Ultra Mag SUBMITTAL PACKAGE

Similar documents
FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Full Profile Insertion

imag 4700 SERIES FLANGED MAGMETER

F-2700 SERIES INSERTION VORTEX FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER

ISTEC MAGNETIC METERS

F-2600 SERIES INLINE VORTEX FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-2700 SERIES INSERTION VORTEX FLOW METER

Flow Measurement Solutions for Water & Waste Water INSTALLATION OPERATION & MAINTENANCE MANUAL

Propeller Meters. Flow measurement solutions for water and wastewater

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

Appendix. Clearance. Skewed profiles. Application Schematics

Octave Water Meter Installation Manual

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Electro-Magnetic Flowmeters Sensors MagMaster MFE

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

Electromagnetic Flowmeters. Product Overview.

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch.

Insertion Flow Meters. Municipal Market Customer Presentation

F-2600 SERIES INLINE VORTEX FLOW METER

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

Hydro-Flow Model 2200 Installation and Operation Guide B

Instructions EM 101 Low Flow Electromagnetic Flow Meters

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Rosemount 8750WB Magnetic Flowmeter System

UTM10 Series Ultrasonic Transit-time Flowmeters

SIGNET 7002 Vortex Flow Sensor ENGLISH

Propeller. Flowmeter. Technology. For the Real World.

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

Field IT Electro-Magnetic Flowmeters Sensors

Hydro-Flow Model 3100


F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

UniMag DT Series Electromagnetic Flow Tubes

SERIES FLMG MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

DURA MAG BATTERY POWERED ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL Rev. 1.

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter for hazardous areas

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Range of Ultrasonic Flowmeters.

AG2000 IRRIGATION MAGMETER INSTRUCTIONS

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

Magnetic Inductive Flowmeter EP / UMF2 (B)

M3500 Industrial Pressure Transmitter

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

Liquid Turbine Flow Meter OwnerÊs Manual

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

ML255 ELECTROMAGNETIC FLOW METER CONVERTER

Hydro-Flow Model 2300 Installation and Operation Guide B

VLM20 In-line Vortex Flowmeter

F-2500 SERIES VORTEX METER

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications

Signet 2551 Magmeter Flow Sensor

ProcessAutomatic EZ-Mag

imag ISO 9001:2008 Municipal/Industrial Magmeter Instructions Flow Meters & Controls 9 001:2008 ISO CERTIFIED COMPANY CERTIFIED COMPANY

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Electromagnetic Flow Meter Owner s Manual HARDWARE

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

SIGNET Vortex Flow Sensors ENGLISH

mass flowmeter for compressed air

Signet 7000/7001 Vortex Flow Sensors * *

PMG MAGNETIC FLOWMETER

Model FVP General Specification. Flanged Vortex Plate. Product Features

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Options guide. Electromagnetic flowmeters. M9xx

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Model 395L Full Profile Insertion Electromagnetic Flowmeter Forward Flow

LNII Series Motor and Drives

Application Engineering

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Vortex Plate. Model VP General Specification. Product Features

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

Installing Power Components

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

MagFlux Q 8200 Series

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Hot Tap Insertion Vortex

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Electric Actuator Instructions

Dissolved Oxygen Measurement System with Air Blast Cleaner

Signet Pressure Transmitter

A Member of the. Integrated Metering Technologies

Model TUR-200D Turbine Flowmeter

Transcription:

SUBMITTAL PACKAGE Date: McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 PHONE (951) 652-6811 TOLL FREE (800) 800-8804 FAX (951) 652-3078 www.mccrometer.com 3255 WEST STETSON AVENUE HEMET, CALIFORNIA 92545 USA Printed In The U.S.A. TEL: 951-652-6811 800-220-2279 FAX: 951-652-3078 Lit. # 30107-10 Rev. 2.3 / unreleased

