Dawson DSM170 Multi-Function Moisture Meter User s Manual

Similar documents
Dawson DDM190D. Digital Multimeter User s Manual

Dawson DAN100. Analog Multimeter User s Manual

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

362 Clamp Meter. Users Manual

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

365 Detachable Jaw True-rms Clamp Meter

TMD90A Dual Input Digital Thermometer

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

373 Clamp Meter. Users Manual

Visit us at

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

WENS30C Loop Calibrator

TIME-10 Process Control Stopwatch

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

4-20mA DC PROCESS CLAMP METER

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free


The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

ELECTRICAL. Moisture Meter User Guide

Phase Sequence Tester

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

323/324/325 Clamp Meter

362 Clamp Meter. Users Manual

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

Tracer ORP PockeTester TM Code 1742

i3000s/i2000 Flex AC Current Probe

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

5.2 PRE-OPERATION PROCEDURE WARRANTY

OPERATING INSTRUCTIONS. TempCheck Non-Contact Infrared Thermometer IRT200 F C + -

PH20 Value ph Tester Instruction Manual

ORPscan20 Pocket ORP Tester Instruction Manual

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

This manual covers the following model:

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

BIM-17-2 Bus Interface Module for compass and outside temperature

PHscan10S Pocket ph Tester Instruction Manual

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

PHscan30S Pocket ph Meter Instruction Manual

EC20 Pocket Conductivity Tester Instruction Manual

Salt 1 Pocket Salinity Tester Instruction Manual

EC1 Pocket Conductivity Tester Instruction Manual

OPERATING INSTRUCTIONS

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Model UT602/603: OPERATING MANUAL

Garden Thermometer with Solar Lighting

BC-9000 OPERATIONS MANUAL BATTERY CHARGER COFKO ELECTRONICS LLC COPYRIGHT 2014 P/N

OPERATING INSTRUCTIONS

TDSscan10M Pocket TDS Tester Instruction Manual

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

PY-11 Voltage & Continuity Tester

Calibration Manual. Detachable Jaw True-rms Clamp Meter

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

716 Pressure Calibrator

PLATINUM PCT101 PRECISION POCKET CARAT SCALE

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Delmhorst Instrument Co. Model HT-3000 Thermo-Hygrometer. Owners Manual

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

THWD-3 and TH-3 Relative Humidity and Temperature Meters

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

707Ex. Users Manual. ma Calibrator

Universal 8-Bay Charger. for AA/AAA/C/D/9 NiMH & NiCd Rechargeable Batteries. Owner's Manual

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

Marin Control Digital

Temperature Calibrator

302+/303 Clamp Meter. Users Manual

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

Model UT601: OPERATING MANUAL

ECscan20 Pocket Conductivity Tester Instruction Manual

J-Lite. o w n e r s m a n u a l W H E N A C C U R A C Y I S T H E P O I N T

TABLE OF CONTENTS 11.0 WARRANTY

User's Guide. CO 2 Meter. Model CO250

Coating Thickness Gauges

INSP-3 Wiring Inspection Tester

User Manual Pocket Pro, Pro + ph

CONTENTS. Introduction. Thank you for purchasing the AlcoSense Precision+ breathalyser.

Owner s Guide CA 4555

Operating Manual COST CONTROL - POWER CONSUMPTION MONITOR

TACH-10 Contact / Non-Contact Tachometer

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

SLA Battery Capacity Analyzer

OPERATING INSTRUCTION

OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200

712 RTD Calibrator. Instruction Sheet. Introduction

Breath Alcohol Tester

SPC Series. Digital Scale. Operation Manual

PTC8001 Temperature Calibrator

i400s Calibration Information Introduction

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

TABLE OF CONTENTS NOTES. 1.0 Operating principle... 02

flexible infrared thermometer

Transcription:

Dawson DSM170 Multi-Function Moisture Meter User s Manual

Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 3 Safety Information... 4 INTRODUCTION... 6 Overview... 6 Figures And Components... 7 LCD Display Panel... 8 USING THE METER... 9 Power On/Off... 9 Choosing Materials... 10 Measure/Hold... 10 MAX/MIN Display... 10 Switching between Functions... 11 Backlight Dispaly... 11 Others... 11 TECHNICAL SPECIFICATION... 12

Measurement Specification... 12 MAINTENANCE AND REPAIR... 13 Repair... 13 Replacing Batteries... 14 Calibration... 14 CONTACT DAWSON... 14 FEATURES... Back Page

