PerfmancePipe.com DRISCOPIPE 8100 HDPE PIPE and FITTINGS DATA SHEET Driscopipe 8100 Pipe and Fittings meet exceed: Driscopipe 8100 Pipe and Fittings f: ASTM D2513, D2683, D3261 ASTM D3350, cell classification PE445574C and PE445576C PPI TR-4 designation PE4710 (PE3408) and PE100 PPI TN-30 Natural Gas Distribution, LPG and Propane Gas, Yard Gas Iron Pipe OD (IPS) ½ to 12, Copper Tube OD (CTS) ½ to 1 ¼ Coils available up through 6 Outdo Stage up to Three (3) years per ASTMD2513 NOMINAL PIPE PROPERTIES (1) UNIT TEST METHOD VALUE Density gms / cm 3 ASTM D1505 0.961 (black) Melt Index (HLMI) 190 C / 21.6kg gms / 10 minutes ASTM D1238 9.0 Hydrostatic Design Basis 73º F (23º C) psi ASTM D2837 1600 Hydrostatic Design Basis 140º F (60º C) psi ASTM D2837 1000 Minimum Required Strength (MRS) @ 20º C (68º F) Mpa (psi) ISO 9080 >10 (>1450) Rapid Crack Propagation Critical Pressure (Pc), 0ºC (32ºF) (3) Critical Temperature (Tc), 5 bar (4) Bar (psi) ºC (ºF) ISO 13478 ISO 13477 >30 bar (>435 psi) <-24ºC (<-11ºF) Col: UV Stabilizer [C] [E] ASTM D3350 [C] Min 2% Carbon Black [E] UV Stabilizer, Yellow Pipe Test Categy --- ASTM D2513 CEE NOMINAL MATERIAL PROPERTIES (1) (2) UNIT TEST METHOD VALUE Flexural Modulus @ 2% Strain psi ASTM D790 >140,000 Tensile Strength at Yield psi ASTM D638 Type IV >3500 Elongation at Break 2 in / min., Type IV Bar % ASTM D638 >800 Hardness She D ASTM D2240 65 PENT hrs ASTM F1473 >2000 Vicat Softening Temperature ºF ASTM D1525 255 Brittleness Temperature ºF ASTM D746 <-103 Thermal Expansion in / in / ºF ASTM D696 1.0 x 10-4 1. This is not a product specification and does not guarantee establish specific minimum maximum values manufacturing tolerance f material piping products to be supplied. 2. Values obtained from tests of specimens taken from piping product may vary from these typical values. 3. Determination made on 12" DR-11 pipes f Full Scale test. Pc calculated in accdance with ISO 13478. 4. Determination made on 8" DR-11 pipes. No failures occurred. Tc calculated in accdance with ISO 13477 Annex C Crelation. 5. Melt Index (MI) value determined in accdance with ASTM D3350 Cell Classification is <0.15 gm/10 min at 2.16kg condition. Bulletin: PP108 / January 2012 2009 Chevron Phillips Chemical Company LP Perfmance Pipe, a division of Chevron Phillips Chemical Company LP 5085 W. Park Blvd Suite 500 Plano, TX 75093 Phone: 800-527-0662 Fax: 972-599-7348 This data sheet provides typical properties f Perfmance Pipe DriscoPlex pipe and fittings. Befe using this product, the user is advised and cautioned to make their own determination and assessment of the safety and suitability of the product f the specific use in question and is further advised against relying on the infmation contained herein as it may relate to any specific use application. It is the ultimate responsibility of the user to ensure that the product is suited and the infmation is applicable to the user s specific application. Chevron Phillips Chemical Company LP does not make, and expressly disclaims, all warranties, including warranties of merchantability fitness f a particular purpose, regardless of whether al written, express implied, allegedly arising from any usage of any trade from any course of dealing in connection with the use of infmation contained herein the product itself. The user expressly assumes all risk and liability, whether based in contract, tt otherwise, in connection with the use of the infmation contained herein the product itself. Further, infmation contained herein is given without reference to any intellectual property issues, as well as federal, state local laws which may be encountered in the use thereof. Such questions should be investigated by the user. The data sheet may change periodically. Visit www.perfmancepipe.com f the most current data sheet. Page 1 of 1