PROJECT NOTES Project Name: Purchase Order No.: Date: Customer Name: Submitted By: Equipment being purchased: Included Items: sensor (UM06 or UM08 as noted above) Liner technology with NSF fusion bonded epoxy coating Stainless Steel Electrodes 2-Year Warranty Selectable Items: Electrodes Material: Flanges: Meter Mount Converter or Remote Mounter Converter with feet of cable Converter Power: (Check One) A/C Power D/C Power Special (Optional): Modbus Protocol RS485 Converter Hart Converter Profibus Converter See Configuration Sheet and drawings as follows for sizing and option details. 3255 WEST STETSON AVENUE HEMET, CALIFORNIA 92545 USA Printed In The U.S.A. TEL: 951-652-6811 800-220-2279 FAX: 951-652-3078 Lit. # 30107-10 Rev. 2.3 / unreleased Copyright 2012-2016 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published technical data and instructions are subject to change without notice. Contact your McCrometer representative for current technical data and instructions.

And SIGNAL CONVERTER DESCRIPTION MODELS UM06 AND UM08 FLANGED TUBE meters are manufactured to the highest standard available for magmeters. They incorporate microprocessor technology to offer very low flows and broad range ability. The flanged end tube design permits use in a wide range of applications with up to 300 PSI working pressure. Flanged ends are: Steel AWWA Class "D" flat face flanges (150 PSI) for UM06 Steel AWWA Class "F" raised face flanges (300 PSI) for UM08 (2", 3", and 14") Steel ANSI 300 lb. Raised Face Flanges for UM08 (4" - 12") The fabricated tube is stainless steel with steel or stainless steel flanges and is lined with Liner, an NSF approved, fusion bonded epoxy material. INSTALLATION is made similar to placing a short length of flanged end pipe in the line. The meter can be installed vertically, horizontally, or inclined on suction or discharge lines. The meter must have a full pipe of liquid for proper operation. Fluid must be grounded to the downstream flange of the sensor either via internal grounding electrodes (4-12") or using McCrometer 316 SS Grounding Rings. For best performance, grounding rings are recommended for all sizes. Any 90 or 45 degree elbows, valves, partially opened valves, etc. should not be placed closer than one pipe diameters upstream and zero pipe diameters downstream. All blending and chemical injection should be done early enough so the flow media is thoroughly mixed prior to entering the measurement area. SIGNAL CONVERTER: The signal converter is the reporting, input and output control device for the sensor. The converter allows the measurements, functional programming, control of the sensor and data recording to be communicated through the display and inputs/outputs. The microprocessor-based signal converter has a curve-fitting algorithm to improve accuracy, dual 4-20mA analog outputs, an optional RS485 communication port, an 8 line graphical backlit LCD display with 3-key touch programming, and a rugged enclosure that meets IP67. In addition to a menu-driven self-diagnostic test mode, the converter continually monitors the microprocessor s functionality. The converter will output rate of flow and total volume. The converter also comes standard with password protection and many more features. ISOLATED POWER AND SIGNAL: The power and signal between the converter and sensor are isolated and placed in separate cables giving superior resistance to electrical signal noise compared to single cable designs. An added benefit from the dual cable design is a maximum cable length of up to 500ft. OPTIONAL: DC powered converter (10-35 VDC, 21 W) Meter mounted converter Extended warranty Hastelloy electrodes ANSI or DIN flanges Quick Connect cable fittings Special lay lengths, including ISO standard lay lengths Converter sun shield Modbus Protocol RS485 converter; HART Converter; Profibus Converter (No Dual 4-20mA on HART & Profibus); Smart Output (Sensus or Itron compatible); Panel mount converter (Not CSA approved); Battery or battery-solar powered converter (Not CSA approved, ±1% accuracy) MODEL UM06 AND UM08 ELECTROMAGNETIC FLOW METER 150 PSI FLANGED TUBE METER, SIZES 2" thru 48" 300 PSI FLANGED TUBE METER, SIZES 2" thru 48" SPECIFICATIONS WARRANTY: 2 Years ACCURACY TESTS: 5-point wet flow calibration of every complete flow tube with its signal converter. If desired, the tests can be witnessed by the customer. The McCrometer test facilities are traceable to the National Institute of Standards & Technology. Uncertainty relative to flow is ±0.15% ACCURACY: Plus or minus 0.5% of actual flow (battery powered is ±1% of flow) IMPORTANT NOTICE ON FLOW METER ACCURACY: The flow meter, the cable and the electronics are factory calibrated for accuracy as a single unit. Changing the cable length with the Splice Kit changes the accuracy of the meter and invalidates the calibration certificate. REPEATABILITY: ±0.05% or ±.0008ft/s (±0.25mm/s), whichever is greater HEAD LOSS: None. No obstruction in line and no moving parts PRESSURE RANGE: 150 PSI maximum working pressure (UM06); 300 PSI maximum working pressure (UM08) TEMPERATURE RANGE: Sensor Operating: -10 to 60 C (14 to 140 F) Sensor Storage: -15 to 60 C (5 to 140 F) Electronics: Operating and storage temperature: -20 to 60 C (-4 to 140 F) VELOCITY RANGE:.2 to 32 FPS BI-DIRECTIONAL FLOW: Forward and reverse flow indication and forward, reverse, net totalization are standard with all meters CONDUCTIVITY: 5 µs/cm LINER: Liner NSF approved, fusion bonded epoxy ELECTRODES: Type 316 stainless steel, others optional POWER SUPPLY: AC: 100-240VAC/45-66 Hz (20W/25VA), DC: 10-35VDC (21W), battery (four lithium D cell batteries), five-year estimated life, solar (5W panel). AC, DC, battery, or battery & solar must be specified at time of ordering. OUTPUTS: Dual 4-20mA Outputs (Not available for Profibus, HART, or battery converters): Galvanically isolated and fully programmable for zero and full scale (0-22mA). Four separate digital programmable outputs: open collector transistor usable for pulse, frequency, or alarm settings. Volumetric Pulse Flow Rate (Frequency) Directional Indication High/Low Flow Alarms Hardware Alarm Empty Pipe Range Indication SENSOR CABLE LENGTHS: Standard: 25 McCrometer supplied submersible cable with each remote mount unit. Optional: Up to 500 feet, or 50 feet max for battery powered. Quick connect: Available in standard cable lengths: 25, 50, 75, 100, 125, 150, 175, 200, and 500. Custom cable lengths at additional cost. CONVERTER/SENSOR SEPARATION: 500 feet; for longer lengths consult factory EMPTY PIPE SENSING: Zero return when electrodes are uncovered ALARMS: Programmable alarm outputs DIGITAL TOTALIZER: Cubic Meter; Cubic Centimeter; Milliliter; Liter; Cubic Decimeter; Decaliter; Hectoliter; Cubic Inches; US Gallons; Imperial Gallons; Cubic Feet; Kilo Cubic Feet; Standard Barrel; Oil Barrel; US Kilogallon; Ten Thousands of Gallons; Imperial Kilogallon; Acre Feet; Megagallon; Imperial Megagallon; Hundred Cubic Feet, Megaliters IP RATINGS: Metering Tube: NEMA 6P/IP68 with remote converter Die cast aluminum converter: IP67 Panel mount converter: IP65 SENSOR SUBMERSIBILITY DEPTH: With standard strain relief cable: 9 m (30 ft.) With optional quick connect: 1.8 m (6 ft.) CERTIFICATIONS: C US CE Certified (Converter only) Listed by CSA to 61010-1: Certified by CSA to UL 61010-1 and CSA C22.2 No.61010-1-04 ISO 9001:2015 certified quality management system 3255 WEST STETSON AVENUE HEMET, CALIFORNIA 92545 USA TEL: 951-652-6811 800-220-2279 FAX: 951-652-3078 Printed In The U.S.A. Lit. # 30107-09 Rev. 4.8 / 10-23-18 Copyright 2003-2016 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published technical data and instructions are subject to change without notice. Contact your McCrometer representative for current technical data and instructions.

