Product Specification Client: Part No: Product: Feature: SH1W2835(P) SayHi LED Module With Lens 1 pieces 2835 SMD LED. DC12V.160 lens.abs Base. Standard or Pro Client approval Factory Approval Audit Account RightLEDS CO.,LTD Address: 8-12F Complex building Mingjinhai Shiyan Town,Bao'anDistrict,Shenzhen TEL:+86-755 - 2765 6979 FAX:+86-755 - 2765 6780 http://www.rightleds.com Page:1 of 8
1.Features: Good Heat Sink system. Low Brightness Decline. Span Life Up to 50,000hours Finest 2835 LED Package supplier in China to Guarantee High Efficacy ABS Base and Overall Lens Innovative Overmolded Way. Generate Finest China LED Module Double Faced Tape or Screw Hole to Make Installation Easier True 160 view angle True IP65 2.Application: For 6cm Depth of Illuminated Signage. 6000~7000K 9000~11000k 3.Specification: Photoelectric parameters Part No LED color Color temperature Volta ge ( V ) Watt( W ) Lumen ( LM ) Effici ency (LM/ W) View ( ) Day light 6000-7500 34 95 SH1W2835 SMD2835 Cool white 12 0.36 9000~12000 30 85 160 Physical parameters Series Working Cover Weight(g) Span life Size connection Driver environm IP material 20pcs (Years) (mm) (PCS) ent ( ) 12V(cv) 19.5x10x 20 ABS 48 4(5) -25-+70 IP65 12V(cc) 9 Note:1 Test Condition Ta=25±2 ;2CV- constant voltage/cc-constant current 3 The mentioned data are typical. The real data are different from typical data. TEL:+86-755 - 2765 6979 FAX:+86-755 - 2765 6780 http://www.rightleds.com Page:2 of 8
4.Light Diagram and Light Distribution: Light Diagram 5.Dimension(Unit/mm): Light Distribution 6. Best Density Guide LED Sign Stroke 2* ( Multiple Axe to Unifor Depth 1* ( mm) mm) Row Space 3* ( mm) Axe 1* (mm) m Light Rank 5* Surface Min~M Brightness ax Difference 6* (Lux) 8* 7*8* SH1W(P ) 30 30 50 60 Good 10% 2510-2 720 Different Position Surface Brightness Under 30mm Depth Position 1cm 2cm 3cm 4* Min~M ax (cd/m 2 ) 7*8* 909-99 6 cd/m 2 1080 1173 1137 Lux 3030 3160 2950 TEL:+86-755 - 2765 6979 FAX:+86-755 - 2765 6780 http://www.rightleds.com Page:3 of 8
5* Uniform Light Rank Standard 6* Surface Brightness Difference Standard Best The difference of area brightness is less 5% 5% Perfect uniform light. Many lumens are wasted. Better The difference of area brightness is from 5%~8% 5%~8% Excellent uniform light..part lumens are wasted Good The difference of area brightness 8%~10 Good uniform light..no is from 8%~10% % lumens are wasted Ok The difference of area brightness is from 10%~15% 10%~15 % ;feel light shadow on far edge of light but ok. Bad The difference of area brightness is over 15% Above1 5% obviously shadow and spot 7*The test data is recorded under such condition 1 3mm Depth Mitsubishi White Acrylic. Other face materials may vary light uniformity and brightness 2 The all inside are painted with white. Other color may vary TEL:+86-755 - 2765 6979 FAX:+86-755 - 2765 6780 http://www.rightleds.com Page:4 of 8
Right Choice Right LEDs brightness 3 Modules are spaced with wires at not 100% stretch. Left 2cm wires may be needed in corner or turn 4 The color temperature is 6500K 8* The shadow and spot in signs 3mm Depth Mitsubishi White Acrylic (above) Plate 30mm Depth Of Sign 60mm Distance Between Axes 1080 cd/m2 Under 1cm Position 1173 cd/m2 Under 2cm Position 1137 cd/m2 Under 3cm Position TEL +86-755 - 2765 6979 FAX +86-755 - 2765 6780 http //www.rightleds.com Page 5 of 8
7. Connection Layout 8.Installation: Clean & remove all debris from the inside of the signage before you begin Remove tape backing and stick LED modules into place. Potting glass glue on both side of led module or screwing is recommended as security. Use screws, or silicone to secure at least every fifth LED module within the channel letter. TEL:+86-755 - 2765 6979 FAX:+86-755 - 2765 6780 http://www.rightleds.com Page:6 of 8
Connect different lines of led module together. (1)Connect LED strips using in-line connectors ortwist-on wire connectors (2)cut from middle of led modules. Peel off 10mm cover from wire. Connect the red wire (+) of the LED to the red wire (+) of another led strip. Connect the white wire (-) of the LED strip to white wire (-) of the another led strip. Insulate the connections. Test wire connections by hand. It is qualified if you can not pull off by hand. Test wire connections by turn on power supply. Must cap all exposed wires with appropriate wire connectors The connections between led strips and power supply should be covered by silicone or glass glue to prevent from water and rot The Max series connection should ne not over 20 when power supply run only from one side All electrical connections should be made within the Signage. Operate under turn off power Quality of power supply are strongly recommended to make sure the signage lighting last longer TEL:+86-755 - 2765 6979 FAX:+86-755 - 2765 6780 http://www.rightleds.com Page:7 of 8
9.Packing: 2000pcs/carton Carton Size:500*350*315mm Net Weight:18.0(1±10%)kg;Gross Weight:19.(1±10%)kg; The quantity and weight can be different if packing be changed Note 1.Handle them with care 2.Can not be operated in in inflammable and explosive place 3.Operation should be under Turn off power 4. Can not be operated in place near heat source 5.Remove cover should be authorized 6.Any questions about led module. Please feel email us to get professional advice TEL:+86-755 - 2765 6979 FAX:+86-755 - 2765 6780 http://www.rightleds.com Page:8 of 8