CTS = COPPER TUBE SIZE Outside Diameter 1/2" 0.625 Minimum Wall Dimension Ratio MAOP (psig per CFR Part 192 @100 F less) Weight per 100 ft. Coil/ Joint (feet) 0.062 DR 10.1 4.8 500' 100 0.090 DR 6.9 6.6 1000' DRISCOPIPE 8100 Series and Dimension Sheet NOTE: The sizes and packaging shown represent typical Perfmance Pipe products. Other sizes and/ packaging may be available. Contact Perfmance Pipe f additional infmation. Pipe weights are calculated in accdance with PPI TR-7. Dimensions and weights are subject to change without notice. Please visit www.perfmancepipe.com f the most up-to-date infmation Packing Dimensions ID / OD / Width 30" / 38" / 6" 30" / 44" / 6" Coils / Joints Per Pallet 12 Pallet/ Footage 6,000' 12,000' Pallet / s Per 26 48 ft. 156,000' 312,000' 3/4" 0.875 0.090 DR 9.7 100 9.7 500' 30" / 38" / 11" 6 3,000' 26 78,000' 0.090 DR 12.5 89 13 1" 1.125 0.101 DR 11.1 100 14 500' 30" / 42" / 11" 8 4,000' 26 104,000' 0.121 DR 9.3 123 17 0.090 DR 15.3 72 16 1 1/4" 1.375 0.121 DR 11.4 99 21 500' 32" / 45" / 14 1/2" 6 3,000' 24 72,000' IPS = IRON PIPE SIZE MAOP (psig Minimum Weight Coil/ Packing Pallet/ Dimension Outside per CFR Part Coils / Joints Pallet / 48 ft. Wall per Joint Dimensions Ratio Diameter 192 @100 F Per Pallet s 100 ft. (feet) ID / OD / Width Footage less) Per 1/2" 0.840 0.090 100 9 500' 30" / 44" -6" 14 7,000' 26 182,000' 3/4" 1" 1 1/4" 2" 3" 4" 6" 8" 10" 12" DR 9.3 0.113 123 15 1.050 DR 11 0.095 100 13 0.141 123 23 1.315 DR 11 0.120 100 20 DR 7 0.237 125 46 1.660 0.178 123 36 DR 11 0.151 100 31 DR 7 0.339 125 95 DR 9.3 2.375 0.255 123 75 DR 11 0.216 100 64 0.375 123 161 40' 3.500 DR 11 0.318 100 140 500' 0.482 123 266 40' 4.500 DR 11 0.409 100 230 500' 0.710 123 598 DR 11 6.625 0.602 100 501 DR13.5 0.491 82 416 DR 9.0 0.958 125 1013 DR 11 8.625 0.784 100 849 DR 13.5 0.639 82 705 DR 11 0.977 100 1311 10.750 DR 15.5 0.694 71 960 DR 11 1.159 100 1855 DR 15.5 12.750 0.823 71 1357 DR 21 0.607 51 1021 500' 30" / 44" / 11" 7 3,500 26 91,000' 500' 30" / 44" / 12" 6 3,000' 26 78,000' 500' 48" / 72" / 7 1/2" 12 6,000' 7 42,000' 500' 52" / 78" / 13" 7 3,500' 7 24,500' 40' 500' soft bundles 70" / 96" / 23 3/4" soft bundles 70" / 93" / 41" soft bundles 84" / 120" / 50" 50 4 29 2 13 Upright 2,000' 1,160' 1,100' 520' Upright 14 6 14 6 14 8 28,000' 12,000' 16,240' 6,000' 7,280' 4,000' 40' soft bundles 9 360' 10 3,600' 40' bulk packs 9 jts/layer 360' 7 2,520 40' bulk packs 8 jts/layer 320' 6 1,920' Perfmance Pipe, a division of 5085 W. Park Blvd, Suite 500 Phone: 800-527-0662 Bulletin: PP 158 Page 1 of 1 February 2012 Supersedes all previous publications 2003 2012 Chevron Phillips Chemical Company LP
IPS Gas Soft Sided s PERFORMANCE PIPE IPS PRODUCTS SOFT-SIDED BUNDLES (20,40 & 50 Joints) (Note 1) Style Pipe OD Joints Per s Per 20 /40 /50 Joints Per 20 /40 /50 DR 20 Joints 40 Joints 50 Joints 20 / 10 / NA 1,000 / 500 / NA 7 20,000 20,000 N/A 3 Soft 3.500 50 26 / 13 / NA 1,300 / 650 / NA 9 26,000 26,000 N/A 28 / 14 / NA 1,400 / 700 / NA 11-19 28,000 28,000 N/A 22 / 11 / 9 638 / 319 / 261 7 12,760 12,760 13,050 4 Soft 4.500 29 28 / 14 / 11 812 / 406 / 319 9 16,240 16,240 15,950 28 / 14 / 13 812 / 406 / 377 11 16,240 16,240 18,850 28 / 14 / 14 812 / 406 / 406 13.5-19 16,240 16,240 20,300 22 / 11 / 9 286 / 143 / 117 7 5,720 5,720 5,850 6 Soft 6.625 13 28 / 14 / 11 364 / 182 / 143 9 7,280 7,280 7,150' 28 / 14 / 14 364/ 182 / 182 11-19 7,280 7,280 9,100 8 Soft 8.625 9 20 / 10 / 10 180 / 90 / 90 11-19 3,600 3,600 4,500 Note 1: GAS DISTRIBUTION When travelling in states with a 13 6 maximum height restriction shipping 13 14 bundles of 3 6 may exceed the height restriction unless the trailer height is 58 below (depending on the thickness of the bottom board utilized). Revised: 02/27/2013 Page 1 of 5
