Model Number Structure

Similar documents
Model Number Structure

Model Number Structure

G3PE-Single-phase. Solid State Relays for Heaters

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Model Number Structure

A165E CSM_A165E_DS_E_11_2

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

D4BS CSM_D4BS_DS_E_8_4

D4GS-N CSM_D4GS-N_DS_E_7_2

S8JX-N/S8JX-G Series Replacement Brackets

Solid State Relays G3NA. Model Number Structure. Model Number Legend

DIN Track Terminal Blocks with Screw Terminals XW5T

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

2NC (slow-action) Direct. Model. opening

DIN Track Terminal Blocks with Screw Terminals XW5T

DIN Track Terminal Blocks with Screw Terminals

Better Productivity by Standstill and Low-speed Monitoring

G3NA. Model Number Structure. Solid State Relays. Model Number Legend

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

Dimension A. Dimension B

Solid State Relays for Heaters

A22LK CSM_A22LK_DS_E_6_2

High-power Solid State Relays G3PH

D4BL. Guard Lock Safety-door Switch

Model Number Structure

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Digital display Pressure range ON/OFF output Linear output Model

High-power Solid State Relays G3PH

D4NH CSM_D4NH_DS_E_7_1

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

2NC (slow-action) Direct. Model. opening

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

CSM_D4N-_R_DS_E_6_1

A22E. Emergency Stop Switch (22-dia./25-dia.) Install in 22-dia. or 25-dia. Panel Cutout. Model Number Structure L M 24A 01

Solid State Relays for Heaters

Ordering Information. Solid State Relay G3NA. New Models with 75-A and 90-A Output Join the Previous Models with 5- to 50-A Output.

Multiple Limit Switch

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Redundancy Unit. Model Number Structure. Ordering Information. Model Number Legend. New Product. S8VK-R Series name

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

G3PE-Single-phase. Solid State Relays for Heaters

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

Power Controller. (see note 1) 10 sec

A4EG CSM_A4EG_DS_E_6_1

A3S. Pushbutton Switch Series with Square 40-mm Body. Lighted Pushbutton Switch (Square) List of Models

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

D4NS/D4NS-SK. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Nextgeneration. Model Number Structure. Model Number Legend

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

Pushbutton Switches 30-mm Pushbutton Switches Universal Design. Emphasis on Color Coding, Workability, and Safety.

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

D4BL. Guard Lock Safety-door Switch

Smile 11 RA/-B Smile 12 RF/-G Reset button

Small-diameter Proximity Sensor

Safety Limit Switch

Solid State Relays for Heaters G3PJ

Tina 11A Connection block

Tina 4A Connection block

Power ratings Input voltage Output Voltage Output current Boost Current Model number 120 W 2-phase and 3-phase

Slim Relay G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Switching Power Supply

Model Number Structure. Characteristics. Model Number Legend. Soft Starter. Applicable Motors. Accessories

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Model Number Structure

Sense7-series Non-contact coded safety switch

Safety Guard Switching Unit G9SX-GS

Solid State Relays for Heaters G3PJ

Smile 41 Push-button box with/without emergency stop

Switching Power Supply

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

PRODUCT SPECIFICATION 28&29. Solid State Relays. Series.

Tina 10A/B/C Adaptor unit

Miniature Limit Switches

FMC-1/2 Tina Muting unit

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Safety-door Switch. Ordering Information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

D4NL CSM_D4NL_DS_E_9_2

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Switch Mode Power Supply S8VS

A22. Install in 22-dia. or 25-dia. Panel Cutout (When Using a Ring) Pushbutton Switch (Cylindrical 22/25-dia.) List of Models

EStrong-series Emergency Stop

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Ordering Information. Motor Time Switch H2F-D. Accessories (Order Separately) ON/OFF Control 48 Times per Day in 15-min Increments

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

1,000 M min. (at 500 VDC)

Transcription:

Solid State Relays CSM OEE_DS_E_1_2 Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via screws or via DIN track. Close mounting possible for linking terminals. (Except for - 260B-VD and -450B-VD-2.) Applicable with 3-phase loads. Replaceable power element cartridges. Comply with VDE 0160 (finger protection), with a dielectric strength of 4,000 V between input and load. Certified by UL, CSA, and VDE (reinforced insulation). Refer to Safety Precautions for All Solid State Relays. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Model Number Legend -@@@@-@-@ 1 2 3 4 5 6 7 1. Basic Model Name : Solid State Relay 2. Rated Load Power Supply Voltage 2: 0 VAC 4: 400 VAC 3. Rated Load Current : A 30: 30 A 40: 40 A 50: 50 A 60: 60 A 4. Terminal Type B: Screw terminals 5. Zero Cross Function Blank: Equipped with zero cross function 6. Certification VD: Certified by UL, CSA, and VDE 7. Special Specifications Blank: Standard models 2: 480-V models 1

