Shock Tube Saver System Installation and Operation Manual Duke Part No Rev. B

Similar documents
1.0 Installation Wiring

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Bendix BlindSpotter Side Object Detection System. Installation Guide

Page 1 of 9. Pyromate Mini 96 Firing System

COOKSON OWNER'S MANUAL

User s Manual. Automatic Switch-Mode Battery Charger

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

SafeStart hand held SafeStart Initiators (SI-1)

Asynchronous Restriking CDI 2 channel

Application note. The APM-AMP meter can be connected in three different configurations:

3 Phase Smart Controller

Electric Trolling Motor

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

MODEL 2001 HERMETI-CHECK OPERATING INSTRUCTIONS

BL7000 SYSTEM OPERATING MANUAL

E*Star Seismic Detonators. Electronic Programmable Detonators.

High Frequency SineWave Guardian TM

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

INSTRUCTION MANUAL AUTO CHARGE MODEL # OUTPUT: 15 AMPERES 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Contents. DX Ignition Page 2

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

SSX-180ST. SolarMaxx 180 Illuminator Service Manual

HI-POT/CONTINUITY TESTER Model PLEP01

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

Work safely. Stowing The Digger. Digging

Product Manual (Revision C) Original Instructions. Air/Fuel Ratio Control. Installation and Operation Manual

4000 SYSTEM OPERATING MANUAL

Battery Power Inverters

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Switching DC Power Supply

Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL

C1219 C1219-STEERING ANGLE SENSOR ERRATIC PERFORMANCE RAM Pickup 6.7L Eng Search. 7/13/2015 Printer Friendly View

essentia audiotoo s User Manual Rev 2.0 September 2015 Mains Multiplier 5 Mains Multiplier 7 Mains Multiplier 8

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

GEMINI CONTROL FOR B SERIES KILN

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

INTEGRATED1500LB WINCH KIT

ST Charger. Industrial Battery Charger

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

A. Welding Control Module. 2. Control Models WC.12RO & WC.24RO -- Location of Internal Indicators and Fuses

User s Manual Rev 1.3 GME

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

RP Instruction Manual

CDBR-B. Instruction Manual. Dynamic Braking Unit. March 2013 Part Number: R4 Copyright 2013 Magnetek

Model: OBD-L On-Board-Diagnostics II Memory Saver Detector

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

FACT SHEET Standard: Electrical Safety

GFM-40ac COMPLIANCE WESTUSA. Ground Circuit Tester. Instruction Manual

60V RECHARGEABLE LITHIUM-ION BATTERY

EVS RP6020. Instruction Manual

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

How to bias: MTS3200, MTS3212 Rev A 8/1/2008 carvinservice.com

55185 EMERGENCY PACK FOR LED PANEL TECHNICAL DATA SHEET

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

with lcd display 12-42v

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

Table 3. Pumping Range. 6 in cm. 8 in cm. 16 in cm. 6 in cm. 14 in cm. 18 in cm.

AviStart 4000 Owner s Manual -FRONT COVER

SSX-300ST SolarMaxx 300 Illuminator

PHOENIX HV Features of the Phoenix HV-45 : 2.3 Connecting the Motor. 2.4 Reversing Rotation. 2.5 Connecting the Receiver

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

XP800i POWER INVERTER OWNER S MANUAL

MotorGuard. KMG High Performance Output Sine Wave Filter. Installation, Operation, and Maintenance Manual

GFM-200A. Instruction Manual

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

SAFETY PRECAUTIONS AND WARNINGS...

Boston Gear Ratiotrol DC Motor Speed Control

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK

HT-25kVdc Dielectric Withstand Tester Volts DC Output

SONIC SENTINEL MODEL 14-1

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Installation instruction

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems

MASTERsine Inverter PXA Series Installation Guide

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

User s Manual. Model MDS-30. User s Manual. A Portable Actuator for Remotely Operating Cutler Hammer Magnum DS Breakers.

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Harness the Power of the Sun

AGV5-1, AGV5-2 FORM AGV5 OM 11-02

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

Page 2. Pitot tube anti-ice. Windshield Anti-ice Components. Propeller Anti-ice Components. Wing boot anti-ice pneumatic components

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

WF-5110R True Sine Wave Inverter

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer

Battery powered ignition

P.A. System Installation Manual

Biasing the Vintage Series (Nomad, BelAir, VT50, Vintage 33)

Installation and Maintenance Manual

SEC. SEC America, LLC. Model 7048 DC-DC Converter Rev 1 Owner's Manual

Transcription:

Shock Tube Saver System Installation and Operation Manual Duke Part No. 515800 Rev. B INTRODUCTION The Duke Pro Shock Tube Saver System (STSS) shock tube initiator is designed to provide a substitute for long strands of shock tube and provide a reliable means of shock tube initiation, thus saving the user money and allowing the reduction of up to 95% of shock tube usage per shot. It typically pays for itself in 25 shots. The shock tube initiator has been safety tested by the U.S. Military for safety, accidental firing, and electromagnetic compatibility. Operating radios, radar, and static discharges near the unit will not cause it to fire. It has passed all tests related to these safety requirements. DANGER!!! NEVER look into the tip when firing the shock tube tip. Material may be ejected from the tip during firing and lodge in the users eye. DANGER!!! Potentially lethal voltages exist on the output terminals of the shock tube initiator when firing. Do not insert any object other than an approved Duke Pro switch tip into the output terminals. DANGER!!! Do not attempt to fire electric blasting caps using the initiator or power pack. This system was designed to ignite shock tube only. NOTICE: This equipment is intended for use only by properly licensed and professionally trained personnel. Duke Pro, Inc. and its employees are not responsible for any damages or monetary losses whatsoever, whether anticipated or real, resulting from the use or misuse of this equipment. The user of this equipment must determine the suitability of this product in conjunction with any other product to make the determination whether it is safe to use in a particular application. Aborting a Shot If the user wishes to abort the shot they simply release the charge button on the power pack and the down range unit safely discharges the stored energy internally and goes into a safe standby mode. Firing the unit requires a continual application of DC power for 2~3 seconds. SETUP The STSS (Shock Tube Saver System) is composed of 5 parts: 1.) The downrange initiator 2.) The 500' lead line reel 3.) The 27 volt power pack 4.) Banana plug quick connect plugs 5.) Shorting plug for cable reel up range banana plug connector Two quick connect banana plug adapters are supplied for attachment to the wire. This allows rapid attachment of the lead line to the down range initiator, a shorting plug, and the 27 volt power pack. The power pack contains three nine volt batteries in series with a battery voltage level monitor circuit. The output remains shunted until the fire button is depressed. When the fire button is depressed, the shunt is removed from the output and power is applied to the output terminals and the LED power output indicator. When the output voltage falls below 22 volts the LED will no longer illuminate and the user should replace the batteries. The battery's voltage will be equal to 22VDC / 3 or 7.33 volts each. Page 1 of 6 515800 Rev B

The down range initiator unit is an automatic charge/fire system for initiating shock tube. It uses a nominal 220 milliamps of current at 15 volts input to charge the energy storage capacitors to a nominal voltage of 2,500 volts over a two second period. When the capacitors are charged the energy is then applied to the shock tube initiator tip. If power is removed from the unit, before firing, it will automatically go into a standby mode and safely discharge the high voltage capacitors. Do not insert anything other than a Duke Pro switch tip into the output banana jacks of the initiator. It is not designed to initiate electric blasting caps. Lead Line Lengths: The 500 of lead line that is supplied with the STSS is 20 AWG duplex wire. 20 AWG wire has a resistance of approximately 10.0 ohms per thousand feet, and 500 feet of duplex wire has two 500 foot conductors. The shock tube initiator requires 0.22 amps, so one can expect a voltage drop of : Vdrop= 0.22 A 10.0 =2.2V The minimum input voltage to the shock tube initiator is 15 V. Maximum lead line lengths can be calculate based on know resistances per foot of various wire sizes and the battery voltage. These are provided in table form (Table 1) and in chart form (Illustration 1) below. Battery Voltage Gauge 27 25 23 21 19 17 16 AWG 6792 5660 4528 3396 2264 1132 18 AWG 4271 3560 2848 2136 1424 712 20 AWG 2686 2239 1791 1343 895 448 22 AWG 1689 1408 1126 845 563 282 24 AWG 1062 885 708 531 354 177 26 AWG 668 557 445 334 223 111 28 AWG 420 350 280 210 140 70 Table 1: Table of Lead Line Lengths 27 25 Battery Voltage 23 21 19 17 16 AWG 18 AWG 20 AWG 22 AWG 24 AWG 26 AWG 28 AWG 15 100 1000 10000 Maximum Lead Line Length Illustration 1: Chart of Lead Line Length vs. Battery Voltage and Wire Gauge

