STEEMCO Flowmeter for Steam

Similar documents
STEEMCO-MAS Flowmeter for Steam

ORIMAS Mass Flowmeter

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

JUMO flowtrans DP R. Meter run R01 and orifice plate R02. Applications. Brief description. Special features. Customer benefits.

Metal tube variable area flowmeter for gases, liquids and steam

CONSTRUCTION AND DESIGN OF INSTRUMENTS FOR FLOW, LEVEL AND TEMPERATURE. EMCO Liquid Level Switch

EMCO Primary Elements for Flow Measurement

Rosemount 3051CFA Annubar Flowmeter

Multivariable Vortex Flow Meter

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

VIM20 Vortex Insertion Flowmeter

Multivariable Vortex Flow Meter

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

SITRANS F M flow sensors 711/A and 711/911E

Rosemount DP Flowmeters and Primary Elements

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

VersaFlow Vortex 100 Vortex Flow Meter Specifications

F-2600 SERIES INLINE VORTEX FLOW METER

VLM20 In-line Vortex Flowmeter

F-2500 SERIES VORTEX METER

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

VIM20 Vortex Insertion Flowmeter

TRANSMITTER ATTACHES TO THIS SURFACE

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

VIM20 Vortex Insertion Flowmeter

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

RIM20 Rotor Insertion Flowmeter

Armstrong In-Line and Insertion Vortex Flow Meters

Datasheet MATRE Foam Inductors. Datasheet for MATRE Foam Inductors. 1 Contents

SATRON VDt Differential Pressure Transmitter

Transmitting Transducer. Gas/Air Velocity Range:

Product Data Sheet , Rev GA Catalog Content

SATRON VT Pressure Transmitter

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Rosemount 485 Annubar Pak-Lok Assembly

Magnetic-inductive flow meter for hazardous areas

OPTISWIRL 4070 Technical Datasheet

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Vortex Flow Meter Model DVH

94D / 94F / 94M / 96M

OPTISWIRL 4070 Technical Datasheet

Vortex In Line Flow Meter

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Model 8800C Vortex Flowmeter

Pressure transducer DMU 01K Compact version

SATRON VTe pressure transmitter

Electromagnetic Flow Meter Owner s Manual HARDWARE

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

SATRON VVFe Pressure Transmitter

F-2700 SERIES INSERTION VORTEX FLOW METER

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION

F-2600 SERIES INLINE VORTEX FLOW METER

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

Rosemount 405 Compact Orifice Series

Vortex In Line Flow Meter

KDM ARMORED FLOW METER & SWITCH

OPTIMASS 2000 Technical Datasheet

F-1500 SERIES INSERTION TURBINE FLOW METER

OPTIMASS 3000 Technical Datasheet

Rosemount DP Flowmeters and Primary Elements

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

mass flowmeter for compressed air

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

VORTEX IN-LINE FLOW METERS

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

SITRANS P measuring instruments for pressure

Rosemount 3051T In-Line Pressure Transmitter

Food & beverage. Oil & gas. Water & waste water

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

Turbine flowmeters Series TM

Range of Ultrasonic Flowmeters.

Rosemount DP Flowmeters and Primary Elements

Rosemount 8800D Series Vortex Flowmeter

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

Temperature sensor TE2

BM 26 BASIC/ADVANCED Technical Datasheet

Oriflow. Compact Orifice with HART communication. Operating instructions. A-EN RevC Latest Mod von 16

Plastic tube variable area flowmeter for liquids and gases

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

JUMO dtrans p20 DELTA

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

TORRIX Magnetostrictive level sensor

Transcription:

STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical and the power industry. The STEEMCO is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric. The STEEMCO flow meters are backed by international standards covering flow calculation, manufacturing tolerances, accuracy and installation requirements. This type of bare bone technology is world wide accepted and supported by millions of successful installations. Features The STEEMCO flow meter features are: Standardised product based on well proven technology. Compact design. Simple construction. Standardised construction means low inventory. No moving parts. Not sensitive to vibrations. The electronics delivers linear to flow output signal. Digital indicator for local flow reading. High accuracy. Wide rangeability. Easy to install. Easy to re-calibrate. Models with integrated manifold valve 0-03-063-1e 1 of 6