MODEL UM06 AND UM08 ELECTROMAGNETIC FLOW METER Grounding Rings are 0.125" thick. E H I Bracket mounting holes are 0.27" D C Side View B A 2" and 3" Models Body Style End View F G F 9.06" G 5.75" H 5.75" I 6.69" J J 5.44" Converter Dimensions E E C C D A Side View 4" to 12" Models Body Style End View Side View B A End View Grounding Rings are 0.125" thick. 14+" Models Body Style Pipe Size (Nominal) Meter Pipe ID Flow Ranges GPM Standard.2 to 32 FPS Min - Max DIMENSIONS (Lay Lengths) A* B C D E * Laying lengths for meters with ANSI Class 150 Flanges are equal to UM08 laying lengths ** Consult factory Estimated Shipping Weight (lbs.) UM06 UM08 UM06 UM08 UM06 UM08 2" 2.117 2-340 11.00 11.00 6.70 6.00 6.50 7.90 9.26 93 107 3" 3.220 5-730 13.40 13.40 6.70 7.50 8.25 9.40 10.01 97 111 4" 3.720 8-1,140 13.40 13.40 n/a 9.00 10.00 n/a 8.06 78 108 6" 5.692 19-2,660 14.60 14.60 n/a 11.00 12.50 n/a 9.06 82 138 8" 7.692 33-4,870 16.10 17.25 n/a 13.50 15.00 n/a 10.06 115 195 10" 9.682 52-7,670 18.50 18.50 n/a 16.00 17.50 n/a 10.46 144 247 12" 11.682 74-11,180 19.70 19.70 n/a 19.00 20.50 n/a 12.31 193 342 14" 13.440 90-16,070 21.70 22.75 12.00 21.00 23.00 20.30 15.46 321 476 16" 15.440 118-20,900 23.60 25.25 14.20 23.50 25.50 21.10 16.21 390 645 18" 17.440 150-26,480 23.60 25.25 14.20 25.00 28.00 21.10 17.21 446 750 20" 19.440 185-32,720 25.60 28.25 16.20 27.50 30.50 24.80 18.26 588 874 24" 23.440 270-47,180 30.70 35.75 21.70 32.00 36.00 29.60 20.11 769 1,568 30" 29.190 420-73,620 35.80 41.75 26.50 38.75 43.00 35.90 23.26 1,261 2,317 36" 35.190 610-105,930 46.10 46.10 28.20 46.00 50.00 42.70 26.66 1,696 2,915 42" 41.190 830-144,370 48.05 ** 32.10 52.75 ** 48.35 29.99 ** ** 48" 47.190 1,080-188,430 50.00 ** 36.00 59.50 ** 54.00 33.31 ** **

Grounding And Electrical Interference The sensor body must have electrical contact with the media. This is achieved via a grounding ring or grounding button. NOTE: The grounding ring is optional only on 4 through 12 models. For best performance, grounding rings are recommended for all sizes. Always ensure that the converter and the sensor are grounded (earthed) correctly. The grounding of the sensor and converter ensures that the equipment and liquid have an equal potential. For most installations the quality of grounding by the provided cabling assures the sensor is properly grounded and additional grounding of the sensor is not required. However, in instances where this is not the case, i.e. the equipment and fluid do not have an equal potential, such as where the installation location and/or media is subjected to electrical interference, additional grounding steps may be required. Consult an electrician experienced with instrumentation installations to determine if electrical interference is present. For further information on installation environments and sensor grounding, please contact McCrometer Technical Support. Lines With Cathodic Protection: On meters installed on a line with cathodic protection it may be necessary to insulate the meter from the line. Consult your cathodic protection vendor for instructions.

