International Journal of Scientific & Engineering Research, Volume 6, Issue 7, July ISSN

Similar documents
International Journal of Scientific & Engineering Research, Volume 6, Issue 7, July ISSN ULTRA FAST CIRCUIT BREAKER

Design and Implementation of an Automatic Power Supply from Four Different Source Using Microcontroller

DESIGN AND IMPLEMENTATION OF THREE PHASES AUTOMATIC CHANGE OVER SWITCH

DESIGN OF AUTOMATIC CHANGE OVER SWITCH WITH GENERATOR CONTROL MECHANISM

CONTINUOUS POWER SUPPLY BY SWITCHING THREE SOURCES

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

Review paper on Fault analysis and its Limiting Techniques.

Battery to supply nonstop energy to load at the same time contingent upon the accessibility of the vitality sources. In

Soft Start for 3-Phase-Induction Motor

Shuttling of Metro Train between Stations

Maximum Solar Energy Saving For Sterling Dish with Solar Tracker Control System

A Novel Solar Tracking System using AT89C51 Microcontroller and LDR

Analysis of the Effect of Electric and Magnetic Loadings on the Design Parameters of an Induction Motor and Its Performance Using Matlab/Simulink

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

International Journal of Advance Engineering and Research Development

THE SOLAR POWERED ANTI-THEFT BAG

Computer Aided Transient Stability Analysis

320 to 327 M Series Low and Medium Voltage Motor Protection Relays

COMPARISON OF SOLAR TRACKING WITH FIXED PANEL POWER GENERATION (WITHOUT LOAD)

Abstract- A system designed for use as an integrated starter- alternator unit in an automobile is presented in this paper. The

REVISED ATM72 Auto Transfer Module

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

AUTOMATIC ROAD DIVIDER PAINTING MACHINE FOR SMART CITIES

Designing Of Overload Monitoring System In Public Transportation Based On Microcontrollerin Ethiopia

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Energy Production with Multiple Sources and Line Selection with Jumping Priority for Power Distribution Return Feeding Line. I.

Automated System for Air Pollution Detection and Control in Vehicles

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

ECO BIKE TEST PLAN DOCUMENT

THREE PHASE FAULT ANALYSIS WITH AUTO RESET ON TEMPORARY FAULT AND PERMANENT TRIP OTHERWISE

Controls and Instruments

8051 MICRO-CONTROLLER BASED ROBOTIC CAR

SDC,Inc. SCR-Regenerative Ac Drive

Application Engineering

Solar Based Wireless Grass Cutter

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

PLC BASED AUTOMATIC RAILWAY GATE CONTROLLER AND OBSTACLE DETECTOR

Electromagnetic Industries LLP

SMART AUTOMATION IN RAILWAY SYSTEM

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

Performance Analysis of Transient Stability on a Power System Network

A DIGITAL CONTROLLING SCHEME OF A THREE PHASE BLDM DRIVE FOR FOUR QUADRANT OPERATION. Sindhu BM* 1

SMART MICRO GRID IMPLEMENTATION

OVERLOAD PROTECTION. All electrical circuits must have some means of protecting against overload.

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

White Paper. Application of Resistive/Reactive Load Banks for kva Testing

OPERATING INSTRUCTION: DGC-6D/6D1I

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

A Comparison of Typical UPS Designs in Today s Markets

Hybrid Off Grid Solar UPS

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

AUTO-EC-3-E-PLC Electric Filter Backwash Controller Operation & Maintenance Manual

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

Application Engineering

MOTOR TERMINAL CONNECTIONS

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

Door Control Panel TS 960. instructions. (Design and functions subject to change) /

Achieving the Highest Power Density in the Smallest Footprint

BURGLAR ALARM KIT MODEL K-23. Assembly and Instruction Manual ELENCO

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

World Scientific Research Journal (WSRJ) ISSN: Multifunctional Controllable and Detachable Bicycle Power Generation /

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

AUTOMATIC UNDERGROUND CAR PARKING SYSTEM

Development of Electrical Power System Simulator.

Design and Manufacturing of Self Inflating Tire System

Design and Implementation of Driving Circuits for DC Motor Control Using 8051 Ashmi.M 1 Prasanna Kumar M 2 Dr. K. S.

SURE TRIP RETRO KITS

Fabrication and Automation of Solvent less Packaging Machine

Cat/DCG-6D1I/07-08/03/Ver 1 Page 2/10

ICON 2 1. FEATURES AND CHARACTEIRICS

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

Level 7 Post Graduate Diploma in Engineering Mechatronics

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

AG. 225 AGRICULTURAL SYSTEMS/ELECTRICITY AND HYDRAULICS

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

Training & Didactic Systems. Fundamentals of Electrical Engineering

OFF-GRID Hybrid (BI-DIRECTIONAL) SOLAR INVERTER SOLAR INVERTER SOLAR UPS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY

Common Bus and Line Regeneration

Design and Fabrication of Automated Hacksaw Machine

SECTION MOTOR CONTROL

Modelling and Simulation of DFIG based wind energy system

Solar tracker is the best solution for receiving maximum radiation.

