Product Flyer ELC ELECTRONIC LAMP CONTROL

Similar documents
UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

ABB central inverters PVS to 1000 kw

ABB central inverters PVS to 1000 kw

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

Versatile and Powerful. Liduro Wind Frequency Converter System

Motor Starter Reverse MSR22-FBP

MASTERYS IP+ 10 to 80 kva

TECHNICAL DATA SHEET KVA UPS Systemss

FINHRM FINHRM5 FINHRMA FINHRMAC

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

FL ballasts Electronic fixed output. PC TCL PRO, W PC PRO compact

Electronic ballasts for fluorescent lamps Multi-lamp ECG. PC T5 PRO-M lp, W T5, T8, compact (CFL) and T5c circular fluorescent lamps

High performance Vector Control. Ratings. System configuration

MGE TM Galaxy TM 7000 GFC

Hi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

PC T8 TEC, W PC TEC

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Modular three-phase UPS system. DPA UPScale RI kw The modular UPS for customized solutions

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

DPA UPScale RI kw The modular UPS for customized solutions

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

HVAC Products. Introducing the SED2 Variable Frequency Drives

Electronic ballasts for fluorescent lamps Professional electronic ballast

MEDIUM VOLTAGE DRIVE STARTER TYPE MV-SVFD-ML1

Emergency lighting units PC COMBO

LED Driver Linear / area fixed output

FL ballasts Electronic fixed output PC T8 PRO, W PC PRO T8

Appendix: Safety and application notes for... 15

ELEMENT. Product family datasheet. Constant Voltage Non dimmable

Product Overview. Key Features. (ship.unit) PARATHOM MR ,5 W 2700 K 210 GU mm 50 mm 32 g

MGE TM Galaxy TM 7000

Sunny Tripower CORE1.

PC T8 PRO, W T8 fluorescent lamps

J TS 7090 Thyristor power switch

Spark-ignited generator set

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

EFFEKTA Power Supplies

FL ballasts Electronic fixed output

Starts, stops and protects. Emotron TSA Softstarter

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

SMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems

HIGH-PERFORMANCE MEDIUM VOLTAGE LOAD-COMMUTATED CURRENT SOURCE INVERTER POWER ELECTRONICS FOR INDUSTRIAL APPLICATIONS SISTEMI INDUSTRIALI

FL ballasts Electronic fixed output. PC TC PRO 1/2x9 70 W PC PRO compact

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps

The motor starter on the power bus. Solutions for conveyor technology. Full speed ahead

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

Master Plus kva

ATevo SERIES BATTERY CHARGER

Emergency lighting units PC COMBO

Master Plus kva

Green Power 2.0 MASTERYS GP

PEL power supplies. 24 Vdc 18 Vdc 12 Vdc SWITCHED MODE POWER SUPPLIES/ PEL SERIES

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB central inverters PVS to 2000 kva

ABB central inverters ULTRA-750/1100/ kW to 1560kW

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

Est FlexiPower Mini UPS FPX Mini kVA

Customized drive solutions

Unidrive M700 Class leading performance with onboard real-time Ethernet

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Diesel generator set QSK23 series engine

ORION PLUS three-phase kVA

FL ballasts Electronic fixed output

ITW GSE 2400 COMPACT GPU kva solid-state GPU

MCD 200 Series Soft Starters

COMPARISION BETWEEN UV ELECTRIC S LW SERIES ELECTRONIC BALLASTS WITH OTHER BALLASTING ALTERNATIVES FOR HIGH-POWER UV DISCHARGE LAMPS

1.1 Caution Statements

Number 1 in efficiency

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

Single & Three-Phase Soft Starters

Spark-ignited generator set

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

Communication module. Brief description. Block structure Features. Page 1/5. Data Sheet

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

Technical Data Sheets

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

SENTINEL VA

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

Technical Data Sheets

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Emergency lighting units EM powerled

DDA AR-PVC/V/C with access.

