PowerCube type PB. Pre-assembled modules and enclosures for constructing medium voltage switchgear

Similar documents
PowerCube type PB series A complete solution for OEMs

Air-insulated switchgear UniGear type ZS1

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

HD4. Gas insulated MV circuit-breakers kv A ka

HD4. Gas insulated MV circuit-breakers kv A ka

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

UniSafe 36. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

VD4 Installation and service instructions kv A ka

HD4. Gas insulated MV circuit-breakers kv A ka

Vmax Medium voltage vacuum circuit-breakers. IEC: kv; A; ka ANSI: kv; A; ka

VD4/R. Medium Voltage vacuum circuit-breakers for secondary distribution

Metal Clad Switchgears

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

VD4. Installation and service instructions kv A ka

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

MESG 12 / 17.5 / 24 / 36 KV

Medium Voltage Products. SHS2 Gas-insulated switching and isolating apparatus

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

UniGear. Technical Guide

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Medium voltage indoor circuit breakers ANSI/IEC solutions

UniGear type ZS1. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

PIX-H Metal-clad switchgear up to 17.5kV

UniSec Operation and maintenance manual

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

with Vacuum Circuit Breaker HAF

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Gas Insulated Metal-clad Switchgear, HMGS!

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

PC3.0/MNS R 690 V A Main low voltage distribution switchgear

CPG.0 Single busbar gas-insulated cubicles

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

EMPAC Metal enclosed capacitor bank for wind applications

Current accuracy class. Sensor principles

Medium voltage products HD4/R - HD4/RE MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

Unitole UP kv Primary substations Motor control centres

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

DISTRIBUTION SOLUTIONS HA Breaker Retrofit. Medium Voltage Service Marketing and Sales

PT Guna Era Manufaktura. Catalogue GAE TPS \ Medium Voltage Switchgear 12kV - 24kV \ M GAE TPS. Medium Voltage Switchgear 12kV - 24kV

UniSafe 36 Product Presentation. ABB Elektrik Sanayi A.S. - Page 1

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

NXPLUS C Single busbar. Maintenance-free for lifetime

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

Power IT Air Insulated Cubicle Uniswitch

Unitole UP kv Primary substations Motor control centres

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

VD4/R - VD4/L - VD4/UniAir - VD4/UniMix

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Extensible Unit - VCE2a

Unified requirements for systems with voltages above 1 kv up to 15 kv

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Metal Clad Air Insulated Switchgear

Vacuum Circuit Breaker

VD4 Installation and service instructions 36 kv A ka

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

Medium Voltage Metal-Enclosed Switches

ABB AG - Calor Emag Medium Voltage Products OEM Products Medium Voltage Products. ABB OEM Products 1

Metal Clad VCBs ~ Mk1

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

OHB Outdoor sulphur Hexafluoride circuit-breaker

Medium Voltage Products. VD4 Medium voltage vacuum circuit-breaker 12 kv A - 63 ka 36/40.5 kv A ka

3TM Vacuum Contactors

MCSG 12kV / A

the safe, reliable, and efficient choice for MV switchgear

33KV INDOOR SWITCHGEAR

CP Automatic capacitor bank

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

HD4 Installation and service instructions kv A ka

Contactor V-Contact VSC/P

GAE MCC Modular-C. Catalogue Standardized Motor Control Centres. PT Guna Era Manufaktura

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

B kv Gas-insulated Substations

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

TGI Vacuum Circuit-Breaker Air isolator Earthing switch

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

DPX moulded case circuit breakers

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Medium Voltage Metal-Enclosed Switches

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

UniSec Maintenance solutions

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

Transcription:

PowerCube type PB Pre-assembled modules and enclosures for constructing medium voltage switchgear

GENERAL CHARACTERISTICS MAIN COMPONENTS TYPES AVAILABLE AND APPARATUS OVERALL DIMENSIONS AND WEIGHTS ELECTRIC CIRCUIT DIAGRAM COMPLETION OF THE SWITCHGEAR 2 6 12 22 24 30 1 2 3 4 5 6 1

1 GENERAL CHARACTERISTICS PowerCube type PB/M Module. General The PowerCube modules allow construction of metal-clad medium voltage air-insulated switchgear with the same rated currents as those of the enclosure. In fact, the rated currents of the enclosures refer to versions tested in ABB UniSafe type switchgear. In particular, the 4000 A PB3 enclosure means it is possible to construct switchgear with the same rated current as long as a suitable fan is applied in the back of the switchgear (for further information, please ask ABB). The PB type PowerCubes are available in two different versions: PB/M and PB/E. PB/M: complete module including the cable access compartment which can also be prepared to house the withdrawable VT compartment. PB/E: compounded enclosure with the cable access compartment and therefore without the possibility of housing the withdrawable VT compartment, but, thanks to its smaller overall dimensions, more flexible and suited to developing double-level switchgear. The PowerCube modules are pre-assembled and factory-tested and comply with IEC 62271-200, CEI 17-1, IEC 60694 and CEI 17-6 Standards. They are available with the following characteristics: Rated voltage (kv)... 17.5 24 Rated current (A)... 4000... 2500 Rated short-time main circuit... 40 x 3s... 31.5 x 3s withstand current (ka)... 50 x 1s The following apparatus can be installed in the PowerCube modules: VD4, VM1, evm1 and Vmax series vacuum circuit-breakers HD4 series gas circuit-breakers V-Contact series vacuum contactors service trucks. All the operations of the apparatus are carried out from the front of the module/enclosure. Degrees of protection The degrees of protection of the PowerCube modules comply with the IEC 60529 Standards. The following standard degrees of protection are guaranteed on the front: external housing: IP4X inside the units: IP2X. 2 PowerCube type PB/M enclosure.

Interlocks The PowerCube module is fitted with the interlocks needed to prevent incorrect operations which might jeopardise safety of the personnel in charge of running the installation, as well as the efficiency and reliability of the apparatus. In particular, locking devices to prevent the following operations are provided: circuit-breaker closing in the intermediate position racking-out of closed circuit-breaker racking-in of closed circuit-breaker circuit-breaker compartment door opening in the connected or intermediate position circuit-breaker racking-in with compartment door open. And, if the unit is fitted with an earthing switch: earthing switch closing with the circuit-breaker in the connected or intermediate position racking-in the circuit-breaker with the earthing switch closed feeder compartment door opening with the earthing switch open (only for PowerCube PB/M module) earthing switch opening with the feeder compartment door open (only for PowerCube PB/M module). Note: some of the interlocks listed above are supplied on request or are only available for some versions. Quality System Complies with ISO 9001 Standards, certified by an independent external organisation. Test laboratory Complies with ISO 45001 Standards, accredited by an independent external organisation. Environmental Management System Complies with ISO 14001 Standards, certified by an independent external organisation. Health and Safety Management System Complies with OHSAS 18001 Standards, certified by an independent external organisation. 3

1 GENERAL CHARACTERISTICS 4 5 A Circuit-breaker compartment 1 Voltage signalling device (on request only for PowerCube PB/M module) 2 Circuit-breaker/contactor/truck 3 Metal shutters 4 Lower and upper monoblocs 5 Earthing switch (on request) 6 Door 7 Fan (only for 3600 A and 4000 A PB3 and for 2500 A PB5) B Feeder compartment 8 VT compartment (on request only for PowerCube PB/M module) 9 Door 1 2 3 6 8 A 9 7 B 4

Electrical characteristics of PowerCube modules PowerCube Module/Enclosure PB1 PB2 PB3 PB4 PB5 PB1/R PB2/R PB3/R PB4/R PB5/R Module width mm 600 750 1000 750 1000 600 750 1000 750 1000 Rated voltage 12 kv 17.5 kv 24 kv Test voltage 28 kv at industrial frequency 38 kv 50 kv Impulse withstand 75 kv voltage 95 kv 125 kv Short-time 25 ka (3s) withstand current 31.5 ka (3s) (2) (2) 40 ka (3s) 50 ka (1s) Peak current 63 ka 79 ka 100 ka 125 ka NOT APPLICABLE Rated currents 630 A 1250 A 1600 A 2000 A 2500 A (1) 3150 A 3600 A (1) 4000 A (1) Electrical characteristics of earthing switch (on request) PowerCube Module/Enclosure PB1 PB2 PB3 PB4 PB5 PB1/R PB2/R PB3/R PB4/R PB5/R Module width mm 600 750 1000 750 1000 600 750 1000 750 1000 Short-time 25 ka (3s) withstand current / 31.5 ka (3s) (2) (2) (2) (2) Short-circuit 40 ka (1s) making capacity 50 ka (1s) Peak current 63 ka 79 ka 100 ka 125 ka (1) With forced ventilation of the circuit-breaker compartment: for 4000 A, an additional fan is required in the back of the switchgear. (2) Ask ABB - Available for PB/E enclosure; not available for PB/M enclosure. 5