! WARNING: Do not connect any form of conduit directly to the converter enclosure. Doing so will allow moisture and potentially dangerous gasses to enter directly into the converter. Attaching any conduit to the enclosure, or altering the enclosure in any way will void the warranty. Conduit Grounding Bushings Power Cable Enclosure Front Enclosure Backplate Screw Enclosure Back Sensor Cables (Showing 8 Service Loop) Grounding Lead 3.3 Pulling Sensor Cable Through Electrical Conduit IMPORTANT: All cables must have a minimum 8" service loop. Figure 4: Cable Installation, Service Loop And Bonding To Metallic Conduit It is very important to protect the end of the sensor cable when pulling it through a conduit. Water can accumulate in low portions of conduit. Always use the factory supplied cable cover, or similar method, to seal the end of the cable against water when pulling the cable through conduit. See Figure 5. This will ensure proper operation of the meter. Pulling The Sensor Cable: 1. Tie a rope or cable-snake securely around the middle of the cable cover. 2. Carefully pull the rope or snake until the sensor cable end clears the conduit. 3. Bring the cable end to the converter location. If necessary, secure the cable so that it does not fall back through the conduit. 4. Remove the cable cover by pulling the rip wire. The cable cover will tear off (discard the cover). i CAUTION: Do not cut the cable cover off. Doing so may damage the sensor cable and adversely effect the calibration of the meter. Rip Wire Cable Cover Secure rope or snake to this area of the cable cover Sensor Cable Figure 5: Cable Cover

! 4.0 ELECRICAL CABLE CONNECTIONS 4.1 Converter Electrical Cable Connections CAUTION - Always disconnect the power cord before attempting any electrical connections. All electrical cables enter the converter through compression fittings located on the side of the converter. Ensure that all compression glands are properly tightened and all unused fittings are plugged so the case remains sealed. 4.2 Terminal Board All connections are made on the terminal board. To access the terminal board, loosen the four screws on the back of the converter to remove the rear cover. IF2 socket Signaling LED Power Supply Dip switch for block levels enabling NOTE: The terminal blocks unplug from the circuit board for easy connection. EMITTER OUT1 OUT2 OUT3 OUT4 E FORWARD ELECTRODES E1F E2F C SH SH COLLECTORS OUT1 OUT2 OUT3 OUT4 C1 C2 C3 C4 RS485 B A GND SH 1 2 3 4 5 6 7 8 9 10 11 12 13 14! *4-20 ma Out Terminals See Section 4.8 4-20mA Hook Up for complete instructions for connecting the forward and reverse 4-20mA outputs and proper removal of load resistors. 15 16 17 18 19 20 21 22 23 24 25 26 27 28 E2R E1R C SH REVERSE ELECTRODES This terminal block is only used for the 394L bidirectional meter. SH B1 B2 COILS + - INP Figure 6: Terminal Board Descriptions 6 + 24V + + OUT1F* OUT2R* 4-20m SH -24V OUT1 OUT2 4-20mA COMMON

4.6.1 and Mx Body Style 1-2", 3" And 14+" Blue Right Sensing Electrode- 1 (E1F) Pink Left Sensing Electrode- 2 (E2F) Green/Yellow Cable Shield Ground - 4 (SH) Black Reference Ground - 3 (C) Black Ground To Chassis Lug - 4 Green/Yellow Cable Shield Ground - 19 (SH) Yellow Coil - 21 (B2) Red Coil - 20 (B1) i *IMPORTANT: See Section 4.7 Converter Grounding for instructions on attaching the chassis ground wire to the converter ground lug. Cable Terminal Wire Color Connected To A #1 (E1F) Blue Right Sensing electrodes A #2 (E2F) Pink Left Sensing Electrodes A #4 (SH) Green/Yellow Cable Shield Ground B Chassis Lug Black Ground To Chassis Lug* B #20 (B1) Red Coil B #21 (B2) Yellow Coil B #19 (SH) Green Yellow Cable Shield Ground Figure 14: Terminal Block M1 Assignments CABLE A - ELECTRODES CABLE B - COILS Shrink Tube Figure 15: And Mx And Mx Body Style 1 Body - 2, 3 Style and 1 14+ - 2", 3" and 14+" Cable Diameters: And Mx Body Style 1 Sensor Cable Connections Cable Jacket Cable A (15035): 0.248 Cable B (15036): 0.248