Transcription:

Product Flyer ELC ELECTRONIC LAMP CONTROL

ELC General Information The electronic lamp control units ELC are designed to power UV medium pressure discharge lamps. In different series we offer fully integrated electronic lamp control solutions for UV lamps from 3 kw to 35 kw. Various air and water based cooling options offer most flexible and reliable power system integration. Special versions are designed for marine applications such as BWMS. The ELC control strategies allow easy PLC connection via PROFIBUS, Modbus or analog signals and supports smart lamp control, safety and servicing options. Technology: All ELC are based on a high frequency resonant power converter to precisely power the medium pressure lamps. This topology combines highest efficiency at lowest electromagnetic interference. The fully insulated lamp output allows perfect lamp matching as well as short circuit and earth fault resistant operation. Our MP lamps and cabinets: Our customer-specific in-house lamp manufacturing permits the optimum component match for your UV system. By using our power cabinets for ELCs you can be sure to have the most compact cabinet solution available. Coupled with the consistent quality strategy, we supply the industries most reliable and efficient UV components available on the market. And you can concentrate your resources on the development of your application specific UV equipment. System reliability smart soft ignition highest lamp lifetime Efficiency low heat exhaust highest ambient temperature energy savings Stepless lamp control dimming range 20 100% precisely controlled and monitored lamp status Mains compliance high power factor low harmonic distortion symmetric load no inrush current no start-up over-current Safety features insulated lamp output integrated earth fault detection short circuit proof

ELC series ELC X series lamp power: 4 kw, 6 kw, 8 kw, 12 kw,16 kw, 24 kw, 36 kw* Modbus and PROFIBUS control wide input voltage range 360 V to 528 V lowest harmonic distortion THDi protection IP 54 integrated heat exchange X_B series option for marine applications GL approved: 6 and 8 kw; other wattages under development UL approved: 4 to 36 kw ELC P and PE series nominal lamp power: 10 kw to 35 kw PROFIBUS control highest efficiency protection IP20 air cooled *36 KW version under development

ELC X series The result of intense in-house R&D and market experience; The X series combines ideal mains compatibility with a highly innovative cooling principle for best reliability and maximum installation flexibility. The field bus allows smart control and in- field diagnostics. Type Lamp Power Lamp Voltage Dimensions See ELC X4-40 4 kw 400 V Appendix A ELC X6-60 6 kw 600 V Appendix A ELC X8-80 8 kw 800 V Appendix A ELC X12-110 12 kw 1100 V Appendix A ELC X16-140 16 kw 1400 V Appendix A ELC X24-210 24 kw 2100 V Appendix A ELC X36-300* 36 kw 3000 V Appendix A *under development Data subject to technical alterations Technical Sheet Mains voltage wide input range 360V - 528V, 2 phase Power factor typ. > 97% Efficiency typ. > 94% Control port PROFIBUS and Modbus Safety interrupt built-in safety relay for emergency stop Lamp dimming typ. 20% to 100% range Lamp monitoring voltage, current, power, status Earth fault detection standard Max. distance to 40m (standard), (100m with special lamp cable)* lamp Protection IP54 Max. ambient 45 C (X_B series 55 C) temperature Cooling forced air cooling, no air filter required Dimensions H x W x D X4: 125 x 470 x 260 mm H x W x D X6: 125 x 470 x 320 mm H x W x D X8, X12: 125 x 470 x 420 mm H x W x D X16, X24: 250 x 470 x 420 mm H x W x D X36: 375 x 470 x 420 mm Weight X4: 11 kg, X6: 14 kg, X6B: 15 kg, X8: 18.5 kg, X8B: 19.5 kg, X12: 20.5 kg, X12B: 21.1 kg, X16: 37 kg, X24: 41 kg, X24B: 42.2 kg, X36: 61.5 kg, X36B: 63.3 kg Approvals CE, EN 50 178, UL for X4 to X36 and GL for X6 and X8 (other wattages under development) Special feature stacking option allows cabinet-free installation in one tower: X4 to X12 up to 12 modules, X16 and X24 up to 6 modules and X36 up to 4 modules.