Ordering Information List of Models Model Isolation Zero cross function Indicator Rated output load Rated input voltage -240B-VD Phototriac Yes Yes 40 A at 24 to 240 VAC 5 to 24 VDC -260B-VD coupler 60 A at 24 to 240 VAC -4B-VD A at 0 to 400 VAC 12 to 24 VDC -430B-VD 30 A at 0 to 400 VAC -4B-VD-2 A at 0 to 480 VAC -430B-VD-2 30 A at 0 to 480 VAC -450B-VD-2 50 A at 0 to 480 VAC Note: When ordering, specify the rated input voltage. Replacement Parts Name Carry current Load voltage range Model Applicable SSR VDE certification Power Device 40 A 19 to 264 VAC G32A-A40-VD DC5-24 -240B-VD DC5-24 Yes Cartridge 60 A G32A-A60-VD DC5-24 -260B-VD DC5-24 A 180 to 440 VAC G32A-A4-VD DC12-24 -4B-VD DC12-24 30 A G32A-A430-VD DC12-24 -430B-VD DC12-24 A 180 to 528 VAC G32A-A4-VD-2 DC12-24 -4B-VD-2 DC12-24 30 A G32A-A430-VD-2 DC12-24 -430B-VD-2 DC12-24 50 A G32A-A450-VD-2 DC12-24 -450B-VD-2 DC12-24 2

Specifications Ratings (at an Ambient Temperature of 25 C) Input Model Rated voltage Operating Voltage Input current Voltage level range impedance Must operate voltage Must release voltage -240B-VD 5 to 24 VDC 4 to 30 VDC 7 ma max. 4 VDC max. 1 VDC min. -260B-VD -4B-VD 12 to 24 VDC 9.6 to 30 VDC 7 ma max. 9.2 VDC max. 1 VDC min. -430B-VD -4B-VD-2-430B-VD-2-450B-VD-2 Output Model Rated load voltage Load voltage range Load current Inrush current VDRM (reference value) -240B-VD 24 to 240 VAC (50/60 Hz) 19 to 264 VAC (50/60 Hz) 0.5 to 40 A at 40 C 440 A (60 Hz, 1 cycle) 600 V (VDRM) -260B-VD 0.5 to 60 A at 40 C 440 A (60 Hz, 1 cycle) -4B-VD 0 to 400 VAC (50/60 Hz) 180 to 440 VAC (50/60 Hz) 0.5 to A at 30 C 2 A (60 Hz, 1 cycle) 1,000 V (VDRM) -430B-VD 0.5 to 30 A at 30 C 440 A (60 Hz, 1 cycle) -4B-VD-2 0 to 480 VAC (50/60 Hz) 180 to 528 VAC (50/60 Hz) 0.5 to A at 30 C 2 A (60 Hz, 1 cycle) 1,0 V (VDRM) -430B-VD-2 0.5 to 30 A at 30 C 440 A (60 Hz, 1 cycle) -450B-VD-2 0.5 to 50 A at 30 C 440 A (60 Hz, 1 cycle) Refer to Engineering Data for further details. 3