IPS Gas Soft Sided s Soft Sided Style: F encasing all straight lengths between 3.500 OD and 8.625 OD. (1) Lumber s and Placement: (a) Will be constructed using 3 x 4 bottom boards f GAS DISTRIBUTION (SERIES 6500-8100-8300).( 3 x 4 boards actually have a thickness of approximately 2.5, not to be less than 2) Hardwood softwood is acceptable. Grooved boards are preferable, but not mandaty as the banding will create a notch in some soft woods securing the banding in place. (b) The bottom board length requirement is that the bottom board must go past the center point of the outer joints but not extend past the outer edge of the outer joint. IPS Pipe Target Board Length 3 42 (+0.75, -0.00) 4 42 (+0.75, -0.00) 6 42 (+0.75, -0.00) 8 42 (+0.75, -0.00) (c) Bottom boards are spaced at three (3) equidistant locations f twenty-foot (20 ) joints. (d) Bottom boards are spaced at six (6) equidistant locations f fty-foot (40 ) joints. (e) Bottom boards are spaced at seven (7) eight (8) equidistant locations f fifty-foot (50 ) joints depending on bundling cart and plant. (2) Top Boards: (a) Top boards may be used to increase the stability of 3 to 8 soft bundles at manufacturer s discretion at the customer s request. (b) Top boards are placed on each end of the bundle, in line with the end bottom board. (Optional middle top boards are acceptable) (c) Top boards may be constructed of 2 X 6 boards. The thickness of the top board should not exceed the thickness of the bottom board. Hardwood softwood is acceptable. (d) The top board length requirement is that the top board must go past the center point of the outer joints but not extend past the outer edge of the outer joint. IPS Pipe Target Board Length 3 42 (+0.75, -0.00) 4 42 (+0.75, -0.00) 6 42 (+0.75, -0.00) 8 42 (+0.75, -0.00) Revised: 02/27/2013 Page 2 of 5
IPS Gas Soft Sided s (3) Banding: It is imptant that each band on a soft-side bundle be tightened to the same tension. Air regulated battery operated banding equipment is acceptable. Use at least one ¾ X.050 5/8 X.035 polyester banding per bottom board. If using 5/8 X.035 polyester place one band around pipe between boards. At the plant s discretion one band may please placed around the pipe on each end of the pack to help secure the caps/plugs and to stabilize the pack. (4) Stage: Soft-side bundles must be stacked plumb to prevent leaning. Special care must be taken when staging bundles in stage. Packs may be stacked in the plant yard on lumber to prevent the bottom of the pipe from coming in contact with the ground. (5) Transpt: Perfmance Pipe Transpt Strapping Policy (A.10 Pckg EXH2-Strapping Table) establishes minimum requirements regarding the number of trucker straps used by all transptation providers to secure bundles. The policy also contains conditions regarding the tightening of straps after a carrier leaves a Perfmance Pipe facility. (6) Tarping: All 6500-8100-8300 series bundles may be smoked tarped at least 8 back on top and 8 in front and on sides full tarped depending on customer request. (7) End Caps: Place ventilated end caps ( plugs) on all 6500-8100-8300 series products. Revised: 02/27/2013 Page 3 of 5
IPS Gas Soft Sided s IPS Soft Sided s (Examples) 3 IPS 4 IPS 50 Joints Per 29 Joints Per 6 IPS 8 IPS 13 Joints Per 9 Joints Per GAS DISTRIBUTION ONLY Revised: 02/27/2013 Page 4 of 5
IPS Gas Soft Sided s IPS Soft Sided Patterns (20, 40 & 50 Joints) Pipe OD Style Height (Note 2) BTM Board Length (Note 1) Joints Per s Per 20 /40 /50 Pattern DR 20 40 50 3 (Note 3) 3.500 Soft 15.093 42 50 20/10/NA 7 1,000 2,000 N/A 26/13/NA 13/12/13/12 9 1,000 2,000 N/A 28/14/NA 11-19 1,000 2,000 N/A 22/11/9 7 580 1,160 1,450 4 4.500 Soft 14.794 42 29 28/14/11 9 580 1,160 1,450 10/9/10 28/14/13 11 580 1,160 1,450 28/14/14 13.5-19 580 1,160 1,450 6 6.625 (Note 3) 8 8.625 Soft 14.862 42 13 Note 1 : Figure is also top board length 22/11/9 7 260 520 650 28/14/11 7/6 9 260 520 650 28/14/14 11-19 260 520 650 Soft 18.594 42 9 20/10/10 5/4 11-19 180 360 450 Note 2 : height determined using 2 ½ thick boards. Note 3 : When travelling in states with a 13 6 maximum height restriction shipping 13 14 bundles of 3 6 may exceed the height restriction unless the trailer height is 58 below (depending on the thickness of the bottom board utilized). Revised: 02/27/2013 Page 5 of 5