Construction Model ST1 The STEEMCO flow meter model ST1 consists of a primary element based on the differential pressure principle, a condensing pot arrangement, a 3 valve manifold and an electronic differential pressure transmitter with digital signal processing. Model ST2 The STEEMCO flow meter model ST2 consists of a primary element based on the differential pressure principle, an all welded integrated condensing pot arrangement, a 3 valve manifold and an electronic differential pressure transmitter. Model ST3 The STEEMCO flow meter model ST3 consists of a primary element based on the differential pressure principle, an all welded integrated condensing pot arrangement, with transmitter mounting flange, 3 valve double flanged manifold and an electronic differential pressure transmitter ST1 HR without manifold Modular The STEEMCO flow meter is mounted between flanges in sizes from DN 40 (1½") to DN 400 (16") in pressure ratings up to PN 40 (). Accessories Remote electronic indicator with LCD is available for local flow indication and if required check/change of flow rate (differential pressure). ST2 HR integrated manifold All welded Principle of measurement The STEEMCO is a velocity flow meter A restriction in a pipe line changes the value of the different energies. Based on the law of energy balance developed by Bernoulli the sum of energies remains constant. Increases the velocity in the pipe line decreases the pressure in the restriction. The pressure differential between the inlet pressure and the pressure in the restriction is measured expressing the flow velocity. When the physical values of the fluid is known and the inner pipe diameter is established the electronics calculate the flow rate. The flow rate is expressed in an analogue signal 4-20 ma or signal for digital communication. ST3 HR without manifold All welded Horizontal - Right hand side Horizontal - Left hand side Vertical - Downwards Vertical - Upwards 0-03-063-1e 2 of 6

Technical data Sizes : DN 40 - DN 400, 1½" - 16", larger sizes on request Pressure rating : up to PN 40,, higher pressure ratings on request Temperature : Process : up to 400 C, Mounting style : Between flanges according to DIN or ANSI standards Flange facing : flat face (standard), raised face, DIN 2512 N, DIN 2513 R Overall length : 32 mm Material : Stainless steel AISI 316, others on request Design and calculation standards : ISO 5167, ASME MFC-3M. Drain hole : On request β (d/d) : 0,5 and 0,6; other β on request. Accuracy : + /- 1,2 % Rangeability : 8 : 1 Repeatability : better than 0,1 % Pressure loss : typical 150 mbar (values are given at full flow) Reynolds No : Re > 5000 Allowable differential Pressure : max 2,5 bar Output signal : analogue 4-20 ma or Digital communication via protocol, HART, PROFIBUS, Foundation Fieldbus or others. Local indicator : LCD showing flowing units or % (option) Power supply : 14-36 Vdc, typical 24 Vdc. Max load (24 Vdc) : 700 Ohm Enclosure : IP 67 Ex protection : intrinsically safe EEx ia IIC T6 Explosion proof EEx d IIC T6 Temperature : Ambient : -40 - +80 C 0-03-063-1e 3 of 6

Sizes DIN flanges Size Pipe Pressure ß = 0,5 ß = 0,6 Inner pipe diameter OD rating Bore Bore B A1 A2 DN 40 48,3 PN 40 43,1 21,5 26,0 90 147 157 DN 50 60,3 PN 40 54,5 27,3 32,0 107 156 166 DN 65 76,1 PN 40 70,3 35,0 42,0 127 166 176 DN 80 88,9 PN 40 82,5 41,0 49,5 142 173 183 DN 100 114,3 PN 16 107,1 54,0 64,0 162 183 193 DN 100 114,3 PN 40 107,1 54,0 64,0 168 186 196 DN 125 139,7 PN 16 131,7 66,0 79,0 192 198 208 DN 125 139,7 PN 40 131,7 66,0 79,0 194 199 209 DN 150 168,3 PN 16 159,3 80,0 96,0 218 211 221 DN 150 168,3 PN 40 159,3 80,0 96,0 224 214 224 DN 200 219,1 PN 16 207,3 104,0 124,4 273 239 249 DN 200 219,1 PN 25 206,5 104,0 124,4 284 244 254 DN 200 219,1 PN 40 206,5 104,0 124,4 290 247 257 DN 250 273 PN 16 260,4 130,0 156,0 329 267 277 DN 250 273 PN 25 258,8 130,0 156,0 340 272 282 DN 250 273 PN 40 258,8 130,0 156,0 352 278 288 DN 300 323,9 PN 10 309,7 155,0 185,0 378 291 301 DN 300 323,9 PN 16 309,7 155,0 185,0 384 294 304 DN 300 323,9 PN 25 307,9 155,0 185,0 400 302 312 DN 300 323,9 PN 40 307,9 155,0 185,0 417 311 321 DN 350 355,6 PN 10 341,4 170,0 204,0 438 321 331 DN 350 355,6 PN 16 339,6 170,0 204,0 444 324 334 DN 350 355,6 PN 25 339,6 170,0 204,0 457 331 341 DN 350 355,6 PN 40 338,0 170,0 204,0 474 339 349 DN 400 406,4 PN 10 392,2 195,0 234,0 489 341 351 DN 400 406,4 PN 16 390,4 195,0 234,0 495 350 360 DN 400 406,4 PN 25 388,8 195,0 234,0 514 359 369 DN 400 406,4 PN 40 384,4 195,0 234,0 546 375 385 ANSI flanges Size Pipe OD 1½" 48,3 2" 60,3 3" 88,9 4" 114,3 6" 168,3 8" 219,1 10" 273 12" 323,9 14" 355,6 16" 406,4 Sch. 10S Sch. 40 Sch. 80 Pressure ß = 0,5 ß = 0,6 rating Inner pipe Inner pipe Inner pipe B A1 A2 Bore Bore dia. dia. dia. 150 lbs 85,7 145 268 42,7 40,9 37,3 20,0 24,0 95,3 150 273 150 lbs 104,8 154 277 54,7 52,5 49,3 26,0 31,5 111,1 158 281 150 lbs 136,5 170 293 82,8 77,9 73,7 39,0 47,0 149,1 177 300 150 lbs 174,6 189 312 108,2 102,3 97,2 51,0 61,0 181,1 193 316 150 lbs 222,3 213 336 161,5 154,1 146,3 77,0 92,5 250,7 227 350 150 lbs 279,4 242 365 211,5 202,7 193,7 101,0 121,6 308 256 379 150 lbs 339,7 272 395 264,6 254,5 242,8 127,0 153,0 362 283 406 150 lbs 409,6 307 430 314,7 303,2 289,1 150,0 180,0 422,3 313 436 150 lbs 450,9 327 450 346 333,3 317,5 165,0 198,0 485,8 345 468 150 lbs 514,4 359 482 396,8 381 363,6 190,0 228,0 539,8 372 495 0-03-063-1e 4 of 6