LIMITED WARRANTY AND LIMITATION OF LIABILITY This instrument from Dawson Tools Inc. will be free from defects in workmanship and material for three years from the date of original purchase. This warranty does not cover defects resulting from damage caused by the user such as drops, neglect, misuse, unauthorized alteration, usage outside of specified conditions, contamination, or improper repair/maintenance. To receive service on the instrument if it becomes necessary during the warranty period, contact your nearest Dawson authorized service center at (800) 898-6991 or visit www.dawsontools.com to obtain a return authorization (within the US only). A return authorization is necessary before returning any instrument to Dawson; no service will be provided without a return authorization. The user is responsible for properly packing the unit and charges such as shipping, freight and insurance charges. The extent of Dawson's liability is limited solely to the repair/replacement of the instrument. The above warranty in its entirety is inclusive and no other warranties, written or oral, are expressed or implied. Out of the Box Check the Meter and accessories thoroughly before using the Meter. Contact your local distributor if the Meter or any components are damaged or malfunction. Accessories User s Manual AAA Batteries x2 Case

Safety Information WARNING TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, PRODUCT DAMAGE OR PERSONAL INJURY, PLEASE FOLLOW THE SAFETY INSTRUCTIONS DESCRIBED IN THE USER MANUAL. READ THE USER MANUAL BEFORE USING THE METER. WARNING TO ENSURE SAFE OPERATION AND LIFE OF THE METER, DO NOT PLACE THE METER IN ANY ENVIRONMENT WITH HIGH PRESSURE, HIGH TEMPERATURE, DUST, EXPLOSIVE GAS OR VAPOR. Safety Symbols Important safety message Conforms to relevant European Union directives

Warning Symbols Warning Caution Risk of danger. Important information. See Users Manual Statement identifies conditions and actions that failure to follow the instructions could result false readings, damage the Meter or the equipment under test. WARNING TO AVOID ELECTRICAL SHOCK AND INJURY, COVER THE METER WITH PROTECTIVE COVER WHEN NOT IN USE. Caution To avoid possible electric shock or personal injury: Use the Meter only as specified in this manual or the protection provided by the Meter might be impaired. Do not place the Meter near explosive gases or vapor. Read the User s Manual before use and follow all safety instructions. Operate the Meter between 14~122 F (-10~50 C). Avoid shaking, dropping or any kind of impacts when using or transporting the Meter.

To avoid electric shock or personal injury, repairs or servicing not covered in this manual should be performed only by qualified personnel. Check the terminals every time before operating the Meter. Do not operate the Meter if the terminals are damaged or one or more functions are not working properly. Avoid exposing the Meter to direct sunlight to ensure and extend the life of the Meter. Do not place the Meter in a strong magnetic field, it may cause false readings. Use only the batteries indicated in the Technical Spec. Avoid exposing the battery to humidity. Replace the batteries as soon as the low battery indicator appears. Sensitivity of the Meter to temperature and humidity will be lower over time. Please calibrate the Meter periodically for best performance Please keep the original packing for future shipping purposes (ex. Calibration) Introduction Overview DSM170 is a material moisture, temperature, humidity all-in-one multi functions Meter. The Meter is ideal for measuring moisture of wood and concrete buildings.

Figures and Components (1) Terminal Protective Cover. (2) LCD Display (3) On/Off Button: Press once to turn the Meter on, hold for 1 sec to turn it off. (4) Temperature/Moisture Unit Settings: Temp: C/ F Moisture:%/WB/TD The Meter will exit unit switching mode if Enter button is not pressed after 8 sec. (5) Backlight Button (6) Display Hold Button (7) Switch between testing materials (8) Maximum/Minimum Display Button (9) Enter Button. DSM170 Diagram

LCD Display Panel 1 Current Temperature 2 Temperature Unit 3 Current Moisture 4 Moisture Unit 5 Material 6 Material Label 7 Maximum/Minimum 8 Moisture Readings Display 9 Moisture Unit 10 Simulated Moisture Bar 11 Measure/Hold 12 Low Battery Indicator DSM170 LCD Display

Using the Meter Power On/Off Press On/Off button to turn on the Meter. The Meter will display as in Figure 2-1-1 and show the current temperature and humidity. When the Meter is on, hold On/Off button for 1 sec. to turn off the Meter. The Meter will automatically turn off if it is not in operation for 10 minutes. Figure 2-1-1