2 MAIN COMPONENTS Circuit-breakers The PowerCube units can be fitted with HD4 series SF6 withdrawable and VD4, VM1, evm1 and evmax series vacuum circuit-breakers. The circuit-breakers are fitted with a truck which allows their racking-in and out of the switchgear with the door closed. Both types have a compact and light structure which ensures great sturdiness and excellent mechanical reliability. The operating mechanism and poles are fixed to the metal structure which also acts as a support for the moving contact actuation kinematics. HD4 series gas circuit-breaker. HD4 series SF6 Circuit-breakers The HD4 series of medium voltage circuit-breakers use sulphur hexafluoride gas (SF6) to extinguish the electric arc and as the insulating medium. The breaking principle of HD4 circuit-breakers is based on compression and self-blast techniques to obtain top performances at all service current values, with gradual arc extinction, no restriking, operating overvoltages or chopped currents. These characteristics guarantee long electrical life for the circuit-breaker and limited dynamic, dielectric and thermal stresses on the installation. The circuit-breaker poles, which make up the interruption part, are sealed for life pressure systems (IEC 62271-100 and CEI 17.1 Standards) and are maintenance-free. The stored energy mechanical operating mechanism has free trip and allows opening and closing operations independent of the operator s actions. VD4 series vacuum circuit-breaker. evm1 series vacuum circuit-breaker. VD4, VM1 and evm1 series vacuum circuit-breakers The VD4, VM1 and evm1 circuit-breakers use vacuum as the interruption and insulating medium. Thanks to the advanced techniques used for their construction, the vacuum circuit-breakers ensure high performances under all service conditions. The vacuum interrupters are embedded in the poles made of epoxy resin. This construction means the interrupters are unaffected by shocks, humidity and environmental pollution. The circuit-breaker poles, making up the interruption part, are sealed for life pressure systems (IEC 62271-100 and CEI 17.1 Standards) and are maintenance-free. The VD4 circuit-breakers use a mechanical type of operating mechanism, the VM1 and evm1 circuit-breakers use an operating mechanism with a magnetic actuator. They are both stored energy operating mechanisms with free trip and allow opening and closing operations independent of the operator s actions. The evm1 circuit-breakers are also fitted with an integrated measurement and protection system which can be configured by means of a personal computer, directly by the customer using some simple software. 6

Vmax/W series vacuum circuit-breakers Vmax circuit-breakers are made up of an insulating monobloc in which three vacuum interrupters are fixed. The monobloc and the operating mechanism are fixed to a frame. The vacuum interrupters house the contacts and make up the interruption chambers of the circuit-breaker. Vmax circuit-breakers use a mechanical stored energy operating mechanism with free trip which allows opening and closing operations independent of the operator s actions. The mechanical operating mechanism is of simple concept and use and can be personalised with a wide range of easily and rapidly installed accessories. This simplicity characterised the apparatus for its reliability, duration and limited maintenance. Vmax circuit-breakers are used in power distribution for control and protection of cables, overhead lines, transformer and distribution substations, motors, transformers, generators and capacitor banks. The circuit-breaker vacuum interrupters, which make up the interruption part, are sealed for life pressure systems (IEC 62271-100 and CEI 17.1 Standards) and are maintenance-free. Vmax/W series vacuum circuit-breaker. V-Contact V/P and V-Contact VSC/P series vacuum contactors Use of V-Contact series withdrawable contactors is foreseen in the PB1 PowerCube units up to 12 kv. The contactors are suitable for controlling alternating current users which require a high number of operations. They consist of a resin monobloc where the vacuum interrupters, moving equipment, operating mechanism, multivoltage feeder and auxiliary accessories are housed. The monobloc is also the support for installation of the fuses. Fuses according to DIN or BS Standards of different dimensions can be used thanks to special adapters. The type of fuseholder (BS or DIN) must be specified when ordering. Contactor closing is prevented when even a single fuse is missing. Opening is automatic when one of the three fuses blows. They are of compact and sturdy construction and guarantee very long electrical and mechanical life. V-Contact series vacuum contactors VSC/P and V/P. 7

2 MAIN COMPONENTS During the racking-in phase, the power cable earthing truck only actuates the bottom shutter and earths the contacts connected to the bottom branch connections (and therefore to the power cables) by means of the switchgear structure. These trucks can be used in incoming or outgoing units or in dedicated units. They can also be used in bus-tie units. In this case, they earth one of the two sides of the main busbar system. Service trucks The PowerCube range is equipped with all the service trucks needed to complete the switchgear and required for service operations and during maintenance work. The trucks are divided into four different types: earthing without making capacity. earthing with making capacity. cable testing. isolation. Note: the earthing trucks with making and isolation capacity are available derived from the HD4 series only. Earthing truck without making capacity E These trucks carry out the same function as the earthing switches without making capacity. They therefore have no capacity to earth live circuits in fault conditions. They are used to ensure an additional fixed earth, as is required by the installation service and maintenance procedures, as a further guarantee for personnel. The use of these trucks foresees removal of the switching apparatus from the switchgear (circuitbreaker or contactor) and its replacement with the truck. The units preset for use of the earthing trucks can be provided with a key lock which, when activated, prevents their racking-in. This truck is available in two versions: earthing of the main busbar system (E/U series). earthing of the power cables (E/L series). During the racking-in phase, the main busbar earthing truck only actuates the top shutter and earths the contacts connected to the top branch connections (and therefore to the main busbar system) by means of the switchgear structure. Earthing truck with making capacity EM These trucks carry out the same function as the earthing switches with making capacity. They consist of circuit-breakers only fitted with top (main busbar earthing) or bottom (power cable earthing) terminals. The contacts without terminals are short-circuited by means of a copper bar and connected to earth by means of the apparatus truck. They keep all the characteristics of the circuitbreakers, such as full making capacity on live circuits under fault conditions. They allow closing operations to be carried out rapidly with remote electric control. The use of these trucks foresees removal of the switching apparatus from the switchgear (circuitbreaker or contactor) and its replacement with the truck. The units preset for use of the earthing trucks can be provided with a key lock which, when activated, prevents their racking-in. This truck is available in two versions: main busbar system earthing (EM/U series) power cable earthing (EM/L series). During the racking-in phase, the main busbar earthing truck only lifts the top shutter and prepares the contacts connected to the top branch connections (and therefore to the main busbar system) to close to earth by means of a control. During the racking-in phase, the power cable earthing truck only lifts the bottom shutter and prepares the contacts connected to the bottom branch connections (and therefore to the power cables) to close to earth by means of a control. These trucks can be used in incoming or outgoing units or in dedicated units. They can also be used in bus-tie units. In this case, they earth one of the two sides of the main busbar system. 8

Power cable testing truck T These trucks allow the insulation tests on the power cables to be carried out without accessing the feeder compartment or disconnecting the cables from the switchgear. The use of these trucks foresees removal of the switching apparatus from the switchgear (circuit-breaker or contactor) and its replacement with the truck. During the racking-in phase, the truck only lifts the bottom shutter and, by means of the connectors it is fitted with, allows connection of the test apparatus cables by means of a special insulating rod (testing apparatus and insulating rod must be provided by the customer). This truck can only be used in incoming/outgoing units. Isolating truck S The isolating truck allows the top switchgear contacts to be connected directly to the bottom ones. Connection is made extremely safe by using the poles of the circuit-breakers to insulate the connection busbars from the external environment. In the incoming/outgoing units, the isolating truck connects the main busbar system to the power cables, whereas in the bus-tie units, it connects the two sides of the busbar system. This truck has its application in switchgear for making incoming/outgoing units without a circuitbreaker in radial networks, for making cable connections between two switchgear placed in front of each other, in making interconnection units and in creating bus-tie-riser units with double isolation (in this case, both units are made up of bus-ties, the former fitted with a circuit-breaker and the latter with an isolating truck). The units preset for using isolating trucks are fitted with a key lock which, when activated, prevents their being racked-in. Main busbar system earthing truck, without making capacity. Power cable earthing truck, without making capacity. Cable testing truck. Main busbar system earthing truck, with making capacity. Power cable earthing truck, with making capacity. Isolating truck. 9