4.6.2 and Mx Body Style 2-4" through 12" Blue Right Sensing Electrode- 1 (E1F) Pink Left Sensing Electrode- 2 (E2F) Black Reference Ground - 3 (C) Green/Yellow Cable Shield Ground - 4 (SH) Black Ground To Chassis Lug - 4 Green/Yellow Cable Shield Ground - 19 (SH) Yellow Coil - 21 (B2) Red Coil - 20 (B1) i *IMPORTANT: See Section 4.7 Converter Grounding for instructions on attaching the chassis ground wire to the converter ground lug. Cable Terminal Wire Color Connected To A #1 (E1F) Blue Right Sensing electrodes A #2 (E2F) Pink Left Sensing Electrodes A #3 (C) Black Reference Ground A #4 (SH) Green/Yellow Cable Shield Ground B Chassis Lug Black Ground To Chassis Lug* B #20 (B1) Red Coil B #21 (B2) Yellow Coil B #19 (SH) Green Yellow Cable Shield Ground Figure 17: Terminal Block M1 Assignments CABLE A - ELECTRODES CABLE B - COILS Shrink Tube Cable Jacket Cable Diameters: Cable A (15035): 0.248 Cable B (15036): 0.248 Figure 18: And Mx And Mx Body Style 2-2 Body - 4 - Style 12 2-4" - 12" And Mx Body Style 2 Sensor Cable Connections

4.7 Converter Grounding 4.7.1 Converter Grounding For Multi 394L, 395L, And Or Mx Body Style 2 On converters attached to the 394L, 395L and or the Mx body style 2 flow meters, the sensor cable has a ground wire fitted with a loop. Attach the wire with the loop to the enclosure's ground terminal lug as shown below. in Figure 19. Enclosure Ground Lug Black Ground Wire With Loop From Cable B Coil Cable B Sensing Cable A Figure 19: Converter Grounding With Cable Lug For Multi 394L And 395L, And And Mx Body Style 2

4.7.2 Converter Grounding For or Mx Body Style 1 On converters attached to the or the Mx body style 1 flow meters, the sensor cable has a ground wire fitted with a loop and a terminal extension. Attach the wire to the enclosure's ground terminal lug as shown in below Figure 20 via the wire end loop, then connect the wire extension to Terminal #3. Enclosure Ground Lug Coil Cable B Ground Wire With Loop From Cable B With Lead To Terminal #3 Sensing Cable A Figure 20: Converter Grounding With Cable Lug And Ground Lead For and Mx Body Style 1 4.7.3 Grounding For Panel Mount Converters For panel mount converters, insert the Black Ground wire from Cable B into the Ground terminal in the Power Block as shown in Figure 21. Coil Cable B Figure 21: Panel Mount Converter Grounding Sensing Cable A 13 Cable B Black Ground Wire

