCENE 46SCENE 79SCENE

Locoloc Swaging Tools

BI-PIPE INSTALLATION MANUAL. AUDI PERFORMANCE & RACING 1027-B Opelika Road Auburn Alabama 36830

II DISTRIBUTION & SUBSTATION TYPE C

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

DAP-625S and DAP-875S

Straight-Bore Clutch LSCC-32, 44, 54

2006 SHOCK TOWER BRACE 93-UP F-BODY CAMARO/FIREBIRD

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

END USER TERMS OF USE

FCB-450, LCB-600, MCB-800

OWNERS MANUAL JANUARY 2007 ISO

22421 SPORT SWAY BAR SET TOYOTA COROLLA

PIVOT BUSHING KIT GM F-BODY

2015 & 2018 Fender Brace Installation Instructions

Installation and Operation Guide for PD5100 Automatic Transfer Switch

INSTALLATION INSTRUCTIONS

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Sport Sway Bar Kit UP SCION xb

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

HC-5010-R Operator s Manual

Camaro / Firebird. Please read the following key points before installing this kit.

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

PVC Gasketed Fittings for PVC IPS Pressure Pipe ENGINEERED FOR DURABILITY

P/N# Performance Lowering Springs Installation Instructions

2282R GM A Body Extreme Rear Sway Bar

K-Motion Valve Springs are the choice of winning racers. K-Motion

ADI-125/750 ADI-125/1500 ADI-125/2500

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

16385 Steering Tie Rods Chrysler A-Body

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

STC Solenoid Valve List Price

Item no Smart AC 200 USB. User s Manual

SUNTURA SOLAR TRACKER

GWC Valve International

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

Terms and Conditions

10 Year Limited Warranty

Rear Sway Bar Kit 22390R C-10 Truck

VERTICAL AND HORIZONTAL SPLIT CASE FIRE PUMPS

Do not install and/or operate this safety product unless you have read and understand the safety information contained

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

Warner Electric UNIBRAKE Motor Brakes

Rear Suspension System C-10 Pickup Truck

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

1313 LOWER TRAILING ARMS CHEVROLET B-BODY

LINTECH.

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS

SUNTURA HD SOLAR TRACKER

Sport Sway Bar Kit Chevy Camaro

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

Please read the following key points before installing this kit.

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

BMRX Series ROTARY LEVEL CONTROL

Operating Instructions & Parts Manual. Oil Control Gun. Models 48UJ82, 48UJ83, 48UJ84, 48UJ85 and 48UJ86

GORE TRAILER MANUFACTURING INCORPORATED 305 Gore Trailer Road Whiteville, North Carolina 28472

SPORT COIL SPRINGS Scion xa & xb Part #19412 INSTALLATION OF HOTCHKIS FRONT COIL SPRINGS

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

HSIV PLOW OPERATOR S MANUAL

PVI 60KW, PVI 82KW, PVI 95KW

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

MIL-24/2600Q MIL-24/3200DQ

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Installation and Tuning Instructions for TM Multi Carb linkage kit PLEASE READ INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

Freedom Designs, Inc. Embroidery Catalog. Over 50 New Design Options! Freedom 12Pg Embroidery Self Cov 1

430B SERIES HORIZONTAL SPLIT CASE PUMP

1107 Tubular Upper A-Arms Camaro/Firebird

Transcription:

3V110-410 SERIES SOLENOID VALVE Valve Model 3V110-1/8 3V210-1/4 3V310-3/8 3V410-1/2 Port & Mounting Action & Motion Operating Pressure Body Ported Air Pilot, Spool Design, Response Time <20 ms 21-115 PSI Port Sizes 1/8 NPT 1/4 NPT 3/8 NPT 1/2 NPT Operating Temp. 14-140 F C v 0.67 0.89 1.68 2.79 SFCM @ 100PSI 25 53 80 160 Manual Override Non-Detentable Detentable Electrical Connection Working Medium Coil Insulation & Protection Class Coil Duty Cycle Coil Voltage Options Grommet, DIN 40 micron filtered air or inert gas IP 65, Class F 100% ED (Continuous Duty) Options: 12, 24 VDC; 24,110/120, 220/240 VAC (50/60Hz) Coil Power 2.5W 3/4.8W Valve Body Material Anodized Aluminum Seal Material NBR (Buna N) Lubrication Not Required 1