2 MAIN COMPONENTS Earthing switches The PB type PowerCube units can be fitted with an earthing switch. The earthing switch is fitted with making capacity on short-circuit. The opening and closing operations can be locked, on request, by means of key locks. Earthing switch control is carried out from the front of the module with manual operation suitably interlocked with the position of the circuit-breaker. For availability of the accessories, please see the table on page 21. Monoblocs and shutters The monoblocs consist of insulating bushings containing the power connections - top and bottom - of the circuit-breaker compartment, towards the feeder and busbar compartments respectively. The shutters are of the metal type and are activated automatically during movement of the circuit-breaker from the test/ isolated position to the connected position and vice versa. They can be fitted with a fail-safe safety device (optional) to prevent their manual opening with the circuit-breaker removed. Each shutter can be locked by means of two independent padlocks (optional). Metal segregation shutters. Insulating monoblocs (seen from the rear). 10

Earthing switch closed. Earthing switch open. Certain signalling of the earthing switch position (open/closed) visible from the front of the enclosure. VT Compartment (only PB/M units) The PowerCube modules can be fitted with a VT compartment with withdrawable voltage transformers. The voltage transformers are of the dedicated type and are protected by fuses. Fuse replacement can be carried out with the switchgear in service as the fuse compartment is segregated metallically from the other compartments. The VT compartment is available for PowerCube modules 750 mm and 1000 mm wide. For availability of the accessories, please see the table on page 21. VT compartment with withdrawable voltage transformers. 11

3 TYPES AVAILABLE AND APPARATUS Notes for using PowerCube type PB/E units To construct incoming, outgoing and bus-tie type switchgear units, selection of PB1... PB5 type PowerCube units is recommended (see Tables 1 to 8 on the following pages). To construct bus riser, measurement and direct busbar incoming switchgear units, selection of PR1... PR5 type PowerCube units is recommended (see Table 9 further on). Example of PB1... PB5 type PowerCube units (front and rear views). 1 2 Example of PR1... PR5 PowerCube units (front and rear views). 3 1. Monoblocs with contacts for rated current up to 2500 A. 2. Monoblocs with contacts for rated current up to 4000 A. 3. Fan. Pre-installed in the 3600 A PB3 and 2500 A PB5 units. For 4000 A PB3 it is necessary to install another fan in the back of the switchgear (by the customer). 12

Table 1 - VD4 withdrawable circuit-breakers for PowerCube type PB units (*) Rated current of the VD4 circuit-breakers (A - 40 C) kv Isc Icw W=600 W=750 W=750 W=1000 W=750 W=1000 Circuit-breaker PowerCube (ka) (ka) p=150 p=210 p=210 p=275 p=210 p=275 u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 u/l=310 H=260 H=280 H=280 H=280 H=325 H=345 ø=35 ø=35 ø=79 ø=109 ø=35 ø=79 12-17.5 16 16 630 VD4/P 12.06.16 p150 VD4/P 17.06.16 p150 PB 1/E 20 20 630 VD4/P 12.06.20 p150 VD4/P 17.06.20 p150 PB 1/M 630 VD4/P 12.06.25 p150 VD4/P 17.06.25 p150 31.5 31.5 630 VD4/P 12.06.32 p150 VD4/P 17.06.32 p150 16 16 1250 VD4/P 12.12.16 p150 VD4/P 17.12.16 p150 20 20 1250 VD4/P 12.12.20 p150 VD4/P 17.12.20 p150 1250 VD4/P 12.12.25 p150 VD4/P 17.12.25 p150 31.5 31.5 1250 VD4/P 12.12.32 p150 VD4/P 17.12.32 p150 16 16 630 VD4/W 12.06.16 p210 VD4/W 17.06.16 p210 PB 2/E 20 20 630 VD4/W 12.06.20 p210 VD4/W 17.06.20 p210 PB 2/M 630 VD4/W 12.06.25 p210 VD4/W 17.06.25 p210 31.5 31.5 630 VD4/W 12.06.32 p210 VD4/W 17.06.32 p210 16 16 1250 VD4/W 12.12.16 p210 VD4/W 17.12.16 p210 20 20 1250 VD4/W 12.12.20 p210 VD4/W 17.12.20 p210 1250 VD4/W 12.12.25 p210 VD4/W 17.12.25 p210 31.5 31.5 1250 VD4/W 12.12.32 p210 VD4/W 17.12.32 p210 40 40 1250 50 50 1250 40 40 1250 VD4/P 12.12.40 p210 VD4/P 17.12.40 p210 ( 3 ) 50 50 1250 VD4/P 12.12.50 p210 20 20 1600 VD4/P 12.16.20 p210 VD4/P 17.16.20 p210 1600 VD4/P 12.16.25 p210 VD4/P 17.16.25 p210 31.5 31.5 1600 VD4/P 12.16.32 p210 VD4/P 17.16.32 p210 40 40 1600 VD4/P 12.16.40 p210 ( 3 ) VD4/P 17.16.40 p210 ( 3 ) 50 50 1600 VD4/P 12.16.50 p210 ( 3 ) 20 20 2000 VD4/P 12.20.20 p210 VD4/P 17.20.20 p210 2000 VD4/P 12.20.25 p210 VD4/P 17.20.25 p210 31.5 31.5 2000 VD4/P 12.20.32 p210 VD4/P 17.20.32 p210 40 40 2000 VD4/P 12.20.40 p210 ( 3 ) VD4/P 17.20.40 p210 ( 3 ) 50 50 2000 VD4/P 12.20.50 p210 ( 3 ) 20 20 2500 VD4/P 12.25.20 p275 VD4/P 17.25.20 p275 PB 3/E 2500 VD4/P 12.25.25 p275 VD4/P 17.25.25 p275 PB 3/M 31.5 31.5 2500 VD4/P 12.25.32 p275 VD4/P 17.25.32 p275 40 40 2500 VD4/P 12.25.40 p275 ( 3 ) VD4/P 17.25.40 p275 ( 3 ) 50 50 2500 VD4/P 12.25.50 p275 ( 3 ) 31.5 31.5 3150 VD4/P 12.32.32 p275 ( 3 ) VD4/P 17.32.32 p275 ( 3 ) 40 40 3150 VD4/P 12.32.40 p275 ( 3 ) VD4/P 17.32.40 p275 ( 3 ) 50 50 3150 VD4/P 12.32.50 p275 ( 3 ) 31.5 31.5 3600 ( 1 ) VD4/P 12.32.32 p275 ( 3 ) VD4/P 17.32.32 p275 ( 3 ) 40 40 3600 ( 1 ) VD4/P 12.32.40 p275 ( 3 ) VD4/P 17.32.40 p275 ( 3 ) 50 50 3600 ( 1 ) VD4/P 12.32.50 p275 ( 3 ) 31.5 31.5 4000 ( 1 ) VD4/P 12.32.32 p275 ( 3 ) VD4/P 17.32.32 p275 ( 3 ) 40 40 4000 ( 1 ) VD4/P 12.32.40 p275 ( 3 ) VD4/P 17.32.40 p275 ( 3 ) 50 50 4000 ( 1 ) VD4/P 12.32.50 p275 ( 3 ) 24 16 16 630 VD4/P 24.06.16 p210 PB 4/E 20 20 630 VD4/P 24.06.20 p210 PB 4/M 630 VD4/P 24.06.25 p210 16 16 1250 VD4/P 24.12.16 p210 20 20 1250 VD4/P 24.12.20 p210 1250 VD4/P 24.12.25 p210 16 16 1600 VD4/P 24.16.16 p275 PB 5/E 20 20 1600 VD4/P 24.16.20 p275 PB 5/M 1600 VD4/P 24.16.25 p275 16 16 2000 VD4/P 24.20.16 p275 20 20 2000 VD4/P 24.20.20 p275 2000 VD4/P 24.20.25 p275 16 16 2500 ( 2 ) VD4/P 24.25.16 p275 20 20 2500 ( 2 ) VD4/P 24.25.20 p275 2500 ( 2 ) VD4/P 24.25.25 p275 W = Width of PowerCube unit. P = Horizontal centre distance between circuit-breaker poles. U/L = Distance between top and bottom terminal. H = Distance between bottom terminal and earth. Ø = Diameter of the contacts in the PowerCube unit monbloc. (*) The PowerCube units are not prepared for application of the motorised truck for VD4 circuit-breakers (1) 3600 A with fan pre-installed in the PB3 units. For 4000 A it is necessary to install another fan in the back of the switchgear (by the customer). (2) 2500 A with fan pre-installed in the PB5 units. (3) Please ask ABB for availability. 13