Theft Detection and Controlling System of a Vehicle Using GSM

Maximum Demand Control using Microcontroller AT89c51

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

SDM72 Start on Demand Modules

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

Analysis and Design of Improved Isolated Bidirectional Fullbridge DC-DC Converter for Hybrid Electric Vehicle

Analysis of Grid Connected Solar Farm in ETAP Software

Impact of Reflectors on Solar Energy Systems

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Turbine Lube Oil System Monitoring and Control using PIC Controller

Train Group Control for Energy-Saving DC-Electric Railway Operation

Transcription:

International Journal of Scientific & Engineering Research, Volume 6, Issue 7, July-2015 81 AUTOMATIC TRANSFER SWITCH WITH THREE PHASE SELECTOR OKOME ORITSELAJU M*, FOLORUNSO OLADIPO** DEPARTMENT OF ELECTRICAL/ELECTRONIC, AFE BABALOLA UNIVERSITY, ADO-EKITI, EKITI STATE, NIGERIA ABSTRACT: Constant supply of power is the wheel of growth to any nation s economy. A country like Nigeria, where total power generation is less than one quarter of total demand, means of augmentation and smooth operation cannot be over emphasized. This paper presents a real laboratory design and construction of Automatic Transfer Switch (ATS) with three phase selector. The design method involves the use of electromechanical type relays, and comparators, etc. The ATS designed demonstrates its ability to perform automatic power change over activities easily without any human interaction. Keywords: Automatic Transfer Switch (ATS), relay, comparator. I. INTRODUCTION In developing countries like Nigeria today, there is the problem of interrupted power supply as insufficient power is being generated to provide consumers with continuous services and satisfactory quality. This leads to constant power failure which in turn affects both the public and private sectors of the economy. Industries, banks, hospitals and so many other public and private establishment all have major critical loads that needs to be powered at all times in order to carry out various processes efficiently. This power instability now brought about the need to create an alternative means of power to back up the public utility supply. The introduction of some of these alternative sources of power supply brings forth the challenge of switching smoothly in a timely manner between the mains supply and the alternative sources whenever there is a failure on the mains source. Automatic changeover switch is an integral part of the process of power generation, allowing smooth and instant transfer of electric current between multiple sources and load. The function of the automatic change over switch is to monitor the incoming public supply voltage and detect when the voltage drops below a certain level that electrical/electronic appliances can function depending on the utility supply. The automatic change over switch compares the voltage of the other two phases using a comparator circuit and if the voltages are not available, the system changes over from public supply to generator. When the generator is in operation, the transfer switch prevents any feedback current to the load. It also ensures that the different power sources are synchronized before the load is transferred to them. The transfer switch senses when there is interruption if the mains supply remains absent. The principle of the automatic changeover switch is such that it links the load and mains supply or the alternative supply together. This enables the use of either the mains supply or an alternative source when there is outage on the mains source which can either be a three phase or a single phase. The automatic transfer switch embedded with a phase selector comprises of a monitoring unit which monitors the three phases and gives a single output as well as monitoring the output that comes from the generator, a control unit that controls the operation of the circuit, the relay drivers necessary for driving the relays used for putting off and on the generator as well as alternating between the 2015

International Journal of Scientific & Engineering Research, Volume 6, Issue 7, July-2015 82 two power supplies, and the stepper motor driver unit which is used for moving the stepper motor that controls the choke in starting the generator. The block diagram of the circuit is shown in figure 1.1 Figure 1.1: Block diagram showing the working principle of an automatic transfer switch with three phase selector. II. DESIGN METHODOLOGY The methods and procedures involved in the design and fabrication of the automatic transfer switch with three phase selector that gives a single output involves the following: a) Paper design of the circuit b) Obtaining all the components required to make the circuit of the automatic transfer switch c) The four 240/12v, 300mA transformers, 1000µF capacitors, bridge rectifiers, variable resistors are all connected to the LM324 op amp which is used to monitor if there is voltage in the red, yellow and green phase as well as if the generator is supplying current to the load. d) LEDS are used as indicators for the three phases as well as for the generator. The LM324 is then connected to the micro controller which controls the display of the LCD as well as the starting and stopping of the generator. e) Relay drivers and motor drivers are connected to the microcontroller to drive the relays and the bipolar stepper motor of the generator during 2015

International Journal of Scientific & Engineering Research, Volume 6, Issue 7, July-2015 83 start/stop of the generator as well as switching between the public supply and generator. The whole circuit is powered by a 240/12v, 500mA transformer. f) The circuit has a 5secs delay before the generator comes on when there is no supply in any of the three phases. It also has a 5secs delay before the generator comes off when there is supply in any of the three phases.. g) When the generator refuses to come on after three attempts in starting, the buzzer sounds for 5secs before coming off. h) When the reset switch is off and there is no supply in any of the phases, the generator would not also start till that switch is turned on. Figure 2.1: Circuit Diagram showing design and construction of the automatic transfer switch. III. TESTING AND RESULT The total cost of materials for the laboratory design of Automatic Transfer Switch in Department of Electrical/Electronic Engineering, Afe Babalola University, Ado Ekiti, Nigeria is 12, 235 Naira (about $57). 2015

