All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

Similar documents
All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

UniGear. Technical Guide

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

with Vacuum Circuit Breaker HAF

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Metal Clad Air Insulated Switchgear

Air-insulated switchgear UniGear type ZS1

Instruction for Installation and Operation

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

ZX2 Gas-insulated medium voltage switchgear

Gas Insulated Metal-clad Switchgear, HMGS!

PIX-H Metal-clad switchgear up to 17.5kV

ZX2.2 Gas-insulated medium voltage switchgear

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

CBGS-0. Medium voltage distribution

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Power IT Air Insulated Cubicle Uniswitch

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

Metal Clad Switchgears

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

MESG 12 / 17.5 / 24 / 36 KV

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Benefits, typical uses

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

CPG.0 Single busbar gas-insulated cubicles

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

with Vacuum Circuit Breaker HAF

UniSafe 36. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

Product Specification

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

PIX High. Medium-voltage switchgear. Air-insulated switchgear kv ( 50 ka) Assembly - Operation - Maintenance Technical Manual

e n e r g i a HULANICKI BEDNAREK sp. z o.o. HABeR-M Switchgear system rated up to 1600A 1

MNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems

Content. Uniswitch. 1. Design philosophy Applications Switchgear construction Cubicle types... 9

Valid for you. medium voltage switchgear

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

MCSG 12kV / A

33KV INDOOR SWITCHGEAR

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

NXPLUS C Single busbar. Maintenance-free for lifetime

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

METAL-CLAD SWITCHGEAR TYPE SRUP 12, SRP kv A...25 ka. Manual for mounting, operation and maintenance. ABB Power Distribution

Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Ed rev.0 CATALOGUE SWITCHGEAR 2015

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

ZX-Family Gas-insulated medium voltage switchgear

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR


SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

MCset 4-24 kv Withdrawable SF6 circuit breaker

the safe, reliable, and efficient choice for MV switchgear

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Air-insulated switchgear with

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

vertical fuse switch disconnectors

UniSec Operation and maintenance manual

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

PC3.0/MNS R 690 V A Main low voltage distribution switchgear

VD4 Installation and service instructions kv A ka

TECHNICAL MANUAL AND APPLICATION GUIDE. Engineering Your Power

EMPAC Metal enclosed capacitor bank for wind applications

Cable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples.

For your safety! Foreword

B kv T&D GAS INSULATED SWITCHGEAR

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Fuse switch disconnectors

Contents. We build a better future! MCC HCB

Transcription:

Issued: January 2013 Copyright by ZPUE Katowice S.A. All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected. Remark: Due to constant technical advancement the manufacturer reserves rights for the implementation of technical changes without any notice. Authors of this document kindly request Users for submitting their remarks on errors, deficiencies or any inconsistency noticed in this document on email address office@elektromontaz1.pl.

MEDIUM VOLTAGE SWITCHGEAR 36kV IN A METAL ENCLOSURE, WITHDRAWABLE, CUBICLE TYPE RXD 36 Technical catalogue Katowice, January 2013

Contents page 1. Introduction.....6 2. Switchgear description...6 Types of fields Technical data 3. Switchgear construction...8 Structure Busbars Earthing protectin Cable connections Interlocking and protection against improper operations 4. Switchgear equipment...10 Switching equipment Measuring equipment Protection equipment 5. Main circuit, auxiliary circuit diagrams and switchgear automation...10 6. Switchgear packaging, transport and installation...11 7. Equipment delivered with the switchgear...12 8. Figures...12 9. Data sheets...17 5