ELC X_B series For marine applications like BWMS; This version of ELC X series is designed in compliance with IMO MEPC174(58) regulation. max. temperature 55 C vibration proof humidity proof (IP54 rated design) built-in heat exchange included harmonic filter optimized for generator supply wide supply input 360 to 528 V, fully covers 440V ±20% advanced lamp ignition for low temperatures lamp distance up to 100m highest power density designed according to MEPC174(58) 6 kw and 8 kw GL approved Type Lamp Power Lamp Voltage Dimensions See ELC X6B-60 6 kw 600 V Appendix A ELC X8B-80 8 kw 800 V Appendix A ELC X12B-110 12 kw 1100 V Appendix A ELC X24B-210 24 kw 2100 V Appendix A ELC X36B-300* 36 kw 3000 V Appendix A *under development

ELC P and PE series Based on the successful analogn series, the P series offers a smart digital field bus control combined with highest power density in a compact and efficient design. The field bus control enables in-field diagnostics, and significantly reduces wiring. Type 400 V version Type 480 V version Lamp Power Lamp Voltage Dimensions See ELC P10-400-80 on request 10 kw 800V Appendix D ELC PE12-400-110 on request 12 kw 1100V Appendix B ELC PE16-400-140 on request 16 kw 1400V Appendix B ELC PE22-400-210 on request 22 kw 2100V Appendix C ELC PE32-400-280 on request 32 kw 2800V Appendix C Technical Sheet Mains voltage 400 V ± 10%, 3 phase, 50/60 Hz Power factor P type: typ. 0.93, PE type: typ. 0.90 Efficiency P type: typ. 96%, PE type: typ. 94% Harmonic current P type: 33%, PE type: typ. 36% * distortion THDi Control port PROFIBUS Safety interrupt yes Lamp dimming 20% to 100% range Lamp monitoring voltage, current, power Earth fault detection standard Max. distance ELC 15 to 40m (depending on ELC type) to lamp Protection IP20 Max. ambient 40 C to 50 C (depending on ELC type) temperature Cooling forced air cooling Dimensions see table above Weight typ. 15 kg to 37 kg Approvals CE, EN 50 178 * PE type requires additional mains choke UK = 4% Data subject to technical alterations

Appendix A: ELC X series ELC X4 ELC X4 ELC X8, X12

Appendix A: ELC X series ELC X16, X24 ELC X36

Appendix B: ELC PE12, PE16 261 mm Lufteintritt air entrance Steckerleiste für Steuersignale control connector Oben top 540 mm 501 mm 650 mm 263,5 mm min. 150 31 mm 200 mm 31 mm min. 150 Netzanschluß line input Luftaustritt air exhaust Lampenstecker lampconnection

Appendix C: ELC PE22, PE32 261 mm Steckerleiste für Steuersignale control connector Lufteintritt air entrance Oben top 540 mm 501 mm 650 mm min. 150 484 mm Lufteintritt air entrance 31 mm 200 mm 31 mm min. 150 Luftaustritt air exhaust Netzanschluß line input Luftaustritt air exhaust Lampenstecker lampconnection

Appendix D: ELC P10 min. 20 pin-and-socket connector for control signals min. 50 min. 100 top Side-by-side rack mounting (see manual for further information) 473 mm 539 mm 520 mm min. 100 23 mm 80 mm M8 (4x) Back mounting (see manual for further information) 130 mm Lamp feeder connection mains connection 321 mm eta plus electronic gmbh Lauterstraße 29, 72622 Nürtingen, Telefon +49 7022 6002-80, Fax +49 7022 65854, E-mail: info@eta-uv.de, www.eta-uv.de