3V110-410 SERIES SOLENOID VALVE DIMENSIONS 2

3V110-410 SERIES SOLENOID VALVE DIMENSIONS 3

Note: This valve is designed for air flow only. 3-Way Solenoid Valve Models 3V110-3V410 Installation Procedure Warning: Do NOT over tighten the nut holding the coil to the armature tube. Over tightening may result in damage to the welded joint. Attaching a Coil to a Valve: 1. After wiring the coil, fit the coil assembly over the armature tube. Ensure that the threads of the tube are accessible. 2. Fit the spring or lock washer over the assembly. o For spring washers, the concave side should be oriented toward the coil. 3. Tighten the nut over the washer by hand. o For spring washers, tighten the nut further until the spring coil is almost completely flat. o For lock washers, tighten the nut another quarter turn. Installing a Valve onto a Manifold: Note: Manifolds can fit 2, 4, 6, 8 and 16 valves. Secure screws until the component will not move freely, and tighten another quarter turn. Procedure: 1. Place a rubber seal over the manifold openings. 2. Line up the valve with port A and corresponding pilot holes for the screws. 3. Secure the valve into place. 4. Cover the remaining holes with the provided gaskets. Installation: 1. Connect the source to the port labeled P. 2. Connect the outlet to the port labeled A. 3. Connect the exhaust to the port labeled EA. Maintenance and Troubleshooting Note: After an extended period of operation, if you do not hear a clicking sound when the valve is operational, and the wiring is correct, the coil may be burned out and must be replaced. This commonly occurs when input voltages are higher than the coil s specifications. Procedure: 1. Remove any coils attached to the valve. 2. Unscrew the holding plate and the armature tube and remove it from the valve body. Remove the piston and the spring. 3. Check for any debris that may have collected on the piston and the hole in the center of the valve. 4. Insert the piston and spring back into the valve body. 5. Screw the armature tube and holding plate back into the valve. Reference Figures Figure 1: Model 3V110 with port labels shown. 4

Installation of 3V100-400 and 4V100-400 Solenoid Valves Connect the 3V100-400 3 way valve inlet and out as shown in the diagram : P = Air Supply Port A = Outlet A Port EA/EB = Exhaust Outlet A (Connection Optional) Connect the 4V100-400 4 way valve inlet and out as shown in the diagram : P= Air Supply Port A = Outlet A Port B = Outlet B Port EA = Exhaust Outlet A Port (Connection Optional) EB = Exhaust Outlet B Port (Connection Optional) Connection of 3V100 400 & 4V100-400 Solenoid Coils Electrical Connections To connect DIN coils: 1. Remove the Philip screw from the plastic housing and unplug it from the DIN coil. 2. From the screw opening, use the screw to push the terminal block out of the plastic housing. 3. Note the 1, 2 and ground markings on underside of DIN enclosure. 4. For DC DIN Coil, Connect 1 to Positive, 2 to Negative. 5. For AC DIN Coil, connect 1 to HOT wire, 2 to Neutral wire, and if required connect ground to ground wire. To connect Grommet coils or Lead Wire DIN coils: DC Coil: 1. If the DC solenoid coil has a red and a black wire, Connect Positive to RED wire and Negative to Black wire. 2. If the DC solenoid has two same color wires, connect Positive to one of the two wires and Negative to the other wire. AC Coil: 1. If the AC solenoid coil has a black a white wire, Connect the HOT wire to BLACK wire and Neutral to WHITE wire. 2. If the AC solenoid has two same color wires, connect HOT wire to one of the two wires and NEUTRAL wire to the other wire. Do not energize the coil without installing it onto the valve, it will burn the coil and create fire hazards. 5

STC Installation and Operation Procedure 3V110-3V410 & 4V110-4V410 Solenoid Valves 3V110-3V410 (3 way valve) SOLENOID VALVE POSITION 1 2 Operations: 1. When Solenoid is OFF (Position 1), Port A is connected to Port E. Port P is closed 2. When Solenoid is ON (Position 2), Port P is connected to Port A. Port E is closed. 4V110-4V410 (4 way valve) SOLENOID VALVE POSITION 1 2 Operations: 1. When Solenoid is OFF (Position 1), Port P is connected to Port A. Port B is connected to Port EB. 2. When Solenoid is ON (Position 2), Port P is connected to Port B. Port A is connected to Port EA. 6