International Journal of Scientific & Engineering Research, Volume 6, Issue 7, July-2015 84 Figure 3.1 Automatic Transfer Switch during under construction The automatic transfer switch circuit was circuit. It put the generator ON and OFF as tested with the three phases power supply required and alternated between the two available. The switching process was power supplies. The following test results perfectly executed by the control switching were obtained. Table 3.1: Tests and results analysis TESTS RESULTS Automatic Switching ON and OFF of the generator The switching control circuit was able to switch ON and OFF the generator when the mains supply in all three phases was not available and when at least one phase was made available. 2015

International Journal of Scientific & Engineering Research, Volume 6, Issue 7, July-2015 85 Switching between the three available phases. The monitoring unit in the circuit was able to interchange between the phases circuit whenever anyone was of the phases were not available. Switching between the two available power supply sources The switching control circuit did the switching between the two power supply sources correctly avoiding any jam in supply when the two supplies are available simultaneously. Timing of the delay circuits test All the timed delay circuits worked satisfactorily within ±1secs tolerance. Buzzer alarm test The buzzer alarm to indicate when the generator refuses to come on after 3 attempts to start worked satisfactorily. Reset switch test When the reset switch is off and there is no supply in any of the phases, the generator did not start till that switch was turned back on. IV. Performance Evaluation In other to test the performance of the system, Switch R is the switch controlling the red phase, Switch Y is the switch controlling the yellow phase, Switch G is the switch controlling the green phase, switch O is the reset switch, and the buzzer is the gen fault indicator. During this test, the public supply is available in the three phases. A 60 W bulb is used as the load and a 12 Volts motor is used as the kick-starter to move the choke of the generator. The following steps were involved in the operation of the circuit: a) Switch R opened (OFF) simulates public supply outage. b) Switch Y opened (OFF) simulates public supply outage. 2015

International Journal of Scientific & Engineering Research, Volume 6, Issue 7, July-2015 86 c) Switch G opened (OFF) simulates public supply outage. d) Switch R closed (ON) simulates public supply availability. e) Switch Y closed (ON) simulates public supply availability. f) Switch G closed (ON) simulates public supply availability. h) Switch O closed (ON) availability of generator. i) Motor ON means the 12V motor rotates clockwise for 2sec, and anti clockwise for the next 2secs. j) Bulb ON means the 60W bulb lights by both source of power supply. g) Switch O opened (OFF) simulates unavailability generator. Table 4.1: Summary of performance evaluation Steps Switch R Switch Switch Switch Motor Buzzer Bulb Comments/Observations B G O 1 ON ON ON ON OFF OFF ON When all three phases are ON, the generator and the buzzer are off and the load would be powered. 2 OFF ON ON ON OFF OFF ON When two out of the three phases are ON, the generator and the buzzer are off and the load would be powered. 3 OFF OFF ON ON OFF OFF ON When one out of the three phases is ON, the generator and the buzzer are off and the load would be powered. 4 OFF OFF OFF ON ON OFF ON When all three phases are OFF, there is a delay of 5secs, before the motor comes on and powers the load. 5 OFF OFF OFF ON OFF ON OFF When all three phases are OFF and the motor is OFF due to a fault in the generator after three attempts at starting, the buzzer comes ON for 5secs 6 OFF OFF OFF OFF OFF OFF OFF When all three phases are OFF, and switch O is OFF indicating the non availability of the generator, the motor, load and 2015

International Journal of Scientific & Engineering Research, Volume 6, Issue 7, July-2015 87 buzzer would also be OFF till switch O is turned ON V. CONCLUSION Based on the test results, the whole system performed according to the designed aim and objectives. The automatic transfer switching circuit was able to switch between the two power supply sources according to the set priority and also automatically off. The project has been proven to be very reliable and can be deployed in houses, offices, industrial settings and all environments where constant power supply are of great importance. With improved rating of the generator more percentage of loads can be placed on them. switches on the generator and switches it REFERENCES mechanism, Electrical Power and 1. Ahmed.M.S, Mohammed.A.S and Electronic Development Department, Agusiobo.O.B, Development of a Projects, Development Institute Single phase Automatic Change- (PRODA), Enugu, NIGERIA, Over Switch, Department of Electrical and Computer Engineering, Federal University of Technology Minna, Nigeria, July 2006. 2. Ezema L.S, Peter B.U, Harris O.O, design of automatic change over switch with generator control November 2012. 3. Jonathan Gana Kolo (2007). Design and Construction of an Automatic Power Change over Switch. AUJ. T. II (2): 113 118 (October 2007). 4. Theraja, B.L.; and Theraja, A.K. 2002. Electrical Technology, 21 st ed. Ranjendra Ravida, New Delhi, India. 2015