InteliCharger V 20A Intelligent Automatic Battery Charger

Similar documents
DEEP SEA ELECTRONICS PLC

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

USER S MANUAL SOLAR POWER INVERTER KW-6KW

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Pure Sine Wave Inverter Charger

INTRODUCTION MARKET SECTORS CUSTOMER SERVICE CCL OFFERS YOU. Switchmode Technology A highly efficient, lightweight

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

GCU-10. Automatic Engine Control Unit Operators Manual

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

OD10 10A Outdoor Solar Charge Controller

SECTION DC POWER SUPPLY/BATTERY CHARGER

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

CX-SERIES ADVANCED BATTERY CHARGER

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

DEEP SEA ELECTRONICS PLC

12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER

Innovative Circuit Technology Ltd.

BS20 BATTERY CHARGER For lead-acid batteries

BATTERY CHARGER CHR-1445

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking.

REVISED ATM72 Auto Transfer Module

DEEP SEA ELECTRONICS PLC

Solar off-grid Inverter. SP Junior Series. User Manual

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

INSTRUCTION MANUAL CAUTION

Switch Mode, Automatic, Lead Acid Battery Charger Model: SEC A SEC A SEC A

Alphapower HTU UPS. Some key features include:

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

INVERTER FOR DC CRANE CABIN AIR CONDITIONING UNIT 3KW VERSION


BVF300 'Special' Battery Voltage Monitor

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

MPPT5012A-DUO-BT MPPT5025A-DUO-BT

- 1 - Tel.: Fax: Battery charging units BLG2024 and BLG3524

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

TECHNICAL DATA SHEET LAD/CYCLER16KW

AUTOMATIC BATTERY CHARGER MODELS SEC A SEC A OWNER S MANUAL

DBC-1 DEIF Battery Charger

LBC Series Battery Charger Instructions

OWNER S MANUAL Please read this manual before operating your power supply

LEAD ACID BATTERY CHARGER

User Manual WT Combi-S Pure Sinus Wave Inverter

More current on board

BAC06 SERIES (BAC06A/BAC06V) SWITCH-TYPE BATTERY CHARGER USER MANUAL

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

User s Manual. Automatic Switch-Mode Battery Charger

AUTOMATIC BATTERY CHARGER

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

AL600ULX Series. Power Supply/Charger Installation Guide

Intelligent Charging System Series

SNTL150P1205CD SNTL150P2405CD SNTL150P1205CDA SNTL150P2405CDA

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

PO Box 2484 Rowville Vic 3178

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

All In one uninterruptible power supply solutions

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

SCCP PWM Charge Controller/Load Manager Owner s Manual

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

BatteryMINDer 1500* & BatteryMINDer Plus 1510*

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

12 Volt 1500 ma Convertible Charger - Maintainer - Desulfator*

Phoenix Inverter

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES


HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Pure sine wave charger inverter Product Manual

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

AC CONVERTER / BATTERY CHARGER

BATTERY BOOSTERS / CHARGERS BC120N BC130N BC210N BC320E BC410E BC520N

Eclipse Solar Suitcase

Innovative Circuit Technology Ltd.

DIN Rail UPS Model: DIN-UPS 48-5 Installation/Operation Manual

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

DIESEL Engine Fire Pump Controllers Features

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

SDM72 Start on Demand Modules

Installation and Operating Instructions. Solar System Controller ISC3020

Specification of Battery Charger

GENIUS-II Series Owner's Manual

SAFETY WARNINGS AND GUIDELINES

Installation and Operating Instructions. Solar System Controller ISC3030

DKG-114 MANUAL AND REMOTE START UNIT

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Battery Chargers - Phase Three Series

Security alarms, warning systems.

600W Intelligent Single Output Battery Charger 21A 10.5A VOLTAGE RANGE FREQUENCY RANGE

TRIPS AND FAULT FINDING

Low Frequency Inverter. User Manual

AC/DC Converter MBP250-2A13D13M

Transcription:

InteliCharger InteliCharger 500 24V 20A Intelligent Automatic Battery Charger September 2012 Reference Guide TABLE OF CONTENTS 1 Document information... 2 2 EQUIPMENT RATING... 3 3 ENVIRONMENT... 3 4 PROTECTION... 3 5 INSTRUMENTATION... 4 6 CHARGING PROFILE... 4 7 COOLING... 4 8 TERMINATION... 4 9 CONNECTION... 5 10 APPENDIX A - Automatic Calibration Routine... 5 11 APPENDIX B - Manual Calibration Routine... 6 12 APPENDIX C - DEFAULT FACTORY... 6 Copyright 2011 ComAp s.r.o. ComAp, spol. s r.o. Kundratka 17, 180 00 Praha 8, Czech Republic Tel: +420 246 012 111, Fax: +420 266 316 647 E-mail: info@comap.cz, www.comap.cz

1 Document information INTELICHARGER 500 - REFERENCE GUIDE WRITTEN BY: ALES PETRIK 2012 COMAP LTD. KUNDRATKA 17, PRAHA 8, CZECH REPUBLIC PHONE: +420246012111, FAX: +420266316647 WEB: HTTP://WWW.COMAP.CZ, E-MAIL: INFO@COMAP.CZ DOCUMENT HISTORY REVISION NUMBER RELATED SW. VERSION DATE r1-1.9.2012 InteliCharger 500, ComAp June 2012 2