Catalog No.: PUB 2012 3V110-410 Terms and Conditions By purchasing from SIZTO TECH CORPORATION (STC), you agree to these TERMS AND CONDITIONS. No other terms shall apply except as agreed in writing signed by us. We reserve the right to correct typographic errors and reject orders. SHIPMENTS: All shipments are F.O.B. 892 Commercial Street, Palo Alto, CA 94303, USA. Most orders are shipped via UPS Standard Ground unless instructions accompany order. Outside the UPS zones, shipment will be made Best Way. The responsibility for goods delay, lost or damaged in transit rests with the carrier and purchaser. Purchaser may purchase shipping insurance to cover lost or damaged products caused by shipping. RETURN OF MERCHANDISE: No merchandise is accepted for return 30 days after delivery date. No credit allowed on merchandise shipped as ordered and returned without obtaining an authorization number IN ADVANCE. A 20% restocking charge applies to all returns, and transportation charges must be fully prepaid. We will pay ground transportation charges on re-sent or returned merchandise due to STC's error. Shortages & Mis-Shipments: Any shortages or mis-shipment must be reported within 15 days. CANCELLATION POLICY: Blanket order can be canceled 90 days before scheduled ship date. There will be a 10% charge if a blanket order is cancel within 90 days of scheduled ship date, and a 20% charge if cancel within 60 days. Regular order for non-custom parts can be canceled any time before the order is shipped. For custom parts, a 30% down payment is required either at the time of order or 90 days prior to scheduled ship date, whichever comes later.. Remittances should be sent to: Sizto Tech Corporation, 892 Commercial Street, Palo Alto, CA 94303, USA Credit Card Payments: Visa, MasterCard, Discover, or American Express Accepted International Customers: Advance Payment Required via Bank Wire, Cashier's Check or Approved Credit Card. Credit Application: To establish a net 30 day account, please mail or fax three trade references with complete mailing addresses and account numbers. LIMITED WARRANTY IMPORTANT NOTICE TO PURCHASER: Sizto Tech Corporation (STC) only warrants this product to be free from defects in materials and workmanship at the time of shipment. This limited warranty expires one year after delivery to the end-user. STC s entire obligation to the Purchaser for breach of this limited warranty shall be limited to replacement of the defective product or refund of the original purchase price of this product, at STC s option. Purchaser has thirty (30) days to return the goods after STC has agreed to accept the return. All freight charges on returned material shall be paid by the Purchaser. STC s limited warranty shall not apply, however, to the product that have been subjected to misuse, alteration, accident or negligence during handling or storage.. DISCLAIMER OF IMPLIED WARRANTIES: All implied warranties, which may arise by implication of law or application of course of dealing or usage of trade, including, but not limited to, implied warranties of merchantability or fitness for a particular purpose are expressly excluded. There are no warranties, which extend beyond the description of the faced hereof. The end user is solely responsible for the suitability and fitness of this product selected for a particular application. OBLIGATIONS You warrant, represent and agree: (1) to comply with all laws; (2) that our sale and shipment of the product will not, by export thereof, your legal status or otherwise, cause us to violate any law; and (3) to indemnify us against any losses from a failure by you or a third party to comply with law or these terms and conditions, or from use of the product. SAFETY WARNING Failure or improper selection or improper use of the components and products described herein or related items can cause death, personal injury and/or property damage. This document and other related information from STC provide products options for further investigation by users having the technical expertise. It is important that you analyze all aspects of your application and review the information concerning the component or product in the current catalog. Due to the variety of operation conditions and applications for these components or products, the user, through his own analysis and testing, is solely responsible for making the final selection, installation and maintenance of the products and assuring that all performance, safety and warning requirements of the application are met. All products set-ups and maintenance require the supervision of a qualified individual who is familiar with installation, inspection and testing through training or experience. IMPORTANT NOTICE: The products described herein, including without limitation, product features, specifications, design, availability and pricing, are subject to change without notice. We continuously improve the products, and we reserve the right to change specifications without incurring any obligation to incorporate new factors in equipment previously sold. Information contained herein may be changed without prior notification. S T C Sizto Tech Corporation 892 Commercial Street Palo Alto, CA 94303 USA Tel: 650-856 8833 Fax: 650-856 8811 Email: Sales@StcValve.com; www.stcvalve.com 7