1. Introduction The catalogue presents RXD 36 medium voltage switchgears: - with air insulation, - in metal enclosures, - withdrawable, cubicle type, - with a single busbar system, - nominal voltage 36kV, - adapted for interior installation. 2. Switchgear description The RXD 36 switchgear is intended for operation in distribution stations of companies that produce, transmit and use electric energy. The device complies with the requirements of the standards (IEC) PN-EN 62271-200 and (IEC) PN-EN 62271-1 and it ensures the IP4X degree of protection for external shields according to (IEC) PN-EN 60529. The switchgear is suitable for operation under normal conditions defined by the standard (IEC) PN-EN 62271-1 for interior distribution and control equipment. The switchgear was designed so as to ensure safe normal operation, inspection and service. The switchgear structure is made of hot-dip galvanized steel sheets. The doors are covered with a powder coat of grey colour (RAL 7032) or another colour, upon the customer s order. Types of fields The switchgears may be composed of panels with various functions, such as for instance: - incoming/outgoing panels, - coupler panels (section connector), - measurement panels, - and panels for own needs. The withdrawable unit may be equipped with a circuit-breaker, bridge or set of voltage transformers with fuses. It can assume the following positions: connected, test/disconnected and removed (beyond the panel). Interlocks are used for the withdrawable unit with the circuit-breaker that make it possible to perform switching activities only in the working and test positions. The withdrawable unit can be slid in or out into working position only when the circuit-breaker is open. The RXD 36 is characterised by a high level of operating safety, obtained by the following means: - arc-proof construction: the switchgear complies with all the requirements laid down by the standard, - external shield with IP4X degree of protection, - outlets with exhaust flaps that reduce pressure increase if an internal arc fault occurs inside the enclosure, - connecting interlocks and door locks. 6

Advantages of the switchgear: 1) high protection rating obtained by the following means: - high resistance of the metal enclosure to internal arc impact, - locking of the switching activities: earthing switch / circuit-breaker, - possibility of inspecting switching activities visually through the sight glasses, - signalling of voltage in the panels, - door lock depending on the earthing switch position, - moving the mobile part from test to working position and vice versa, when the panel door is closed, 2) simple and light frameless structure made of galvanized steel sheets, with relatively, small enclosure dimensions, while keeping very high parameters, 3) very easy access to installation spaces, 4) optimum utilisation of installation space, 5) modern switching equipment used. BASIC TECHNICAL DATA OF RXD 36 SWITCHGEARS Rated voltage 36 Rated normal current of main busbars and supply panel [A] 630 / 1250 Rated power frequency Rated lightning impulse to earth and between phases across the isolating distance to earth and between phases across the isolating distance Rated frequency [Hz] 50 85 (5min) / 95 (1min) 120 (5 min.) 190 (1.2/50µs) 220 (1.2/50µs) Rated short-time withstand current [ka/1s] 25 Rated peak withstand current [ka] 63 Withstand for internal arcing fault [ka/1s] 20 Degree of protection IP4X Height of panel [mm] 2 600 Width of panel [mm] 1 600 Depth of panel [mm] 1 888 Conformity with standards (IEC) PN-EN 62271-200, (IEC) PN-EN 62271-1 GOST 1516.3-1996 The switchgear is suitable for operation under normal conditions defined by the standard (IEC) PN-EN 62271-1 for interior distribution and control equipment. According to the standard, the limit environmental conditions for switchgear operation are the following: - maximum altitude above sea level up to 1000 m. - ambient temperature: - maximum temperature +40ºС - average temperature over 24h +35ºС - minimum temperature -5ºС - maximum relative humidity 95% - atmosphere: normal, non-corrosive and unpolluted 7

3. Switchgear construction Structure The switchgear is a cubicle type device in an enclosure, made of riveted sheet metal shaped by bending. The walls with apparatus brackets create a self-supporting structure. The enclosure contains a separate auxiliary circuit compartment. Vent flaps. There are outlets in the upper part of the enclosure closed by exhaust flaps. Their task is to discharge the pressure created inside the compartment as a result of an internal arc fault. A sudden increase of pressure inside the switchgear causes the plastic screws to break and the flaps to open by deflection. The busbars are located in the upper part of the enclosure. The busbars pass between the enclosures through gland plates. This prevents damage from spreading to adjacent enclosures if an internal arc fault occurs. The gland plates made of insulation material are fitted with grommet insulators supporting the busbars. Outflow bars branch off from the busbars. The main connector is installed on the withdrawable unit. The withdrawable unit in working position and in test/disconnection position is located inside the enclosure, behind a closed door. After opening the door, it can be rolled out to separation position. In the back part of the enclosure there are brackets for installing additional equipment for main circuits. The auxiliary circuit compartment, i.e. a separate cabinet installed in the upper front part of the switchgear front panel is used to install protection units, inspection, measurement and control equipment and automation elements. There is a series of openings in the enclosure walls for cable trays, as well as grommets for cables and wires. The openings are covered by plates in which holes can be made if necessary. A perforated installation plate was designed for equipment installation, placed at the back wall of the enclosure. The equipment may also be installed on the side walls. Busbars The busbars in the switchgear include a single, three-phase busduct with phases in horizontal tandem layout. The busbars rest on grommet insulators built into the side walls and on support insulators mounted to the enclosure roof. The busducts are made of flat copper busbars with rounded edges with the following sections: for 630A current for 1250A current 40x10 R5 mm, 2x(40x10 R5 mm). 8