3 TYPES AVAILABLE AND APPARATUS Table 2 - Withdrawable HD4 circuit-breakers for PowerCube type PB units Rated current of the HD4 circuit-breakers (A - 40 C) kv Isc Icw W=600 W=750 W=750 W=1000 W=750 W=1000 Circuit-breaker PowerCube (ka) (ka) p=150 p=210 p=210 p=275 p=210 p=275 u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 u/l=310 H=260 H=280 H=280 H=280 H=325 H=345 ø=35 ø=35 ø=79 ø=109 ø=35 ø=79 12 16 16 630 HD4/W 12.06.16 p150 HD4/W 17.06.16 p150 PB 1/E 17.5 630 HD4/W 12.06.25 p150 HD4/W 17.06.25 p150 PB 1/M 31.5 31.5 630 HD4/W 12.06.32 p150 HD4/W 17.06.32 p150 16 16 1250 HD4/W 12.12.16 p150 HD4/W 17.12.16 p150 1250 HD4/W 12.12.25 p150 HD4/W 17.12.25 p150 31.5 31.5 1250 HD4/W 12.12.32 p150 HD4/W 17.12.32 p150 16 16 630 HD4/W 12.06.16 p210 HD4/W 17.06.16 p210 PB 2/E 630 HD4/W 12.06.25 p210 HD4/W 17.06.25 p210 PB 2/M 31.5 31.5 630 HD4/W 12.06.32 p210 HD4/W 17.06.32 p210 16 16 1250 HD4/W 12.12.16 p210 HD4/W 17.12.16 p210 1250 HD4/W 12.12.25 p210 HD4/W 17.12.25 p210 31.5 31.5 1250 HD4/W 12.12.32 p210 HD4/W 17.12.32 p210 40 40 1250 HD4/W 12.12.40 p210 HD4/W 17.12.40 p210 50 50 1250 HD4/W 12.12.50 p210 HD4/W 17.12.50 p210 40 40 1250 50 50 1250 16 16 1600 HD4/W 12.16.16 p210 HD4/W 17.16.16 p210 1600 HD4/W 12.16.25 p210 HD4/W 17.16.25 p210 31.5 31.5 1600 HD4/W 12.16.32 p210 HD4/W 17.16.32 p210 40 40 1600 HD4/P 12.16.40 p210 HD4/P 17.16.40 p210 50 50 1600 HD4/P 12.16.50 p210 HD4/P 17.16.50 p210 16 16 2000 HD4/W 12.20.16 p210 HD4/W 17.20.16 p210 2000 HD4/W 12.20.25 p210 HD4/W 17.20.25 p210 31.5 31.5 2000 HD4/W 12.20.32 p210 HD4/W 17.20.32 p210 40 40 2000 HD4/P 12.20.40 p210 HD4/P 17.20.40 p210 50 50 2000 HD4/P 12.20.50 p210 HD4/P 17.20.50 p210 2500 HD4/P 12.25.25 p275 HD4/P 17.25.25 p275 PB 3/E 31.5 31.5 2500 HD4/P 12.25.32 p275 HD4/P 17.25.32 p275 PB 3/M 40 40 2500 HD4/P 12.25.40 p275 HD4/P 17.25.40 p275 50 50 2500 HD4/P 12.25.50 p275 HD4/P 17.25.50 p275 31.5 31.5 3150 HD4/W 12.32.32 p275 HD4/W 17.32.32 p275 40 40 3150 HD4/W 12.32.40 p275 HD4/W 17.32.40 p275 50 50 3150 HD4/W 12.32.50 p275 HD4/W 17.32.50 p275 31.5 31.5 3600 ( 1 ) HD4/W 12.32.32 p275 HD4/W 17.32.32 p275 40 40 3600 ( 1 ) HD4/W 12.32.40 p275 HD4/W 17.32.40 p275 50 50 3600 ( 1 ) HD4/W 12.32.50 p275 HD4/W 17.32.50 p275 31.5 31.5 4000 ( 1 ) HD4/W 12.32.32 p275 HD4/W 17.32.32 p275 40 40 4000 ( 1 ) HD4/W 12.32.40 p275 HD4/W 17.32.40 p275 50 50 4000 ( 1 ) HD4/W 12.32.50 p275 HD4/W 17.32.50 p275 24 16 16 630 HD4/W 24.06.16 p210 PB 4/E 20 20 630 HD4/W 24.06.20 p210 PB 4/M 630 HD4/W 24.06.25 p210 16 16 1250 HD4/W 24.12.16 p210 20 20 1250 HD4/W 24.12.20 p210 1250 HD4/W 24.12.25 p210 31.5 31.5 1250 ( 3 ) HD4/P 24.12.32 p275 16 16 1600 HD4/P 24.16.16 p275 PB 5/E 20 20 1600 HD4/P 24.16.20 p275 PB 5/M 1600 HD4/P 24.16.25 p275 31.5 31.5 1600 ( 3 ) HD4/P 24.16.32 p275 16 16 2000 HD4/P 24.20.16 p275 20 20 2000 HD4/P 24.20.20 p275 2000 HD4/P 24.20.25 p275 31.5 31.5 2000 ( 3 ) HD4/P 24.20.32 p275 16 16 2500 ( 2 ) HD4/P 24.25.16 p275 20 20 2500 ( 2 ) HD4/P 24.25.20 p275 2500 ( 2 ) HD4/P 24.25.25 p275 31.5 31.5 2500 ( 2 )( 3 ) HD4/P 24.25.32 p275 W = Width of PowerCube unit. P = Horizontal centre distance between circuit-breaker poles. U/L = Distance between top and bottom terminal. H = Distance between bottom terminal and earth. Ø = Diameter of the contacts in the PowerCube unit monbloc. (1) 3600 A with fan pre-installed in the PB3 modules. For 4000 A it is necessary to install another fan in the back of the switchgear (by the customer). (2) 2500 A with fan pre-installed in the PB5 modules. (3) Please ask ABB for availability. Not available for PB/M. 14

Table 3 - Withdrawable VM1 circuit-breakers for PowerCube type PB units Rated current of the VM1 circuit-breakers (A - 40 C) kv Isc Icw W=600 W=750 W=750 W=1000 W=750 W=1000 Circuit-breaker PowerCube (ka) (ka) p=150 p=210 p=210 p=275 p=210 p=275 u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 u/l=310 H=260 H=280 H=280 H=280 H=325 H=345 ø=35 ø=35 ø=79 ø=109 ø=35 ø=79 12 16 16 630 VM1/P 12.06.16 p150 VM1/P 17.06.16 p150 PB 1/E 17.5 20 20 630 VM1/P 12.06.20 p150 VM1/P 17.06.20 p150 PB 1/M 630 VM1/P 12.06.25 p150 VM1/P 17.06.25 p150 31.5 31.5 630 VM1/P 12.06.32 p150 VM1/P 17.06.32 p150 16 16 1250 VM1/P 12.12.16 p150 VM1/P 17.12.16 p150 20 20 1250 VM1/P 12.12.20 p150 VM1/P 17.12.20 p150 1250 VM1/P 12.12.25 p150 VM1/P 17.12.25 p150 31.5 31.5 1250 VM1/P 12.12.32 p150 VM1/P 17.12.32 p150 16 16 630 VM1/W 12.06.16 p210 VM1/W 17.06.16 p210 PB 2/E 20 20 630 VM1/W 12.06.20 p210 VM1/W 17.06.20 p210 PB 2/M 630 VM1/W 12.06.25 p210 VM1/W 17.06.25 p210 31.5 31.5 630 VM1/W 12.06.32 p210 VM1/W 17.06.32 p210 16 16 1250 VM1/W 12.12.16 p210 VM1/W 17.12.16 p210 20 20 1250 VM1/W 12.12.20 p210 VM1/W 17.12.20 p210 1250 VM1/W 12.12.25 p210 VM1/W 17.12.25 p210 31.5 31.5 1250 VM1/W 12.12.32 p210 VM1/W 17.12.32 p210 40 40 1250 50 50 1250 40 40 1250 50 50 1250 20 20 1600 VM1/P 12.16.20 p210 VM1/P 17.16.20 p210 1600 VM1/P 12.16.25 p210 VM1/P 17.16.25 p210 31.5 31.5 1600 VM1/P 12.16.32 p210 VM1/P 17.16.32 p210 40 40 1600 50 50 1600 20 20 2000 VM1/P 12.20.20 p210 VM1/P 17.20.20 p210 2000 VM1/P 12.20.25 p210 VM1/P 17.20.25 p210 31.5 31.5 2000 VM1/P 12.20.32 p210 VM1/P 17.20.32 p210 40 40 2000 50 50 2000 20 20 2500 VM1/P 12.25.20 p275 VM1/P 17.25.20 p275 PB 3/E 2500 VM1/P 12.25.25 p275 VM1/P 17.25.25 p275 PB 3/M 31.5 31.5 2500 VM1/P 12.25.32 p275 VM1/P 17.25.32 p275 40 40 2500 50 50 2500 31.5 31.5 3150 40 40 3150 50 50 3150 31.5 31.5 3600 ( 1 ) 40 40 3600 ( 1 ) 50 50 3600 ( 1 ) 31.5 31.5 4000 ( 1 ) 40 40 4000 ( 1 ) 50 50 4000 ( 1 ) 24 16 16 630 VM1/P 24.06.16 p210 PB 4/E 20 20 630 VM1/P 24.06.20 p210 PB 4/M 630 VM1/P 24.06.25 p210 16 16 1250 VM1/P 24.12.16 p210 20 20 1250 VM1/P 24.12.20 p210 1250 VM1/P 24.12.25 p210 16 16 1600 VM1/P 24.16.16 p275 PB 5/E 20 20 1600 VM1/P 24.16.20 p275 PB 5/M 1600 VM1/P 24.16.25 p275 16 16 2000 VM1/P 24.20.16 p275 20 20 2000 VM1/P 24.20.20 p275 2000 VM1/P 24.20.25 p275 16 16 2500 ( 2 ) VM1/P 24.25.16 p275 ( 3 ) 20 20 2500 ( 2 ) VM1/P 24.25.20 p275 ( 3 ) 2500 ( 2 ) VM1/P 24.25.25 p275 ( 3 ) W = Width of PowerCube unit. P = Horizontal centre distance between circuit-breaker poles. U/L = Distance between top and bottom terminal. H = Distance between bottom terminal and earth. Ø = Diameter of the contacts in the PowerCube unit monobloc. (1) 3600 A with fan pre-installed in the PB3 modules. For 4000 A it is necessary to install another fan in the back of the switchgear (by the customer). (2) 2500 A with fan pre-installed in the PB5 modules. (3) Please ask ABB for availability. 15