2 EQUIPMENT RATING Input Voltage Inrush Current Maximum Input Current Output Voltage Output Current Recommended Battery Types Switchable 90-132 Vac or 180-264Vac 1 Ph. 47-63 Hz. 45A worst case. 8A @ 115Vac 3.2A @ 230Vac. 24Vdc Nominal Works preset to 27.5V float / 28.8V boost. Output voltage can be adjusted but a re-calibration MUST be performed (see section 9 of this specification). 20A works preset. Flooded Lead Acid. Sealed AGM (Sealed Lead Acid). Gel. Ni-Cad. Please contact us for other battery types. Fault Contact 1A 30V DC 3 ENVIRONMENT Working Temp. Range -20 to +50 C. Storage Temp. Range -40 to +85 C. Working Humidity 20-90% non-condensing RH. 4 PROTECTION AC Input DC Output Short Circuit / Overload Over Voltage Reverse Battery Internal fast blow fuse. Upstream input fuse should be fitted. ATO blade type fuse 25A 32Vdc. Constant current limiting with automatic recovery. Over Temperature Unit will shut-down if internal temperatures are exceeded. Automatically switches back on once the unit has cooled. Output voltage shut-down. Recycle AC input power to reset. Internal diode (will blow DC output fuse). InteliCharger 500, ComAp June 2012 3

5 INSTRUMENTATION Charger Fail Fault Alarm Alarm LED indicator on front panel, Green = healthy / Red = failed. LED indicator on front panel, Green = healthy / Red = failed. Volt free form C contact set, de-energising on fault. The charger failed alarm must be active for 60 seconds to de-energise the fault signal. 6 CHARGING PROFILE 3 stage bulk / absorb / float modes. The charger will automatically switch to bulk (auto-boost) mode on a low battery condition. Once the bulk voltage level is reached the charger will switch to absorb (boost run-on) mode. The absorb time period is variable and dependent on the length of the bulk charging period. On expiration the charger switches back to float mode. 7 COOLING Convection cooled, bottom to top air-flow is required. 8 TERMINATION AC Input DC Output (Battery) Manual Boost Remote Fault Signal (Volt free form C) Maximum cable size = 4.0 Sq.mm. LIN Line NIN Neutral EIN Earth Maximum cable size = 4.0 Sq.mm. B+OUT Battery +Ve B-OUT Battery Ve Maximum cable size = 2.5 Sq.mm. 21 Link to enable 22 Maximum cable size = 2.5 Sq.mm. 18 Normally Closed 19 Common 20 Normally Open InteliCharger 500, ComAp June 2012 4

9 CONNECTION Please refer to drawing on page 8 Do not expose the unit to rain or any form of moisture. Avoid operation in direct sunlight and dust contaminated environments. Ensure the units AC input supply is isolated. Remove the terminal cover ensuring the cables are fed through the corresponding apertures when making connections. Ensure the AC input selector switch is in the correct position and connect the 110V or 230V AC input supply. Make necessary remote fault alarm and/or manual boost connections. Connect the battery to the B-OUT (battery negative) and B+OUT (battery positive) terminals. Always ensure the battery is of the correct type and number of cells.note the alarm circuits power-up when the battery is connected. Switch on the AC input. After a short delay charge current will flow to the battery. As the batteries charge the output current will reduce; High output current = discharged battery, low output current = charged battery. When the battery has fully charged its voltage can be checked with a DVM across the battery terminals. If the float voltage is adjusted from factory default then the alarm system MUST be re-calibrated, following the instructions below. 10 APPENDIX A - Automatic Calibration Routine The battery MUST be disconnected from the charger before proceeding. Connect a DVM to the B+ / B- Out terminals of the charger. Set the float voltage to the desired level by turning the 'Vfloat' multi-turn potentiometer. Press and hold the PROG push-button, all LED s turn Red. Continue to hold for 10 seconds until all LED s turn Green then release the push-button. Set the boost voltage to desired level by turning the 'Vboost' multi-turn potentiometer. Operate and release the push-button again, the controller switches to float mode and all LED s are Red. Automatic calibration now commences. After approximately 30 seconds the auto-calibration is complete and all LED's should be green to indicate normal mode. InteliCharger 500, ComAp June 2012 5

APPENDIX B - Manual Calibration Routine When the automatic calibration levels are not suitable a manual calibration can be performed. The battery MUST be disconnected from the charger before proceeding. Power down the unit, hold the PROG push-button down and power up the charger. Release the 'PROG' push-button and the LED's will flash Red/Green in quick succession to indicate manual calibration mode. The following sequence must be followed by adjusting the float voltage potentiometer to the desired voltage level at each stage: Charger Fault Setting Procedure Fail LED LED Red Red Set Boost on Voltage, operate PROG push button. Green Green Set Boost off Voltage (high level), operate PROG push button. Red Green Set Boost off Reset Voltage (low level), operate PROG push button. Red Red Set Charger Fail Low Voltage Alarm, operate PROG push button. Green Red Set Charger Fail Low Voltage Reset, operate PROG push button. Red Red Set Charger Fail High Voltage Alarm, operate PROG push button. Green Red Set Charger Fail High Voltage Reset, operate PROG push button. 11 APPENDIX C - DEFAULT FACTORY All units leave the factory calibrated to the following levels: AC Input 230 Vac DC Output Float Voltage 27.50 V DC Output Boost Voltage 28.80 V DC Output Current 20.00 A Charger Fail Low Volts Alarm 25.50 V Charger Fail Low Volts Reset 26.00 V Charger Fail High Volts Alarm 29.05 V Charger Fail High Volts Reset 28.50 V Boost On Voltage Level 25.75V Boost Off Voltage Level 28.6V Fault Alarm Timer 60 Seconds Absorb Timer (Boost run on) Variable 2-60 minutes. InteliCharger 500, ComAp June 2012 6

InteliCharger 500, ComAp June 2012 7