Earthing protection There is an earthing conductor in each enclosure (a copper bus with 40x5 mm section) located at the bottom, on the back of the enclosure. These conductors between the enclosures are connected by bridges forming an earthing bus conductor. The bus conductor ends with terminals on the right and left hand side of the switchgear used to connect it to the facility s earthing system. Cable connections The panel bottom is suitable for connecting single or multi conductor cables with plastic insulation. We recommend cable fittings manufactured by Tyco Electronics (Raychem), a company whose products we distribute. Interlocking and protection against improper operations The RXD 36 switchgear is equipped with mechanical and electrical interlocks. Mechanical interlocks: 1) making it impossible to slide in or out the withdrawable unit into the working position when the circuit-breaker is closed (required by the standard), 2) allowing the circuit-breaker to be opened or closed only in connected and the test/disconnected positions (required by the standard), 3) allowing the earthing switch to be closed only in test/disconnected or removed position of the withdrawable unit, 4) not allowing the withdrawable unit to be shifted from the test/disconnected position into the connected position if the earthing switch is closed. After obtaining the approval of the switchgear manufacturer, it is also possible to use padlocks. Electrical interlocks: 1) allowing the circuit-breaker to be activated only if its auxiliary circuits are supplied (required by the standard), 2) making it impossible to open the panel door when the earthing switch is open. After obtaining the approval of the switchgear manufacturer the device may be fitted with additional interlocks whose operation is based on miniature switches and electromagnetic locks. 9

4. Switchgear equipment Switching equipment The switchgear is also equipped in the standard version with 3AH SIEMENS vacuum circuit-breakers and optionally with VD4 or HD4 circuit breakers from ABB. Other equipment may be used after obtaining the switchgear manufacturer s consent (unit with load break switch / disconnector). Measuring equipment CTS and VTS transformers from KPB Intra are used for measurement. Voltage in the incoming panels is signalled by reactance insulators and a voltage indicator. Protection equipment Low voltage equipment from any manufacturer may be built into the switchgear, according to the customer s individual needs. It is possible to install any digital relay to protect the medium voltage circuits. There is a possibility to install the arc protection systems in the switchgear. The suggested arc protection systems are ZŁ or VAMP. The systems sense if there is a short-circuit with their flash detection and current or voltage criterion inside the protected switchgear. If both events are simultaneous, the system is activated and a pulse is sent within a defined time (below 10 ms) releasing the main switch. 5. Main circuit, auxiliary circuit diagrams and switchgear automation Main circuits The structural diagrams of main circuits for standard panel types are shown in figure 2 and in the relevant catalogue sheets that can be found in this catalogue and on the website www.katowice.zpue.pl. Auxiliary circuits The low voltage auxiliary circuits include: protection, measurement, control, automation control and signalling systems. The auxiliary system cabinet is intended for equipment in these circuits, located in the upper front part of the switchgear. The cabinet dimensions are shown in figure 3. In order to obtain examples of internal and installation connection diagrams for main and auxiliary devices for typical switchgear equipment, please contact the switchgear manufacturer. Switchgear automation The switchgear is suitable for operation in an integrated control, display and data collection system. For this purpose, it is fitted with digital protection relays (with the possibility of digital communication) and with power engineering automation control units. The switchgear may then operate in superior and automatic control systems. 10

