M400 Series Double Locks. Features

Similar documents
* * M400 Series Double Locks. Double Electromagnetic Locks: M422, M452, M492. Installation Instructions. Mounting Bracket (2)

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

M670/M680BD MAGNALOCK SERIES Installation Instructions

INSTALLATION 8310/8320

280+ SHEARLOCK INSTALLATION AND WIRING MODELS: 280+ and 280+TRD TRD

Package Contents. Mounting Hardware

GLANCE. Refer to Installation Guide Booklet before attempting to install. Phone:

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

Pre-Installation Instructions

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS

TRAC-Station BT Installation Instructions

CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

1-3/4" MOUNTING INSTRUCTIONS: 1150 SERIES SURFACE MOUNTED 1500 LB. ELECTROMAGNETIC LOCK

DynaLock 705 Emmett Street Bristol, CT Phone:(860) Fax:(860)

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

Installation Instructions

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE ELECTROMAGNETIC LOCK.

LED Recessed Troffer Retrofit Kit

LOCKNETICS MagForce+ Series. Locknetics MagForce Traffic Control Magnet MEA

With LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA lb.

MagForce+ The Positive Force in Electromagnetic Locks

Installation Guide(s)

INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

HOW TO TELL HAND OF DOOR:

Electrical Options Booklet. Table of Contents

2965 Magnetic Shear Lock Installation Instructions

INSTALLATION DESCRIPTION

CA-110 Installation Instructions

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Installation Instructions

Installation Instructions RF4510-EA

Installer Guide smart connect

Security Door Controls

Remote Keyless Entry Installation Guide ca 2051

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

HANDLING MECHANICAL INSTALLATION

MODEL 3002xTJ32 ELECTROMAGNETIC LOCK INSTALLATION INSTRUCTIONS

TS93 EMF T/PT/TDE. Surface applied door closer

Excel Series Value Engineered Access Hardware

STANDARD / DOUBLE STANDARD MAGNETIC LOCK

Driver/Left Rear Inner Support Bracket. (2) Front Bracket Arms

Endcap P/N: Pushpad Wrap P/N: X (3-0) P/N: X (4-0)

CSI-400 Installation Instructions

Paxton. ins us. Paxlock US

cel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

General Description. Product Specification. Document Digital Temperature Interlock

ESA II. I - Revive Slider Conversion Kit. Installation instructions

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

Standard Plastic Template P/N: (3-0) P/N: (4-0)

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

Keys and Locks. Keys. Protect the keys from direct sunlight, high temperature, and high humidity.

*24213* 4040-SE Sentronic. 1 Voltage. 6 Adjusting Hold-Open Door Position. 7 Regulation. 2 Tracking. 8 Door Closer Cover.

Owner s Guide. For Model: PE5BZ. Flashlogic FLRS RF Upgrade Kit

Security and Keyless Entry Installation Guide ca 1051

CSI-300 Installation Instructions

* * Maintenance Kit

versatile 4C mailbox suites

Chevrolet 3100 IFS Kit

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

CSI-100 Installation Instructions

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty.

RECESSED MAGNALOCK MODEL M34R SERIES INSTALLATION AND OPERATING INSTRUCTIONS

SLIM LINE FUME HOOD MONITOR

ADA EZ Rev. H, 8/23/11

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK

II E INSTALLATION INSTRUCTIONS MODEL 1550K-VD ELR FIELD INSTALLABLE KIT

*D-1015* D PARTS CHECK F-XX-V & XX-V EXIT DEVICES INSTALLATION INSTRUCTIONS. Customer Service

INSTALLATION INSTRUCTIONS CRL JACKSON 2085E

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

EVO-1162 EVO Tailgate Tire Carrier

Installation Instructions: Read these instructions in its entirety before performing any installation work.

*24191* 4040SEL Sentronic. 35 ft-lbs 48 N-m 62 N. Installation CAUTION. Customer Service. Installation Instructions

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

Hendrickson Fit Adapter Installation Instructions

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

*28101* 4600 Electronic Low Energy Operator Installation Instructions 4630 PULL SIDE MOUNT 4640 PUSH SIDE MOUNT. Table of Contents.