4-20mA Hook-Up Isolated 4-20mA current loops are used to output flow data to external devices. Maximum load impedance is 1,000Ω, and the maximum voltage without load is 27VDC. The converter has the capability to detect a loss of load on this output. To disable this function set the value ma Val. Fault under the ALARMS menu to zero (See Section 8.4.6). A graphical example of the usage of the current loop with external device is shown below: + - Terminal 25 OUT1 4-20mA 4-20mA Devices + - NOTE: Remove the jumper from terminals 25 & 27 and/ or 26 & 27 before attaching 4-20mA cables. See Figure 5. Terminal 26 OUT2 4-20mA Terminal 27 OUT 1 OUT2 4-20mA COMMON 4-20mA Hook-Up If the external device requires a voltage input, a precision resistor placed across the input terminals of the external device will change the current to voltage. Calculate the required resistor using Ohm s law (V = I x R). For example, a 250Ω resistor will provide an input voltage of one to five volts with the transmitter range being set from 4mA to 20mA. An additional 4 to 20mA loop output is available. i IMPORTANT The converter powers the 4-20mA loops. Do not use external power for the 4-20mA loop as it may cause permanent damage to the converter.

Opto-Isolated Pulse Output Hook-Up The four outputs are open collector transistor outputs used to communicate with or activate external devices when the flow reaches a predetermined set point. Opto-isolated output with collector and emitter terminals floating and freely connectable Maximum switching voltage: 40 VDC Maximum switching current: 100mA Maximum saturation voltage between collector and emitter 1.2V@100mA Maximum switching frequency (load on the collector or emitter, RL=470Ω, VOUT=24VDC): 1250Hz Maximum reverse current bearable on the input during an accidental polarity reversion (VEC): 100mA Insulation from other secondary circuits: 500 V A common application of outputs should be connected as follows: Examples Of Types Of Input Devices OUTPUTS + - Terminal 6 OUT1 C1 Pulse Input + - Terminal 7 OUT2 C2 Frequency Input + - Terminal 8 OUT3 C3 Alarm Input + - Terminal 9 OUT4 C4 i Alarm Input IMPORTANT Power Source: The power source can be internal or external. + - Terminal 10 EMITTER COMMON Outputs are not isolated from each other. All outputs MUST use the same power source. Opto-Isolated Pulse Output Diagram

! Converter Power Hook-Up WARNING!! Hazardous supply voltage can shock, burn, or cause death. The power supply line must be equipped with external surge protection for current overload (fuse or circuit breaker with limiting capacity not greater than 10A). It must be easily accessible for the operator and clearly identified. Power connection is made using the power terminal block on the upper right side of the terminal board. NOTE: The terminal block uplugs from the circuit board for easy connection. Connect earth ground to the protective grounding terminal before making other connections. The power supply of a standard converter is 90-265VAC, 44-66Hz at maximum 20W. DC converter is available as an option. Neutral Wire Typically A White Wire Line Wire Typically A Black Wire L N Ground Wire Typically A Green Wire AC Power Supply Terminal Block Negative Wire Typically A White Wire Positive Wire Typically A Black Wire + - Ground Wire Typically A Green Wire Optional DC Power Supply Terminal Block

1.3 Parts List With Remote Mount Converter 1 1 2 2 3 6 3 6 4 5 7 7 4 5 Figure 1. 2-3 Model Figure 2. 4-12 Model 1 3 6 2 4 5 7 Figure 3. 14 And Larger Model NO. PART NUMBER DESCRIPTION 1 880003051 AC Converter (Dual 4-20mA Output) 1 880003052 DC Converter (Dual 4-20mA Output) 1 880003054 AC Converter w/ Modbus RS485 Communications Protocol 1 880003055 DC Converter w/ Modbus RS485 Communications Protocol 2 15035 / 15036 Dual Cables - Submersible 3 3-2757- Grounding Wire Assembly 4 3-2781-* Grounding Rings, Stainless Steel (Optional on 4-12 ) 5 1-1557-* Gaskets (Optional) 6 1-1201-10 Nut, Hex, Brass 7 15029 Earth Ground Wire * INSERT METER SIZE TO COMPLETE PART NUMBER - INSERT -02 FOR 2, -04 FOR 4, -06 FOR 6, ETC. -W = 2-16 -14 = 14-20 -24 = 24-30 -36 = 36-48 When ordering replacement parts, please specify: Meter Size Meter Model Meter Serial Number