6. Switchgear packaging, transport and installation Packaging Three types of packaging are used for the RXD 36 switchgear: a) standard: the switchgear enclosure placed on a pallet is wrapped in air bubble film and then in stretch film, b) crates: the switchgears packaged as above are placed in crates, c) especially for maritime transport: the switchgears with a moisture absorbing agent placed inside are packed into bags made of film with preservation properties, from which air is sucked out. Switchgears preserved in this manner are transported on pallets or in crates. Transport As a standard, switchgear enclosures are transported individually. Switchgears may be transported to the room they are intended for and moved within that room using a crane, fork lift truck or on rollers. The enclosure is fitted with transport grips for crane lifting. The bend angle of fastening ropes should not exceed 120. It is forbidden to fasten the ropes directly to the enclosure structure. The enclosure is placed on a transport pallet in order to make transport with a fork lift truck possible. During switchgear transport and placement caution should be exercised so as not to damage the coating and the protective sheet metal. Principal equipment such as circuit-breakers, contactors and withdrawable units and low voltage equipment sensitive to shock are transported separately in original packaging supplied by the manufacturers. Switchgear installation Foundation and external connections The switchgear foundation and the external cable and busbar connections depend on the construction of the plant in which the switchgear is going to be placed. They should be made taking into account all the guidelines included in figure 4 and 5 and obtained additionally by arrangement with the switchgear manufacturer. Switchgears are transported to the customer as individual enclosures and assembled at the place of installation. Figure 5 shows switchgear minimal distance from switching room walls. It is advised that dimension Y of the switchgear room should be at least 1000 mm greater than the overall width of the switchgear due to installation technique. They can be mounted: directly on the floor, on a foundation frame fixed to the floor or on the steel or concrete structure in the facility. Independently of the substrate, the switchgears have to be placed horizontally and fastened. 11

7. Equipment delivered with the switchgear The following equipment accompanies each switchgear: - fasteners for connecting the transport sets, - crank for moving the withdrawable unit, - crank for the earthing switch drive, - keys to the enclosure door. Documents delivered with the switchgear: - declaration of conformity, - switchgear operating manual, - operation and maintenance manuals and warranty cards for the equipment used, - switchgear as-built documentation, - warranty certificate. 8. Figures List of figures: Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Panel equipment. Main circuit structural diagrams. Auxiliary circuit cabinet. Fixing the switchgear to the base. Placing the switchgear in the room. 12

Figure 1 Panel equipment 1 - connecting busbars, 2 - main device: circuit breaker, 3 - earthing switch, 4 - current transformers, 5 - voltage transformers, 6 - support insulators (reactance), 7 - bushing insulators, 8 - surge arresters, 9 - protection devices, 10 - earthing busbar. 13

Incoming panel with cable connection Coupling panel double cubicle Figure 2. Main circuit structural diagrams Measurement panel with earthing of main busbars Measurement panel with earthing of main busbars Panel with disconnector 14

Mounting place available on the door Mounting plates Figure 3. Auxiliary circuit cabinet 15

area for pass the cables Figure 4. Fixing the switchgear to the base Figure 5. Placing the switchgear in the room Remark: In case of specific demands resulting in changing dimensions, please contact the manufacturer of switchgears. 16

9. Data sheets List of the data sheets included in this catalogue * RXD 36 up to 36kV Page: 1. Sheet 1-1 Ed.1301 Incoming/outgoing panel with circuit-breaker 630A 18 2. Sheet 1-2 Ed.1301 Incoming/outgoing panel with circuit-breaker 630A 19 3. Sheet 1-3 Ed.1301 Incoming/outgoing panel with 630A/1250A disconnector 20 4. Sheet 1-4 Ed.1301 Incoming/outgoing panel with disconnector and circuit-breaker 630A 21 5. Sheet 1-5 Ed.1301 Incoming/outgoing panel with 630A load break switch 22 6. Sheet 1-6 Ed.1301 Incoming/outgoing panel with circuit-breaker 630A/1250A 23 7. Sheet 2-1 Ed.1301 Coupler panel enclosure with circuit-breaker (up to 630A) 24 8. Sheet 2-2 Ed.1301 Coupler panel enclosure with bridge (up to 630A) 25 9. Sheet 3-1 Ed.1301 Measurement panel withdrawable unit with voltage transformers 26 10. Sheet 3-2 Ed.1301 Measurement panel 27 11. Sheet 4-1 Ed.1301 Own needs panel with transformer (up to 100kVA; 35/0.4kV) 28 * - data sheets relevant to switchgears with technical parameters and panel configurations that are different from the ones included in the table are available directly from the manufacturer or from the website www.katowice.zpue.pl. 17