3 TYPES AVAILABLE AND APPARATUS Table 4 - Withdrawable evm1 circuit-breakers for PowerCube type PB units Rated current of the evm1 circuit-breakers inserted in the PowerCube units (40 C) [A] Withdrawable evm1 for PowerCube unit kv Isc Icw W=600 W=750 W=750 W=1000 W=750 W=1000 Circuit-breaker type Circuit-breaker type PowerCube ka) (ka) p=150 p=210 p=210 p=275 p=210 p=275 3s u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 u/l=310 H=260 H=280 H=280 H=280 H=325 H=345 ø=35 ø=35 ø=79 ø=109 ø=35 ø=79 16 16 630 evm1/p 12.06.16 p150 evm1/p 17.06.16 p150 PB1/E 20 20 630 evm1/p 12.06.20 p150 evm1/p 17.06.20 p150 PB1/M 630 evm1/p 12.06.25 p150 evm1/p 17.06.25 p150 31.5 31.5 630 evm1/p 12.06.32 p150 evm1/p 17.06.32 p150 16 16 1250 evm1/p 12.12.16 p150 evm1/p 17.12.16 p150 20 20 1250 evm1/p 12.12.20 p150 evm1/p 17.12.20 p150 1250 evm1/p 12.12.25 p150 evm1/p 17.12.25 p150 31.5 31.5 1250 evm1/p 12.12.32 p150 evm1/p 17.12.32 p150 Table 5 - Withdrawable Vmax circuit-breakers for PowerCube type PB units Rated current of the circuit-breakers Vmax inserted in the Withdrawable Vmax for PowerCube units PowerCube units (40 C) [A] kv Isc Icw W=600 W=750 W=750 W=1000 W=750 W=1000 Circuit-breaker type Circuit-breaker type PowerCube (ka) (ka) p=150 p=210 p=210 p=275 p=210 p=275 3s u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 u/l=310 H=260 H=280 H=280 H=280 H=325 H=345 ø=35 ø=35 ø=79 ø=109 ø=35 ø=79 16 16 630 Vmax/W 12.06.16 p150 Vmax/W 17.06.16 p150 * PB1/E 20 20 630 Vmax/W 12.06.20 p150 Vmax/W 17.06.20 p150 * PB1/M 630 Vmax/W 12.06.25 p150 Vmax/W 17.06.25 p150 * 31.5 31.5 630 Vmax/W 12.06.32 p150 Vmax/W 17.06.32 p150 * 16 16 1250 Vmax/W 12.12.16 p150 Vmax/W 17.12.16 p150 * 20 20 1250 Vmax/W 12.12.20 p150 Vmax/W 17.12.20 p150 * 1250 Vmax/W 12.12.25 p150 Vmax/W 17.12.25 p150 * 31.5 31.5 1250 Vmax/W 12.12.32 p150 Vmax/W 17.12.32 p150 * W = Width of PowerCube unit. P = Horizontal centre distance between circuit-breaker poles. U/L = Distance between top and bottom terminal. H = Distance between bottom terminal and earth. Ø = Diameter of the contacts in the PowerCube unit monobloc. * Please contact us for availability. 16

Table 6 - V-Contact withdrawable contactors for PowerCube type PB units Rated current of the V-Contact contactors (A - 40 C) kv Isc Icw W=600 W=750 W=750 W=1000 W=750 W=1000 Contactor PowerCube (ka) (ka) p=150 p=210 p=210 p=275 p=210 p=275 ( 3 ) u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 u/l=310 H=260 H=280 H=280 H=280 H=325 H=345 ø=35 ø=35 ø=79 ø=109 ø=35 ø=79 7.2 16 6 400 ( 4 ) V7/W PB 1/E 20 6 400 ( 4 ) VSC7/P PB 1/M 25 6 400 ( 4 ) 31.5 6 400 ( 4 ) 12 16 6 400 ( 4 ) V12/W 20 6 400 ( 4 ) VSC12/P 25 6 400 ( 4 ) 31.5 6 400 ( 4 ) Table 7 Isolating trucks for PowerCube type PB units Rated current of the isolating trucks (A - 40 C) kv Isc Icw W=600 W=750 W=750 W=1000 W=750 W=1000 Isolating truck PowerCube (ka) (ka) p=150 p=210 p=210 p=275 p=210 p=275 u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 u/l=310 H=260 H=280 H=280 H=280 H=325 H=345 ø=35 ø=35 ø=79 ø=109 ø=35 ø=79 12 16 16...1250 S-HD4/W 17.12.32 p150 PB 1/E 17.5 20 20 PB 1/M 31.5 31.5 16 16...1250 S-HD4/W 17.12.32 p210 PB 2/E 20 20 PB 2/M 31.5 31.5 40 40 S-HD4/W 17.12.50 p210 50 50 16 16...2000 S-HD4/W 17.20.32 p210 20 20 31.5 31.5 40 40 S-HD4/P 17.20.50 p210 50 50 16 16...2500 S-HD4/P 17.25.50 p275 PB 3/E 20 20 PB 3/M 31.5 31.5 40 40 50 50 16 16...3150 S-HD4/P 17.32.50 p275 20 20 31.5 31.5 40 40 50 50 31.5 31.5...3600 ( 1 ) S-HD4/P 17.32.50 p275 40 40...3600 ( 1 ) 50 50 31.5 31.5...4000 ( 1 ) S-HD4/P 17.32.50 p275 40 40...4000 ( 1 ) 50 50 24 16 16...1250 S-HD4/W 24.12.25 p210 PB 4/E 20 20 PB 4/M 16 16...2000 S-HD4/P 24.20.25 p275 PB 5/E 20 20 PB 5/M 16 16...2500 ( 2 ) S-HD4/P 24.25.25 p275 20 20 W = Width of PowerCube unit. P = Horizontal centre distance between circuit-breaker poles. U/L = Distance between top and bottom terminal. H = Distance between bottom terminal and earth. Ø = Diameter of the contacts in the PowerCube unit monobloc. (1) 3600 A with fan pre-installed in the PB3 modules. For 4000 A it is necessary to install another fan in the back of the switchgear (by the customer). (2) 2500 A with fan pre-installed in the PB5 modules. (3) Guaranteed using suitable fuses. (4) The rated current is subject to derating according to the rated current of the fuses. 17