Characteristics Item - 240B-VD - 260B-VD - 4B-VD - 4B-VD-2 Operate time 1/2 of load power source cycle + 1 ms max. (DC Input, -B models) 1 1/2 of load power source cycle + 1 ms max. (AC Input) 1 ms max. (-BL models) Release time 1/2 of load power source cycle + 1 ms max. (DC Input) 1 1/2 of load power source cycle + 1 ms max. (AC Input) Output ON voltage drop 1.6 V (RMS) max. 1.8 V (RMS) max. Leakage current 10 ma max. (at 100 VAC) ma max. (at 0 VAC) ma max. (at 400 VAC) ma max. (at 480 VAC) - 430B-VD ma max. (at 400 VAC) - 430B-VD-2 ma max. (at 480 VAC) - 450B-VD-2 I 2 t 1,260 A 2 s 260 A 2 s 1,800 A 2 s 1,800 A 2 s 1,800 A 2 s Insulation 100 MΩ min. (at 500 VDC) resistance Dielectric strength 4,000 VAC, 50/60 Hz for 1 min Vibration Destruction: 10 to 55 to 10 Hz, 0.375 mm single amplitude (Mounted to DIN track) resistance Shock Destruction: 300 m/s 2 (mounted to DIN track) resistance Ambient temperature Certified standards EMC Ambient humidity Weight Operating: 30 C to 80 C (with no icing or condensation) Storage: 30 C to 100 C (with no icing or condensation) UL508, CSA C22.2 (No.14, No.950), EN60950-1 File No. 5915ÜG Emission: EN55011 Group 1 Class A Immunity: EN61000-6-2 Operating: 45% to 85% Approx. 460 g Approx. 900 g UL508, CSA C22.2 (No.14), EN60947-4-3 File No. 6642ÜG Approx. 290 g UL508, CSA C22.2 (No.14), EN60947-4-3 File No. 133127ÜG Approx. 290 g UL508, CSA C22.2 (No.14), EN60947-4-3 File No. 6642ÜG Approx. 410 g UL508, CSA C22.2 (No.14), EN60947-4-3 File No. 133127ÜG Approx. 410 g Approx. 900 g 4

Operation Replacement Parts G32A-A Power Device Cartridge The G32A-A Power Device Cartridge (a Triac Unit) can be replaced with a new one. When the temperature indicator has changed from pink to red, the triac circuitry may have malfunctioned possibly by an excessive flow of current, in which case, dismount the damaged cartridge for replacement. The damaged cartridge can be replaced with a new one without disconnecting the wires from the. Improve the heat radiation efficiency of the before replacing the cartridge. The G32A-A Power Device Cartridge can withstand an excessive current for a short period of time, such as may be caused accidentally by the short circuitry of the load, in which case the temperature indicator will not turn red. Be sure to turn OFF the power supply when replacing the Cartridge. Supplying power with the Cartridge removed may result in malfunction. To remove or replace the Power Device Cartridge for the -4B-VD(-2), use the special tool provided with it for extraction. (No special tool is required for other models.) The can be broadly divided into two series: Previous models and models with model numbers that end with "-VD." The Cartridge shown at the right cannot be mounted to models in the -@@@B-(-US) Series. Appearance G32A-A40-VD G32A-A60-VD G32A-A4-VD(-2) G32A-A430-VD(-2) G32A-A450-VD-2 Replacing Power Device Cartridges When replacing Power Device Cartridges, use the specified model. Using a Power Device Cartridge other than the specified one will result in faulty operation and destruction of the elements. 5

Replacement Procedure G32A-A4-VD(-2) To remove or replace the Power Device Cartridge, use the special tool provided with it for extraction. (Do not switch on the power without the Power Device Cartridge. For details, see the attached the instruction sheet with the product.) Extraction Follow the procedures below to dismount the Power Device Cartridge from the. 1. Switch off the power. 2. Remove the terminal cover. 3. Hook the indented part of the cartridge with the tool and pull up on the cartridge to remove it. Hook here with Remover. Remover 2. Make sure that there is no dust or pieces of wire on the heat sink of the G32A-A or the. 3. Insert the cartridge into the opening of the so that the letters on the cartridge and those on the are in the same direction and side A and side B are even. Side A Apply silicone grease here. Side B Mounting Follow the procedures below to mount the Power Device Cartridge on the. 1. Apply silicone grease (provided with the G32A-A) to the entire surface of the heat sink. 4. Attach the terminal cover. 5. Switch on the power and check the to be sure it works properly. G32A-A40-VD/G32A-A60-VD/G32A-A430-VD(-2)/G32A-A450-VD-2 The G32A Power Device Cartridge is mounted and secured with screws to the Unit. No special tool is required to remove the Cartridge. Extraction Follow the procedures below to dismount the G32A-A Power Device Cartridge from the. 1. Switch off the power. 2. Remove the terminal cover. 3. Loosen the two centered screws on the sides to dismount the cartridge. The screws are connected to terminals 1 and 2. Mounting 1. Apply silicone grease to the entire surface of the heat sink. Loosen Apply silicone grease here. 2. Make sure that there is no dust or pieces of wire on the heat sink of the G32A-A or the. Loosen 4. Loosen the screws on both the corners. Loosen Loosen 5. Hold the indented part of both the corners to dismount the cartridge. 6