ZPUE Katowice S.A. RXD 36 Incoming/outgoing panel with circuit-breaker sheet 1-1 Ed. 1301 Structural diagram (Diagram S1-9) Enclosure section Front view (Facade E3-160-1 ) Rated voltage 36 Rated power frequency to earth and between phases across the isolating distance 85 (5min) / 95 (1min) 120 (5min) Rated lightning impulse to earth and between phases 190 (1.2/50µs) across the isolating distance 220 (1.2/50µs) Rated frequency [Hz] 50 Rated normal current [A] 630 Rated normal current of main busbars [A] 630 Rated short-time withstand current [ka/1s] 25 Rated peak withstand current [ka] 63 Withstand for internal arcing fault [ka/1s] 20 Degree of protection IP4X Electrical equipment: Circuit breaker Q1 3AH (SIEMENS) Current transformer T1 CTS38 Earthing switch Q3 UW36 Weigh [kg] 1300 Dimensions (HxWxD) [mm] 2600 x 1600 x 1888 Arrangement / access to the switchgear back-to-wall / only front access Attention: Configuration of equipment (type/producer) of panel and its functionality could be agreed with producer 18

ZPUE Katowice S.A. RXD 36 Incoming/outgoing panel with circuit-breaker sheet 1-2 Ed. 1301 Structural diagram (Diagram S1-10) Enclosure section Front view (Facade E3-160-1) Rated voltage 36 Rated power frequency to earth and between phases across the isolating distance 85 (5min) / 95 (1min) 120 (5min) Rated lightning impulse to earth and between phases 190 (1.2/50µs) across the isolating distance 220 (1.2/50µs) Rated frequency [Hz] 50 Rated normal current [A] 630 Rated normal current of main busbars [A] 630 Rated short-time withstand current [ka/1s] 25 Rated peak withstand current [ka] 63 Withstand for internal arcing fault [ka/1s] 20 Degree of protection IP4X Electrical equipment: Circuit breaker Q1 3AH (SIEMENS) Current transformer T1 CTS38 Surge arrester F1 GXE51 (ABB) Earthing switch Q3 UW36 Weigh [kg] 1300 Dimensions (HxWxD) [mm] 2600 x 1600 x 1888 Arrangement / access to the switchgear back-to-wall / only front access Attention: Configuration of equipment (type/producer) of panel and its functionality could be agreed with producer 19

ZPUE Katowice S.A. RXD 36 Incoming/outgoing panel with disconnector sheet 1-3 Ed. 1301 Structural diagram (Diagram S1-11) Enclosure section Front view (Facade E3-160-2) Rated voltage 36 Rated power frequency to earth and between phases across the isolating distance 85 (5min) / 95 (1min) 120 (5min) Rated lightning impulse to earth and between phases 190 (1.2/50µs) across the isolating distance 220 (1.2/50µs) Rated frequency [Hz] 50 Rated normal current [A] 630, 1250 Rated normal current of main busbars [A] 1250 Rated short-time withstand current [ka/1s] 25 Rated peak withstand current [ka] 63 Withstand for internal arcing fault [ka/1s] 20 Degree of protection IP4X Electrical equipment: Disconnector Q2 OW III-30 (ABB) Current transformer T1 CTS38 Voltage transformer T2 VTS38 Weigh [kg] 1300 Dimensions (HxWxD) [mm] 2600 x 1600 x 1888 Arrangement / access to the switchgear back-to-wall / only front access Attention: Configuration of equipment (type/producer) of panel and its functionality could be agreed with producer 20

ZPUE Katowice S.A. RXD 36 Incoming/outgoing panel with disconnector and circuit-breaker sheet 1-4 Ed. 1301 Structural diagram (Diagram S1-12) Enclosure section Front view (Facade E3-160-3) Rated voltage 36 Rated power frequency to earth and between phases across the isolating distance 85 (5min) / 95 (1min) 120 (5min) Rated lightning impulse to earth and between phases 190 (1.2/50µs) across the isolating distance 220 (1.2/50µs) Rated frequency [Hz] 50 Rated normal current [A] 630 Rated normal current of main busbars [A] 630 Rated short-time withstand current [ka/1s] 25 Rated peak withstand current [ka] 63 Withstand for internal arcing fault [ka/1s] 20 Degree of protection IP4X Electrical equipment: Circuit breaker Q1 3AH (SIEMENS) Currrent transformer T1 CTS38 Disconnector Q2 OW III-30 (ABB) Earthing switch Q3 UW36 Weigh [kg] 1300 Dimensions (HxWxD) [mm] 2600 x 1600 x 1888 Arrangement / access to the switchgear back-to-wall / only front access Attention: Configuration of equipment (type/producer) of panel and its functionality could be agreed with producer 21