3 TYPES AVAILABLE AND APPARATUS Table 8 Earthing trucks with making capacity for PowerCube type PB units Rated current of the earthing trucks (A - 40 C) kv Isc Icw W=600 W=750 W=750 W=1000 W=750 W=1000 Earthing PowerCube (ka) (ka) p=150 p=210 p=210 p=275 p=210 p=275 truck ( 1 ) u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 u/l=310 H=260 H=280 H=280 H=280 H=325 H=345 ø=35 ø=35 ø=79 ø=109 ø=35 ø=79 12 16 16...1250 PB 1/E 17.5 20 20 EM-U/W 17.12.32 p150 PB 1/M EM-L/W 17.12.32 p150 31.5 31.5 16 16...1250 PB 2/E 20 20 EM-L/W 17.12.32 p210 PB 2/M EM-U/W 17.12.32 p210 31.5 31.5 40 40 EM-L/W 17.12.50 p210 ( 2 ) 50 50 EM-U/W 17.12.50 p210 ( 2 ) 16 16...2000 20 20 EM-L/W 17.20.32 p210 EM-U/W 17.20.32 p210 31.5 31.5 40 40 EM-L/P 17.20.50 p210 50 50 EM-U/P 17.20.50 p210 16 16...2500 PB 3/E 20 20 PB 3/M EM-L/P 17.25.50 p275 31.5 31.5 EM-U/P 17.25.50 p275 40 40 50 50 16 16...3150 20 20 EM-L/P 17.32.50 p275 31.5 31.5 EM-U/P 17.32.50 p275 40 40 50 50 24 16 16...1250 PB 4/E EM-L/W 24.12.25 p210 20 20 PB 4/M EM-U/W 24.12.25 p210 16 16...2000 PB 5/E EM-L/P 24.20.25 p275 20 20 PB 5/M 16 16...2500 (2) 20 20 EM-U/P 24.20.25 p275 EM-L/P 24.25.25 p275 EM-U/P 24.25.25 p275 W = Width of PowerCube unit. P = Horizontal centre distance between circuit-breaker poles. U/L = Distance between top and bottom terminal. H = Distance between bottom terminal and earth. Ø = Diameter of the contacts in the PowerCube type PB unit monobloc. (1) - EM-L... = Earthing truck with making capacity with bottom bushings (for cable earthing). - EM-U... = Earthing truck with making capacity with top bushings (for earthing the busbar system). (2) Ask ABB. 18

Table 9 - Earthing trucks without making capacity for PowerCube type PB units Rated current of the earthing trucks (A - 40 C) kv Isc Icw W=600 W=750 W=750 W=1000 W=750 W=1000 Earthing PowerCube (ka) (ka) p=150 p=210 p=210 p=275 p=210 p=275 truck ( 1 ) u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 u/l=310 H=260 H=280 H=280 H=280 H=325 H=345 ø=35 ø=35 ø=79 ø=109 ø=35 ø=79 12 16 16...1250 PB 1/E 17.5 20 20 E-U/W 17.12.32 p150 PB 1/M E-L/W 17.12.32 p150 31.5 31.5 16 16...1250 PB 2/E 20 20 E-L/W 17.12.32 p210 PB 2/M E-U/W 17.12.32 p210 31.5 31.5 40 40 E-L/W 17.12.50 p210 ( 2 ) 50 50 E-U/W 17.12.50 p210 ( 2 ) 16 16...2000 20 20 E-L/W 17.20.32 p210 E-U/W 17.20.32 p210 31.5 31.5 40 40 E-L/P 17.20.50 p210 50 50 E-U/P 17.20.50 p210 16 16...2500 PB 3/E 20 20 PB 3/M E-L/P 17.25.50 p275 31.5 31.5 E-U/P 17.25.50 p275 40 40 50 50 16 16...3150 20 20 E-L/P 17.32.50 p275 31.5 31.5 E-U/P 17.32.50 p275 40 40 50 50 24 16 16...1250 PB 4/E E-L/W 24.12.25 p210 20 20 PB 4/M E-U/W 24.12.25 p210 16 16...2000 PB 5/E E-L/P 24.20.25 p275 20 20 PB 5/M E-U/P 24.20.25 p275 16 16...2500 E-L/P 24.25.25 p275 20 20 E-U/P 24.25.25 p275 W = Width of PowerCube unit. P = Horizontal centre distance between circuit-breaker poles. U/L = Distance between top and bottom terminal. H = Distance between bottom terminal and earth. Ø = Diameter of the contacts in the PowerCube unit monobloc. (1) - EM-L... = Earthing truck without making capacity with bottom bushings (for cable earthing). - EM-U... = Earthing truck without making capacity with top bushings (for earthing the busbar system). (2) Ask ABB. 19

3 TYPES AVAILABLE AND APPARATUS Table 10 Cable testing trucks for PowerCube type PB units W = Width of PowerCube unit. P = Horizontal centre distance between circuitbreaker poles. U/L = Distance between top and bottom terminal. H = Distance between bottom terminal and earth Ø = Diameter of the contacts in the PowerCube unit monobloc. (1) Ask ABB. Rated current of the cable testing trucks (A - 40 C) kv Isc Icw W=600 W=750 W=750 W=1000 W=750 W=1000 Cable PowerCube (ka) (kax3s) p=150 p=210 p=210 p=275 p=210 p=275 testing truck u/l=205 u/l=310 u/l=310 u/l=310 u/l=310 u/l=310 H=260 H=280 H=280 H=280 H=325 H=345 ø=35 ø=35 ø=79 ø=109 ø=35 ø=79 12 16 16...1250 PB 1/E 17.5 20 20 T/W 17.12 p150 PB 1/M 31.5 31.5 16 16...1250 PB 2/E 20 20 PB 2/M T/W 17.12 p210 31.5 31.5 40 40 50 50 T/W 17.12 p210 ( 1 ) 16 16...2000 20 20 T/W 17.20 p210 31.5 31.5 40 40 50 50 T/P 17.20 p210 16 16 2500 PB 3/E 20 20 PB 3/M 31.5 31.5 40 40 50 50 16 16 3150 T/P 17.32 p275 20 20 31.5 31.5 40 40 50 50 24 16 16...1250 PB 4/E 20 20 T/W 24.12 p210 PB 4/M 16 16...2000 PB 5/E 20 20 T/W 24.20 p275 PB 5/M 16 16...2500 ( 1 ) 20 20 T/P 24.25 p275 Table 11 - PowerCube type PB units without apparatus Enclosure characteristics Configuration Rated Width Rated Isc (ka) Icw Bus riser or direct Bus riser or direct Measuring ( 2 ) Measuring ( 2 ) voltage current (ka x 3s/1s) incoming feeder incoming feeder with (kv) (mm) (A) ( 1 ) ( 1 ) earthing switch 12-17.5 600 1250 31.5 31.5 PB1/RE - PB1/RM PB1/RE - PB1/RM PB1/RE - PB1/RM PB1/RE - PB1/RM 12-17.5 750 2000 31.5 31.5 PB2/RE - PB2/RM PB2/RE - PB2/RM PB2/RE - PB2/RM PB2/RE - PB2/RM 12-17.5 750 2000 40-50 40-50 PB2/RE - PB2/RM PB2/RE - PB2/RM PB2/RE - PB2/RM PB2/RE - PB2/RM 12-17.5 1000 4000 31.5 31.5 PB3/RE - PB3/RM PB3/RE - PB3/RM PB3/RE - PB3/RM PB3/RE - PB3/RM 12-17.5 1000 4000 40-50 40-50 PB3/RE - PB3/RM PB3/RE - PB3/RM PB3/RE - PB3/RM PB3/RE - PB3/RM 24 750 1250 PB4/RE - PB4/RM PB4/RE - PB4/RM PB4/RE - PB4/RM PB4/RE - PB4/RM 24 1000 2500 PB5/RE - PB5/RM PB5/RE - PB5/RM PB5/RE - PB5/RM PB5/RE - PB5/RM (1) On earthing switch, if provided. (2) For units PB/RE end for PB1/RM, the VT compartment is not available. Construction at customer care. 20