INSTALLATION INSTRUCTIONS MICRO SHEAR EMLOCKS 1561 & 1562 MAX. HOLDING FORCE 2000 LBS.

INSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs.

Installation Instructions for John Deere cotton picker models: 9986 & 2-row and All-row systems included.

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation & Programming Manual. Quick Reference

Auto-Lift Operating System

E-941SA-300RQ. Manual. 300-lb Single-Door Electromagnetic Lock with Reversible Magnet

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

DC3000 Series. Door Closers

*24828* 1 Installation. Left Hand Shown, Right Hand Opposite. Customer Service

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device

INSTALLATION PROCEDURE, HHT WITH BULKHEAD. Vehicle prep

Installation Manual. for Off Line Systems. INTELLIKEY is a trademark of INTELLIKEY Corporation GID 04/25/2003. Page 1

*29268* 4600CS Electronic Low Energy Operator 4630CS PULL SIDE MOUNT 4640CS PUSH SIDE MOUNT. Table of Contents. Customer Service

CNCTRK AZ/EL Positioning Unit Assembly Instructions. Rev

Transcription:

*44487304* 44487304 M400 Series Double Locks Double Electromagnetic Locks: M422, M452, M492 Installation Instructions Automatic Voltage Selection (AVS) Magnet immediately detects 12VD or 24VD when power is connected. Anti-Tamper Switch (ATS) An indication is provided should the magnet cover become unsecured from lock. Features Magnetic Bond Sensor (MBS) Detects proper bond between magnet and armature. It can be monitored remotely and locally with an LED. LED Provides local indication of MBS status. Door Position Switch (DPS) Indicates whether door is open or closed. This feature is used in conjunction with the MBS. Relock Time Delay (RTD) Relock time can be changed. Range is 1-30 seconds. Models Trims M422 (Traffic ontrol) UL1034 and 10/500 lb and 3 hr rating M452 (High Security) UL1034 and 10/1000 lb and 3 hr rating M492 (Max Security) UL1034 and 10/1500 lb and 3 hr rating. Trims Basic Auto Voltage Selection (AVS) for 12 or 24VD Plus Basic features + Door Position Switch (DPS), Magnetic Bond Sensor (MBS), Relocking Time Delay (RTD), LED Status Indicator (LED) and Anti-Tamper Switch (ATS) Units shall not impair operation of panic hardware mounted on door. Units shall not impair intended operation of an emergency exit. Not to be used without UL approved latching hardware. Units/Models are intended to be connected to UL Listed Equipment, not intended for Burglar or Fire Alarm Initiating or Indicating Devices. Ambient onditions - For Indoor Use Only. Wiring methods shall be in accordance with the National Electrical ode, ANSI/NFPA 70. UL Requirements This device complies with part 15 of F rules. Operation is subject to following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including any interference that may cause undesired operation. hanges or modifications not expressly approved by party responsible for compliance could void user s authority to operate equipment.

Electrical Specifications Model Amps (12VD) Amps (24VD) Holding Force (lbs) Per Lock Per Lock Per oil M422 1.500 0.760 500 M452 1.500 0.760 1000 M492 1.300 0.700 1500 Lock Installation 1 Prepare for installation. 1a Lock orientation Locks should be installed with wiring covers in the middle, so the magnet in one of the locks must be reoriented. Shown from Exterior Magnet Wiring overs Magnet 2

1b Reorient magnet and board (if necessary) Remove screws, wiring cover and end blocks. Rotate magnet, end blocks and wiring cover as shown, then reassemble. End Block Magnet Magnet End Block Wiring over 1c Place template and mark holes Place template on top centerline of doors. Mark holes and prepare them per template. 3

2 Install MBS indicator (optional, Plus models ONLY). 2a Remove cover. 2b Drill hole for MBS indicator. 0.75" (19 mm) 0.25" (6 mm) hole Bottom M420: 0.50" (13 mm) M450/490: 0.75 (19 mm) ¹ ₄" (6 mm) drill bit 2c Install MBS indicator 3 Install ATS (Plus models ONLY). 3a Remove end block and wiring cover. 3b Install ATS and reassemble. b c a f d e ATS 4