3. Insert the cartridge into the opening of the so that side A and side B are even. Side A 4. Tighten the screws on both the corners with a tightening torque of 0.59 to 0.78 N m. 5. Tighten the screws on both the sides with a tightening torque of 0.59 to 0.78 N m. 6. Attach the terminal cover. 7. Switch on the power and check the to be sure it works properly. Side B Linking Terminal Connection Connecting with linking terminal for -240B-VD and -4B-VD(-2), -430B-VD(-2). SSR1 SSR2 SSR1 SSR2 Connecting with linking terminal for G32A. SSR G32A Unit SSR G32A Unit * 1. When SSRs are close mounted, loosen the M3.5 Sems screw and flip the linking terminal down. 2. Insert the linking terminal securely into the center of the screw and tighten the screw. 1. When SSR are close mounted, loosen the M3.5 Sems screw on the G32A and flip the linking terminal down. * The cover will not fit if the terminal protrudes. 2. Insert the linking terminal securely into the center of the screw and tighten the screw. Ensure that the linking terminal does not protrude. Connect the terminal with power off. Linking terminal Refer to the instruction manual for the G32A-A Power Device Cartridge to replace the 's triac part. Linking terminal -4B-VD Linking terminal Linking terminal When the temperature indicator has turned from pink to red, the G32-A-A Power Device Cartridge may have malfunctioned, in which case the cartridge must be replaced with a new one. Use the terminal cover to prevent accidents due to electric shock. 7

Engineering Data Load Current vs. Ambient Temperature Vertical Mounting Panel Ground -240B-VD -260B-VD 80 60 40 25-30 - 0 40 60 80 100 For close mounting of two or three SSRs, limit the load current to 90% or less. -4B-VD, -4B-VD-2-430B-VD, -430B-VD-2-450B-VD-2 For close mounting of two or three SSRs, limit the load current to 80% or less. 8

Input Voltage vs. Input Current -2@0B-VD(-X) -4@0-VD, -4@-VD-2 Input impedance (kω) Input current (ma) 8 6 4 2 1 0.8 0.6 Input current Input impedance Ta = 25 C Input impedance (kω) Input current (ma) 10 T = 25 C 8 6 4 2 1 0.8 0.6 Input current Input impedance 0.4 0.4 0.2 0.2 0.1 1 2 4 6 8 10 40 Input voltage (V) 0.1 1 2 4 6 8 10 40 Input voltage (V) Horizontal Mounting Panel Ground -240B-VD -260B-VD 28 11 10 60 42 40 18 30 0 40 60 80 100-4B-VD, -430B-VD -4B -VD-2, -430B-VD-2-450B-VD-2-430B-VD -4B-VD 9

Close Mounting (Up to Three) Panel Ground DIN track -240B-VD -260B-VD 45 40 36 30 14 10 64 48 40 30-4B-VD, -4B-VD-2-30 - 0 40 60 80 100-430B-VD, -430B-VD-2 40 16 10 30 24 10 30 10 30 80 100-450B-VD-2 30 10 30 80 10

One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. -4B-VD, -4B-VD-2-240B-VD/260B-VD, -430B-VD, -430B-VD-2, -450B-VD-2 Inrush current (A. Peak) Inrush current (A. Peak) Energized time (ms) Energized time (ms) 11

Dimensions Note: All units are in millimeters unless otherwise indicated. -4B-VD, -4B-VD-2 Without Terminal Cover Two, M4 With Terminal Cover 4.6 dia. Mounting Holes Two, 4.5 dia. or M4 Terminal Arrangement/ Internal Connections 7.6 90±0.2 Linking terminal 67 +B1 38 100 max. 80 Linking terminal B2 90±0.3 Trigger circuit Input circuit 8.6 2.2 8.8 Two, M3.5 25±0.2 4.5 4.5 x 5.6 elliptic hole 37 max. 100 max. 13.2 90 91-240B-VD -430B-VD -430B-VD-2 Without Terminal Cover Linking terminal B1 Two, M5 With Terminal Cover 4.6 dia. Mounting Holes Two, 4.5 dia. or M4 holes Terminal Arrangement/ Internal Connections Two, M3.5 Trigger circuit Input circuit Linking terminal B2 4.6 x 5.6 elliptical hole 100 max. -260B-VD -450B-VD-2 With Terminal Cover 4.6 dia. Without Terminal Cover Two, M5 Two, M3.5 Mounting Holes Two, 4.5 dia. or M4 holes Terminal Arrangement/ Internal Connections -260B -VD -450B -VD-2 1 + A1 1 + A1 Trigger circuit Input circuit Trigger circuit Input circuit 4.6 x 5.6 elliptical hole 110 max. 2 A2 2 A2 100 max. 12