Accessories The table shows the accessories available and the relative possible combinations of the PowerCube type PB units. PB type PowerCube unit PB1 PB2 PB3 PB4 PB5 PB1/R PB2/R PB3/R PB4/R PB5/R Width (mm) 600 750 1000 750 1000 600 750 1000 750 1000 Rated 12 kv - - - - voltage 17.5 kv - - - - 24 kv - - - - - - Unit Incoming/outgoing/bus-tie - - - - - Bus-riser/measurements/direct incoming - - - - - Standard 1a Group of auxiliary contacts fittings connected/isolated - - - - - 1b Anti-racking-in lock for circuit-breakers with lower rated current than that of the compartment or for apparatus not foreseen for the compartment itself - - - - - 2 Circuit-breaker anti-racking-in lock - - - - - Accessories to be specified at the time of ordering (assembly by ABB) Accessories on request (assembly by the customer) 3 VT compartment (only PB/M units) - - 4 Earthing switch 5 Key locks open or closed or open and closed for earthing switch 6 Electro-mech. lock for earthing switch - 24-30-48-60-110-125-220-250 V c.c. - 110-220 V c.a. 7 Earthing switch auxiliary contacts (5 or 10) 8 Safety device for the metal shutters (Fail Safe) - - - - - 9 Voltage signalling device ( 2 ) 10 Anti-condensation heater (110-220 Vca 50 Hz) - - - - - 11 Contact for earthing truck racked-in position - - - - - 12 Electromechanical interlock for circuit-breaker compartment door - 24-30-48-60-110-125-220-250 V c.c. - 110-220 V c.a. - - - - - 13 Padlock for metal shutters (top or bottom or top and bottom) - - - - - 14 Key lock for racking in earthing truck - - - - - 15 Earthing switch operating lever - extra in relation to normal supply ( 1 ) 16 Lifting eyebolts ( 2 ) 17 Apparatus transport and racking/in truck - - - - - (1) Remember that the standard supply provides up to 10 levers per order position with a maximum of 1 lever per enclosure (prepared for earthing switch). (2) Only for PowerCube type PB/M modules. Capacitive dividers at customer care. 21

4 OVERALL DIMENSIONS AND WEIGHTS PB/E type units Rated Rated Isc Table of Weight Module voltage current Icw dimensions A [mm] B [mm] C [mm] [kg] [kv] [A] [kv] ( 1 ) PB1/E PB2/E PB3/E 12 630-1250 31.5 1VCD003369 600 1016 1120 17.5 630-1250 31.5 1VCD003369 600 1016 1120 12 630...2000 31.5 1VCD003370 750 1016 1120 12 1250...2000 40-50 1VCD003370 750 1016 1120 17.5 630...2000 31.5 1VCD003370 750 1016 1120 17.5 1250...2000 40-50 1VCD003370 750 1016 1120 180 200...240 12-17.5 2500 31.5 1VCD003371 1000 1030 1120 300 12-17.5 3150 31.5 1VCD003372 1000 1030 1120 320 12-17.5 3600...4000 31.5 1VCD003373 1000 1030 1120 350...380 12-17.5 2500 40-50 1VCD003371 1000 1030 1120 300 12-17.5 3150 40-50 1VCD003372 1000 1030 1120 320 12-17.5 3600-4000 40-50 1VCD003373 1000 1030 1120 350...380 PB4/E 24 630-1250 31.5 1VCD003374 750 1246 ( 2 ) 1230 250 PB5/E 24 1600-2000 31.5 1VCD003376 1000 1246 ( 2 ) 1230 310 24 2500 31.5 1VCD003376 1000 1246 ( 2 ) 1230 340 PB1/RE 17.5 31.5 1VCD003377 600 1016 ( 2 ) 1120 165 17.5 31.5 1VCD003378 750 1016 ( 2 ) 1120 165...215 PB2/RE 17.5 40-50 1VCD003378 750 1016 ( 2 ) 1120 165...215 NOT 12-17.5 31.5 1VCD003379 1000 1030 ( 2 ) 1120 270 APPLICABLE PB3/RE 12-17.5 40-50 1VCD003379 1000 1030 ( 2 ) 1120 270 PB4/RE 24 31.5 1VCD003380 750 1310 ( 2 ) 1230 215 PB5/RE 24 31.5 1VCD003381 1000 1246 ( 2 ) 1230 250 ( 1 ) Weight without earthing switch. ( 2 ) Dimension with earthing switch. 22

PB/M type units PB/R type units Rated Rated Isc Table of Weight Module voltage current Icw dimensions A [mm] B [mm] C [mm] [kg] [kv] [A] [kv] ( 1 ) PB1/M PB2/M PB3/M 12 630-1250 31.5 1VCD000023 600 1016 1680 17.5 630-1250 31.5 1VCD000028 600 1016 1680 12 630...2000 31.5 1VCD000024 750 1016 1680 12 1250...2000 40-50 1VCD000027 750 1016 1680 17.5 630...2000 31.5 1VCD000029 750 1016 1680 17.5 1250...2000 40-50 1VCD000030 750 1016 1680 200 220...260 12-17.5 2500 31.5 1VCD000025 1000 1030 1680 320 12-17.5 3150 31.5 1VCD000026 1000 1030 1680 340 12-17.5 3600...4000 31.5 1VCD000043 1000 1030 1680 370...400 12-17.5 2500 40-50 1VCD000037 1000 1030 1680 320 12-17.5 3150 40-50 1VCD000038 1000 1030 1680 340 12-17.5 3600-4000 40-50 1VCD000039 1000 1030 1680 370...400 PB4/M 24 630-1250 31.5 1VCD000031 750 1510 1745 270 PB5/M 24 1600-2000 31.5 1VCD000032 1000 1246 1745 330 24 2500 31.5 1VCD000044 1000 1246 1745 360 Rated Rated Isc Table of Weight Module voltage current Icw dimensions A [mm] B [mm] C [mm] [kg] [kv] [A] [kv] ( 2 ) ( 1 ) PB1/RM 17.5 31.5 1VCD000033 600 1016 1745 185 12 31.5 1VCD000034 750 1016 1745 185...235 PB2/RM 17.5 40-50 1VCD000040 750 1016 1745 185...235 NOT 12-17.5 31.5 1VCD000041 1000 1030 1680 290 APPLICABLE PB3/RM 12-17.5 40-50 1VCD000042 1000 1030 1680 290 PB4/RM 24 31.5 1VCD000035 750 1310 1745 270 PB5/RM 24 31.5 1VCD000036 1000 1246 1745 270 ( 1 ) Weight without earthing switch and without VT compartment. ( 2 ) Dimension with earthing switch. (*) 23

5 ELECTRIC CIRCUIT DIAGRAM Diagrams of the applications 24

25

5 ELECTRIC CIRCUIT DIAGRAM Diagrams of the applications 26

Reference designations Reference designations (in compliance with IEC 61346-2 Standard and with the ABB 2NBA000001 technical standard). Designation Description Number of the diagram figure -BC Current transformer -BE Earthing switch auxiliary contacts (see note B) -BT4 Contacts on the switchgear for signalling truck in connected position (see note C) -BT5 Contacts on the switchgear for signalling truck in isolated position (see note C) -BW1 Position contact of the front fan -BW2 Position contact of the rear fan -CC1 Condenser for the front fan -CC2 Condenser for the rear fan -KA3 Current measuring relay -KA4 Auxiliary contactor for operation of the front fan -KA5 Auxiliary contactor for operation of the rear fan -KT1, -KT2 Timed auxiliary relays for control of front forced ventilation -KT3, -KT4 Timed auxiliary relays for control of rear forced ventilation -KT5 Timed auxiliary relay for signalling alarm of front forced ventilation not working -KT6 Timed auxiliary relay for signalling alarm of rear forced ventilation not working -MV1 Front fan (see note E) -MV2 Rear fan (see note E) -PA Ammeter -PR1 Red lamp for signalling alarm of front forced ventilation not working -PR2 Red lamp for signalling alarm of rear forced ventilation not working -PT1 White lamp for signalling alarm of front forced ventilation working -PT2 White lamp for signalling alarm of rear forced ventilation working -RL3 Electro-mechanical lock on earthing switch closing operation -RL4 Locking magnet. When de-energised it mechanically prevents door opening -SL Contact for the earthing switch operation lock -SU3 Delayed pushbutton for enabling earthing switch operation (maximum delay allowed is 1 minute) -SU3 Pushbutton for releasing the door -XF1 Connector for isolation of the front forced ventilation circuits -XF2 Connector for the rear forced ventilation circuits -XF3 Connector for the front forced ventilation circuits 27