ZPUE Katowice S.A. RXD 36 Incoming/outgoing panel with load break switch sheet 1-5 Ed. 1301 Structural diagram (Diagram S1-13) Enclosure section Front view (Facade E3-160-4) Rated voltage 36 Rated power frequency to earth and between phases across the isolating distance 85 (5min) / 95 (1min) 120 (5min) Rated lightning impulse to earth and between phases 190 (1.2/50µs) across the isolating distance 220 (1.2/50µs) Rated frequency [Hz] 50 Rated normal current [A] 630 Rated normal current of main busbars [A] 630 Rated short-time withstand current [ka/1s] 25 Rated peak withstand current [ka] 63 Withstand for internal arcing fault [ka/1s] 20 Degree of protection IP4X Electrical equipment: Load break switch Q2 NAL 36 (ABB) Current transformer T1 CTS38 Surge arrester F1 GXE 51 (ABB) Earthing switch Q3 UW36 Weigh [kg] 1150 Dimensions (HxWxD) [mm] 2600 x 1600 x 1888 Arrangement / access to the switchgear back-to-wall / only front access Attention: Configuration of equipment (type/producer) of panel and its functionality could be agreed with producer 22

ZPUE Katowice S.A. RXD 36 Incoming/outgoing panel with circuit-breaker sheet 1-6 Ed. 1301 Structural diagram (Diagram S1-14) Enclosure section Front view (Facade E3-160-1) Rated voltage 36 Rated power frequency to earth and between phases across the isolating distance 85 (5min) / 95 (1min) 120 (5min) Rated lightning impulse to earth and between phases 190 (1.2/50µs) across the isolating distance 220 (1.2/50µs) Rated frequency [Hz] 50 Rated normal current [A] 630, 1250 Rated normal current of main busbars [A] 1250 Rated short-time withstand current [ka/1s] 25 Rated peak withstand current [ka] 63 Withstand for internal arcing fault [ka/1s] 20 Degree of protection IP4X Electrical equipment: Circuit breaker Q1 3AH (SIEMENS) Current transformer T1 CTS38 Voltage transformer T2 VTS38 Surge arrester F1 GXE51 (ABB) Earthing switch Q3 UW36 Weigh [kg] 1380 Dimensions (HxWxD) [mm] 2600 x 1600 x 1888 Arrangement / access to the switchgear back-to-wall / only front access Attention: Configuration of equipment (type/producer) of panel and its functionality could be agreed with producer 23

ZPUE Katowice S.A. RXD 36 Coupler panel enclosure with circuit-breaker sheet 2-1 Ed. 1301 Structural diagram (Diagram S2-1) Enclosure section Front view (Facade E3-160-5) Rated voltage 36 Rated power frequency to earth and between phases across the isolating distance 85 (5min) / 95 (1min) 120 (5min) Rated lightning impulse to earth and between phases 190 (1.2/50µs) across the isolating distance 220 (1.2/50µs) Rated frequency [Hz] 50 Rated normal current [A] 630 Rated normal current of main busbars [A] 630 Rated short-time withstand current [ka/1s] 25 Rated peak withstand current [ka] 63 Withstand for internal arcing fault [ka/1s] 20 Degree of protection IP4X Electrical equipment: Circuit breaker Q1 3AH (SIEMENS) Current transformer T1 CTS38 Weigh [kg] 1300 Dimensions (HxWxD) [mm] 2600 x 1600 x 1888 Arrangement / access to the switchgear back-to-wall / only front access Attention: Configuration of equipment (type/producer) of panel and its functionality could be agreed with producer 24