Safety Precautions Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Input SSR Load Load power supply Load Connection For an AC load, use a power supply rated at 50 or 60 Hz. The maximum operating frequency is 10 Hz. The -(VD) has a built-in varistor for overvoltage protection. At a low applied voltage, such as 24 VAC, the load current is not fully supplied. When the Unit is switched ON, the voltage required to power the Unit deprives the output signal of the necessary voltage level and thus creates loss time. The lower the load voltage is, the greater the loss time is. This condition, however, will not create any serious problems. When attaching a heat sink to the -(VD), in order to facilitate heat dissipation, apply silicone grease or equivalent heat-conductive grease on the heat sink. (Toshiba Silicone, Shinetsu Silicone, etc.) Tighten the mounting screws of the heat sink with a torque of 0.78 to 0.98 N m. Noise Terminal Voltage according to EN55011 The -(VD) complies with EN55011 standards when a capacitor is connected to the load power supply as shown in the following circuit diagram. Input -(VD) Output Load Loss time For a DC or L load, a diode should be connected in parallel the load to absorb the counter electromotive force of the load. Recommended Capacitor: 1 μf, 250 VAC Mounting Screw or DIN track mounting is possible. Vertical mounting should usually be used. Vertical mounting Vertical Panel The rated ambient temperature is 40 C. (30 C for 400 V.) Close mounting Vertical DIN track Vertical Close mounting cannot be used if the SSR is used at a 100% load current. Leave a gap of at least 10 mm on the left and right of each Unit. Close mounting can be used under the following conditions: 1. Close mounting can be performed with no more than three SSRs (For four or more SSRs, leave a gap of at least 10 mm.) 2. Use a load current of 80% or less (90% or less for the -210B-VD, -2B-VD, or -240B-VD). 3. Leave a gap of at least 80 mm above and below the SSR. 4. Leave a gap of at least 60 mm from wiring ducts to the top of the SSR and at least 30 mm from wiring ducts to the bottom of the SSR. 80 mm DIN track Horizontal mounting Panel With vertical mounting, reduce the load current by 30%. (Refer to the Load Current vs. Ambient Temperature graph.) Note: Leave a distance of 60 mm min. between SSRs and ducts (especially above the SSR). 13

Close Mounting SSR Mounting Pitch Panel Mounting (At a rated ambient temperature of 40 C). Mounting direction Vertical direction Space between SSRs Relationship between SSRs and Ducts Duct Height Mounting surface Duct or airflow obstruction SSR 80 mm min. Duct or airflow obstruction Vertical direction min. 60 mm min. Close Mounting Between duct or airflow obstruction and SSR 30 mm min. Countermeasure (1) Countermeasure (2) Mounting surface 50 mm max. (A height of no more than half the SSR's height is recommended.) Mounting surface Airflow A heat exchanger, if used, should be located in front of the SSR Units to ensure the efficiency of the heat exchanger. Please reduce the ambient temperature of SSRs. The rated load current of an SSR is measured at an ambient temperature of 25 or 40 C. An SSR uses a semiconductor in the output element. This causes the temperature inside the control panel to increase due to heating resulting from the passage of electrical current through the load. To restrict heating, attach a fan to the ventilation outlet or air inlet of the control panel to ventilate the panel. This will reduce the ambient temperature of the SSRs and thus increase reliability. (Generally, each 10 C reduction in temperature will double the expected life.) 10 A A 30 A 40 A 60 A Required number of fans 0.16 0.31 0.47 0.62 0.93 per SSR Example: For 10 SSRs with load currents of A, 0.31 x 10 = 3.1 Thus, 4 fans would be required. Size of fans: 92 mm 2, Air volume: 0.7 m 3 /min, Ambient temperature of control panel: 30 C If there are other instruments that generate heat in the control panel other than SSRs, additional ventilation will be required. Duct or airflow obstruction Do not surround the SSR with ducts, otherwise the heat radiation of the SSR will be adversely affected. Ventilation Use short ducts. If the ducts cannot be shortened, place the SSR on a metal base so that it is not surrounded by the ducts. Be aware of air flow Duct or air flow obstruction Ventilation outlet Air inlet If the air inlet or air outlet has a filter, clean the filter regularly to prevent it from clogging and ensure an efficient flow of air. Do not locate any objects around the air inlet or air outlet, otherwise the objects may obstruct the proper ventilation of the control panel. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 14

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 18.3 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 18 All Right Reserved.