5 ELECTRIC CIRCUIT DIAGRAM Figure Description Fig. 1 Contacts for electrical signalling of circuit-breaker in connected position (see note C) Fig. 3 Contacts for electrical signalling of circuit-breaker in isolated position (see note C) Fig. 20 Circuit of the electro-mechanical lock on the earthing switch closing operation: operation is only allowed with coil -RL3 energised Fig. 21 First pack of earthing switch auxiliary contacts (see note B) Fig. 22 Second pack of earthing switch auxiliary contacts (see note B) Fig. 23 Circuit of the electro-mechanical lock on door opening: opening is only allowed with coil -RL4 energised Fig. 41 Front forced ventilation circuit Fig. 43 Front and rear forced ventilation circuit Notes A) The switchgear is only fitted with the applications specified in the order confirmation. B) The -BE auxiliary contacts are supplied in the position indicated on the diagram. However, they can easily be converted by the user from break contacts into make contacts or vice versa. C) The -BT4 and BT5 position contacts are changeovers. Therefore the break and make contact belonging to the same position contact cannot be supplied with different voltages. D) When fig. 23 is required, the -BT5 contact (terminals 51-52-53-54) in fig. 3 is not available. E) Connection of the fans must take place when at least one phase exceeds the following thresholds for a time of 60 seconds: - UniSafe 12-17.5 kv 3600 A = 3000 A (front fan) - UniSafe 12-17.5 kv 4000 A = 3000 A (front fan) e 3600 A (rear fan) - UniSafe 24 kv 2500 A = 2250 A (front fan). Disconnection of the fans must take place when all three phases have currents lower than the following values for a time of 300 seconds: - UniSafe 12-17.5 kv 3600 A = 2900 A (front fan) - UniSafe 12-17.5 kv 4000 A = 2900 A (front fan) and 3500 A (rear fan) - UniSafe 24 kv 2500 A = 2150 A (front fan). 28

Graphic symbols (in compliance with IEC 60617 and CEI EN 60617 Standards) Mechanical, pneumatic or hydraulic connection Capacitor (general symbol) Position changeover break before make contact (limit switch) Delayed movement (in the direction the arc moves towards its centre) Semi-conductor diode (general symbol) Control coil (general symbol) Pushbutton actuator Single-phase asynchronous motor, rotor under short-circuit, terminals for aux. phase taken outside Control coil with two separate windings Earth (general symbol) Current transformer Control coil of a relay with delay on relapse ritardo alla ricaduta Conductive electric part, frame Make contact Control coil of a relay with delay on attraction Connection of conductors Break contact Ammeter Terminal Closing position contact (limit switch) Lamp (general symbol) Socket and plug (female and male) Opening position contact (limit switch) 29

6 COMPLETION OF THE SWITCHGEAR For completion of the switchgear, ABB can also offer the components indicated below. For further details, please consult us. PR512 switchgear protection device With regard to the functionality of protections 50/ 51/50N/51N, the PR512 are self-supplied type releases. To guarantee operation of the ammeter and of the dialogue function, an auxiliary power supply must also be provided. They are available in the following versions: PR512/P. Protection against overload (51) and instantaneous or delayed short-circuit (50). PR512/P. Protection against overload (51), instantaneous or delayed short-circuit (50), earth fault (51N) and instantaneous or delayed earth fault (50N). PR512/PD. Protection against overload (51), instantaneous or delayed short-circuit (50), earth fault (51N) and instantaneous or delayed earth fault (50N). Dialogue function to be connected to the electrical installation management system. For the characteristics of the current transformers to be combined with the PR512, please refer to technical catalogue 1VCP000055. Voltage transformers The voltage transformers are of the type insulated in resin and are used to supply measuring and protection devices. The are available for fixed assembly or for installation on withdrawable trucks. They comply with the IEC 60044-2 Standards. Their dimensions are usually according to the DIN 42600 Standard. The transformers installed on withdrawable trucks are, on the other hand, of the dedicated type. These transformers can have one or two poles, with performances and precision classes suitable for the functional requirements of the instruments connected to them. When they are installed on withdrawable trucks, they are fitted with medium voltage protection fuses. Replacement of the fuses can be carried out with the switchgear in service. Current transformers The current transformers are of the type insulated in resin and are used to supply measuring and protection devices. These transformers can either have a wound core or a through bar with one or more cores, with performance and precision classes suited to the installation requirements. They comply with IEC 60044-1 Standards. Their dimensions are usually according to the DIN 42600 Standard. The current transformers can also be fitted with a capacitive socket for connection to the voltage signalling lamps. Measurement sensors (for application with REF542plus electronic or similar protection units) The introduction of digital technologies into electrical measuring and protection instruments has considerably modified the performances required of transformers. The analog input levels of the instruments have been notably reduced when compared with those of traditional systems. For this reason, ABB has introduced a new range of sensors which best covers the characteristics of the new generations of instruments. The switchgear can be equipped with ABB KEVCD Block Type sensors up to 24 kv. The current sensors comply with the IEC 60044-8 (CDV) Standards, whereas the voltage sensors comply with the IEC 60044-7 Standards. The dimensions are in accordance with the DIN 42600 Narrow Type standard. Both the current and voltage sensors or just the current sensors can be integrated simultaneously in the same resin body. The voltage divider for connection to the voltage signalling lamps is also inserted. The measurement sensors and the multi-purpose ABB units have Cl. 1 class of precision. Current sensor The current sensor consists of a Rogowski coil without the ferromagnetic core, so it is not affected by saturation phenomena. When a coil is formed by a uniform winding over a closed non-magnetic core of constant crosssection, the induced voltage in the secondary circuit is directly proportional to the variation in the let-through current. To obtain a signal proportional to the current given, this voltage must be integrated. The multi-purpose devices carry out this function and use the signal obtained both for the measurements and for the protections. 30

ABB KEVCD type combined voltage-current sensors. REF542plus electronic unit (Product guide 1MRS 755859) The REF542plus unit integrates all the secondary functions relative to a switchgear unit in a single module fitted with watchdog. Thanks to the flexibility of its software, the unit is able to satisfy a vast range of installation requirements: protection measurement, control and signalling. The user interface is simple and easy to use. Main characteristics of the current sensors Linear response over the whole measurement range; no saturation phenomenon; no hysterisis phenomenon; a single instrument for protections and measurements; high class of precision; high degree of immunity to electromagnetic interferences; the output signal is a voltage (150 mv) proportional to the variation in the current time. Measurement of the current is obtained by integrating the signal; just two coils cover the range of rated currents from 0 to 3200 A; the winding can remain open even with the switchgear in service. Voltage sensor The voltage sensor consists of a resistive divider through which the signal is taken up. This sensor, too, is the of the unsaturable and linear type over the whole measurement range. The output signal is a voltage directly proportional to the primary voltage. The resistive element consists of a bar made of ceramic material. The voltages sensors are used for taking measurements and for supplying the protections with power simultaneously. Main characteristics of the voltage sensors Linear response over the whole measurement range; no saturation phenomenon; no ferroresonance phenomenon; a single instrument for protections and measurements; high class of precision; high degree of immunity to electromagnetic interferences; the output signal is a voltage directly proportional to the primary voltage; the division ratio is 10000/1; a single divider covers the range from 0 to 24 kv rated voltage. REF542plus in a kit for OEM The integrated protection and control unit is based on the REF542plus platform - multi-purpose unit for medium voltage switchgear. The REF542plus unit uses the latest microelectronic and information technology discoveries. The main functions carried out by the REF542plus unit are as follows: protection control measurement monitoring quality of the energy communication. Thanks to the exceptional flexibility and scalability of this advanced unit, all the functions are integrated in a single configurable environment. This unit therefore makes targeted and intelligent solutions possible, with limited cabling requirements, in those places where the traditional approach would be costly and inefficient. Industrial IT REF542plus has been tested and certified as conforming with Industrial IT, Level 0 - Information. All the information about the product is provided in an interactive electronic format, compatible with ABB Aspect Object TM technology. ABB s commitment to respecting the Industrial IT conformity guarantees that each construction unit is provided with all the instruments needed to ensure efficient installation, function and maintenance operations throughout the useful life of the product. For further information about Industrial IT please go to the site www.abb.com/industrialit. 31

6 COMPLETION OF THE SWITCHGEAR Preconfigured solutions based on REF542plus Some solutions already configured for protection and control of most of the common medium voltage applications are defined here. These solutions are based on the REF542plus unit and do not require any programming. The REF542plus unit is supplied already programmed and ready for installation. Only the protection parameter setting remains to be carried out. The REF542plus unit, already configured, can only be ordered as part of the medium voltage kit. It cannot be sold separately. Single-line diagram of the primary part. Fixed or withdrawable circuit-breaker. Manual earthing switch. Configuration of the primary part is structured as shown in the single-line diagram at the side. The circuit-breaker can be fixed or withdrawable. The earthing switch is manual. Configurations with a contactor in place of the circuit-breaker are also provided for motor outgoing feeders. The ATEX certified version, in accordance with directive 94/9/EC for explosive environments, is also available. Please contact ABB. Note Specific and customised solutions and protection diagrams are possible. Please contact ABB. Fuses Fuses to be combined with apparatus such as the contactor, are available for protection of feeders, motors, capacitors, instrument voltage transformers, etc. The fuses comply with DIN or BS Standards. For the contactor-fuse combination and coordination, please refer to the 1VCP000049 technical catalogue. 32