Overall dimensions Installation requirements The STEEMCO flow meter can be mounted in a horizontal or vertical pipe. The condensing pot arrangement shall be mounted horizontally with the outlet pointing downwards. To insure high accuracy of measurement, long straight pipe runs upstream from the flow meter is necessary. The required straight pipe run depends on the disturbance upstream. To maintain the 1,2% accuracy the minimum straight pipe run upstream shall be 14 x inner pipe diameter and 6 x downstream If an additional inaccuracy of ½ % is acceptable the required straight pipe runs are reduced to half of the above values. Mass flow Mass flow measurement of saturated steam is obtainable using STEEMCO with a multi variable differential pressure transmitter. Mass flow measurement of super heated steam : ask for STEEMCO-MAS mass flow meter data sheet. 0-03-063-1e 5 of 6

STEEMCO coding 1. Type 2. Size In AISI 316 with transmitter flange code ST1 integrated manifold code ST2 integrated cond. chamber code ST3 DN 40, DIN standard code 040 DN 50, DIN standard code 050 DN 65, DIN standard code 065 DN 80, DIN standard code 080 DN 100, DIN standard code 100 DN 125, DIN standard code 125 DN 150, DIN standard code 150 DN 200, DIN standard code 200 DN 250, DIN standard code 250 DN 300, DIN standard code 300 DN 350, DIN standard code 350 DN 400, DIN standard code 400 1½, ANSI standard code 01.5 2, ANSI standard code 002 3, ANSI standard code 003 4, ANSI standard code 004 6, ANSI standard code 006 8, ANSI standard code 008 10, ANSI standard code 010 12, ANSI standard code 012 14, ANSI standard code 014 16, ANSI standard code 016 3. Pressure rating PN 10, DIN standard code 10 PN 16, DIN standard code 16 PN 25, DIN standard code 25 PN 40, DIN standard code 40 150 lbs, ANSI standard code 15, ANSI standard code 30 4. Facing DIN 2526 Form A code 26 DIN 2513 Form R13 code 13 DIN 2512 Form N code 12 Raised face RF, ANSI std. code RF Flat face FF, ANSI std. code FF 5. Pipe schedule ( only applicable for ANSI flanges) DIN flanges code 00 Schedule 10S code 10 Schedule 40 code 40 Schedule 80 code 80 6. β value β value 0,5 code 5 β value 0,6 code 6 β value free choice code 9 7. Drain/vent hole Ø3 mm Without drain/vent hole code 0 With drain/vent hole code 1 8. Manifold valve ST1 - Without code 0 ST1-3 valve manifold code 1 ST2 - Integrated manifold code 2 ST3 - Integrated condensing chamber without manifold code 3 ST3 - Integrated condensing chamber with manifold code 4 9. Mounting position Horizontal pipe right hand code HR Horizontal pipe left hand code HL Vertical pipe down code VD Vertical pipe up code VU 10. Differential pressure transmitter Without code 0 Included code Original transmitter type no. Examples DN 100 STEEMCO ST1 in stainless steel PN 40 with DIN 2526 facing, β value 0,6, with drain hole, for horizontal right hand mounting and 3 valve double flanged manifold valve type G3H and without transmitter has following code: ST1-100-40-26-00-6-1-1-HR-0 8 STEEMCO ST2 in stainless steel 150 lbs with RF facing, β value 0,5, without drain hole, with Integrated manifold, for vertical mounting flow direction downwards has following code: ST2-008-15-RF-40-5-0-2-VD-0 0-03-063-1e 6 of 6