ZPUE Katowice S.A. RXD 36 Coupler panel enclosure with bridge sheet 2-2 Ed. 1301 Structural diagram (Diagram S2-2) Enclosure section Front view (Facade E3-160-6) Rated voltage 36 Rated power frequency to earth and between phases across the isolating distance 85 (5min) / 95 (1min) 120 (5min) Rated lightning impulse to earth and between phases 190 (1.2/50µs) across the isolating distance 220 (1.2/50µs) Rated frequency [Hz] 50 Rated normal current [A] 630 Rated normal current of main busbars [A] 630 Rated short-time withstand current [ka/1s] 25 Rated peak withstand current [ka] 63 Withstand for internal arcing fault [ka/1s] 20 Degree of protection IP4X Electrical equipment: Bridge Q4 produced by ZPUE Katowice S.A. Weigh [kg] 1150 Dimensions (HxWxD) [mm] 2600 x 1600 x 1888 Arrangement / access to the switchgear back-to-wall / only front access Attention: Configuration of equipment (type/producer) of panel and its functionality could be agreed with producer 25

ZPUE Katowice S.A. RXD 36 Measurement panel withdrawable unit with voltage transformers sheet 3-1 Ed. 1301 Structural diagram (Diagram S3-6) Enclosure section Front view (Facade E3-160-6) Rated voltage 36 Rated power frequency to earth and between phases 85 (5min) / 95 (1min) across the isolating distance 120 (5min) Rated lightning impulse to earth and between phases 190 (1.2/50µs) across the isolating distance 220 (1.2/50µs) Rated frequency [Hz] 50 Rated normal current of main busbars [A] 630 Rated short-time withstand current [ka/1s] 25 Rated peak withstand current [ka] 63 Withstand for internal arcing fault [ka/1s] 20 Degree of protection IP4X Electrical equipment: Movement unit Withdrawable unit with voltage transformers Voltage transformer T2 VTS38 Earthing switch Q3 UW36 Weigh [kg] 1100 Dimensions (HxWxD) [mm] 2600 x 1600 x 1888 Arrangement / access to the switchgear back-to-wall / only front access Attention: Configuration of equipment (type/producer) of panel and its functionality could be agreed with producer 26

ZPUE Katowice S.A. RXD 36 Measurement panel sheet 3-2 Ed. 1301 Structural diagram (Diagram S3-7) Enclosure section Front view (Facade E3-160-2) Rated voltage 36 Rated power frequency to earth and between phases across the isolating distance 85 (5min) / 95 (1min) 120 (5min) Rated lightning impulse to earth and between phases 190 (1.2/50µs) across the isolating distance 220 (1.2/50µs) Rated frequency [Hz] 50 Rated normal current of main busbars [A] 630 Rated short-time withstand current [ka/1s] 25 Rated peak withstand current [ka] 63 Withstand for internal arcing fault [ka/1s] 20 Degree of protection IP4X Electrical equipment: Voltage transformer T2 VTS38 Earthing switch Q3 UW36 Weigh [kg] 1100 Dimensions (HxWxD) [mm] 2600 x 1600 x 1888 Arrangement / access to the switchgear back-to-wall / only front access Attention: Configuration of equipment (type/producer) of panel and its functionality could be agreed with produce 27

ZPUE Katowice S.A. RXD 36 Own needs panel sheet 4-1 Ed. 1301 Structural diagram (Diagram S4-3) Enclosure section Front view (Facade E3-200-1) Rated voltage 36 Rated power frequency to earth and between phases across the isolating distance 85 (5min) / 95 (1min) 120 (5min) Rated lightning impulse to earth and between phases 190 (1.2/50µs) across the isolating distance 220 (1.2/50µs) Rated frequency [Hz] 50 Rated normal current of main busbars [A] 630 Rated short-time withstand current [ka/1s] 25 Rated peak withstand current [ka] 63 Withstand for internal arcing fault [ka/1s] 20 Degree of protection IP4X Electrical equipment: Transformer T up to 100kVA; 35/0.4kV Disconnector Q2 ON (ABB) Fuses F BWMW 3.15A Weigh [kg] 2070 Dimensions (HxWxD) [mm] 2600 x 2000 x 1888 Arrangement / access to the switchgear back-to-wall / only front access Attention: Configuration of equipment (type/producer) of panel and its functionality could be agreed with producer 28

Catalogue RXD 36 / EN, Issued: January 2013