4 Attach armatures to doors. Install as shown. 2x Armature holder screws must be flush to inside of armature holder. 4a Install armature plate as shown for door type. Wood Door Reinforced Metal Door Hollow Metal Door Sex Nut Armature Bolt* Armature Bolt* Sex Nut Armature Bolt* Z\x hole through Armature Holder Flat Washer Star Locking Washer one Washer Armature Plate Drill and tap for B\zn - 18 machine screw Armature Holder Flat Washer Star Locking Washer one Washer Armature Plate Z\x hole ZZ\cx hole Armature Holder Flat Washer Star Locking Washer one Washer Armature Plate Armature bolt must be tightened to 120 in-lbs. orrect Incorrect 5

5 Install mounting brackets into frame. 5a Attach mounting brackets temporarily. Install alignment tool onto brackets. Install four (4) screws into slotted holes and partially tighten. Actual Size Metal Wood Alignment tool Wires 5b Remove wiring covers and end blocks. 5c Slide one magnet onto bracket. 6

5d Slide second magnet onto bracket. 5e Align magnets to armatures lose doors. Press magnets to fully engage with armatures. Mark brackets on ends. Mark here (both sides) INSIDE Press magnets to armatures 5f Remove magnet and snug two (2) outer screws. 5g Align enter of Brackets Using Alignment Tool Loosen two (2) innermost screws. Place alignment tool over brackets. Tighten all four (4) screws. Snug these two screws Loosen these two screws 7

5h Verify magnet adjustment. lose door and verify magnets make full contact with armatures. If alignment is satisfactory, go to step 5i. If further adjustment is required, repeat steps 5e through 5h. 5i Prepare additional holes. Install alignment tool on brackets. Fully tighten four (4) screws. Drill eight (8) remaining holes. Use #10-24 tap if metal is reinforced. INSIDE Magnets making full contact with armatures Fully tighten four screws 5j Install eight (8) screws Remove alignment tool. Install and fully tighten eight (8) screws. Actual Size Reinforced Metal Sheet Metal 8

6 Attach magnets to mounting brackets. 6a Slide one magnet onto bracket. 6b Install joining block into lock. 6c Slide second magnet onto bracket. Align with joining block. 6d Secure locks with four (4) screws Actual Size 9

7 orrect wiring to board (standard model) 7a Review wiring connections. Mag Lock Board Mag Lock Board D (+) D (+) TB1 D (-) D (-) TB1 From Magnet From Magnet D (+) D (-) 7b onnect wires to boards. 7c Install covers. From Door Frame D Power Wires From Magnet 10

8 onnect wiring to board (Plus model) 8a onnect outside wires to boards. hoose between or. Normally Open () Wiring in Parallel Switch position will be closed when doors are closed and locked. To be used with normally open terminals Mag Lock Board Normally Open () MBS MBS Normally Open () DPS DPS Mag Lock Board DPS: 0.25A, 30VD, DPS: 0.25A, 30VD, MBS: 1A, 30VD, MBS: 1A, 30VD, D Power D (+) D (-) D (+) D (-) D Power D(-) D(+) Normally losed () Wiring in Parallel Switch position will be open when doors are closed and locked. To be used with normally closed terminals Mag Lock Board Normally losed () MBS MBS In Out Normally losed () DPS DPS In Out Mag Lock Board DPS: 0.25A, 30VD, DPS: 0.25A, 30VD, MBS: 1A, 30VD, MBS: 1A, 30VD, D Power D (+) D (-) D (+) D (-) D Power D(-) D(+) 11

8b Review plug locations. Mag Lock Board TB3 From MBS From MBS Note: Two MBS plugs are interchangeable TB2 RED RTD Adjuster TB1 Min. Time Max. Time Polarized Black/Red From LED From Magnet 8c onnect plugs to boards. 8d onnect ATS wires. ATS From LED From MBS From MBS From Magnet (violet) (gray) (white) Switch Rating: 1A @ 30VD, 8e Install covers. ustomer Service 1-877-671-7011 www.allegion.com/us Allegion 2014 Printed in U.S.A. 44487304 Rev. 01/14-e