Choosing Materials Press Material button to choose from materials 1 to 7 and repeat. Choose proper number correspondingly as follow: 1: Beech, Spruce, Larch, Birch, Cherry, Walnut 2: Oak, Cedar, Maple, Ash Tree, Citigroup, Tamarisk 3: Smoothing Cement, Concrete 4: Anhydrite Screed 5: Cement Mortar 6: Lime Mortar, Plaster 7: Brick Measure/Hold To hold the readings, press Hold button and Hold will be displayed on the top right corner. To cancel hold, press Hold button again, the Meter will now show current readings. Maximum/Minimum To show the maximum moisture reading, press MAX/MIN button till MAX is displayed. To show the minimum moisture readings, press MAX/MIN button till MIN is displayed. To show current moisture readings, press MAX/MIN button till the LCD does not display MAX nor MIN In MAX or MIN mode, if the MAX/MIN button is not pressed for 5 minutes, the Meter will switch back to current moisture readings.

Switch between Functions Press Unit button to switch between functions % WB and TD (Symbols flash). Press the Enter button to confirm selection. If no selection is confirmed within 8 seconds, the Meter will exit switching mode. Backlight Display Press the backlight button to turn on the backlight, press again to turn it off. The backlight will turn off if itself when turn of the Meter. Others If the LCD display is dim or does not display clearly, replace batteries. To ensure accurate readings, measure multiple locations with the Meter. To measure woods, stick the Probe in the wood and wait for at least 5 seconds to obtain stable readings. Keep the Meter away from any heat source or possible temperature disturbance (ex. Hand).

Technical Specification Measurement Specification Electric Conductivity (Resistance Sensor) Range: 0.0~60.0%; Temperature (Temperature Sensor) Range: 14.0~122.0 F (-10.0~50.0 C) Units: Material Moisture: % Environment Humidity: %, WB, TD Environment Temperature: C, F Materials Moisture Range: Material 1: Beech, Spruce, Larch, Birch, Cherry, Walnut 8.5~60.0% Material 2: Oak, Cedar, Maple, Ash Tree, Citigroup, Tamarisk 6.8~53.4% Material 3: Smoothing Cement, Concrete 0.9~24.5% Material 4: Anhydrite Screed 0.0~12.2% Material 5: Cement Mortar 0.7~9.2% Material 6: Lime Mortar, Plaster 0.5~11.1% Material 7: Brick 0.0~17.8% Resolution: Material Moisture:0.1% Temperature : 0.1 C, 0.1 F Humidity: 0.1% Accuracy (performed under temperature of 77 C) : Conductivity:±2%

Temperature:±3.5 F (14.0~122.0 F) Humidity:±5 % (10~90%) Sample Interval: Material Moisture Sample Speed:240ms ; LCD refresh time: 1.5s Temperature Sample Speed:240ms ; LCD refresh time 1.5s Humidity Sample Speed:240ms ; LCD refresh time 3.5s Operation Temperature:14~122 F (-10~50 C) Storage Temperature:-40~140 F (-40~60 C) Batteries: 2 1.5V AAA Battery Life: 200 hrs. (w/backlight off) Size: 130 55 29mm Weight:4.9oz (140g) with batteries and protective cover Maintenance and Repair Repair Please follow these steps closely if the Meter is not functioning properly: Check batteries; replace with new batteries if low battery indicator appears. Follow User s Manual to confirm all procedures. Before sending Meter back for repair, include a description of the problems encountered. Remove batteries and pack Meter well to avoid damage in delivery, Dawson does not cover damage due to delivery. Repair or service not covered in this manual should be performed only by the authorized service center or qualified personnel.

Replacing Batteries Follow these steps to replace batteries: Turn off the Meter. Loosen the battery compartment door and remove the door from the case bottom. Remove batteries and replace with new batteries. Re-attach the battery compartment door to the case bottom and tighten screw. Calibration To ensure the accuracy of the Meter, Scheduled calibration is recommended and should be performed only by qualified personnel. Calibrating the Meter annually is recommended. Calibration frequency can be higher or lower depending of the frequency of usage. Contact Dawson Dawson Tools, Inc. 1142 S. Diamond Bar Blvd., #858 Diamond Bar, CA 91765 Phone: (310) 728-6220 www.dawsontools.com Do not recycle

(Back Page) Features LCD Display MAX/MIN Display Back Light Data Hold Low Battery Indicator