Setup for a shot: Never place a shot under high power wires, the duplex wires can be blown into the high voltage lines and cause serious injury or death by electrocution! Always do a quick test shot, dry firing the unit, using the downrange initiator, cable reel, and power pack. 1.) Test the unit. Without any shock tube connected to the initiator, close the handle on the switch tip and insert the tip into the shock tube initiator. Connect the shock tube initiator to the spool of wire, and the power pack to the other end of the spool. Make sure the shorting plug assembly is disconnected. Using the power pack depress and hold the power pack charge button for 3 seconds. The shock tube initiator should fire. If it does not, follow the tip calibration procedures and check the battery level lamp when power is applied. 2.) Disconnect the power pack and connect the shorting plug to the up range connector on the reel of wire, and disconnect the down range connector from the shock tube initiator. Never leave the power pack up range unsecured as a general safety precaution. 3.) Go down range with the power pack, the initiator, and the spool of wire. 4.) Remove the switch tip from the initiator, load the tip with shock tube and close the cross piercing lever on the shock tube tip (red dot exposed). Make sure the shorting plug is installed on the uprange connector of the spool of wire before connecting the spool of wire. Once the shorting plug is installed, connect the downrange connector on the spool of wire to the shock tube initiator. 5.) Install the switch tip into the shock tube initiator. Pay out the line while walking up range to a safe distance * to ensure you are safe from fly rock, avalanche hazards, and ballistic events caused by primary and secondary explosions, overpressure, and shock waves. 6.) Once up range and after you have given the proper safety warnings of the impending shot, scour the surrounding area for any signs of people or animals trespassing into the blast zone. 7.) Make your last safety call and sound your safety horn or siren (shout out fire in the hole three times and in three different directions, listen carefully for 30 seconds while observing for any persons or animals straying into the blast zone). Give a final blast of your safety siren or horn and listen. If no response is heard or witnessed then proceed to the next step. 8.) Connect the up range plug to the power pack, then remove the shorting plug. (The lead line wires will be shorted internally by the power pack until the fire button is depressed.) 9.) To fire the shot, press and hold the fire button for three seconds. Observe that the battery level lamp is on. Ignition of the shock tube down range should occur within 2 to 3 seconds. 10.)After releasing the fire button, reinstall the shorting plug into the uprange connector and disconnect the wire reel from the power pack. Walk toward the down range initiator while winding the duplex wire on the reel. If you have any questions or comments please don t hesitate to call us at the number listed below. TOLL FREE: 1-866-587-3853 or 1-TOOL-UP-DUKE * ISEE Table of distances is based on explosives placed in the ground. Above ground detonations of explosives is extremely hazardous due to the ability of the explosives to propel objects to ballistic velocities, create lethal over pressure, and generate shock waves and air blasts, which can travel for many miles and do extensive damage to property and cause great personnel harm. Page 3 of 6 515800 Rev B

SPECIFICATIONS INITIATOR Input Voltage: 17 ~ 27 volts D.C. Firing Voltage: 2,500 Volts D.C. + 3% -0% Charge Time: 2 seconds nominal Firing Sequence: Charge time 2 seconds followed automatically 5 milliseconds later by fire relay cycle, the unit then goes into low current standby until power is removed. Nominal Current: 0.220 amps @ 27 VDC Tip Life: 10,000 shots typical Dimensions: 5.7 L x 3.5 W x 2.25 H Weight: 1.2 lbs Operating Temperature: -40 F ~ 185 F Storage Temperature: -40 F ~ 185 F Relative Humidity: 0 ~ 95% NON-CONDENSING POWER PACK Output Voltage: 22 ~ 27 volts D.C. Nominal Current: 0.220 amps @ 27 VDC Dimensions: 6.0 L x 3.3 W x 2.0 H Weight: 0.4 lbs Operating Temperature: Storage Temperature: -40 F ~ 185 F 0 F ~ 120 F (alkaline battery operational temperature limitation) Relative Humidity: 0 ~ 95% NON-CONDENSING

Shock Tube Saver System Components Shorting plug assembly Power pack Downrange Initiator Page 5 of 6 515800 Rev B

ESI Tip Operating Instructions and Calibration Procedure www.dukepro.com Asheville, North Carolina 866-587-3853 STEP ONE PLACE CROSS-PIERCING ELECTRODE CONTROL LEVER IN THE SAFE POSITION (AWAY FROM SHOCK TUBE HOLE) STEP TWO PUSH SHOCK TUBE THROUGH THE LOADING HOLE UNTIL THE CENTER ELECTRODE IS INSIDE OF THE SHOCK TUBE. DO NOT TWIST THE SHOCK TUBE WHILE INSERTING OR REMOVING. STEP THREE MOVE THE CONTROL ARM LEVER TO THE FIRE POSITION. SHOCK TUBE FIRE SAFE *** IMPORTANT *** ALWAYS MOVE PIERCING CONTROL ARM LEVER TO SAFE POSITION BEFORE REMOVING SHOCK TUBE CALIBRATION PROCEDURE: 1. MOVE CONTROL HANDLE TO SAFE POSITION. 2. BACK OFF ADJUSTMENT SCREW 3 OR 4 TURNS. 3. MOVE CONTROL HANDLE TO FIRE POSITION. 4. INSPECT THE POSITION OF THE CROSS-PIERCING ELECTRODE. WHEN LOOKING FROM THE SIDE, THE CROSS-PIERCING ELECTRODE SHOULD BE STRAIGHT AND NOT HAVE AN UP OR DOWN TILT. WHEN LOOKING FROM THE TOP, IT SHOULD PASS DIRECTLY OVER THE CENTER ELECTRODE. 5. SCREW CENTER ELECTRODE IN UNTIL IT TOUCHES CROSS-PIERCING ELECTRODE. TIP: AN OHM METER CONNECTED TO BANANA PLUGS CAN BE USED TO DETECT ELECTRODE CONTACT. 6. BACK OFF 1/3-1/2 TURN COUNTER- CLOCKWISE. 7. TEST UNIT. 8. BACK OFF CENTER ELECTRODE AS NECESSARY TO PREVENT PREMATURE ARCING. CROSS-PIERCING ELECTRODE (MUST GO STRAIGHT ACROSS AND NOT BE BENT UP OR DOWN) CENTER ELECTRODE ADJUSTMENT SCREW CENTER ELECTRODE